| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹14.8 L+₹1.1 L (8.17%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹14.8 L+₹1.1 L (8.23%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹15.4 L+₹1.7 L (12.5%)Rejected-Finance | L4 | Rejected-Finance Being not L1 |
Tender Value
₹16.0 L
EMD Value
₹31,980
Closing Date
28 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
MAINT OF HT ELECTRIC SYSTEM UNDER AGE E/M WEST AREA, JALAHALLI
2022_MES_559814_1
85234/E8
Open Tender
Civil Works
Item Rate
180 days
GE (M) (AF) Jalahalli
As per tender documents
7 documents required · 7 mandatory
₹500
GE (M) (AF) Jalahalli
₹31,980
20 Jan 2023
26 Oct 2022
30 Nov 2022
26 Oct 2022
28 Nov 2022
16 Nov 2022
26 Oct 2022 - 9 Nov 2022
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in soft/ loose soil all as directed.
Excavating in trenches not exceeding 1.5m wide and exceeding 1.5m in but not exceeding 3.0m depth for laying of cable, foundation etc, and getting out in soft/ loose soil all as directed.
Returning filling in including spreading, levelling Watering and well ramming in layers not exceeding 25cm all as directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
M& L for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles all as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness of 18cm only will be considered for paymet.
Supplying & laying reinforced precast concrete cable cover, class HV,Type 1, flat, size 300 mm x 180 mm x 40 mm abetting Each other with gap between adjacent slab not exceeding 10mm for protection of cables all as specified and as directed.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including old removed earth to be refilled and top surface to matched with existing surface by means of PCC 1:3:6, type C1 using 20mm graded stone aggregate to matching with the surroundings all as directed.
Dismantling concrete pole / Steel pole / struts of any size all as directed.
Supply and fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts nut and screws as specified type 410 SP-55 (11.0 meters long) including two coats of aluminium paint over a coat of red oxide primer all as specified and as directed. Note : Necessary earth work excavation, removal of surplus soil & concrete shall be measured and paid separately in respective items.
Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate for foundations / filling around the post all as specified and as directed.
Material and labour for plain cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate for path ways, hard standing & pole coping including necessary form work and applying two coats of white wash on exposed surfaces etc complete all as specified
Dismantling of unserviceable cross arm such as MS channel /angle section etc complete all as directed.
Material and labour for cross arms, bracings, supports, clamps and back plates, fabricated from structural steel including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed inclusive of one primer coat, one under coat and one finishing coat of aluminum paint all as specified and as directed.
Dismantling insulators of any type and size all as directed.
Material and labour for pin type, porcelain vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for 11000 volts grade all as specified and as directed.
Dismantling air break gang operated switches vertical/horizontal mounted with two or three insulators per phase including insulators and operating mechanism for repair/ replacement of broken/worn out components all as directed.
Material and labour for switch air break, gang operated triple pole, mechanically operated (with GI operating rod), mounted on insulator and steel frame with operating mechanism worked from ground level, vertical type for current rating upto 200 Amps on HT 11000 volts working pressure, including locking arrangement with 06 lever lock and painting the steel surfaces with two coats of synthetic enamelled paint over a coat of red oxide primer etc all as specified and as directed.
Material and labour for switch air break, gang operated triple pole, mechanically operated (with GI operating rod), mounted on insulator and steel frame with operating mechanism worked from ground level, vertical type for current rating upto 400 Amps on HT 11000 volts working pressure, including locking arrangement with 06 lever lock and painting the steel surfaces with two coats of synthetic enamelled paint over a coat of red oxide primer etc all as specified and as directed.
Repair / service / overhauling of gang operating devices 11000volts upto 400 Amps including greasing all the moving parts and applying white petroleum jelly at the contact points, tightening all nuts and bolts and prividing PG clamps 06 Nos, additional nut and bolts commissioning and testing complete including dismantling and replacing all the unserviceable parts / spares all as specified and as directed. Note: All the spares replaced shall be measured and paid separately under relevant Items
Supply only moving contact blades
Supply only fixed contact jaw copper
Supply only copper braded tape (Thinner copper flexible jumper)
Supply only mild steel supporter
Supply only back connected plate
Supply only jumper carrier
Material and labour for replacement of expulsion / drop out / horn gap type fuse carrier assembly outdoor type 200Amps capacity upto 25 Amps including insulators and fuse element conforming to IS specifications suitable for 11000 volts (HT) all as specified.
Material and labour for replacement of expulsion / drop out / horn gap type fuse carrier assembly outdoor type 200Amps capacity above 25 Amps & upto 50Amps including insulator and fuse element conforming to IS specifications suitable for 11000 volts (HT) all as specified and as directed.
Material and labour for lightning arresters for outdoor use expulsion type suitable for 11000 volts (HT) complete with all fittings, transmission class, dis-charge capacity 65 KA including taking down existing lightening arresters of any type and size all as directed.
Supply, lay, test and commissioning of XLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured, heavy duty electric power cable (HTUG), 11000 volts grade with stranded aluminium conductor of size 3 core 95 Sqmm ( Earthed) including takingout existing unserviceable cable all as specified and as directed.Note - Rates are included with Megger testing of Cable.
Supply, lay, test and commissioning of XLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured, heavy duty electric power cable (HTUG), 11000 volts grade with stranded aluminium conductor of size 3 core 120 Sqmm ( Earthed) including takingout existing unserviceable cable all as specified and as directed.Note - Rates are included with Megger testing of Cable.
Supply, lay, test and commissioning of XLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured, heavy duty electric power cable (HT UG), 11000 volts grade with stranded aluminium conductor of size 3 core 185 Sqmm ( Earthed) including takingout existing unserviceable cable all as specified and as directed.Note - Rates are included with Megger testing of Cable.
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed.
All as per item No. 32.00 described here-in-before but 3 core 95 Sqmm
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed.
All as per item No.34 described here-in-before but 3 core 95 Sqmm
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for out door straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed.
All as per item No. 36.00 described here-in-before but 3 core 95 Sqmm
Supply and fix galvanised iron tubing light grade 100mm bore galvanized with all fitting laid in trenches / road crossing for UG cable protection all as specified and as directed.
All as per item No.38.00 described here-in-before but 150mm dia pipe
Material and labour for jumper connections between GOD and drop out fuses and transformers with ACSR conductors of suitable size and length (Weasel) including necessary lugs wherever required / aluminium heavy duty PG clamps / binding properly without any loose contact after removing the old jumpers including PVC sleeves all as specified and as directed.
Material and labour for repair of HT 11 KV Four pole structure by replacing galvanized PG clamps, GI bolts and nuts, tightening of ACSR conductor with insulation of any size as jumpers and cleaning of all disc /pin insulators and applying silicon compound for prevention of arcing due to dust/ salt deposits over the surfaces including applying one coat of red oxide primer on rusted portions after preparation of surfaces &applying a coat of aluminum paint to the entire steel structure over two coats of white wash on exposed portion of cement concrete surfaces complete all as directed. Note: Quoted unit rate shall be inclusive of PG clamp for jumpering, GI hardware like nuts, bolts two coats of white wash on exposed concrete surfaces, etc complete all as directed by Engr in Charge
All as per item No: 41.00 described here-in-before but two pole structure
Material and labour preparing old faded painted surface of 11 metre long steel tubular pole complete with including all accessories such as cross arms bracings, brackets etc, and applying two coats of aluminium paint including writing pole number with paint same as existing earlier all as specified and as directed.
Labour only for dismantling transformer step down out door type 11KV/433 Volts of capacity 100 to 315 KVA by disconnecting incomig /outgoing cables and ACSR jumpers, opening top end of thed unit by unscewing nuts/bolts washers all as directed for replacement of unsv parts and reassembling including reconnectios of incomers and out going connections (work includes replacement of gasket seal,draining out/refilling of transformers oil, rusted /unsv nuts bolts with washers and general cleaning of transformers inner chamber by removing accumulated sludge etc at bottom before refixing and rates quoted will be deemed to includes for the same.works. Notes:- The transformer repair works shall be carried out only by engaging specialised and experianced technicans. The oil shall be filterd before refilling if found required. The charge for filteration will be measured and paid separately.
Supply and replace defective LT porcelain bushings complete of transformer step down out door type 11KV/433 Volts of capacity 100 to 315 KVA any make/ size/ type all as specified and as directed .
Supply and replace defective HT porcelain bushings complete of transformer step down out door type 11KV/433 Volts of capacity 100 to 315 KVA any make/ size/ type all as specified and as directed .
Supply and replace defective LT bushing rod made out of gun metal with threading & of suitable length/ size all as per existing including metal rings/ bolts/ washers/ rubber rings etc complete of transformer step down out door type 11KV/433 Volts of capacity 100 to 200 KVA any make/ size/ type all as specified and as directed
Supply and replace defective HT bushing rod made out of gun metal with threading & of suitable length/ size all as per existing including metal rings/ bolts/ washers/ rubber rings etc complete of transformer step down out door type 11KV/433 Volts of capacity 100 to 200 KVA any make/ size/ type all as specified and as directed
Supply and replace defective silica gel breather assembly for HT distribution transformers of 100 KVA to 315 KVA capacity including dismantling old one all as specified and as directed
Supply and replace defective gun metal drain valves of transformers from 100 KVA to 315 KVA capacities including dismantling old one all as specified and as directed.
Supply and replace defective (OTI) Oil Temperature indicator from 100 to 315 KVA capacity distribution existing transformers including dismantling old one all as specified and as directed
Note :- Labour charge for item Sel No 45 to 51 will be includes in item No- 44 here in before.
All asp per items No- 44 but after removing transformer to authourized HT electrical workshop by lorry transport for inspection and rewinding ,replacement of defective parts ,rewinding of HT/LT coils as found necessary and refilling of oil after dehudification /filteration,testing and submission of test reports after repairs /overhauling and reinstallation of the transformers in original location with complete incoming /out going cable connections etc (cost of replasing defective parts and rewinding with copper enameled conductor of appropriate grade will be measured and paid separately ) Note - Rates includes provision of mobile crane unit for lifting /loading of the transfromer at site & workshops)
Supply and replace defective terminations/ connections inside the transformer.
Note:- (i) Any damage to insulators/ bushes/ windings etc. while in the custody of the contractor shall be made good at no extra cost to govt. The serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody.(ii) M&L for rewinding/ re-insulation of HT/ LT (primary/ secondary) coils, bushes, studs, Transformer oil,cable box, replacement of buchholtz relay/ MOG if any etc will be measured and paid separately.
Rewinding of HT coils with copper wire / strips DPC / super enameled copper winding wire match with existing gauge or as recommended by the manufacturer for turn ratio and impedance including requisite paper / insulation material in Each layer of winding complete all as specified and as required
Testing of di-electric strength i.e BDV test for 60 Sec with stand the transformer oil of any capacity to authorised value 45 to 60 KV using standard oil test kit as per result as IS 335-1972 complete all as specified and directed. Note :- a) The rate quoted shall be deemed to include for arrangement of standard testing kit . (b) The dielectric strength value of the transformer oil shall be tested before filtration. (c) Sample of oil to be collected and testing to be done transformer site. (d) Testing to be done with gap seting - 2.5 mm , tempreture setting on ambient and frequency with 50 cycle (e) Test reports shall be enclosed at the time of payment.
Filtration of transformer oil of transformers installed at various locations to achieve di-electric strength not less than 60 KV for 1 minute at 2.5 mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as directed. Note :- a) The rate quoted shall be deemed to include for taking necessary conections to filteration plant from transformer and switch gear oil duly removing the inlet and out let connections. (b) Electric supply for the filteration plant will be made available free of cost. (c) The dielectric strength value of the transformer oil shall be tested affter filtration as specified and directed. (d) Test reports shall be enclosed at the time of payment.
Material and labour for preparation of old painted surfaces of 100 to 315 KVA capacity indoor / outdoor type transformers with coarse cloth/ brush and painting throughout externally on exposed surfaces with two coats of smoke grey colour synthetic enamel paint or approved colour as directed including writing of SM/MES Number on transformer and transformer details on plinth in white enamel paint on black enamel paint back ground complete including one coat of white wash for base foundation all as specified and directed by Engineer-in-charge.
Taking down HT switch gear (Vacuum circuit breaker ) of capacity 400 to 800 Amps, 11 KV 250 to 450 MVA and strip opening the HT panel of rating 11 KV, 3 phase comprising of following repairs, overhauling, servicing and refixing the same after repairs/ overhauling:
(a) Tripping off the breaker, lowering the breaker with raising/lowering handle and pulling out the breaker complete from the panel along with the trolley for servicing/inspection/overhauling
(b) Servicing/Inspecting/checking of automatic safety shutter operation for serviceability and replacement of spares if required.
(b) Servicing/Inspecting/checking of circuit spout and cicuit spout connections for RYB phases and replacement of spares if required.
(c) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc.
(d) Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism.
(e) Servicing/Inspecting/checking of secondary sockets/busbar earthing plugs/earthing sockets and replacement of spares if required.
(f) Checking, setting and adjustment of lowering and raising operation of the breaker trolley.
(g) Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with vacuum interrupter assembly.
h) Dismantling the complete instrument chamber/ HV cable box/LV cable box .Decarbonising/ cleaning the complete HT 11 KV 3 phase independent bus bar, bus bar chamber of HT panel and inspecting the bus bar insulators.
j) Checking, inspecting, calibration of relays, ammeters and voltmeters etc complete.
k) Checking complete electrical tripping circuit of HT panel including control wiring from secondary system rotary to tripping coil, auxiliary switch male and female housing cut out, etc. and wiring including replacement of damaged wire at places including operation on DC system, testing and commissioning complete all as directed.
m) Inspection of PTs and CTs
p) The inspection of HT switch gear shall involve:- (i) Inspection of truck & hoist assembly. (ii) Inspection of tank assembly & barriers. (iii) Inspection of assembly & components of solenoid assembly. (iv) Inspection of assembly & components of dependent mechanism. (v) Inspection of assembly & components of spring box mechanism. (vi) Inspection of motor mechanism spring charge assembly (vii) Inspection of assembly of trip unit & related components m) Testing function of Vaccum interupter (Vaccum Bottle ) of VCBs by testing equipement and inspecting of housing and insulators complete testing certifiacte to be submit to office.
Notes: (i) The rate quoted shall be deemed to include for necessary T&P, minor spares like nuts, bolts, washers, gasket, insulation tape, lugs, compound, copper wire, sealent provide to lid/opening of cable gaps etc. to put in to the VCBs /HT panels in serviceable condition, testing and commissioning all as specified (ii) Rates for items No 59 to 60 shall be paid separately against respective items.
Supply and replace the Shunt trip coil 110 V DC/220 V DC /30 V DC suitable for 400 to 800 Amps 250 MVA to 450 MVA HT switch gear (VCBs) of any make and 11 KV HT panel complete all as directed.
Supply and replace the HRC fuse (PT HT side) any make suitable for 11 KV HT panel complete all as directed.
Supply and replace the Current transformer of ratio 11000/110V any make suitable for 400 to 800 Amps 250 MVA to 450 MVA HT switch gear (VCBs) of any make and 11 KV HT panel complete all as directed.
Supply and replace the Space heater any make suitable for HT switch gear (VCBs) of any make complete all as directed.
Supply and replace the Trip Free Mechanism suitable for 400 to 800 Amps 250 MVA to 450 MVA HT switch gear (VCBs) of any make and 11 KV HT panel complete all as directed
Supply and replace the Closing coil suitable for 400 to 800 Amps 250 MVA to 450 MVA HT switch gear (VCBs) of any make and 11 KV HT panel complete all as directed
Supply and replace the Auxilary switch 4 NO + 4 NC suitable for 400 to 800 Amps 250 MVA to 450 MVA HT switch gear (VCBs) of any make and 11 KV HT panel complete all as directed
Supply and replace the TNC switch suitable for HT switch gear (VCBs) of any make and 11 KV HT panel complete all as directed
Supply and replace the Shower contact assembley suitable for 400 to 800 Amps 250 MVA to 450 MVA HT switch gear (VCBs) of any make and 11 KV HT panel complete all as directed.
Supply and replace the brass nut suitable for Shower contact assembley of 400 to 800 Amps 250 MVA to 450 MVA HT switch gear (VCBs) of any make and 11 KV HT panel complete all as directed.
Supply and replace the Vacuum interrupter of capacity 12KV,1250A with KA with, rings and End rod insulators, suitable for 400 to 800 Amps 250 MVA to 450 MVA HT switch gear (VCBs) of any make and 11 KV HT panel complete all as directed
Supply and replace the VCB Housing of suitable capacity 12KV,1250A with KA with including separator shutter suitable for 400 to 800 Amps 250 MVA to 450 MVA HT switch gear (VCBs) of any make and 11 KV HT panel complete all as directed
Disconnection and taking out of the IDMT/digital relay, three element type of any make or equivalent in model from HT panels consisting of the following :- (i) Cleaning of relay & contacts (ii) Calibration of relay by conducting secondary injection tests. (iii) Checking of CTs (iv) Rectification of defects in control wiring, if any (v) Adjustment/ setting of plug and time multiplier (vi) Setting of the relay to achieve the discrimination in tripping. (vii) Tuning of up stream breaks (viii) Re-installation of relays including testing.
Supply and fixing of Over current & Earth fault Protection numerical IDMT relay suitable for existing suitable for 11KV ring main unit & feeder protection of any make with Aux suuply,CT current,internal battery ,USB port ,cold load pickup circuit bearker protection ,potential free alarm contacts ,last 5 fault and 10 event record with time stamp , LCD display ,USBs Communication etc all as per standard IEC-60255, EN-65000 and IEC-255 and relay having following protection features complete all as directed. Make - C&S/Seimens/ABB (i) Relay having three phase definite time over current and short circuit protection current with varriable times ,three phaes over current protection with short circuit protection with variable tripping times ,define time and inverse time earth over current protection,circuit breaker protection. (ii) protection blocking through DI (ii) three phase tiem over current protection (iv) Three phase instantaneous protection.(v) earth time over current and earth instantaneous over current (vi) circuit breacker failure detection (vii) trip circuit supervision
Repair / servicing and Checking the HT 11KV, Capacity 400 Amps, out door type, Ring main unit (RMU) having 04 nos breakers ,tripping circuit and resetting trip values and the nuemerical relays and checking tripping machanism servicing the LBS fully , indicator wiring setting of chage spring by engaging well experianced technicians as per manufacturer recommendation and all as directed.Note: Spare parts shall be measured and paid separately under relevant items :
Supply and replace the Bushing 400 Series Bolted Type HT 11KV, Capacity 400 Amps, out door type, Ring main unit (RMU) complete all as directed.
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. including excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm 3 core. The fault locating equipment will be brought to site within 02 hours of instruction received from Engineer-in-Charge complete all as specified and as directed.
Notes: (i) The rate quoted shall be deemed to include for necessary T&P, minor spares like nuts, bolts, washers, gasket, insulation tape, lugs, compound, copper wire, sealent provide to lid/opening of cable gaps etc. to put in to the VCBs /HT panels in serviceable condition, testing and commissioning all as specified (ii) Rates for items No 59 to 60 shall be paid separately against respective items.
Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised earth strip of size 25x4 mm (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, checknuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20 mm bore medium grade, wire nuts and lugs including taking down old u/s one complete all as specified and as directed.
Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including copper earth strip of size 20x3 mm (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, checknuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No.3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs including taking down old u/s one complete all as specified and as directed.
M&L for Copper earth strip of size 20x3 mm in ground not exceeding 40cm deep / fixing to wall / pole structure including taking down old strip complete all as specified and as directed.Note :- (i) Excavation for laying of Earth strip to be paid in respective items (ii) Cost of insulator /PVC pipe for protection of pipe and other accessories for fixing of earth strip to pole structure to be includes in items rates.
M&L for GI earth strip of size 32 x 6 mm in ground not exceeding 40cm deep / fixing to wall / structure including taking down old strip complete all as specified and as directed.
M&L for GI earth strip of size of 25 x 4 mm in ground not exceeding 40 cm deep / fixing to wall / structure including taking down old strip complete all as specified and as directed.Note :- (i) Excavation for laying of Earth strip to be paid in respective items (ii) Cost of insulator /PVC pipe for protection of pipe and other accessories for fixing of earth strip to pole structure to be includes in items rates.
Material and labour for danger notice plate of 1.6mm thick mild steel sheet with vitreous enamelled with letter figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT, 25 x 20cm all as directed and as specified.
M&L for painting with two coat of synthetic enemelled paints over a coat of red oxide including perparation of new steel surface and chain link fencing complete all as specified .Note - Colour of paint will be approved by Engineer in Charge.
Surface excavation not exceeding not exc 30 cm deep and avarage 15 cm deep and getting out in hard/dence soil /hard core including removing the excavated and removing grass/weeds/hard cement concrete /stone etc and levelling neatly the excavated area for substation yard/providing PCC path etc complete all as specified and directed. Note - The rates shall be deemed to includes the cost of removing two time the grass,weeds,debris,excess soil etc to a distance not less tha 50 M and keeping the excavated surface clean and levelled all as directed.
Supply and spreading stone aggregate of size not exceeding 40 mm spread and leveled in layers not exceeding 15 cm to a true surface of broken stones for transformer and pole structure area all as directed
devan enterprises
Forge Engineering & Electricals
RAMESH BABU CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .