GEMC-511687736099107
Awarded to Hamara Enterprises
₹17.5 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Color Doppler ultrasound | BPL -E CUBE 7 | - | 1 NOS | ₹17.5 L | 1,749,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹17.5 LQualified Make: BPL
Model: BPL -E CUBE 7 10 2 223 PLOT NO 17 RL COLONY VAJPAYEE ROAD RAMPALLY MEDCHAL MALKAJGIRI TELANGANA 501301 UDYAM TS 20 0056639 | MEDCHAL MALKAJGIRI | TELANGANA | 501301 | Make: BPL
Model: BPL -E CUBE 7 | ₹17.5 L | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
23 Jul 2018, 2:00 pmClosed
COMPUTED RADIOGRAPHY SYSTEM Experience with Gov. Required 2 Year (s) COMPUTED RADIOGRAPHY SYSTEM ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values TYPE Type of computed radiography (CR) System Single Loading computed radiography System (SLCRS) Single Loading computed radiography System (SLCRS)
Multi Loading Computed Radiography System (MLCRS) COMPATIBILITY CR System compatible with standard X-ray Machine consisting of Digitizer Patient Identification System
Preview And Processing Server with Workstation Yes - C R System to be supplied with compatible Cassettes & Imaging Plates for Recording Yes - ACCESSORIES FOR MULTI LOADING CR SYSTEM Imaging plate and Cassette (dimensions in inch x inch) set offered with Multi loading computed radiography system 14x17
14x14
10x12
8x10sizes-Img.Plate & Castt.-3 units each
8x1 0
10x12sizes- Img.Plate& Mammo.Castt-2 units each 14x17
10x12sizes- Img.Plate& Mammo.Castt-2 units each
14x17
1/8 10x12
8x10sizes- Img.Plate & Castt.-6 units each
8x10
10x12 sizes-Img.Plate& Mammo.Castt-3 units each
8x10sizes- Img.Plate & Castt.-9 units each
10x12 sizes-Img.Plate& Mammo.Castt-4 units each
NA for Single loading CR System ACCESSORIES FOR SINGLEI LOADING CR SYSTEM Imaging plate and Cassette (dimensions in inch x inch) set offered with Single loading computed radiography system 14x17
sizes- Img.Plate & Castt.-3 units each 14x17
sizes- Img.Plate & Castt.-3 units each
sizes-Img.Plate & Castt.-6 units each
sizes-Img.Plate & Castt.- 9 units each
NA for Multi Loading CR System IMAGE READER For the largest Imaging plate/Cassette size
the Images Reading (CR Reader)/Digitizer is able to process >= 30 Imaging Plates/hour (for offered single loading computed radiography system) - CR Reader/Digitizer should have Pre-set Anatomical Processing facility
acquisition and Image transfer at a resolution 12 Bits/pixel Yes - CR Reader/Digitizer should have Status Display facility preferably on a LCD Display Indicating Error Status etc Yes - CR Reader/Digitizer should have Scanning Resolution of (5-10 Pixels/mm Or More) Yes - CR Reader/Digitizer should have ability to route Images To Multiple Destinations Like Work Stations
Dry Camera etc Yes - If multi loading computerised system
CR Reader/Digitizer to be supplied along with NA for SLCRS - 2/8 an Input and Output Cassette Buffer/stacker for >=4 Cassettes each CR Reader/Digitizer should have a scanning resolution >= 20 Pixel/mm for General Cassette Reading and for Mammography And Extremities
multi loading CR system - CENTRALISED PATIENT STUDY MANAGEMENT (CPSM) UNIT Processing Server And Workstation With 21 Inch LCD Monitor for Centralized Patient Study Management (CPSM) unit Yes - CPSM unit should have features: (i) Work Station must be able to receive CR Images From Digitizer (ii) DICOM Ready For Sent
Receive And Print Facility Protocol Yes - CPSM unit should have features: (iii) Possible To Multi-formatting The Images On Film For Printing (iv) 21 Inch LCD Monitor For Patient Study Management (v) Possible To Write Images On A CD/DVD Yes - CPSM unit should have features: (vi) Ready To Accept Images From Work List And Patient Data And Images Another RIS/HIS (DICOM PROTOCOL) (vii) Black Border Facility Yes - CPSM unit should have features: (viii) Software For Printing And To Create Various Film Layouts And Multiple Formats On Single Film For Optimum Utilization Of Film And Presentability Yes - CPSM unit should have The Capability To Customise User Defined No of Formats Yes - 3/8 And Layouts On The Single Film CPSM unit should have capability of Printing the Zoomed Image along with The Overview of the Main Image on same film Yes - CPSM unit should have capability of Printing Multiple Patient Images on one Film And Multiple Images of same Patient on One Film Yes - CPSM unit should have features: Image Gray Scale Reversal
Image Flipping And Rotating
Image Zooming Yes - CPSM unit should have features: Edge Enhancement
Latitude Reduction
Image Noise Reduction
Gray Scale Saturation Feedback Yes - CPSM unit should have provision For Adding Markers Yes - Patient Identification Preview (i) Separate Or Inbuilt Patient Identification System (ii) Cassette Identification And Demographics Should Be Standard (iii) It Should Be Possible To Identify The Multi X-ray Units Separately Yes - DRY IMAGER Dry Imager (For Film Printing) to be supplied with offered Single Multi loading CR System
should be with a Spatial Resolution >= 500 PPI/DPI
Contrast Resolution of >= 12 Bits/Pixel
Preferably with Standard Film Sorter at the Output for sorting the Films Bases On Modality Connected Access Time For First Yes - 4/8 Film Should Be 90 Seconds Or Less The Dry Imager should be DICOM Compatible for Receive Sent And Print Facility and it should allow (for multi loading CR System) at least Allow Three Sizes From the Five Sizes To Be Loaded at Any Time Printer Status Should Be Displayed For Any Error Status Etc Dry Imager should be with Preferably with Standard Film Sorter at the Output for sorting the Films Bases On Modality Connected Access Time For First Film Should Be <= 90 Seconds Yes - Dry Imager should be DICOM Compatible for Receive Sent And Print Facility
Printer status should Be Displayed For Any Error Status Etc Yes - Dry Imager should allow (for MLCRS) >= 3 sizes from the 5 Sizes to be loaded at any time No
SLCRS offered. - Number of online sizes (at least) out of 8 x10
10x 12
14x 14
14x17 sizes
available in the Dry Imager 2 online sizes for offered single loading computed radiography system - For the largest size
Dry Imager (For Film Printing) have a normal through put (Films Per Hour) of at least of >= 30 for offered single loading computedradiography system - CONNECTIVITY & SCALABILITY Interconnectivity Between Various CR Modules Should Be Ethernet Based Yes - Scalability : The CR System Should Have Scope Of Adding Advanced Quality Software For Image Yes - 5/8 Processor
Workstations Connectivity To Any DICOM Archive Or Image Management Systems (PACS) ADVANCED QC VIEWER Advanced QC Viewer shall be with 19 Inch High Resolution Medical Grade Monitor for reviewing of the Images No - Advanced QC Viewer should be a separate Module For being able to be kept away From The Digitizer/CR Reader In the room of choice NA-Advance QC Viewer Not offered with CR System - Advanced QC Viewer should have features; (i) Window leveling
Annotation
Printing
Rotating
Flipping
Panning
Zooming All Image Post Processing NA-Advance QC Viewer Not offered with CR System - Advanced QC Viewer should have features; (ii) Should Have Hospital Information System (HIS) Connectivity (iii) There Should Be Provision For Adding Marker On The Film NA-Advance QC Viewer Not offered with CR System - Advanced QC Viewer should have features; (iv) It should be possible To Write Images On A CD/DVD: NA-Advance QC Viewer Not offered with CR System - POWER BACK UP The Entire Equipment Should Be Supplied With UPS of The Required Rating And Sufficient To Provide At Least 30 Minutes Back Up For The Whole System Yes - CERTIFICATION Should be US FDA/CE (European)/BIS approved product OEM should have ISO certificate for quality standard Yes
USFDA approved - 6/8 Copy of US FDA/CE (European)/BIS approval to be kept in Seller online locker and also made available to buyer on demand Please specify link to document in Seller Locker 510(K) k132687 - Availability Of Type Test Reports(TTRs) of The Product From Central Govt/NABL/ILAC Accredited Lab Showing Compliance To The Specification No - Test Report No 11000788 - Test Report Date 26.12.2017 - Name Of The Labs ALPINION MEDICAL SYSTEM Co. Ltd. - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rajendra Kumar Chopra 110095
Guru Teg Bahadur Hospital
Dilshad Garden 1 35
358593
GEM/2018/B/50801
GeM Contract
COMPUTED RADIOGRAPHY SYSTEM
GeM Contract
35 days
Delhi; Shahdara
PRODUCT
Awarded to Hamara Enterprises
₹17.5 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Color Doppler ultrasound | BPL -E CUBE 7 | - | 1 NOS | ₹17.5 L | 1,749,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| COMPUTED RADIOGRAPHY SYSTEM Experience with Gov. Required 2 Year (s) COMPUTED RADIOGRAPHY SYSTEM ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values TYPE Type of computed radiography (CR) System Single Loading computed radiography System (SLCRS) Single Loading computed radiography System (SLCRS) | - | - | - |
| Multi Loading Computed Radiography System (MLCRS) COMPATIBILITY CR System compatible with standard X-ray Machine consisting of Digitizer Patient Identification System | - | - | - |
| Preview And Processing Server with Workstation Yes - C R System to be supplied with compatible Cassettes & Imaging Plates for Recording Yes - ACCESSORIES FOR MULTI LOADING CR SYSTEM Imaging plate and Cassette (dimensions in inch x inch) set offered with Multi loading computed radiography system 14x17 | - | - | - |
| 14x14 | - | - | - |
| 10x12 | - | - | - |
| 8x10sizes-Img.Plate & Castt.-3 units each | - | - | - |
| 8x1 0 | - | - | - |
| 10x12sizes- Img.Plate& Mammo.Castt-2 units each 14x17 | - | - | - |
| 10x12sizes- Img.Plate& Mammo.Castt-2 units each | - | - | - |
| 14x17 | - | - | - |
| 1/8 10x12 | - | - | - |
| 8x10sizes- Img.Plate & Castt.-6 units each | - | - | - |
| 8x10 | - | - | - |
| 10x12 sizes-Img.Plate& Mammo.Castt-3 units each | - | - | - |
| 8x10sizes- Img.Plate & Castt.-9 units each | - | - | - |
| 10x12 sizes-Img.Plate& Mammo.Castt-4 units each | - | - | - |
| NA for Single loading CR System ACCESSORIES FOR SINGLEI LOADING CR SYSTEM Imaging plate and Cassette (dimensions in inch x inch) set offered with Single loading computed radiography system 14x17 | - | - | - |
| sizes- Img.Plate & Castt.-3 units each 14x17 | - | - | - |
| sizes- Img.Plate & Castt.-3 units each | - | - | - |
| sizes-Img.Plate & Castt.-6 units each | - | - | - |
| sizes-Img.Plate & Castt.- 9 units each | - | - | - |
| NA for Multi Loading CR System IMAGE READER For the largest Imaging plate/Cassette size | - | - | - |
| the Images Reading (CR Reader)/Digitizer is able to process >= 30 Imaging Plates/hour (for offered single loading computed radiography system) - CR Reader/Digitizer should have Pre-set Anatomical Processing facility | - | - | - |
| acquisition and Image transfer at a resolution 12 Bits/pixel Yes - CR Reader/Digitizer should have Status Display facility preferably on a LCD Display Indicating Error Status etc Yes - CR Reader/Digitizer should have Scanning Resolution of (5-10 Pixels/mm Or More) Yes - CR Reader/Digitizer should have ability to route Images To Multiple Destinations Like Work Stations | - | - | - |
| Dry Camera etc Yes - If multi loading computerised system | - | - | - |
| CR Reader/Digitizer to be supplied along with NA for SLCRS - 2/8 an Input and Output Cassette Buffer/stacker for >=4 Cassettes each CR Reader/Digitizer should have a scanning resolution >= 20 Pixel/mm for General Cassette Reading and for Mammography And Extremities | - | - | - |
| multi loading CR system - CENTRALISED PATIENT STUDY MANAGEMENT (CPSM) UNIT Processing Server And Workstation With 21 Inch LCD Monitor for Centralized Patient Study Management (CPSM) unit Yes - CPSM unit should have features: (i) Work Station must be able to receive CR Images From Digitizer (ii) DICOM Ready For Sent | - | - | - |
| Receive And Print Facility Protocol Yes - CPSM unit should have features: (iii) Possible To Multi-formatting The Images On Film For Printing (iv) 21 Inch LCD Monitor For Patient Study Management (v) Possible To Write Images On A CD/DVD Yes - CPSM unit should have features: (vi) Ready To Accept Images From Work List And Patient Data And Images Another RIS/HIS (DICOM PROTOCOL) (vii) Black Border Facility Yes - CPSM unit should have features: (viii) Software For Printing And To Create Various Film Layouts And Multiple Formats On Single Film For Optimum Utilization Of Film And Presentability Yes - CPSM unit should have The Capability To Customise User Defined No of Formats Yes - 3/8 And Layouts On The Single Film CPSM unit should have capability of Printing the Zoomed Image along with The Overview of the Main Image on same film Yes - CPSM unit should have capability of Printing Multiple Patient Images on one Film And Multiple Images of same Patient on One Film Yes - CPSM unit should have features: Image Gray Scale Reversal | - | - | - |
| Image Flipping And Rotating | - | - | - |
| Image Zooming Yes - CPSM unit should have features: Edge Enhancement | - | - | - |
| Latitude Reduction | - | - | - |
| Image Noise Reduction | - | - | - |
| Gray Scale Saturation Feedback Yes - CPSM unit should have provision For Adding Markers Yes - Patient Identification Preview (i) Separate Or Inbuilt Patient Identification System (ii) Cassette Identification And Demographics Should Be Standard (iii) It Should Be Possible To Identify The Multi X-ray Units Separately Yes - DRY IMAGER Dry Imager (For Film Printing) to be supplied with offered Single Multi loading CR System | - | - | - |
| should be with a Spatial Resolution >= 500 PPI/DPI | - | - | - |
| Contrast Resolution of >= 12 Bits/Pixel | - | - | - |
| Preferably with Standard Film Sorter at the Output for sorting the Films Bases On Modality Connected Access Time For First Yes - 4/8 Film Should Be 90 Seconds Or Less The Dry Imager should be DICOM Compatible for Receive Sent And Print Facility and it should allow (for multi loading CR System) at least Allow Three Sizes From the Five Sizes To Be Loaded at Any Time Printer Status Should Be Displayed For Any Error Status Etc Dry Imager should be with Preferably with Standard Film Sorter at the Output for sorting the Films Bases On Modality Connected Access Time For First Film Should Be <= 90 Seconds Yes - Dry Imager should be DICOM Compatible for Receive Sent And Print Facility | - | - | - |
| Printer status should Be Displayed For Any Error Status Etc Yes - Dry Imager should allow (for MLCRS) >= 3 sizes from the 5 Sizes to be loaded at any time No | - | - | - |
| SLCRS offered. - Number of online sizes (at least) out of 8 x10 | - | - | - |
| 10x 12 | - | - | - |
| 14x 14 | - | - | - |
| 14x17 sizes | - | - | - |
| available in the Dry Imager 2 online sizes for offered single loading computed radiography system - For the largest size | - | - | - |
| Dry Imager (For Film Printing) have a normal through put (Films Per Hour) of at least of >= 30 for offered single loading computedradiography system - CONNECTIVITY & SCALABILITY Interconnectivity Between Various CR Modules Should Be Ethernet Based Yes - Scalability : The CR System Should Have Scope Of Adding Advanced Quality Software For Image Yes - 5/8 Processor | - | - | - |
| Workstations Connectivity To Any DICOM Archive Or Image Management Systems (PACS) ADVANCED QC VIEWER Advanced QC Viewer shall be with 19 Inch High Resolution Medical Grade Monitor for reviewing of the Images No - Advanced QC Viewer should be a separate Module For being able to be kept away From The Digitizer/CR Reader In the room of choice NA-Advance QC Viewer Not offered with CR System - Advanced QC Viewer should have features; (i) Window leveling | - | - | - |
| Annotation | - | - | - |
| Printing | - | - | - |
| Rotating | - | - | - |
| Flipping | - | - | - |
| Panning | - | - | - |
| Zooming All Image Post Processing NA-Advance QC Viewer Not offered with CR System - Advanced QC Viewer should have features; (ii) Should Have Hospital Information System (HIS) Connectivity (iii) There Should Be Provision For Adding Marker On The Film NA-Advance QC Viewer Not offered with CR System - Advanced QC Viewer should have features; (iv) It should be possible To Write Images On A CD/DVD: NA-Advance QC Viewer Not offered with CR System - POWER BACK UP The Entire Equipment Should Be Supplied With UPS of The Required Rating And Sufficient To Provide At Least 30 Minutes Back Up For The Whole System Yes - CERTIFICATION Should be US FDA/CE (European)/BIS approved product OEM should have ISO certificate for quality standard Yes | - | - | - |
| USFDA approved - 6/8 Copy of US FDA/CE (European)/BIS approval to be kept in Seller online locker and also made available to buyer on demand Please specify link to document in Seller Locker 510(K) k132687 - Availability Of Type Test Reports(TTRs) of The Product From Central Govt/NABL/ILAC Accredited Lab Showing Compliance To The Specification No - Test Report No 11000788 - Test Report Date 26.12.2017 - Name Of The Labs ALPINION MEDICAL SYSTEM Co. Ltd. - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rajendra Kumar Chopra 110095 | - | - | - |
| Guru Teg Bahadur Hospital | - | - | - |
| Dilshad Garden 1 35 | - | - | - |
Exempted
6 Oct 2018
20 Jul 2018
contract_GEMC-511687736099107.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_358593.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .