Loading…
Loading…
Tender ID
Tender Value
₹5.7 L
EMD Value
₹15,000
Closing Date
15 Sept 2025, 11:00 pmClosed
Rural Drinking Water and Sanitation Department
mescom
RWSSD/2025-26/EL/WORK_INDENT9431/CALL-2
RWSSD/2025-26/EL/WORK_INDENT9431/CALL-2
Open
Electrical
Electronic Documents, First(One Cover)
RWSSD Division Office Shivamogga
₹500
₹15,000
8 Sept 2025
8 Sept 2025
13 Sept 2025
Providing FHTCs to 136 households in KOODI habitations of KOODI village Shivamogga taluk Shivamogga District through Augmentation & Retrofitting from SVS to PWS of KOODI in Shivamogga taluk Shivamoggadistrict(LPCD 55)
02 79 112-Double Pole TC sets for erection of 25/63/100kVA 4/5 Star Rated Transformers using 9 mtr RCC Pole 145Kg WL - MS
Erection of Transformer structure Upto 25/63 KVA - Ordinary Soil
02 00 105-RCC Pole-9.0M
Digging of Pits 1.8 mtr depth for errection of 9 to 10 mtr Long Steel/ RCC/PSC supports as per approved Drawing - Ordinary Soil
Erection of RCC poles 9 to 10 mtr long but in a pit of 1.8 mtr depth. - Ordinary Soil
02 83 007-11kV Pin Insulator (Both Shell and G.I. Pin) - Polymeric
Earthing Material Set
Digging of pit. For providing GI Pipe type Earthing - Ordinary Soil
Providing GI Pipe Earthing for lightning arresters Transformer Neutral and Transformer Metal parts (Excluding digging of pits) - Ordinary Soil
02 81 008-8 SWG GI Wire
03 21 465-25kVA, Aluminum
Wdg, Star 2 (5 Star)-Distribution Transformers - 3
Phase,11kV/433V - Stacked Core with Oil
Erection of 25 kVA Transformer on Transformer structure. - Ordinary Soil
Polymeric type with GROUND DISCONNECTOR
Fixing of lightning arrestors including wiring. - Ordinary Soil
02 84 108-Rabbit ACSR
Stringing of conductor Rabbit ACSR binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps. - Ordinary Soil
02 00 006-PSC Pole-9.0M
Digging of Pits 1.8 mtr depth for errection of 9 to 10 mtr Long Steel/ RCC/PSC supports as per approved Drawing - Ordinary Soil
Erection of PSC poles 9 to 10 mtr long but in a pit of 1.8 mtr depth. - Ordinary Soil
11 kV Horizontal Cross Arm with single top support, clamp, Bolt & Nuts with washers for RCC Poles - MS
Fixing of V-Shape/Horizontal cross arm including single top support Braces and Insulators fixing. - Ordinary Soil
02 83 007-11kV Pin Insulator (Both Shell and G.I. Pin) - Polymeric
02 83 320-Silcon rubber composite disk insulator/11kV 45 kN Polymeric insulator
Special 3 Pin Cross Arm, clamp and Bolt & Nuts for RCC Poles -GI
Fixing of 3 pin special cross arms with clamps, bolts, nuts and washers - Ordinary Soil
Guy set with No.15 strain insulator & Concreting materials as per Drwg No.BESCOM/GM/CP/7/Dt; 24.10.07
Digging of Pit for GUY SET - Ordinary Soil
Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) - ...
Releasing and Refixing-Rabbit ACSR Conductor - Ordinary Soil
Releasing and Refixing-4 Pin Cross Arm with pole clamp, bolt & nuts & washers for PSC Pole - MS - Ordinary Soil
02 00 003-PCC Pole-8.0M
Long 140 kg WL
03 57 515-LT Three phase Four Wire 5-30A Thread through type composite Meter Housing Box consisting of ETV Meter with AMR comply and LTCT with built in GSM/GPRS modem upto 100kVA Distribution Transf...
02 00 103-RCC Pole-8.0M
Digging of Pits 1.5 mtr depth for errection of
7.5/8 mtr Long Steel/RCC/PSC/PCC supports as per approved Drawing - Ordinary Soil
Erection of RCC poles of 7.5 to 8 mtr long in pit of 1.5 mtr depth - Ordinary Soil
4 Pin Cross Arm with pole clamp, bolt & nuts & washers for RCC Pole - MS
Fixing of 4 Pin cross arm with insulator and Braces fixing. - Ordinary Soil
Guy set with No. 8 strain insulator & Concreting materials as per Drwg No. BESCOM/GM/CP/7/Dt; 24.10.07
Digging of Pit for GUY SET - Ordinary Soil
Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) - ...
02 84 108-Rabbit ACSR
Stringing of conductor Rabbit ACSR binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps. - Ordinary Soil
02 83 158-No8 Strain Insulator
Single Break GOS
Fixing of GOS including wiring g (11kV SB 200A) - Ordinary Soil
03 02 122-HG Fuse 11KV
Class Solid Core Type
Fixing DOLO cutouts / Horn Gap Fuses including fixing of cross arms and wiring - Ordinary Soil
03 01 107-LT Protection kit
Fixing of LT Protection Kit - Ordinary Soil
03 01 151 L.T.Wiring kit For 25 kVA DTC single circuit
Wiring of One circuit of LT Wiring Kit for for25/63/100 KVA DTC to the existing LT protection KitKit / Distribution Box via metering box. - Ordinary Soil
Electrical Inspectorate Charges ( @ 0.00 Amount of ())
Goods and Service Tax (GST): CGST , SGST, IGST (
@ 18.00 Percentage of (Labour + Works + Stock Materials ))
Area Specific Loading(@5% Mejor Irrigation Command Area/Mining Area/Major Industries/Corporation LImits Of Tier-2 Cities) ( @ 5.00 Percentage of (Labour + Works + Stock Materials ))
Supervisions,Security Deposite,GST and other charges
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .