Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC | L1 | Accepted-AOC DUE TO BEING L1 AND REASONABLE | |
| 2 | L2₹36.7 L+₹1.9 L (5.62%)Rejected-Finance | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
8 Feb 2023, 6:00 pmClosed
GE (SOUTH) AKHNOOR
GE (SOUTH) AKHNOOR C/O 56APO
SPECIAL REPAIR TO CTS BOOSTER PUMP HOUSE AND PUMP HOUSE NO 2, SPECIAL REPAIR TO OPEN DRAINAGE (JCOs /OR MD ACCN) AND OTHER SANCTIONED WORKS UNDER GE (SOUTH) AKHNOOR.
2023_MES_573577_1
GES/AKH-37/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS D AND ABOVE WITH CATEGORY a(i) and b(i)
9 documents required · 9 mandatory
₹500
GE (SOUTH) AKHNOOR
₹82,000
20 Feb 2023
6 Jan 2023
11 Feb 2023
6 Jan 2023
8 Feb 2023
20 Jan 2023
Amount
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick, on other than fair faces of brick or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 5mm thick on any type of surfaces, on ceiling, in cement mortar 1:3, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Extra for forming fair finished drain or channel 30 Cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing compound shall deemed included in quoted rates.
M&L for applying two coats of cement base paint over a coat of primer on newly plastered surfaces of walls including preparation of new surfaces complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whitening, preparatory to distempering, after making surface smooth with 3mm thick birla white wall care putty, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white washing, complete all as specified and as directed by Engineer-In-Charge.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 50mm thick, as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight, complete all as specified and as directed by Engineer-In-Charge.
Machine cut kota stone slab, (minimum size shall be 550x550mm), flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6 incl dismantling of old stone slabs and tiles of any descrption, complete all as specified and as directed by Engineer-In-Charge.
Machine cut kota stone slab, (size shall in one length), 16-20mm thick, as in riser of steps, skirting, dado and pillar, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or back plastering layer of mortar 15mm thick in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-In-Charge.
Glazed ceramic tiles in vertical surface/ dado, size 300x450x7mm thick, 400x400x6/7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified and as directed by Engineer-In-Charge.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified and as directed by Engineer-In-Charge.
Pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed.
PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in back filling of steel chowkhat single or double rebated or for fixing complete all as specified and directed.
Factory made, glazed and skeleton shutters in second class hardwood, 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats, complete all as specified and as directed by Engineer-In-Charge.
Factory made, 35mm thick, second class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and as directed by Engineer-In-Charge.
Factory made steel window, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter with wire mesh and plain sheet glass 3.0mm thick, 4mm thick frosted glass, jointed internally and made with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1304, sheet No- 1/3 to 3/3 and as directed by Engineer-In-Charge. Note :- Cost of window shall include all members and spare parts as elaborated in the Drwaing and in the specifications and nothing shall be paid extra seperately.
Supply and fixing in repair of cup board shutter 20mm thick (style) factory made PVC incl chowkat frame made out of MS tubes of 19 guage for top and bottom rails M S frame shall be covered with heated molded designer colour PVC channel having PVC sheet strip of 10 MM width stuck inside with solvent cement for styles and plane colour PVC sheets of top rail, lock rail and bottom rail on either side 10 mm (5 mm x 2) thick of 20 mm and 20 mm cross PVC sheets and as gap inserted for top and bottom rail. Paneling for plain colour PVC sheets to be fitted in the MS frame welded /sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement in the frame at site as per drawing held with AGE B/R-I and to the entire specifications. , complete all as specified and as directed by Engineer-In-Charge.
Mild steel sliding door bolts, size 250mm long, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and as directed by Engineer-In-Charge.
Mild steel barrel tower bolts, size 150mm, stove enamelled black, with bright bolt and fixed, complete all as specified and as directed by Engineer-In-Charge.
Mild steel pressed handles, size 150mm, oval type, stove enamelled black, complete all as specified and as directed by Engineer-In-Charge.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, cverall length of cover plate 150mm, fixed in floor, complete all as specified and as directed.
Mild steel spring for doors, 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of old/ damaged existing roof treatment with concrete and cleaning all waste and dirt by wire mesh, picking, sweeping and washing down with water to remove dust, etc, and removal of all material out side the cant area and Applying one coat of neat cement slurry with 3.0 Kg of cement per Sqm on cleaned surfaces of roof, evenly, and screed bed/rendering 10mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement) including Water proofing treatment on roof top with APP (Ataxic Poly Propylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film, minimum weight not less than 3.0 Kg/ Sqm, 2.0mm thick, centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point, high heat resistance and cold resistivity to make it ideal for all water proofing treatment, with polymeric mix protection on both sides with 20 micron HMHDPE film, laid over one coat of bituminous primer conforming to IS: 3384, applied @0.40 Kg/ Sqm and one coat of hot blown bitumen of 85/25 grade, conforming to IS:702, applied @1.20Kg/ Sqm on prepared surfaces of roof, overlap should be not less than 150mm at ends and 75mm at sides, joints and overlaps uniformly bounded with LPG torch flame including applying of one coat of semi hot blown bitumen of 85/25 grade, @1.20 Kg Sqm and fine screened sand in dry condition @0.50 Kg/ Sqm after laying the membrane and applying two coats of aluminium paint, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing chemical shall be included in quote rate.
Dismantling of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles or of any description and of any location, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
All as per srl item No 34.00 above but except bricks.
Mild steel square bar framed work such as in grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; frame work of water tanks and similar work conforming to Fe-290, Gde-E-165, including cutting and welding, complete all as specified and as directed by Engineer-In-Charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, omplete all as specified and directed.
M&L Hard core of broken stone boulders of gauge n exc 63 mm, deposited spread and leveled in layers n exc 15 cm thick, watered and rammed to true surface complete all as specified and directed. Note :Thickness shall not exceed from 100mm thick.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid over and including 30mm thick well rammed sand cushion laid over and including sub base of 100mm thick of plain cement concrete (1:5:10), type E-2 (using 40mm graded crushed stone aggregate), with grey cement and no pigment, complete all as specified and as directed by Engineer-In-Charge.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid over and including 30mm thick well rammed sand cushion laid over and including sub base of 75mm thick of plain cement concrete (1:5:10), type E-2 (using 40mm graded crushed stone aggregate), with grey cement and no pigment, complete all as specified and as directed by Engineer-In-Charge.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
M&L Cement concrete M-15, type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating and necessary form work, all as specified.
S&F Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc, complete all as specified and directed.
Demolition of cement concrete of any description and in any postition not otherwise specifically provided for, including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-2, (using 40mm graded crushed stone aggregate), nominal mix in surface channels and drains, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Demolition of cement concrete (reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), including cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Precast reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs and similar articles with plain faces as specified in clause No- 4.11.16 of SSR Part-I (2009), set in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-In-Charge.
Supply, installation, commissioning and testing of Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 100 KVA, complete all as specified and directed. Make :- AE/ANDREW YULE/ELECTRICFIELD
S&F in replacement of Ceiling fan, mettalic, sweep 1200mm, with BLDC Motor, high speed, inclduing necessary fitting/fixtures such as Hook and clamps etc including connectig wire of suitable size and length from ceiling rose to fan connector, having BEE Star Rating- 5 Star, Rated Power Input in Watt 28±10%, Rated Speed in RPM 345±10%, Rated Air Delivery in CuM/ Min- 220 Minimum, Service Value CMM/W 7.85 Minimum No of Speed 5 , Insulation Class- E, Temperature Rise @ Rated Voltage 25 degree Celcius (Max) by winding resistance measurement at an ambient 30 degree Celcius, High Voltage Test Withstands 1.5KV, Insulation resistance Above 2 MΏ, Type of Ball Bearings Single row deep groove ball bearings of 6202 sizes Top & Bottom Cover should be of aluminium, Type of Lubricant Used Lithium Based – Shell Alvania RL3, Material of Blade Aluminium, BEE Certification, Material of Canopies- Polypropylene, complete all as specified and as directed. Make: BAJAJ Model No Energos 28 or Equivalent Makes in Havells / Crompton Greaves/ Usha / Orient Electric energy star Note: (i) Old/BER Ceiling fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt.”. Cost of Trasportion from work site to MES store shall be assumed to have been quoted in unit rates. (ii) The cost of M&L Connectig wire of suitable size and length from ceiling rose to fan connector shall also be deemed to be quoted rates of item
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.
Point wiring (concealed to surfaces) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as serial item No- 52.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 52.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination 2-in-1, 3-pin, 5 and 15 Amp flush type universal type, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination 2-in-1, 3-pin, 5 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.
T bulb curve, 12 Watt LED base B22 cool day light, complete all as specified and as directed by Engineer-In-Charge.
Stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of MCB, Single Pole and Neutral, 40-63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 95.0 Sqmm, 3.5-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, for foundations/ laying of cables/pipes, complete all as specified and as directed by Engineer-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified.
S&F GI tube, 80 mm bore, light grade with all fittings and MS clamps of suitable size and nuts and bolts, including one coat of red oxide primer and two coats of synthetic enamal paint after preparation of surface, fixed to walls, poles, ceiling or laid in trenches for cable protection, complete all as specified and directed.
S& F Factory made LT electrical panel board in repair outdoor type AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, cubical Outdoor type, fabricated with 3.15mm thick made mild steel sheet /CRCA, powder coated , CPRI Approved , bottom with detachable plates, front and rear with hinged type double door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars 4 Nos, 400 amps capacity insulated with colored PVC sleeves mounted on frame of mild steel angle iron 25x25x5mm, 30Cm above from the ground level duly supported with mild steel angle iron 40x40x5mm, embedded in Plain Cement Concrete M-10 (1:3:6), type C-1 (using 20mm graded crushed stone aggregates) 300mm below the ground level and required masonry in brick work in cement mortar 1:6 incl suitable insulators and separators, holes drilled for connections, complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete all as specified and comprising of the followings:- OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 163 Amps with breaking capacity 16 KA - 01 No. INCOMING :- (d) Change Over Switch, 4 Pole, 415 V, Thermal Magnetic type, 163 Amps- 01 No
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates reduced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
S&F earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 25X4 mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI strip of size 32x6mm with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by 25%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
S&F in replacement of SITC of high-quality integrated LED Street Light with a minimum system lumen of 4950 Lm and system wattage not exceeding 45W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified, complete all as specified. Make : Bajaj cat part No ENXT P 54L WH PO PC SD or Equivalent makes in Crompton/Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
S & F Inverter LED Batten with opal diffuser, IP20, battery back-up & functioning as per product TDS, 20 Watt, complete with all accessories with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. Havells cat part No- PRIDE PLUS INVERTER BATTEN LHEXACP7FN1W020 or Equivalent Makes in Crompton/Philips/Osram.
Replacement of old unserviceable/ damaged Cable and Supply, laying commissioning, testing of the XLPE LT cable 1100 volts grade of size 16 Sqmm 2 core armoured, PVC sheathed with aluminium conductor heavy from existing pole to builing with the help of clamp/shadels etc, complete all as specified and directed.
S&F in replacement of 4 feet highly engineered plastic body suitable with fully diffused diffuser for general lighting in areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2000 nominal lumens and an outstanding solution efficacy of atleast 100 lumen/watt and maximum system wattage of 20 Watts. The electronic driver used shall have a power factor >0.95 and THD <20% with 4 KV internal surge protection. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make : Bajaj cat part No BCLSB 20 WH Bajaj or Equivalent makes in Crompton/Philips. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
Supply, Installation, Testing and Commissioning of all in one integrated LED solar street lighting luminaire with aluminium housing, UV stabilized polycarbonate cover, having minimum system lumen output of 3600 & system wattage not exceeding 30W, with system lumen efficacy not less than 120 lm/W. Luminaire has Integrated MPPT charger with Driver with charger efficiency >90% and should be available in CCT of 5700K. Luminaire should have highly safe & Advanced long life maintenance free Lithium Iron Phosphate (LiFePO4) battery 12.8 V 24 Ah (BIS Certified) along with inbiult PIR sensor with dimming profile. with solar module capacity of 38Wp. Lifetime should be at least 50,000 burning hours at L70 at 25 degree centigrade and backup for 02 days including fixing light and any other necessary connected items for mounting on solar street light poles of directed dia and size and all as per Manufacturer’s instructions and all as specified and directed by Engineer in charge. Make Bajaj/Philips/Wipro. Note : 1. Cost of Solar light pole shall deem to be included in quoted rates. 2.All necessary Earth work as in excavation, returning filling and removal and PCC work with form work and other allied items to complete the Job in all respect shall be deemed to have included in quoted rates and nothing extra shall be paid extra on this aspect 3. Warranty Certificate for 5 years for complete system against manufacturing defects shall be attached with the purchase invoice from the manufacturer.
Supply, Installation, Testing and Commissioning of all in one integrated LED solar street lighting luminaire with aluminium housing, UV stabilized polycarbonate cover, having minimum system lumen output of 2400 & system wattage not exceeding 20W, with system lumen efficacy not less than 120 lm/W. Luminaire has Integrated MPPT charger with Driver with charger efficiency >90% and should be available in CCT of 5700K. Luminaire should have highly safe & Advanced long life maintenance free Lithium Iron Phosphate (LiFePO4) battery 12.8 V 18 Ah (BIS Certified) along with inbiult PIR sensor with dimming profile with solar module capacity of 38Wp. Lifetime should be at least 50,000 burning hours at L70 at 25 degree centigrade and backup for 02 days including fixing light and any other necessary connected items for mounting on solar street light poles of directed dia and size and all as per Manufacturer’s instructions and all as specified and directed by Engineer in charge. Make Bajaj/Philips/Crompton Note : 1. Cost of Solar light pole shall deem to be included in quoted rates. 2.All necessary Earth work as in excavation, returning filling and removal and PCC work with form work and other allied items to complete the Job in all respect shall be deemed to have included in quoted rates and nothing extra shall be paid extra on this aspect 3. Warranty Certificate for 2 years for complete system against manufacturing defects shall be attached with the purchase invoice from the manufacturer.
Amount of Schedule of credit of for Rs 50,714.00 shall be deducted from quoted amount.
CHOPRA CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .