Loading…
Loading…
Tender Value
₹3.9 Cr
EMD Value
₹2.0 L
Closing Date
13 Mar 2026, 5:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
MR Yognarayan sahu(DFLT)
CE(Ambikapur)
CONSTRUCTION OF AUDITORIUM BUILDING AT PATHALGAON DISTT. JASHPUR. (Work code – W31203)
185868
NIT No. 987/TC/2025-26
RESTRICTED TENDER
WORKS
12 days
CE(Ambikapur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
6 documents required · 6 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE(Ambikapur)
PWD Circle, Ambikapur
Division Patthalgaon
120
12
No
0
185868
13 Mar, 2026 5:00:00 PM IST
18 Mar, 2026 10:00:00 AM IST
20 Feb, 2026 5:00:00 PM IST
NIT No. 987/TC/2025-26
CONSTRUCTION OF AUDITORIUM BUILDING AT PATHALGAON DISTT. JASHPUR. (Work code – W31203)
196270.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
39253000.00
2
17 Mar, 2026 5:00:00 PM IST
39253000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
21d 16h 5m
6 documents required · 5 mandatory · 1 optional
₹0
₹2.0 L
20 Feb 2026
20 Feb 2026
18 Mar 2026
20 Feb 2026
13 Mar 2026
20 Feb 2026
17 Mar 2026
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area)
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. 1.1.1 In all types of soils.
Extra for every additional lift of 1.5 m or part thereof. 1.6.1 All types of soils
Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
1.26 Carriage by mechanical transport upto 5 km lead: 1.26.1 Earth
Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Diluting chemical emulsion (Chlorpyriphos/ lindane) in water asper manufacturers ecommendation and injecting for preconstructional curative cum preventive anti- ermitetreatment:(Five year service guarantee bond to be signed bycontractor) 1.24.1 Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm. 1.24.1 Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm.
Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the intervals of 300 mm and plugging with cement mortar 1 :2 (1cement : 2 Coarse sand).
Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the intervals of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
Providing and fixing formwork I/c centering, shuttering, strutting, staging, propping bracing etc. completed including its removal for Foundation, Footing, base of columns and plinth beam in any shape and size upto plint level.
Columns, Pillars, Piers and likes- rectangular or square in shape
Beams, lintels, cantilevers & walls
Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Weather shade, chhajja, Cornices and mouldings
Stair cases of all types excluding spiral and folded plate type, including risers and landings
Edge of slab, breaks in floor and walls upto 200mm.
Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work., (C.N. 3.1.2 ) 1:3:6 (1 cement : 3 coarse sand : 6graded stone aggregate 40mm nominal size).
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and placing in position steel reinforcement for R.C.C. work including cutting. Bending, binding etc. complete as per drawings including cost of binding wire and including all wastage etc. complete (3.14.1) T.M.T. BARS
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including formwork.
Applying a coat or not bitumen 30/40 using @ 1.7 kg./sqm on damp froof copurse after cleaning the surface of brushes and finally with a piece of cloth lighty socked in kerosine oil.
7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)+7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Half brick thick honey comb brick work with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 upto plinth level. Cement Mortar 1:4 (1 cement : 4 coarse sand)
Supplying, filling, spreading & leveling stone boulders/ Gravels/ Coarse sand, in recharge pit, in the required layers and thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (excavation of pit will be paid separately). Stone boulders of size range 5 cm to 20 cm, in recharge pit
Gravels of size range 5 mm to 10 mm, over the existing layer of boulders
Coarse sand of size range 1.5 mm to 2 mm over existing layer of gravel
15mm thick cement plaster on the rough side of single or half brick wall of mix: Outer side of walls.(1:6)
12mm thick cement plaster of inner side of walls.(1:6)
Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand)
Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required width with 40mm long steel nails on vertical and horizontal surface near R.C.C. and brick walls junctions including scaffolding and all lead and lifts etc. complete before plastering upto 10mts in height.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
Making grove in cement plaster while plastering upto10 mm deep and 10 mm wide.
Providing and making 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width:
Providing and making 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width:
Neat Cement punning.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom, kitchen etc., by applying cement slurry mixed with water proofing cement compound consisting of following applications including surface preparation: i) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound@ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing Water proofing treatment over Roof, Wall, Chhajjas, Balcony Diamond shield with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/ Nylon brush. Removing all dust particles and washing with adequate water to clean completely. (ii) Providing and applying 1st coat of diamond shield or equivalent compound (having two component dry powder 80% Chemical 20% (chemical having 30% solid contents) making flexible waterproof and protective modified mortar with minimum thickness 70-80 micron after proper mixing of both the parts of compound along with laying of fiber glass mesh (of weaving size of 10x10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to set in natural air for minimum 2 Hrs. After 1st coat apply 2nd coat with minimum thickness 100 micron of the same compound. Allow the 2 nd coat to set in natural air for minimum 4 Hrs. Total consumption of the diamond shield or equivalent in both coat should be @ 17.90 kg for 10sqm area. (iii) Over the above layers providing and applying 1st coat of sealer compound (Single component High Build elastomeric, flexible, pure acrylic waterproofing membranes having solid content of 65%) minimum 50-60 micron and allow it to set in natural air for minimum 2 Hrs. After 1st coat apply 2nd and final coat 120-140 micron of sealer compound and allow it to set in natural air for minimum 4 Hrs. Consumption of Sealer compound should be @ 5.40 kg per 10 sqm area. The final area appearance of the coating will be milky white. (iv) The treated area should be cure with water for 48 hrs by flooding the surface. All above operations to be done in order.
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 9.11.2 Angle-iron frames Equal angle size 40x40m (4mm thick)
Providing and fixing flush door shutters decorative type, core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges 8.12.2 35 mm. thick (single leaf)
Extra for double leaf shutter instead of single leaf.
Three track three panels sliding window with fly proof S.S. wire mesh (Two Nos. glazed & one no. wire mesh panels) made of (small series) frame 92x44mm & shas 32x60mm both having wall thickness of 1.9+0.2mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm)
Two track two panels sliding window made of (big series) frame 67x50mm & sash 46 x 62 mm both having wall thickness of 2.3+0.2mm and single glazing bead/double glazifng bead of appropriate dimension (Area of window above 1.75 sqm upto 2.50 sqm)
Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screw etc complete
Providing and fixing steel roller for uPVC sliding window with necessary screw etc complete
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): 9.51.2 With float glass panes of 5 mm thickness
9.11 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer.
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat of red oxide zinc chromate primer..
Providing and fixing of floor spring IS: marked (Everite, Door link or any equivalent make) with stainless steel cover plate including cutting and making good the floor etc. complete.
Providing and fixing antique/ SS finished brass butt hinges with antique/ SS polished MS screw complete: 125x85x5.50mm (Heavy Type)
Providing and fixing antique/ SS finished brass sliding door bolt with necessary bolts, nuts and antique/ SS polished MS screw complete: 300x16mm
Providing and fixing antique/ SS finished brass door latch with antique/ SS polished MS screw complete: 250x16x5 mm
Providing and fixing antique/ SS finished brass tower bolts (Barrel type) with antique/ SS polished MS screw complete: 250 x10 mm
Providing and fixing antique/ SS finished brass tower bolts (Barrel type) with antique/ SS polished MS screw complete: 200 x10 mm
Providing and fixing antique/ SS finished brass handles with antique/ SS polished MS screw complete: 125 mm
Providing & fixing 150mm antique/ SS finished brass floor door stopper with rubber cushion and antique/ SS polished MS screw complete to suit the shutter thickness.
Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc complete.
Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete.
Providing and fixing rectified ceramic glazed floor tiles of 1st quality conforming to IS : 15622-2017 of approved make, in all colours, shaded over 20 mm thick bed of Cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3,3 kg per sqm including pointing in white cement mixed with matching pigment complete.
Providing and fixing ceramic glazed wall/dado tiles of first quality conforming to IS : 15622-2017 of approved make, in all colours, shades on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.
Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape / pattern, over 40mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including levelling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sqcm. 12.65.2 Pigment Coloured (rubber mould) precast interlock concrete blocks sqm 632.00
Providing and laying Matt/Glazed finish HOMOGENEOUS ACROSS FULL BODY VITRIFIED floor tiles(heavy duty) with water absorption less than 0.05% and conforming to IS :15622-2017 of 1st quality of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.
Extra for providing and fixing 4mm thick glass strip in joints of Terrazo floor/ cement concrete floor or like. 40 mm wide
12.3 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 12.3.2 50 mm thick
15 MM thick table rubbed polished garnite stone slab flooring laid over 20mm (average ) thick base of cement mortar 1:4 (1 cement , 4 sand ) laid and jointed with grey cement sulry including rubbing and polishing etc. complete ( area of slab should be 0.50 sqm and above ) 12.45.2 Granite stone black
(C.N. 12.46.2)15 mm thick table rubbed polished granite stone slab in riser and treads of steps skirting dado and pillars laid on 12mm (average) thick base of cement mortar 1:3
Extra for nosing in Granite stone for treads.
9.61 Providing and fixing aluminium composite panels in approved panel sizes,thickness and shape on aluminium frame work on face of building. (Frame to be paid separately) 9.61.2 4mm thick
9.60 Designing, providing and fixing aluminium frame work made of special aluminium section on building face with M.S. angle iron brackets fixed on RCC structure with S.S. hold fasteners, including providing and fixing two sided structural adhesive tape of appropriate grade (NORTON or equivalent), on aluminium sections for fixing aluminium/ glass panel, sealing on periphery of frame work, by providing EPDM gasket, silicon weather sealant between aluminium frame and building structure including hire charges of double scaffolding complete. kg 357.00
Providing and fixing factory made UPVC door frame made of UPVC profile section having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge Extruded section Profile size 48x40 mm.
Providing and fixing factory made PVC door shutters of specified Providing and fixing factory made PVC door shutters of specified thickness made of styles and rails of a UPVC hollow section of specified size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. 24 mm thick door shutters with styles and rails of size 59x24 mm
Supply and fixing of precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-incharge) 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge.
9.3 Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer. 9.3.2 Electric resistance or induction butt welded tubes Grade-300 kg 93.50+ 9.4 Extra for curvature in making steel work in tubular structure in built-up sections, trusses and frame work kg 2.30
9.5 Extra for hoisting trusses and placing in position over height above 5m for every 2.5 m height or part thereof.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Ridges plain (500-600mm)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Gutter. (600 mm over all girth).
Applying cement slurry on R.C.C. slab or cement concrete work using 2.75 kg/ sqm for receiving cement concrete floor including roughening cleaning etc complete
(C.N. 12.54) Extra for noising in steps and tread of red or white fine dressed and rubbed sand stone.
Providing and constructing brick masonry chamber for underground pipe and bends with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand) RCC cover of suitable size and 75mm thick with 1:1.5:3 mix (1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) including reinforcement 8mm dia bars at 150mm both ways and MS hooks for lifting, including foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 450x600 mm and 45 cm deep for single pipe line :
Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Providing and applying plaster of paris putty over plastered wall surface including scaffolding complete.
Providing and applying Polymaric cement primer on all surface applied @ 0.80 litrs/10 sqm as per relevant IS code 15489:1974 (product such as Birla white primecoat/activcoat,AsianTrucare,Dulux interior cement primer,Opus Calista/110) with all tool tackles and labour etc.complete for the work. complete.
Providing and applying Premium plastic emulsion paint with roller application minimum three coats applied @ 1.25lit/10sqm up to final finish as per relevant IS Code 15489:2013 Type-1 Class D&C (Glossy & Semi Glossy Finish) of required shade (Product such as Asian,Apcolite Premium,Delux Super Cover,Berger Easy Clean,Nippon Breezee Metex Gold,Opus I-50 / Calista) inclusive of providing abro tape on edges and article and cleaning of door,windows,floor and surface as required with all tools tackles and labour etc. comlete for the work.(with three year Warranty)
Providing and applying on exterior surface with Premium Exterior emulsion paint of required shade to give protective and water proof finish minimum three coats applied @ 1.40 lit/10sqm up to final finish as per relevant IS Code 15489:2013 Type-2 Class D&C (Glossy & Semi Glossy Finish) (Product such as Asian Apex,Dulux Weather Shield Prima E900,Berger Weathercoat Antidust,Nerolac Everlas Excel,Nippon Sumo Etra,Opus True flex) inclusive of providing abro tape on edges and article and cleaning of door,windows,floor and surface as required with all tools tackles and labour etc. comlete for the work.(with three year Warranty)
Providing and applying satin / matt finish Enamel paint minimum two coats in all surface applying @ 0.75 lit/10 sqm upto required finish as per relevant IS Code 2932:2013 of (Product such as Asian satin enamel,Dulux Promise Premium Enamel,Nerolac Synthetic Enamel,Opus Prime Enamel) inclusive of providing abro tap on edges and article and cleaning of door,windows,floor and surface as required with all tools tackles and labour etc. comlete for the work .
Providing and fixing vitreous china water closet squatting pan (Indian type) including cutting and making good the walls and floors wherever required: White Orissa pattern W.C. pan of size 580x440 mm
Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : 18.4.3 White wall hung type
Providing and fixing 15 mm nominal bore uplasticised PVC connection pipe with PTMT nuts and PVC bush of approved quality and colour: 18.10.1 30 CM length
45 CM length
Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: 18.13.2 Flat back type urinal of size 460x380x250mm
Providing and fixing one piece construction white vitreous china squatting plate urinal with an integral rim longitudinal flushing pipe,standard size G.I. flush pipe for back and front flush, C.P. brass coupling complete including cutting and making good the walls and floors etc. wherever required :
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required. 18.17.1 White Size 550x450 mm
White Oval or round size 550x400mm.
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of brackets, cutting and making good the wall wherever required : 18.23.2 Size 600x450x200mm
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 18.25.2 40 mm dia
Providing and fixing PVC waste coupling in wash basin/ sink. 18.26.2 40 mm
Providing and fixing cast iron grating for gully trap. 18.27.2 150x150mm square
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 5mm thick mirror
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 18.76.1 75 mm dia pipe.
110 mm dia pipe.
150 mm dia pipe.
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.1 Tee/ Tee with door/ Bend 45°/ Bend 90° 18.77.1.1 75 mm
Double "Y" with or without door 18.77.2.1 75 mm
Vent covel 18.77.3.1 75 mm
Access door cap 75 mm
"P" trap 110mmx110mm long
Nahani trap 110x75mm
Plain reducing Tee 110x75mm
Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 18.78.1 75 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. INTERNAL WORK - EXPOSED ON WALL 19.4.1 15 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc., 19.5.1 15 mm nominal outer dia .Pipes.
25 mm nominal outer dia .Pipes.
32 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK 19.6.5 40 mm nominal outer dia pipes
50 mm nominal outer dia pipes
Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: 19.13.1 Bib cock (250 grams)
Bib cock (350 grams)
Stop cock (350 grams)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 19.14.1 Bib cock (400 grams)
Long nose bib cock (500 grams)
Long body bib cock (500 grams)
Piller Cock (400 grams)
Two way bib cock (800 grams)
Angle valve for basin mixer and geyser points (450 grams)
Wall mixer with elegant knob (1400 grams)
Hand shower set with flexible extension pipe
Bottle trap set with extension pipes
Toilet paper holder
Soap dish plate
Shower rose (revolving type) (150mm)
Towel rail (600mm long x 20mm dia)
Towel ring (150 mm dia)
Wall mixer (telephonic type) with crutch arrangement for hand shower (1400gms)
Health foscet (hand jet) with flexible connection pipe (for WC)
Providing and fixing stainless steel drain jali of approved make/quality.
Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 19.16.1 25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 19.17.1 15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 19.18.2 32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing and fixing gun metal non- return valve (vertical type) of approved quality (screwed end) : 19.19.2 32 mm nominal bore
40 mm nominal bore
Cutting holes more than 20x20 cm and upto 30x30 cm in walls including making good the same :
Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof.
Making chases upto 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc.
Making hole upto 20x20 cm and embedding pipes upto 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including disposal of malba.
Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarsesand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :
Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
Constructing masonry Chamber 90x90x100 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level. All types of soil 150 mm dia.
Rocky strata including Boulders. 150 mm dia.
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. Rocky strata including Boulders. 150 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, ISI marked G.I. casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part-1&Part-2) 1992 with IVthrevision (Up-to-date amendments), of reputed & approved make, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 150 mm nominal dia
Supplying, assembling, lowering and fixing in vertical position in bore well, ISI marked G.I. casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part-1&Part-2) 1992 with IVthrevision (Up-to-date amendments), of reputed & approved make, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 150 mm dia
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 20.1.1 100 mm diameter
150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 20.2.2 150 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 20.3.2 150x100 mm size P type
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 20.5.1 100 mm dia. R.C.C. pipe
150 mm dia. R.C.C. pipe
Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 20.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :900X450
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: 20.11.1 With 20x20 mm square bar
Providing and fixing filter of minimum 100 litre capacity for roof top rain water harvesting through tube well consisting of two layered HDPE tank with five layers (each layers of minimum 100 mm) consist of coarse sand, 4mm, 6mm, 8mm & 12 mm gravels with stainless steel wire mesh fixed between each layer with suitable length and sufficient numbers of 110 mm dia PVC pipe pieces in the bottom of tank to support the above layer including fixing of inlet and out let P.V.C. pipe of required diameter upto 2 metre length on each side, Cement Concrete plateform of required size complete as directed by Engineer in charge. (excluding cost of tubewell and inlet and outlet pipe beyond 2 metre)
Providing and fixing 80-100 mm dia PVC ball valve for inlet/ outlet of rain water harvesting pipe and filter.
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level. All types of soil 150 mm dia.
Rocky strata including Boulders. 150 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) slotted pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia.
Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 20.32.2 150 mm dia
12.69 38 mm thick parquet (wood blocks) flooring of teak wood laid over25mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm nominal size) to be paid separately coated with thin layer of hot bitumen (blown type) @ 2.45kg/ sqm including fixing blocks after dipping in hot bitumen (blown type) upto half depth planned, leveled, smooth and finished complete. (FOR STAGE )
12.70 Extra for plaining the lower surface of wooden planking sqm
STAGE CURTAIN Manufacture, providing and commissioning of front main curtain and control mechanism as per following materials .1) The main curtain fabric should be more than 300 gsm and more than 25000 to 30000 Rub count 100% polyster in width of 1.40 mts. fabric should stitched with 100 to 120 mm frill all width of fabric to stitch with each other in half width of opening and properly attached with the track assembly.2) Providing and commisioning to track channel of special section 32x22x1.5 mm buffed polised anodized or powder coated track around with heavy duty drive belt geared in 12 to 10mm wide attached with pully drive and master slider and with track is fixed S.S. bracket to hold the track at top of curtain (track length is 7.8mts).3) The above curtain is to controlled by special electronic type motor imported make of Selve (Germany) of equivalent make of torque rated load 2.00 Nm of 80 watt power for carrying the load of fabric up to 80 kg operated with tough drive in radio automotive motor 2 Nos. for operating the curtain two opposite direction. One no. backup motor also to be paired with this system. The motor is to be controlled by R.T.S. Remote control and backups with wireless transmission switchs. (Total operation to be done as per drawing design and direction of Engineer-in-charge)
Providing and installation of acoustical Wall peneling at above 2400 mm height (in auditorium or like) of NRC 0.85 Polyster Fabric (stretchable) 1700mm Wide FR grade shall be strerchable) 1700mm Wide FR grade shall be stretched by using rigid vivyl stretch Tracks half wrap/ Full Wrap 25 mm and midseam track 25mm, polyfibre with requisite accessories and tool. First GL cross channel having thickness of 0.45mm, length upto 3600 mm, knurlled web 40mm, depth 10mm and equal flanges 15mm will be fixed with metal fasteners at 600mm centers, then track tobe installed by using base tape (by removing the protective cover) for a true and continuous secure grip, and heavy duty fasteners at 15mm centers on both sides of the stretch tracks wood wool panel square edge nagnestic bonded wood fiber panels of size 600 x 1200 x 15mm having density 400kg/cum, weight 8- 10kg which is fixed to wall. polyfiber 10mm thick adhered on wood wool panel by using stick 7 adhesive. Fabric of width 1700 mm is then aligned to the stretch tracks by following is stuck on the slign tape (by removing the protective cover) at the same time as being stretched and tucked into the stretch tracks.
UNDERDECK INSULATION: Providing and fixing resin bonded glass wool of 32kg/50mm density just beaneath the roofing sheets at all hight.The fibre glass wool to be covered in polythene tubing of not more than 15 microns from exposed end & cross tied to the purlins of the trusses.The entire glasswool along with polythene tubing to be covered with wire mesh of size 2”x2” from below with proper tieing with trusses including labour cost etc complete.
MAIN HALL FLOORING: Providing & fixing of Loop pile Carpet,100% BCF polypropylene, solution dyed having pile height of 6mm having total density not less than 1100 gsm carpet in hall & balcony areas. Primary & secondary backing of Woven Polypropelene & having permanent static control with proper underlay of hitlon sheets of 10mm & total thickness between16mm rubber solution / SR- 998 pasted on the floor with suitable adhesives including labour etc complete.
AUDUTORIUM CHAIR STRUCTURE - Frame :Back Rest frame of ERW Tube / IS :3074-2005 GRADE 1-16 dia Round Pipe 1.2mm Thickness & Extra Reinforcement 16 dia round pipe 1.2 mm, Cushion Frame (Seat) ERW Tube / IS :3074-2005 GRADE1- 19 dia Round Pipe 1.2mm Thickness. Side Vertical member composition- Wing frame Rectangular Frame, with Side wing frame in plywood with Fabric upholstery. Leg: sq TUBE IS: 4923-1997- 25X25 mm, 1.63 Thickness. SEAT DIAMENSION in mm: WIDTH 480 X DEPTH 435 X THICKNESS 60- 80MM. BACK DIAMENSION in mm: WIDTH 475 X HEIGHT 750 X THICKNESS 25-45MM. SPRINGS - Seat : For Auto Tip-up – Torsion Spring / Spring Steel IS : 4454 1981 GRADE 3 (part i) Tested for 5,00,000 cycles. Push back mechanism – Coil Spring / Spring Steel IS: 4454 1981 GRADE 2 Tested for 1, 00,000 Cycles. FOAM COMPOSITION: Automotive Grade High Resilience-HR Polyurethane foam, Density: 50 + 5 Kg/M3 / JIS K 6401, Constant Compression set: (Max. 13%) JIS K 6401. BACK AND CUSHION HOUSING: PPCP IS: 10915 1994. / Injection Molded/Thermoform Plastic. FINISH OF METAL: All Fasteners are zinc passivated. All exposed & visible parts shall be powder coated. BACKHEIGHT FROM FINISH FLOOR LEVEL: 1030 +/-15mm. Effective seat depth of Seat Cushions Dimensions are in-line with Anthropometric Data’s & ergonomically profiled Contours. TYPE OF BACKREST: PUSHBACK CHAIRS: Slider – 60mm travels with metal ball and roller cage which results in PUSH BACK OF 140 + 10mm. having flexibility to restrict movement of the pushback and slider as per availability of aisle space. ARMREST: Polyurethane waterfall edge design armrest. (Option with Cup holder if required), ARMREST CENTER TO CENTER DISTANCE with options 21/22 Inch (recommended) /23/24 Inch width. FABRIC: heavy duty 100 % polyester dyed yarn with 3mm + .5mm foam backing resultatent. With Content: 100% Polyester, Weight: Abrasion: 80,000, Flammability: BS EN 1021-1 1994 (Cigarette), BS 7176:1995 (Low Hazard), Color Fastness to Light: 5+ [BS 1006 (1990)], Rubbing; Dry: Class 5, et: Class 4.5.
3 SEATER SOFA -WAITING Dimension: 2185 L x 820 x 650 mm ,Arm Height 210mm, Back Height from Armrest: 250mm, Arm Width : 135mm, Length between Legs: 1830mm. Total Width: 810mm, Seating Area Width : 565mm, Seating Area Height: 340mm, Area Length: 470mm, Back Width: 190, Leg Height : 95mm Crome, width between legs: 625mm. Type of Thread Used: Polyster, 6stiches per inch.(PU/PVC/Cotton/ Polyester/ Composite): Thickness : 1mm, Weight 575GSM. FRAME MATERIAL ( PINE WOOD ): Moisture content less then 10%, Anti – Tremite Treatment (Borex Powder Treatment). Thickness of Plywood used(mm) :12mm & 18mm. Standard : IS 303 Commercial Plywood used. SEAT FOAM: Thickness (mm) : 103 mm + 22 mm, Density (Kg/m3): 32 density/28 density soft. Type of foam: Slabstock foam. Back Foam: Mixing of PSF & cut piece of foam. ARMREST FOAM: (DENSITY, TYPE): Thickness (mm) : 24 mm, Density (Kg/m3): 40 density. BELT/ WEBBING MATERIAL:: Width of belt (mm) :68mm - 48mm, Total length of belt used (mm): 68mm :- 3500 mm ; 48mm :- 1850mm.* Fixing of Leg : (Self Tapping Screw / Insert with metric threading) :- Woodscrew provided on frame in addition to M-8 / T-Nut. * Material of leg : (Plastic / Insert Moulding / Wooden/ MS / SS) :- leg 95 mm. (Location: Reception Waiting Area, Ladies Green Room, Gents Green Room.) Refer Drawing No.TD-24.
Providing and fixing false ceiling at all heights with 15 mm thick integral densified Microlook tegular edged light weight calcium silicate false ceiling tile reinforced with fibre and natural filler false ceiling tiles of Size 595x595 MM of approved texture, design and patterns (such as cosmos, spinton,quatra,golb) having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per 15 8225:1987, Light reflectance of 85% (minimum) Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.048 to 0.050 W/m0 KC as per ASTM 518:1991, Weight 1.900 Kg to 2.100 Kg per tile, 15 MM Edge Density having 450 Kg/cum & 10 MM Central portion of tile having 350 Kg/cum, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette grid rotary stiched double webbed white with 6 mm reveal profile (white/black),comprising of main-T runners of size 15x42 mm of length 3000 mm, cross-T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) ie. 40 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size85x25x2mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-inCharge. Ceiling height up 3.5 meter. from adjacent floor level. Extra height to be paid separately. Auditorium
Providing and fixing at all height false ceiling consisting of frame work "W" / "U" / "L" sections made of G.I. sheet with zinc coating of grade 120 consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.55mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed including providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part-I all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting.
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Short Point
Medium Point
Long Point
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 3 X 1.5 sq. mm in 20mm conduit
3 X 2.5 sq. mm in 20mm conduit
6 X 2.5 sq. mm in 25mm conduit
3 X 4 sq. mm in 25mm conduit
3 X 6 sq. mm in 25mm conduit
3 X 10 sq. mm in 25mm conduit
3 X 16 sq. mm in 32mm conduit
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 25 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 1 x 2.5 sq. mm
1 x 4 sq. mm
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. Fan regulator (two module size) electronic stepped type moving all rounds
Ceiling rose 3 pin 5 amp
Batten/ angle holder
Blanking plate
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. Deluxe
Providing and fixing fan hook made of 12mm dia steel bar in existing ceiling slab including cutting of roof, fixing hook above reinforcement on both side, repairing with cement mortar 1:2 (1 cement : 2 sand) etc. as per specification.
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 1200 mm sweep
Supplying, installation, testing and commissioning of following sizes Pedestal fan with telescopic arrangement for height adjustment and standard wiring/connection etc complete as per specification. P.F. should be greater than 0.9 450 mm sweep
Supplying and fixing of wall/ cabin fan including connection etc. as per specification. P.F. should be greater than 0.9 400 mm sweep
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 300 mm sweep
Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 60 cm long
Supplying, installation, testing and commissioning of following LED fitting (luminaries) Panel Light in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 15/16 Watt
Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 15 Watt
Supplying, installation, testing and commissioning of following COB LED Spot Light fitting complete with Electronic Driver Heat sink Capacitor and all other accessories including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 40 watt
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 18/20 watt {4 feet}
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 120 watt
Supplying and fixing metal clad busbar chamber made of 2.0 mm thick CRCA MS powder coated sheet with 4 strip copper busbars of following capacity and length, complete with all accessories, including earthing the body etc. as per specification. 200 amps x 900mm long
Providing and making interconnection in cubical panel between BBC and switchgears with following size FRLS PVC insulated copper conductor wire lead of length upto 50cm including providing copper thimbles on both ends as per specification (To be measured separately for each phase/ neutral). 35 sqmm (125 amps)
Providing and making interconnection in cubical panel between BBC and switchgears with following size copper strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 60x5mm (500 amps)
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. Above 300 mm and upto 450 mm deep
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) copper (electric grade) bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 500 amp (60x5mm)
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 4 pole MCCB, 125A, Adjustable Thermal - Magnetic Release, 50KA
4 pole MCCB, 400A, Adjustable Thermal - Magnetic Release, 50KA
4 pole MCCB, 500A, Adjustable Thermal - Magnetic Release, 50KA
Supplying and fixing on surface/ recess prewired horizontal type following way, 415 volts TP&N, MCB distribution board of sheet steel phosphatized and powder painted complete complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks including interconnections, earthing etc. as per specification. (But without MCB/ RCCB/ Isolator) 8 way (4 + 24), Double door
Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 6 amps to 32 amps
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 63 amps
Providing and fixing metal clad, TP&N 415/500 volts, By Pass Switch Unit with sheet steel enclosure including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. 200 amps
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.
Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) Multi Function meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification.
Supplying, installation, testing and commissioning following rating single phase in single phase out ON-LINE UPS including connection etc but without batteries as per specification. 5 KVA with DC bus voltage 180 V
Supplying, installation, testing and commissioning following rating (Sealed Maintenance Free) lead acid battery including connection as per specification. 65 AH
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as per specification.
Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: With 2 metre long GI Pipes and 25 kg back filling compound.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate having 4 nos holes for fixing etc. complete as per specification.
Making jointing of copper tape (with another copper tape, base of the finial or any other metallic object) by reverting, sweating and soldering/ nut bolting of as per specification.
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as per specification.(For horizontal run)
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as per specification.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, chuck nuts and spring washers etc. complete as per specification.
Providing and laying copper tape 32 mm X 6 mm from earth electrode directly in ground as per specification.
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 90 mm outer dia and 75 mm Inner dia
Supplying and fixing G.I. pipe along with wall or pole/ support with 2 Nos MS clamps for protection of under ground cable in approved manner including bolts and nuts or metal dash fasteners complete as per specification. 50 mm dia
Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 3.5 x 35 sq. mm.
3.5 x 150 sq. mm.
4 x 16 sq. mm.
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. . 3½ X 150 sq. mm (45 mm)
4 X 16 sq. mm (22 mm)
Supplying, fixing and cramping suitable size and all type Copper ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as per specification. 10 sq. mm
Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification and IS: 694 (2010). Note: submersible Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 2.0 HP, single phase
Supplying and fixing following dia HDPE pipe PE-80 Grade (8kg/sqcm) in single length in the suction/ delivery line of water supply pump etc. as per specification. 32 mm outer dia
Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter-connection etc. as per specification. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set
Supplying and fixing M.S. clamp 50 cm long made of 50mmx5mm thick M.S. Flat for holding the pipes and submerable pump set as per specification.
Supplying and fixing 300 mm dia 2 mm thick M.S. sheet cover with 3 cm edge in two past on tube well bore pipe as per specification
Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification and IS: 694 (2010). Note: Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. 3x4.0 sqmm
Supplying and making water proof joint with heat shrinkable joint kit including copper ferrules for following size of 3 core submersible copper conductor cable of 1.1 KV grade as per specification. 3x4.0 sqmm
Supplying and laying of approved make stainless steel wire rope of 6 mm dia for support of submersible pump set complete with tying to pump set and pump holding clamp.
Installation of split type Inverter/Non Inverter Air Conditioner unit, cooling unit on wall inside and condensing unit on out side wall/ ceiling/ floor at desired locations with existing standard length of copper piping with insulation and power cable including providing and fixing necessary good quality powder coated MS frame etc complete as per specification. (Extra length of copper piping and power cable shall be paid extra on linear basis)
Supply and fixing of approved make wall mounting type voltage stabilizer with input volts 160-250, output volts 200-240 volts and double step relay on desired location with necessary fixing material including connection etc complete as per specification. 5 KVA
Supply, connecting and fixing extra length of copper piping for split type air conditioners of following dia and approved quality with insulation sleave etc complete as per specification 5/8 "
Supplying and fixing good quality powder coated MS frame for installation of out door unit of split type Air Conditioner at desired location with atleast 6 nos steel fastners etc complete as per specification
Supplying, connecting and fixing 15mm dia PVC flexible drain pipe (reinforced with nylon threads) in drain outlet of split type air conditioners etc complete as per specification
Supply and filling up required quantity of R-22/R-32/R-410 refrigrent in existing window/ split air conditioners as per manufacturers specification including checking for leakage before and after filling, flushing the line with R-22/R-32/R-410 etc complete as per specification. 2.0 ton split type AC
Supplying of approved make Hiwall split Inverter type Air Conditioner unit with cooling unit (copper coil) and condensing unit (copper coil) including 5 years compressor warranty and standard length of upto 5 metre of copper piping with insulation etc complete as per specification 2.0 Ton split type Inverter AC {5 Star}
Supplying and fixing of approved make Tower Air Conditioner unit with cooling unit and condensing unit with copper coil including standard length of upto 3 metre of copper piping with insulation etc complete as per specification. 4.0 TR
Supplying and fixing wall mounted storage/instantaneous type electric geyser, complete with inner copper container, heating element, thermostat, indicating lamp including inlet / outlet water pipe connection, electric connection testing and commissioning etc. as per specification. 15 Ltr. Capacity storage type geyser 5 star
Supplying , installation , Testing and Commissioning of UHF Wireless Cardioid Condenser handheld microphone system with Frequency Response of 60 Hz to 16 kHz , RF Sensitivity 10dBμV (S/N 60dB @ 20 kHz deviation) or better, Total Harmonic Distortion <1.0% (at 1 kHz, ±20 kHz deviation) or better, Dynamic Range > 108dB or better, on/off switch operating range 60 mtrs or better, RF Power Output: 10 mW or better, maximum Output level XLR / Balanced: +4 dBV & 6.3 mm (¼") / Unbalanced: -2 dBV with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of UHF Wireless Cardioid Condenser lapel microphone system with Frequency Response of 60 Hz to 16 kHz , RF Sensitivity 10dBμV (S/N 60dB @ 20 kHz deviation) or better, Total Harmonic Distortion <1.0% (at 1 kHz, ±20 kHz deviation) or better, Dynamic Range > 108dB or better, on/off switch operating range 60 mtrs or better, RF Power Output: 10 mW or better, maximum Output level XLR / Balanced: +4 dBV & 6.3 mm (¼") / Unbalanced: -2 dBV with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Advanced digital audio processor with open architecture software-configurable functionalityComprehensive library of DSP algorithms optimised for installation applications, 8 Channels of wide band Acoustic Echo Cancellation (AEC) for telephone and video conferencing, Auto mixer functionality for multiple microphone applications, Optional Dante card for IP-based audio networking, PC-based software with intuitive graphical user environment, 10 high-headroom analogue universal mic/line inputs,6 electronically balanced low impedance line level outputs, USB audio connection for integration with computer based audio, ULTRANET digital audio transport output for connection to compatible devices Ethernet port for software configuration via CAT5/5e cable with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Wall Mounted two way full Range speaker with Minimum 2 x 3.5" LF or 1 x 5.25" LF or better with 1" HF with a Frequency Response(-10dB):- 65Hz-20Khz & Long Term Program Power Handling of 120W or more. The Loudspeaker should have a Sensitivity(1W/1m) of atleast 90dB with a Max. Peak SPL of >114dB. Speaker shoudl have 70/100 volt transformer taps with upto 60 watts tapping. The Sound Dispersion should be 90x70 Degrees or better complete with wall mount Bracket of same OEM with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Passive Column Array Loudspeaker with 7 Mid Range Drivers and FAST Dispersion Control for Installation Applications (EN 54 Certified),7 x 3.5" full range drivers with 150 W RMS Power @ 8 Ohms with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Dual Channel Audio Amplifier Professional 1700-Watt (Per Channel 700 to 800 Watts into 4 Ohms OR Per channel 400 to 500 Watts into 8 Ohms OR 1600 to 2000 Watts into 8 Ohms (bridge mode)Stereo with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Mono Connectors Pin with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of RCA Connectors Pin with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of MXLR (Male External Line Return) Connectors Pin with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of FXLR (Female External Line Return) Connectors Pin with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of EP 3.5 MM Connectors Pin with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of MXLR Connector Socket with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of FXLR Connectors Socket with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Patch box with 04 connetors options for mic & stage monitor
Supplying , installation , Testing and Commissioning of 2.5Sq.mm Speaker cable Cross sec Area 1.5 sqmm, No of Strands 75 , Size of Strands 34 , Cond.Type ATC Speaker Cable - Copper 2Core, Twisted, Tin Coated, Shielded 2.5SQMM (70/.2) ATC 2/C SPEAKER CABLE 14AWG with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Heavy Microphone Cable AWG NOM Insulation Dia. Shield NOM NOM Conductor Center Inches mm Construction Jacket Dia. Capacitance Resistance Canductor (Min.) Inches mm (Pf / mtr.) Ohm / km (Max.) 24 AWG 0.053 1.35 80% 0.232 5.9 68(Cond. To Cond.) 91.1 with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Power Management (Constant Voltage / Frequency Stabliser): Power Conditioner, with a built in 3 Way Sequencer that provides sequenced switching with a fixed interval, turning them on & off ina preset sequence. Adjustable Protection Levels : Over voltage 245-275 VAC Under voltage 170-220 VAC with Disable %-Over Frequency 50.5-55.0 hz with Disable Under Frequency 45.5-49.5 hz with Disable with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of 17U Equipment Rack, with Metal Side Panel, Back Door, Front Glass Door, Floor Wheel, 15u PDU Unit, Cooling FAN, Cable Manager, Counter Shelf with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning Cardioid Condenser Gooseneck Microphone with goosenck length of 415mm or more. Flexible gooseneck head for accurate positioning. Shock Mount to be inlcuded with Microphone from same OEM with Frequency Response 70 Hz - 16,000 Hz; It shall be capable of handling sound input levels up to 134 dB with a dynamic range of 106 dB. Nominal open-circuit output voltage shall be 12.0 mV at 1 V, 1 Pascal or better, Signal-to-noise ratio of 66dB,1kHz at 1Pa or better. Support 11V to 52V phantom power for operation. Impedance 100 ohms or better complete with Foam Windscreen with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning Active Speaker 1100 Watt 2 Way 15" Full Range Powered Loudspeaker with DSP Technology Components 1 x 15" LF driver 1 x 1" HF driver Connectors Mic/Line input: combo jack/female XLR wired pin 2 hot Mix out: male XLR wired pin 2 hot Controls Level, Line/Mic, Low Cut, Speech/Music, Bass and Treble, Front LED, Mains on/off requency Range 45 Hz–18 kHz ±3 dB 40 Hz–20 kHz –10 dB Dispersion @-6 dB pts 90° H x 60° V Max SPL (peak) 130 dB Equalisation Bass: ±6 dB @ 80 Hz Treble: ±6 dB @ 12 kHz Max Output Power LF: 1000 W HF: 100 W with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning Active Speaker 2200 Watt 18" Powered Subwoofer Components 1 x 18" LF driver Connectors Input: 2 x female XLR wired pin 2 hot Thru: 2 x male XLR wired pin 2 hot Frequency Range 40 Hz–100 Hz ±3 dB 30 Hz–150 Hz -10 dB Dispersion @-6 dB pts N/A Max SPL (peak) 134 dB (half space) Boost Frequency +6 dB @ 40 Hz–90 Hz, Q=1 Max Output Power 2200 W Input Sensitivity +4 dBu @ centre position for full rated power Input Impedance 10 kO unblanced, 20 kO balanced with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning 24‑channel Compact Mixing System, 24 input channels (16 Mic/Line + 4 Mic/Stereo-Line) 2 High-Quality editable effects, MIC input to Master A L/R outputs, +16 dBu, typical < 0.01% Frequency Response, -3 dB, ref. 1 kHz, any input to any Mixer output 15 Hz to 20 kHz, Equivalent Input Noise, MIC input, A-weighted, 150 ohms -130 dBu with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning Wall Hanging Arrangement for Speaker Metal Wall Bracket with necessary accessories to mount the speakers on wall with all necessery terminals and Connectors.
Earth work in soft rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling with excavated soil in trench / pit to ground level complete as per specification
UOM Name
Percentage
Per mile
Per Diem Rate
MAN DAYS
Siemens Per meter
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.07 MB
3662590503382863201_153213_1258250143523725404_129113_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
6217050387897487580_185868_annexure E.docx
NIT • 0.02 MB
8263313268310344416_185868_Form A.doc
NIT
8594462528882858954_185868_NIT.doc
NIT
13185953553565720_185868_Notice.doc
NIT
8022211097529131400_185868_BOQ.xlsx
BOQ • 0.13 MB
9189200445087257390_185868_List of Approved Materials.xlsx
BOQ
Download all tender documents and submit your bid