Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC P 45 JOGENDRA GARDEN KOLKATA 700078 | KOLKATA | WEST BENGAL | 700078 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹39.0 L+₹2.5 L (6.75%)Rejected-Finance TIORKHALI MAHESHGANJ NADIA | NADIA | NADIA | WEST BENGAL | 790804 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹39.7 L+₹3.2 L (8.74%)Rejected-Finance PO CHANDL PS BISHNUPUR DIST SOUTH 24 PGS PIN 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹43.0 L+₹6.5 L (17.7%)Rejected-Finance 8 27 BEJOYGARH JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹44.1 L+₹7.6 L (20.7%)Rejected-Finance ROOM NO B 111 PART III GANESH MURTINAGAR CAPT PRAKASH PETHE MARG CUFFEPRADE CALABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹35.7 L
EMD Value
₹71,400
Closing Date
20 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) KOLKATA
D9 COMMISSARIAT ROAD HASTINGS KOLKATA 700022
ADDN/ALTN TO CONFERENCE HALL AT BASEMENT OF NEW COMMAND BLDG INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2021_MES_469854_1
8778/E8
Open Tender
Coal Works
Item Rate
150 days
GE (FW) Kolkata
Refer tender document
7 documents required · 7 mandatory
₹500
Yes
GE (FW) KOLKATA
₹71,400
Yes
5 Oct 2021
23 Aug 2021
21 Sept 2021
23 Aug 2021
20 Sept 2021
4 Sept 2021
60 days
Amount
SCHEDULE 'A' PART-I (BLDG WORKS) Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness including cover fillets complete all as specified.
Cutting upto a depth of 2.5cm into concrete walls and trimming surface as required, girth exc. 30cm, with or without reinforcement, all as specified and as directed.
Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings, conerting window into door openings etc or cutting out defective brick work for under pinning including providing, fixing and removing shoring cleaning and stacking bricks, removing surplus serviceable bricks, hard core, etc to store and rubbish out exc 50m, complete all as specified and directed
Forming jambs etc to openings (to foregoing item) including cutting, toothing and properly bonding into old work, also facing jointing and pointing to match existing work in cement mortar 1:4 complete all as specified and directed.
Making good under cills or over arches, lintels and bressumers, including all pinning when necessary in cement mortar 1:4 complete all as specified and directed.
Taking down aluminum frame with shutters of any description exc 1.50 sqm but n.exc 4.0 sqm each, complete all as specified.
S&F plates (plain or chequered ) channels, square cut or notched (ordinary and counter sunk ) forming holes, without any attachment of Fe 410W (Gde E-250) quality 'A' complete all as specified.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
S&F for Framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, and for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. (NOTE: Sheet glass shall be measured and paid seperately)
M&L 12 mm thick Toughned glass as in hinged doors, partitions, automatic doors and similar work including cutting to shape, drilling holes required, complete all as specified and directed.
M&L for etching work for toughned glass, as per required design, pattern complete all as specified and directed.
M & L PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in plinth course, coping and similar bands etc incl necessary formwork complete all as specified and directed.
M&L cement concrete 1:3:6 type C2 (40 mm graded stone aggregate) for surface channel, drain etc all as specified and directed.
Extra for forming fair finished channel 30 cm inner girth in cement concrete using extra cement including formsm moulds mitred / stopped ends etc all as specified and directed
M&L second class hardwood clean sawn in scantlings etc all as specified and directed
M&L plywood 12mm thick grade BWR, type BB, fixed with screws to timber or steel frame work, all as specified and directed
S&F Ist class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
S&F Ist class hard wood moulding, as in cornices, pictures, partitions, like as, complete with sectional area exc 13 sqcm and n.exc 25 sqcm, complete all as specified and directed.
M&L 1.5 mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions, all as specified.
M&L french polishing on surfaces of any description width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats, all as specified and directed
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in soft/ loose soil.
M&L for preparation of old surfaces and applying two coats of plastic emulsion paint over a coat of primer after applying 3 mm thick wall care putty on walls after complete removal of existing treatment, all as specified and directed.
S&F Suspended metal grid Ceiling System with mineral fibre acoustic tiles as per following specifications:- a) Ceiling Tiles:- Mineral fibre acoustic tile of 20 mm thickness having sand textured finish with acoustical punchers, bevelled tegular edge and 8mm drop in module size of 600 x 1200mm. Tiles shall have humidity reistance (RH) of 95%, NRC 0.85-0.95 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, Light Reflectance ≥85% as per ASTM E-1477, Colour Pebble White, Fire Performance of Class 0/1 as per BS 476 Part 6/7 b) Metal Grid:- The grid system shall be 15 mm wide T - section white flanges incorporating a 6mm central reveal in white/black colour with mitred ends & “bird’s mouth” notches to provide mitred cruciform junctions colour global white. Grid shall have double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 7.9 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 9.5 kg/m.
(Item No. 82 Contd....) The end details of the cross tee shall be made of pre hardened steel clip fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of 90 gsm as per IS 277 (2003) pre-painted steel with baked polyester paint of 0T bending capability. The ceiling grid sections shall be fixed to ceiling with 6 mm dia GI hangers upto required length by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5mm dia 40 mm long. MAKE OF CEILING GRID : ARMSTRONG, Model: SILHOUETTE 38 or equivalent in GYPROC / USG BORAL / UNISTEEL MAKE OF CEILING TILES: ARMSTRONG, Model: OPTRA or equivalent item in GYPROC / USG BORAL / U TONE)
Providing & Fixing of flocked textile floor covering of nylon 6.6 face fiber with 100% nylon and completely water proof resilient backing. The flooring shall be anti-static with thickness of 4.3 mm and approximate weight of 1.8 kg/sqm of roll form. The carpet shall be completely stain resistant and of a density approx 80 million fibers/sqm (70 million fiber/sq.yd) in the width of 2 mtr. The floor covering shall have fire test EN-13501, Appearance retention hexapod ISO 140-8, friction slip resistance test EN 14041 class D5, sanitised anti-microbial treatment, with resilient water proof backing, anti-allergic which is certified by British allergy foundation, with ten year warrantee. The carpet shall have permanent static control. MAKE: FORBO FLOORING (Model: FLOTEX) or equivalent product in ANALCO / WELSPUN INDIA / RESPONSIVE INDUSTRIES NOTES:- 1)The work should be carried out by the authorised installer of the manufacturer. 2) Synthetic rubber based adhesive shall be used at the time of installation.
SCHEDULE 'A' PART-II (ELECTRIFICATION WORKS) M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 26 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 26 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 26 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
S & F Modular Switch 1 way 6 A, 1 module
S & F Modular Switch 1 way 16 A, 1 module
S & F Modular Socket 6 A- 2/3 pin combined 2 module
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module
S & F Modular blanking plate, 1 module
S & F Modular type White cover plate with frame 3 module
S & F Modular type White cover plate with frame 4 module
S & F Modular type White cover plate with frame 6 module
S & F Modular type White cover plate with frame 8 module
S & F Modular type White cover plate with frame 12 module
S & F Modular type Metal Flush box 3 module
S & F Modular type Metal Flush box 4 module
S & F Modular type Metal Flush box 6 module
S & F Modular type Metal Flush box 8 module
S & F Modular type Metal Flush box 12 module
S&F Ceiling rose three terminals polycarbonate , isolated body complete all as specified and directed.
S&F in repairs surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size incl taking down existing fitting complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
Supply and Fix in repairs recess mounted LED luminaire, of size 600 mm x 600 mm, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 36 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
M&L for sub main wiring with 4 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Five runs of single core 10.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 48 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
Supply and fixing TPN DB, IP 43 protection, double door (premium quality), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE : L&T, Cat No. DBTPN004DD / LEGRAND, Cat No: 507670 / SCHNEIDER, Cat No. A9HTND04 / ABB, Cat No: E-SHDB M4 / PANASONIC, Cat No: BQS 304H / HAGER, Cat No: VYT04DH) NOTES:- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured and paid seperately as "Supply Only". (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer.
S&F MCB (premium quality), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F stainless steel channel cable raceway, 300 mm wide, covered type with all accessories complete all as specified and directed.
SHEIKH ENTERPRISE
UNITED ENGINEERS
MAZUMDER ENTERPRISE
M/S SRINIVASA CONSTRUCTION
MS HORIZEN
UNIVERSAL TRADING CENTRE
JOY RAM ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .