Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹8.4 L+₹87,518 (11.7%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L2 | Rejected-Finance Other than lowest |
Tender Value
₹13.3 L
EMD Value
₹26,520
Closing Date
17 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
GE(U)/PM/D-20/2020-21
2020_MES_343504_1
GE(U)/PM/D-20/2020-21
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
MES contractor enlisted under class E category c(i) having deposited standing security of Rs 50000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹26,520
Yes
17 Aug 2020
8 May 2020
19 Jun 2020
8 May 2020
17 Jun 2020
3 Jun 2020
60 days
Amount
Dismantling the existing water cooled condenser of Cap 15 TR of shell and tube type, from its pipe line and gas connection, repairing the same by replacing the defective copper tubes of 16mm dia, 1500mm length by new one, (No of existing tubes are 92 Nos), Cleaning the shell completely, assembling the new and serviceable tubes including charging and testing for 350 PSI pressure all as specified and directed by Engineer-in-Charge. Note :- (i) The cost of copper tubes shall be measured & paid separately under supply only items. (ii) Labour charge for taking down & refixing of 'Supply only' items are deemed to be included in the quoted rate.
Supply only of copper tube thickness of 1.41mm (17 SWG), dia 16mm and length 1500mm of best quality ISI marked or BIS certified all as specified & directed by the Eingr-in -Charge. Note :- The labour charges for fixing is included in Sch 'A' item No. 1 above.
Disconnecting and dismantling the burnt squirrel cage induction motor of capacity 40HP, 3 phase, 415Volts, 1450 RPM of any make from its base and transporting the burnt motor to the contractors workshop to carryout the following repairs:- (a) Opening the side covers and removing the rotor and cutting/removing the burnt winding from the stator. (b) Cleaning the stator slots carefully. (c) Re-winding the stator using the super enameled copper winding wire with same no.of coils with same no. of turns/coil as per the data acquired from the old burnt coil. The size of the winding wire should be same as the old coil. Coils should be properly insulated from the core using insulating paper. Coils should be properly tied using cotton tape including insulating with shellac varnish. (d) Testing the continuity of the coils and ensure that no current passing through the stator core. (e) Dynamic testing of the rotor and alignment of the main shaft and ensure that no imbalance vibrations. (f) Re-assembling the rotor and connecting the end terminals to the terminal plates of the motor and closing the ends with side covers and transporting the motor to the original site. (g) Testing and commissioning the electric motor connecting to the electric supply to its full load by connecting the compressor. (Note:- Quoted rates is deemed to include the cost of bolts/Nuts, Sleeves, Terminal plates etc.)
-ditto- all as per Srl item No. 3 above but of capacity 30HP.
-ditto- all as per Srl item No. 3 above but of capacity 20HP.
-ditto- all as per Srl item No. 3 above but of capacity 7.5 HP to 10HP.
-ditto- all as per Srl item No. 3 above but of capacity 3HP to 5HP.
-ditto- all as per Srl item No. 3 above but of capacity 1HP.
Opening the existing cover of water stainer, taking out and cleaning chocked filter and re-fixing it in original position and closing the cover including testing for any leakage all as specified and directed by Engr-in-Charge.
Disconnecting centrifugal Mono block pump from foundation, repairing the same by replacing the defective, shaft, bearing / bush / mechanical seal by new one, assembling, connecting, testing & commissioning of following capacities :-
Monoblock pump of cap 7.5HP to 10 HP.
Monoblock pump of cap 3 to 5 HP.
Monoblock pump of cap 1HP.
Supply and fixing in repairs of gun metal impeller to 5HP/ 7.5HP capacity centrifugal pump set as per existing model and make including neccessary connecting accessories complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs of auto capacity regulator solenoid valve 220V, 50 Hz including connecting to inter rack with nut bolts, washer etc complete all as specified and directed by Engineer-in-Charge. (Make :- M/s Accel/ Totex/ Avcon.
Supply and fixing in repairs of thermostatic expansion valve suitable for existing AC Plant including cutting, welding, brazing, replacement of new gasket, nut bolt, washer etc all as specified & directed by Engineer-in-Charge, Make : Sporlan/ Danfoss or equivalent make as approved by Accepting Officer. Note:- Before disconnecting the existing expansion valve from the system, the refrigerant has to be pumped down or taken in empty cylinder by help of ICE etc and the cost of doing so shall be deemed to be included in the quoted rates.
Supply and fixing in repairs of temeperature gauges of the chiller and condenser lines which operates by mercury liquid of range 0-50⁰C complete all as specified and directed by Engineer-in-Charge. Make : Fiebig / H guru / AE.
Supply and fixing in repairs of 80 mm dia cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 complete all as specified and directed by Engineer-in-Charge. Make : Audco / Advance / Castle/ Zoloto/ Leader.
Supply and fixing in repairs of 100 mm dia cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 complete all as specified and directed by Engineer-in-Charge. Make : Audco / Advance / Castle/ Zoloto/ Leader.
Supply and fixing in repairs 125 mm dia cast iron butter fly valves lever operated SS disc type nitrile/EPDM rubber lining PN 16 complete all as specified and directed by Engineer-in-Charge. Make :Audco / Advance / Castle/ Zoloto/ Leader.
Supply and fixing in repairs of 25 mm dia Ball valve cast iron screwed female ends complete all as specified and directed by Engineer-in-Charge.. Make : Audco / Advance / Castle/ Zoloto/ Leader.
Supply and fixing in repairs of 20 mm dia Ball valve cast iron screwed female ends complete all as specified and directed by Engineer-in-Charge. Make : Audco / Advance / Castle/ Zoloto/ Leader.
Supply and fixing in repairs of Shaft seal assembly suitable for compressor model No. SMC 8-65 / 4-65 of Make M/s Accel complete all as specified and directed by Engineer-in-Charge.
Pump down of refrigerant into empty cylinders of compressor, flushing of the circuit with Nitrogen gas, pressure testing for leakage detection, repair the leakage and vacuumisation of the circuit, refilling refrigerant including replacement of minor parts such as nuts, bolts, washers, etc. as required complete all as specified and directed by Engineer-in-Charge.
Checking the interlocking control panel wiring of main chiller AC Plant of capacity 15 TR to 22.5 TR and making it fully serviceable with and including replacement of all size of wires, thimble, PVC backlight and connection plate, nuts, bolts, washers, etc. as required complete all as specified and directed by Engineer-in-Charge.
Checking the interlocking control panel wiring of main chiller AC Plant of capacity 30 TR to 60 TR and making it fully serviceable with and including replacement of all size of wires, thimble, PVC backlight and connection plate, nuts, bolts, washers, etc. as required complete all as specified and directed by Engineer-in-Charge.
M & L for cleaning of AHU complete with hot water and caustic soda mixture with circulating water pump blower / coil shiner, detection of leakage, repair of damaged cooling coils, tubes with necessary welding/blazing etc complete and refixing the same, testing on load all as specified and directed by the Engr-in-Charge for the following plants:- (i) HQ CICP 3x60 TR (ii) NBC Lab 3x30TR (iii) ADP 3x22.5 TR (iv) CICP 3x15 TR (v) Logistic Section 3x11 TR
Supply and fixing in repairs of 200 mm x 2B dia cast iron pully as per sample including neccessary fixing accesseries complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs of Pre filter 10 micron of size 600 mm x 450 mm x 50 mm in repair made out of GI wire mesh interspaced with two crimp layers and three flat layers flanged deep box type and efficiency 90% as per existing size and pattern for the all three AC Plant air handling unit complete all as specified and directed by Engr-in-Charge. Make :- Athlete or equivalent as approved by Accepting Officer.
Supply and fixing in repairs of Pre filter 10 micron of size 450 mm x 450 mm x 50 mm in repair made out of GI wire mesh interspaced with two crimp layers and three flat layers flanged deep box type and efficiency 90% as per existing size and pattern for the all three AC Plant air handling unit complete all as specified and as directed by Engr-in-Charge. Make: - Athlete or equivalent as approved by Accepting Officer.
Supply and fixing in repairs of terminal base 6 Pole with nuts, bolts and washer for 5HP to 30 HP Motor complete all as specified and as directed by Engr-in-Charge. (Make :- ABB/ Legrand/ L & T/ Seimens/ Kirlaskar.)
Supply and fixing in repairs of over load relay MN-2 type in three frame size from 6- 10 Amp complete all as specified and as directed by Engineer-in-Charge. (Make:- L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER)
Supply and fixing in repairs of tarolene cloth connecting the air outlet and main duct of AHU as per existing size and thickness including provision of chain with zip for taking wet / dry bulb reading complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable defective finned strip heater and supply and fixing strip heater 3 KW 230 volts suitable for AC plant including provision of nuts, bolts & washers etc complete all as specified and as directed (Make:- DasPass or equivalent as approved by Accepting Officer.)
Taking out existing burnt/ unserviceable SMPS board of hot water generator/ compressor for AC Plant and transporting to OEM authorised dealer for necessary repair, replacing the burnt electronic spares to workshop and carrying out the same necessary after repairs and re-assembling the same with the AC plant including testing for staisfactory working complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repairs of side panels with bearing as per existing for fan section made out of MS sheet 16 gauge (1.60mm thick) duly painted with two coats of synthetic enamel grey paint (1st grade quality) over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and as directed by Engineer-in-Charge.(Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
Supply and fixing in repairs of DIDW centrifugal blower with bearing, key incl mounting brackets etc complete of capacity 12000 CFM including taking out of existing unserviceable DIDW centrifugal blower of 12000 CFM with connected accessories complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs of Padestal bearing P-207 heavy duty complete all as specified and as directed by Engineer-in-Charge. Make : NTN/SKF or equivalent make as approved by Accepting Officer.
Supply & fixing in repairs of CI strainer 'Y' type flanged 100mm dia complete all as specified and as directed by Engr-in-Charge. Make:- Audco / Advance / Castle/ Zoloto/ Leader.
Supply and fixing in repairs of fan belt of size B-73 complete all as specified and as directed by Engr-in-Charge. (Make-Fenner/ Dunlop or equivalent make as approved by Accepting Officer.)
Supply & fix in repairs of fan belt of size B-76 complete all as specified and as directed by Engr-in-Charge. (Make-Fenner/ Dunlop or equivalent make as approved by Accepting Officer.)
Supply & fix in repairs of fan belt of size B-82 complete all as specified and as directed by Engr-in-Charge. (Make-Fenner/ Dunlop or equivalent make as approved by Accepting Officer.)
Supply and fixing in repairs of fan belt of size B-92 complete all as specified and as directed by Engr-in-Charge. (Make-Fenner/ Dunlop or equivalent make as approved by Accepting Officer.)
Supply and fixing in repairs of fan belt of size A-34 complete all as specified and as directed by Engr-in-Charge. (Make-Fenner/ Dunlop or equivalent make as approved by Accepting Officer.)
Supply & fix in repairs of fan belt of size A-37 complete all as specified and as directed by Engr-in-Charge. (Make-Fenner/ Dunlop or equivalent make as approved by Accepting Officer.)
Supply & fix in repairs of fan belt of size A-41 complete all as specified and as directed by Engr-in-Charge. (Make-Fenner/ Dunlop or equivalent make as approved by Accepting Officer.)
Supply and fixing in repairs of fan belt of size A-43 complete all as specified and as directed by Engr-in-Charge. (Make-Fenner/ Dunlop or equivalent make as approved by Accepting Officer.)
Supply & fix in repairs of fan belt of size A-50 complete all as specified and as directed by Engr-in-Charge. (Make-Fenner/ Dunlop or equivalent make as approved by Accepting Officer.)
Supply and fixing in repairs of fan belt of size A-58 complete all as specified and as directed by Engr-in-Charge. (Make-Fenner/ Dunlop or equivalent make as approved by Accepting Officer.)
Supply and fixing in repairs of addon block 2 No/ 2NC suitable from MNX 12 to MNX 25 complete all as specified and as directed by Engineer-in-Charge. (Make :- L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER)
Supply and fixing in repairs of start/stop button for starter panels complete all as specified and as directed by Engineer-in-Charge. (Make :- L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER)
Supply & fixing in repairs of MS ERW pipe of size 50 mm bore/ dia and minimum thciness 5mm including all fitting like coupling bends, elbows, tees, thrust block flanges, welding as required including applying one coat of red-oxide zinc chrome primer and two coats of synthetic enamel paint (1st grade quality) complete all as specified and directed by the Engr-In-Charge. (Make:- BST / TATA / JINDAL/ PRAKASH TUBES/ OSWAL.)
Supply & fix in repairs MS ERW pipe of size 125 mm bore/ dia and minimum thciness 6mm including all fitting like coupling bends, elbows, tees, thrust block flanges, welding as required including applying one coat of Red-oxide primer and two coats of synthetic enamel paint (1st grade quality) complete all as specified and directed by the Engr-In-Charge. (Make - BST / TATA / JINDAL/ PRAKASH TUBES/ OSWAL.)
Supply & fix in repairs MS ERW pipe (Header) in any position of size 150 mm bore/ dia and minimum thciness 6mm including all fitting like coupling bends, elbows, tees, thrust block flanges, welding as required including applying one coat of Red-oxide primer and two coats of synthetic enamel paint (1st grade quality) complete all as specified and as directed by the Engr-In-Charge. Make - BST / TATA / JINDAL/ PRAKASH TUBES/ OSWAL.)
Supply & fix in repairs in thermostat suitable for HVAC system fixed AHU room as per existing size of Model TH 1000 PRO complete all as specified and as directed by the Engr-In-Charge. (Make :- Honey well/ Infoss/ Renutrol)
Supply and fixing in repairs of Fan assembly of size 1500 mm sweep complete all as specified and as directed by the Engr-In-Charge.
Supply and fixing in repairs of Fan assembly of size 900 mm sweep complete all as specified and as directed by the Engr-In-Charge.
Supply and fixing in repairs of PVC branch pipe of set of 4 Nos. suitable for 60 TR cap cooling tower complete all as specified and as directed by the Engr-In-Charge.
M&L for painting for Cooling Tower Complete of Cap 3 x 30 TR. Job includes removing the old paint by rubbing and applying one coat of Red-oxide primer and two coats of Synthetic Enamel paint (1st grade quality) including cleaning the tank and preparation of surfaces complete all as specified and as directed by Engineer-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
Supply and fixing in repairs of 3 pole power contactor MNX-12 complete all as specified and as directed by Engineer-in-Charge. (Make :- L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER)
Supply and fixing in repairs of 3 pole power contactor MNX-18 complete all as specified and as directed by Engineer-in-Charge. (Make :- L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER)
Supply and fixing in repairs of 3 pole power contactor MNX-25 complete all as specified and as directed by Engineer-in-Charge. (Make :- L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER)
Supply and fixing in repairs of 3 pole power contactor MNX-32 complete all as specified and as directed by Engineer-in-Charge. (Make :- L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER)
Supply and fixing in repair 3 pole power contactors type MNX 70, AC-3 rating, 2NO + 2 NC complete all as specified and as directed by Engineer-in-Charge. (Make :- Cat No ST19002 of L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Supply and fixing in repairs of Bimetal over load relay type ML-1, 6 to 10 amps complete all as specified and directed by Engr-in-Charge. (Make :- L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Supply and fixing in repairs of over load relay MN-2 type in three frame size from 9- 15 Amp complete all as specified and as directed by Engineer-in-Charge. (Make:- L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER)
Supply and fixing in repairs of over load relay MN-2 type in three frame size from 14- 23 Amp complete all as specified and as directed by Engineer-in-Charge. (Make:- L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER)
Supply and fixing in repairs of MCCB 125 Amps, capacity 25kA, 3 pole, 3 phase, 415 volts with thermal magnetic release complete all as specified and directed by the Engr-in-Charge. (Make: - L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Supply and fixing in repairs of MCCB 250 Amps, capacity 35/36kA, 4 pole, 3 phase, 415 volts with thermal magnetic release complete all as specified and as directed by the Engr-in-Charge. (Make :- L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Supply and fixing in repairs of MCCB 100 Amps, capacity 25kA, 3 pole, 3 phase, 415 volts with thermal magnetic release complete all as specified and directed by the Engr-in-Charge. (Make: - L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Supply and fixing in repairs of MCB four pole 40 Amps, capacity 10kA, C curve complete all as specified and directed by the Engr-in-Charge. (Make:-SIEMENS/ LEGRAND/ L&T/ABB/SCHNEIDER).
Supply and fixing in repairs of Digital type Voltmeter 0 to 600 volts any type shape single phase 50 Hz AC supply complete all as specified and directed by the Engr-in-Charge. (Make:- AE/ MECO/ Rishabh/H Guru)
Supply and fixing in repairs of Digital type Amptmeter 0 to 150 volts any type shape single phase 50 Hz AC supply complete all as specified and directed by the Engr-in-Charge. (Make:- AE/ MECO/ Rishabh/ H Guru)
Supply and fixing in repairs of pumpset jaw coupling including rubber bush including leath work if required complete of capacity 3 HP to 5 HP complete all as specified and directed by Engr-in-Charge.
M & L for complete removal of existing paint from existing pipe of size 63 mm to 125 mm dia and applying two coat of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed by Engineer-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
Supply and fixing in repairs of humidity self priming motor pump set of capacity 0.5HP single phase 240 volts complete all as specified and directed by the Engr-in-Charge. (Make:- Kirloskar/ Crompton Greaves/ Best & Crompton/ Beacon/ Mather & Platt Grandfos/ KSS)
Supply and fixing in repairs of electronic timer type ST 100, capacity 3-30 sec 240 volts complete all as specified and directed by the Engr-in-Charge. (Make: - L&T / SEIMENS / ABB/ LEGRAND/ SCHNEIDER.)
Taking down unserviceable sub main wiring of any type and any size including wooden batten, PVC conduit or casing caping complete all as specified and as directed.
Material and labour for sub main wiring (Concealed) with six runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC conduit of 32mm dia (Heavy duty) with all fittings and accessories surface type complete all as specified and as directed.
Material and labour for sub main wiring (concealed) with six runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC conduit of 32mm dia (Heavy duty) with all fittings and accessories surface type complete all as specified and as directed. {Note for item No. 77 & 78:- (i) Six runs of cable with one run PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Cutting, chasing, pinning of wall shall be measured and paid seperatly. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} (Make of cable:- FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB .) (Make of PVC conduit:- FINOLEX / ANCHOR/ KALINGA/ SUPREME/ POLYCAB.)
Materials and labour for cutting chases, pinning in. making good to facings where required of brick wall and pointing in cement mortar 1:3 to ends and cutting chases for concealed conduit wiring, etc. and making good to surfaces with cutting not exceeding 10 cm girth complete all as specified and as directed.
Taking down old damaged cement plaster of any description including racking out joints hacking for key, scrubbing down with water complete all as specified and as directed.
Demolition of cement concrete in ground floor and paving not exe 15 cm thick (below or above ground level) and including removing of demolished material from site complete all as specified and as directed
Material and labour for rendering 10 mm thick in Cement Mortar (1:4) on fair faces of brick work or concrete surfaces of wall, finished even and smooth with out using extra cement complete all as specified and as directed.
Material and labour for 100mm thick PCC 1:3:6 type C2 (40mm graded stone aggregates) as in floor and finished the surfaces with even and fair complete all as specified and as directed.
Supply and fixing in repairs of new Electronic expansion valve drive for 60 TR AC plant including programming for analog signal positioner for motherboard Model No DCO 3000 HSN code - 853700 of Kirloskar make for satisfactory performance of AC Plant.
Taking out / burnt out Microprocessor board drive, Code No HSN 9954 of Voltas make from 3x30 TR AC Plant and refixing in original position, after necessary repair by replacing the burnt electronic spares from authorised manufacturer workshop, including reprogramming, resolving the problem and testing complete for satisfactory performance of plant complete all as specified and directed by Engr-in-Charge.
Taking out/ burnt drive, PCO 3000AMO motherboard controller, Code No HSN 9954 of Kirloskar make for 60 TR AC Plant and refixing the same after necessary repair by replacing the burnt electronic spares from authorised manufacturer workshop including testing complete for satisfactory performance of plant all as specified and directed by Engr-in-Charge
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron strip 25x4mm as earth lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including taking down old unserviceable one complete all as specified and directed. (Note:- Each protection pipe and earthing lead upto and including 7.5 meter lenght is deemed to be included in the qouted rate of this item.)
M & L for earth continuity conductor or main earthing lead fixed lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc using 25 x 4mm galvanised iron trip including taking down old unserviceable one complete all as specified & directed by Engr-in-Charge.
Materials and labour for preparation of new plastered surfaces of wall internally and applying two coats of white wash complete all as specified and as directed.
Material and labour for cleaning/servicing of cooling tower tank and collecting chamber of AC Plant of capacity 3 x 60TR/ 3 x 30TR/ 2 x 24TR/ 3 x 22.5TR/ 3 x 15TR by brushing and removing the deposit scales/ dludges, etc. complete all as specified & asdirected by Engineer-in-Charge.
Supply and fixing in repairs PVC fins incl eliminator of size 600mm x 300mm x 165mm for cooling tower of AC complete all as specified and directed by the Engr-in-Charge.
Supply and fixing in repairs PVC nozzles of suitable size and specifications (as per sample) complete all as specified and directed by the Engr-in-Charge.
Material and labour for cleaning of condenser of any size of AC Plant of capacity 7.5TR with hot water and caustic soda mixture with circulating water pump blower/ coil shiner, direction of leakage, repair of damaged coil tubes with necessary welding/ brazing etc. complete all as specified & asdirected by Engineer-in-Charge.
Material and labour for cleaning of condenser of any size of AC Plant of capacity 11TR with hot water and caustic soda mixture with circulating water pump blower/ coil shiner, direction of leakage, repair of damaged coil tubes with necessary welding/ brazing etc. complete all as specified & asdirected by Engineer-in-Charge.
M & L for cross arms, bracing, supports and clamp fabricated from structural steel sections, welding, bending cold or hot, drilling, holes for bolts in any shape and size as indicated or directed and inclusive of two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer including taking down old unserviceable one complete all as specified and directed.
Supply and fixing in repairs drier cores filter for chiller unit of central AC Plant of capacity 15 to 30 TR complete all as directed by Engr-in-Charge. (Make:- Denfoss/ Indfoss.)
Supply and fixing of 500 litrs capacity rotational molded polyethylene vertical, cylindrical, triple layered construction ISI marked water tank including cupping, washer, reducer etc. with all other necessary fixing accessories including dismantling of old unserviceable tank complete all as specified & as directed. (MAKE:- POLYCON/ SINTEX/ SHEETAL)
SNOWY ENGINEERING INC
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .