SO-1(Wks), HQ IGAR(N) C/O 99 APO
Maint operation of 01 No 50 KWP Solar Plants installed at AR Bn at Kohima
2022_ARMHA_713932_1
VIII.11001/EngrMNO/2022-23
Open Tender
Civil Works
Works
Kohima
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
SO1 (Wks), HQ IGAR (N), C/O 99 APO of SBI
₹15,500
Yes
30 Nov 2022
22 Sept 2022
11 Oct 2022
22 Sept 2022
10 Oct 2022
23 Sept 2022
22 Sept 2022 - 6 Oct 2022
Amount
SCHEDULE ‘A’ PART-I (MANNING & OPERATION
Maint/Manning and operation of 01 Nos of 50 KWP Solar Power Plant along with its connected equipments i.e. control panels, battery banks and PV modules etc in shift of 08 hrs per day by employing qualified or experienced technician including comprehensive maintenance of all above equipment installed at solar distribution network in AR Bn Kohima main office & Sig cente area by maintaining attendance register of staff employed all as specified and directed by Engr-in-charge. Contractor shall quote his rates for manning/ maint and operation of 01 No Solar Power Plant and all other eqpt including cleaning of plant areas, monitoring/ recording of energy production/ distribution details with following terms and conditions :- (a) Contractor will produce character certificate issued by Police Station, education/ qualification certificate and experience certificate belonging minimum 02 years of the staff employed and contractor shall be responsible for any disciplinary case of staff employed (b) Necessary life insurance will be done as per prevailing rules for tradesman employed through the job and the original policy documents will be produced for verification and record of the accepting officer immediately on after approval of technician (c) All expenditure for necessary T&P, Dress, Safely hardness Eqpt, comn, stationery, insurance of tradesman etc as per specified in this job are deemed to be included in the quote rate (d) All payments of labours will be done through Nationalized Banks and produced the bank statement to department before claiming bills. (e) PENAL CHARGES :- If any of the activity above is not performed by the contractor than recovery as under will be affected :- (i) Absent on duty of Technician – Rs 1000 per shift (ii) Not cleaning of PV Modules and Plant Areas - Rs. 2500 per plant month Note :- The spares replaced under comprehensive maintenance shall be measured and paid separately.
Supply, installing, testing and commissioning of Array Junction Box (AJB) as per existing size/capacity complete all as directed and specified
Supply installing, testing and commissioning of Field Junction Box (FJB) as per size/capacity complete all as directed and specified
Supply, installing, testing and commissioning of Main Junction Box (MJB) as per existing size/capacity all as directed and specified
Supply, installing, testing and commissioning of PV Modules (Photo-Voltaic Cell) as per existing size/capacity complete all as directed and specified
Supply installing, testing and commissioning of PV circuit breaker PC Box of 250 Amp capacity complete all as directed and specified
Supply, installing, testing and commissioning of DC/AC Voltage meter as per existing size/capacity all as directed and specified
Supply, installing, testing and commissioning of DC/AC Ampere meter as per existing size/capacity complete all as directed and specified.
Supply, installing, testing and commissioning of Solar E/fax as per existing size/capacity complete all as directed and specified
Supply, installing, testing and commissioning of Solar DC cables of 6.00 sqmm complete all as directed and specified
Repair & maint of old existing inverter of system voltage 240/360/480 volts by inspecting, repair of replacement of internal part complete along with DC wiring connection PCBs, indicators volts & Amp meters (Digital/Analogue type) and make the inverter functional by connecting to existing battery bank all as specified and directed. Note:- If the inverter is non-repairable then the same shall be replaced with hybrid type inverter of suitable capacity wrt existing system voltage@ Rs. 14,50,000/-
Fixing only battery bank of suitable capacity (600 AH) from store room to solar plant site and connecting in existing system by taking down old unserviceable battery bank from system complete & make the plant functional in all respection including connection upto inverter complete all as specified & directed Note:- (a) The new battery bank (500/600/1000 AH) will be supplied as schedule ‘B’ stores free for fixing only. (b) The old battery bank is issued as scheduled of credit to the contractor. (c) The battery bank qty is 180 or 240 Nos
GAUTAM ENTERPRISES
Aien Meren Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .