Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.6 CrRejected-Finance | ₹2.6 Cr | 1 | Rejected-Finance Tender Cancelled |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Disqualified as per Technical bid evaluation report |
Tender Value
₹3.2 Cr
EMD Value
₹2.4 L
Closing Date
28 Jun 2021, 3:00 pmClosed
Chief Engineer
Chief Engineer MRP Water Resources Department Raipur
Lighting Arrangement Of Dam Top, Right and Left Guide Bund, Garden, Gallery, Supply Installation Testing and Commissioning Of LED Street Light Fixture, Pole, Cable, AB Cable, Sky Lift(Sky Man) / Light Elevator , 1 No, 250 KVA 11/0.43KV New SS etc
2021_WRCWB_624787_1
19/SAC/20-21/EM/Rudri/DripII
Open Tender
Electrical Works
335 days
RUDRI
Please refer tender document
2 documents required · 2 mandatory
₹2,000
Executive Engineer,EM H.E.M.M. Division Rudri
₹2.4 L
Raipur
19 May 2022
31 Mar 2021
29 Jun 2021
31 Mar 2021
28 Jun 2021
31 Mar 2021
31 Mar 2021 - 13 Apr 2021
22 May 2021
Amount
Supply & Laying of approved make10 sqmm. 4 core grade PVC insulated heavy duty copper armoured cable 10 sqmm Grade 4 core IS : 7098 (part-I) 1988-650 to 1100 volts complete with all necessary material clamp, nut bolt, washer, etc. as per specification Complete test & trail lead & lift, transportation &lobour charges. as directed by Engineer in charge.
Supply & Laying of approved make 06 sqmm. 4core grade PVC insulated heavy duty copper armoured cable 06 sqmm Grade 4 core IS : 7098 (part-I) 1988-650 to 1100 volts complete with all necessary material clamp, nut bolt, washer, etc. as per specification Complete test & trail lead & lift, transportation &lobour charges as directed by Engineer in charge.
Supplying and laying of approved make 4 core x 1.5sqmm sizes one number PVC insulate, PVC sheathed, steel armoured, copper conductor control cable of 1.1 kv grade direct in ground including excavation ,sand cushioning, protective covering an refilling the trench etc. as required. as per specification IS : 7098 (Part-1) 1988-650 complete with all necessary material test lead & lift, transportation & labour charges & trail at RSP Site .
Fixing of 4 x 1.5 sqmm (1028m) One No. PVC insulated steel armoured cable in existing tubular pole for dam top lighting at RSP. complete with Drilling/ cutting, welding, Grinding with complete pole painting (Aluminium colour ) as per specification latest ISO mark complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges.
Supplying and fixing of approved make and accepted standard sheet enclosures (dust protected) for TP & N distribution board, as per IS: including bus bar, neutral link, din bar suitable for incorporating M.C.B. surface/flush mounting type steel complete with fixing in sheet steel mounting type as per accepted practice dully holed in end plate completely flushed in wall, cable connection etc. Complete as per specification & ISI mark with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges.
Providing and laying of 13sqm or 9 SWG GI/steel Earth continuity conductor including fixing with copper clamps and all necessary materials as per specification & ISI make along the run of cable complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges.
Supply fabrication & fixing of 25 x 25 x 5mm size angle iron for laying & clamping of cable in parafit wall in every 400mm distance complete with cutting, making cable clamp & fixing in position and applying a priming coat of red oxide zinc chromate primer. complete as per specification with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges.
Supplying, installation, testing and commissioning of approved make 230/250 volts LED street light fitting as per IS: 10322 (Part-1) Sec 1-2012 with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 5 KV surge protection on pole bracket complete as required and furnishing 2 Yrs Guarantee certificate from manufacturer complete as per specification & ISI make with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges. a. 60 Watt
b. 90Watt
Supplying & fixing of approved make 63 Amp. TPN iron clad/metal clad triple pole and neutral (four pole) switch fuse for main switch as per IS : 3854-1997 with fixing on 25 x 25 x 5 mm iron clamp including supply & fixing of clamp as required & dully embedded in masonry cable connection and other required material complete as per specification & ISI make with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges.
Dismantling of existing underground up to 35sqmm power cable from surface including recoiling of dismantled cable and shifting to Department store. Complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges.
Dismantling the all size of outdoor lighting luminaries from steel poles with accessories including shifting of dismantled material department store. Complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges.
Supplying & fixing of copper lugs as specification and ISI certificate make. Complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges. A. Copper lugs for 06 sq.mm cable
B. Copper lugs for 10 sq.mm cable
C. Copper lugs for 50 sq.mm cable
Providing and fixing earthing arrangement with 600mm x600mm x3.15 mm copper plate electrode. Including packing of charcoal powder and salt as per specification, watering pipe 19mm dia G.I. connection etc. complete with refilling the pit as required, but excluding the excavation of earth pit. Complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges
Excavation in soft rock including 50 m lead and 1.5 m lift with dressing for earth pit size [1.5m (L) x 1.5(W) x 1.5(D) ] & pole pit size [0.75(L) x 0.75 (W) x 1.5(D)] Complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges
Providing and fixing down conductor with G.I. strip size 25 x 3mm ISI mark as per specification & IS -DNEN 50164-2 complete including connections to earth electrode. Complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges
Fixing of fabricated angle iron of parapet wall for cable laying & distribution box complete with drilling, filling of mix cement, sand and metal as per specification including all lead lift transportation &labour charges as directed by Engineer in charge.
Supplying and erection of bow stay set complete (galvanized) 19/20 mm dia x 1.8 metre long stay rod, anchor plate of size 30cmx30cmx6.4 mm, thimble stay clamps, blow tightener, strain insulator and specified 7/4.00mm dia G.I. stay wire etc. in cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and also with 0.6 m long brace of size 50mm x 50mm x 6mm angle iron with 50 mm dia pulley fixed at one of the brace as required. as per specification latest ISO mark Complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges
Designing and providing suitable and approved size RCC foundation in cement concert 1:2:4(1 cement, 2coarse sand, 4 graded stone aggregate 20 mm nominal size ) for 3 meter to 12 meter high GI Octagonal pole, including steel reinforcement (minimum 90 kg per cum.), from work, embedding 2 nos. 50 mm dia PVC pipe for cable entry in each foundation excavation disposal of surplus soil and curing etc. as per specification Complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges
Providing and making suitable CC pole collar (muffing) in Cement Concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) of size 0.4 m dia and 0.4 m height from existing CC foundation. as per specification Complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges.
Supply, Erection ,Testing & commissioning of approved make10m high dia175 mm at bottom and 70 mm at top base plate size 275 mm x275 mm x 16 mm, foundation bolts 750 mm long hot dipped galvanized (single dipped 65 micron) octagonal pole with pole brackets single over hang 1.5mtr. pole made of 3 mm thick steel sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected with following minimum specification including 4 mm thick anchor plate ,4 nos 24 mm dia foundation bolts of EN8 grade (designed for wind speed up to 150 km/hr. ) in existing cement concrete foundation having grouted bolt with approved make & nut align in to vertical position as per specification & IS: 875, BS 5649 (Part -VI) 1982 mark. Complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges.
Supplying and fixing of approved make water tight terminal box made of 1.6mm thick M.S. sheet with detachable gland plate in bottom, hinged front open able cover, rubber gasket, having 1 Nos 4way connector and 1 No SPMCB inside the box for cable connection, fixed to pole with 2 Nos clamp made from 40x3mm M.S. flat with 2 No nut bolt dully painted with 2 coat of red oxide paint and 2 coat aluminium paint complete as required. as per specification IS : 8309-1993 with approved make & ISI mark. Complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges. a. 20 x 15 x 15 cms.
b. 30 x 20 x 15 cms.
Supplying Installation testing and Commissioning of approved make 20 Watt., 230/250 volts LED Post Top Lantern fitting with LED Bulb,perplex cover, electronic driver, heat sink, capacitor and other accessories on existing pole bracket as reputed & approved make specification & IS: 10322 (Part - V) Sec - 1 - 2012 certification mark complete as required and furnishing 2 Yrs Guarantee certificate from manufacturer all lead lift transportation &labour charges at RSP site as directed by Engineer in charges.
Supplying and fixing of 32 mm sizes PVC conduit along with accessories in surface complete as required as per specification & ISI mark. Complete with all necessary arrangement tool tackles all lead lift transportation &labour charges at RSP site as directed by Engineer in charges.
Providing and laying Cast-in-situ cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm including mixing with mechanical mixer, compacting with vibrator, finishing and currying etc. complete but excluding form work & curing as per specification all lead lift transportation &labour charges at RSP site as directed by Engineer in charges
Supply erection testing and commissioning of approved make Round White Mild Steel (Hot dipped Galvanized) Decorative Garden light pole 4m Height ,pole dia 100mm to 80mm with thickness not less than 4.80mm (Bottam) to 4mm (Top) as per IS:1161 & Latest complete with Base plate suitable including Exacavation & making of PCC foundation for above pole with all lead lift transportation labour charges & satisfactory test & trial as directed by Engineer in charges .
Supply installation testing and commissioning of 10 KVA ,440/110 V copper wound Dry type step down lighting transformer (ISI Mark) for Gallery power supply complete with all accessories wire, cable, making tapping, arrangement of 90V, 100V & 110 V in Secondary Winding as specification with ISI certification mark & approved make complete with all necessary material all lead lift transportation &labour charges as directed by Engineer in charges.
Supplying & laying of approved make PVC insulated heavy duty cables (conforming to I.S. 1554.1964) 1100 volts grade 31/2 core armoured complete with proper clamping & fitting as per specification with all lead lift transportation &labour charges as directed by Engineer in charge. (1) 25 Sqmm 3.5 core armoured cable (Allu.)
(2) 50 Sqmm 3.5 core armoured cable (Allu.)
Supply installation testing and commissioning of approved make as per IS: 15885/Part-2/sec-13-2012, 12 watt LED Panel down lighting in round/ Square shape complete with all electronic driver heat sink capacitor and all other accessories on surface as per specification & complete with all lead lift transportation & labour charges as directed by Engineer in charges.
Supplying and fixing of PVC board size 1’x1’ for Gallery Lighting complete with all necessary material all lead lift transportation labour charges at site as directed by Engineer in charges.
Supply & fixing Wall / floor mounted Distribution board of welded construction fabrication with minimum 50mm x 50mm x 6mm angle iron frame work with horizontal & vertical intermediate member of suitable angle/flate iron , fire proof sheet with providing & fixing of following items MCCB 100 Amp. 415 V - 1 No. , bus bar 200 Amp. - 3 phase 4 way. - 1 No., Main switch 63 Amp. - 5 Nos. , Amp. meter range 0 to 100 Amp. - 3 Nos., Volt meter 0 to 500V - 1 No. , 3 Phase indicator bulb including C.T. Coil & all necessary control & power cable, as per specification & ISI Marked IS: 13947- Part 1&2 all lead lift transportation &labour charges as directed by Engineer in charges.
Installation, testing and commissioning of all types of street light fittings with all accessories and lamps on street light bracket fixed on wall/ pole, including connection with PVC insulated, copper conductor, Three core cable up to 2 metre length, earthing etc. as required. Complete with all lead lift transportation &labour charges as directed by Engineer in charges.
Supplying & fixing of 100Amp. 3 Phase 440V approved make iron clad/metal clad triple pole switch fuses main switch complete with fixing on 25 x 25 x 5mm angle iron clamp including supplying & fixing of clamp as required dully embedded in masonry including cable connection and other required materials as per specification & IS : 3854 - 1997 with all lead lift transportation &labour charges as directed by Engineer in charges.
Supplying of iron clad/metal clad 100 Amp. approved make bus-bar chambers with tinned copper bus bar as per specification with fixing in require size of flat iron clamp cable connection & other require material complete as per specification & ISI certification marked with all lead lift transportation &labour charges as directed by Engineer in charges.
Supplying and fixing of wall/ floor mounted metal Distribution board size (1.25 x 1 x 0.40m) of welded construction, fabricated with minimum 35 mm X 35 mm X 6 mm angle iron frame work, with horizontal & vertical intermediate members of suitable angle/ flat iron size 25 x 6 mm mounting of switch gear including painting etc. as per specification complete all necessary material arrangement tool tackle all lead lift transportation &labour charges as directed by Engineer in charges.
Replacement of fixing of 3 Phase 5 wire AB cable (By replacing bare conductor) Replacement fixing laying and Testing of approved make LT 3 phase 5 wire AB cable and 11KV 3 phase ABC cable by replacing existing bare conductor of RSP colony Gangrel & dam site. Complete with all necessary material such as Suspension clamp, Piercing connector, Universal distribution connector, Anchor clamp, Straight thought joints, Service ring, Earthing coil, Anchor sleeve , Universal hook, End cap, Cable tie, pole clamp, Eye hook Nut bolt and other Required material arrangement tool tackle all lead lift transportation and deposit of dismantled material from site to store complete as per specification & IS: 14255:1995 with Satisfactory Test & Trail including labour charges as directed by Engineer in charge . 1. LT AB cable size 3 x 70 + 1 x 16 + 1 x 50sqmm x 6% seg.
1. 2. 11 KV 3Phase ABC 3 x 95 + 1 x 16 +1 x 95 sqmm (6% sag) (For Foot Bridge)
3. Distribution box 3 phase 5 connector along with 2 nos Steel Strap & Buckles.
4. Labour charges for laying of 3 phase 5 wire AB cable
5. Dismantling Charge including ( deposit for site to store)
6. Labour charges for laying of 11 KV 3 phase LT Line.
Supplying, installation, testing and commissioning of following Technical detail vehicle mounted SKY Lift/ Light Elevator (SKY MEN) as per latest ISO Mark as per specification & approved make & ISI certification marked 1. Type-Articulated type - 2Boom 2 . Working Height-11m 3.Case height from Ground - 11.5 mtr. 4.Platform Height - 9m. 5.Basket dimensions (m) -1 x1.06 x 0.77m. 6. Self working load capacity - 200 kg. 7. Turning Rotation - 360 degree continuous. Double acting hydraulically operated stability of the vehicle during operation, power required for hydraulic operation to be provided vehicle engine. 8.With New vehicle WB BS- VI norms, Cabin & load body chassis fitted with (PTO) other detail as per specification complete with all lead lift transportation labour charges as directed by Engineer charge. (Before supply of above item drawing & Design with technical specification & other details should be submitted to department for taking approval.)
CONSTRUCTION OF 250KVA SUB STATION STRUCTURE:-- Providing & fixing of H beam size 152x152mm(37.1kg/mtr) weight 13 mtr long pole complete with pit digging , pole erection, pole earthing ,concreting 1:3:6 & pole painting as per specification complete with all necessary material arrangement tool tackles all lead lift transportation &labour charges as directed by Engineer in charges.
Providing & fixing of MS DC cross arm size (100mm x 50mm) 8 feet long with nut bolt washer including painting as per specification complete with all necessary material arrangement tool tackles all lead lift transportation &labour charges as directed by Engineer in charge.
Providing & fixing of DO fuse & LA mounting DC cross arm 75x 40mm all necessary material arrangement tool tackles painting all lead lift transportation &labour charges as directed by Engineer in charge.
Providing & fixing v cross arm with back clamp for cross arm complete with fitting painting transportation &labour charge as directed by Engineer in charge.
Providing fixing and erection of stay set 20mm with stay clamp, stay wire 7/8 SWG,@8.5 kg /pole including pit digging & concreting complete as per specification with all lead lift transportation & labour charges as directed by Engineer in charge.
Providing & fixing of danger board 11KV complete as per specification with all lead lift transportation & labour charges as directed by Engineer in charge.
Construction of transformer foundation size 1.5mtr length x 1.5 m width x 3 mtr height(2 meter above & 1 mtr below in GL ) in RCC 1:3:6 including handling of transformer with excavation of foundation complete as per specification with all necessary material arrangement tool tackles all lead lift transportation &labour charges as directed by Engineer in charge.
Providing & fixing of ACSR conductor 100sqmm AL Eq(DOG) with 3% sag complete jointing & T clamp for jumpering of DO fuse, AB switch & transformer & fixing of terminal clamp as per specification complete with all lead lift transportation lobour charge as directed by Engineer in charge.
Providing & fixing of LT distribution box for 250KVA- Xmer as per specification & latest IEC Mark complete with all lead lift transportation &labour charges directed by Engineer in charges.
SUPPLYING AND INSTALLATION OF DIESEL GENERATOR SET : - Supplying, installation, testing and commissioning of approved make & latest ISO make following capacity silent type diesel Generating set (alternator directly coupled to diesel engine) complete in all respect broadly comprising of following and as per specification (.A). Alternator : Self excited and conforming to IS: 13364/1992 or latest version brush less type, of following capacity, 3 phase, 415 volts, 50 Hz, 4 pole , AC alternator complete with all accessories.(B).Engine : water cooled diesel engine of suitable BHP for rated alternator at 1500 rpm, turbo charged, direct injection type, 4 stroke, 4/6 cylinder including specified size fuel tank of approved design and shape duly calibrated and painted with one coat of primer and two coats of synthetic enamelled paint of approved colour , residential type silencer with exhaust MS pipe (upto 2 metre beyond silenser) duly wrapped with asbestos rope of legging of specified quality and specification.(C) AMF Panel : Cubical , compartmentalized ,AMF panel board with all suitable size power and control contactors , switches , meters and other accessories, internal wiring, connection, inter-connection etc. for trouble free smooth functioning of DG set complete with battery charger and leads as required. (D) Base plate: common base plate of required size for mounting of engine alternator set fabricated from MS channel and vibration damping arrangement with cushy foot mounting i/c painting etc. as required,with proper foundation H -class insulation, Alternator confirming to BS:2613 and latest ISO: 4722 with 12 volt battery &self starting system and standard control panel and all necessary Engine & Alternator safety equipment and accessories complete the work included all expenses cost of material all lead & lift , transportation, Labour charge & satisfactory test & trial as directed by Engineer-in-Charge . a. 125KVA
Supply & fixing of approved make HD copper cable unarmoured single core 70 sq.mm 1100 volts IS 7098-1988, lagging, Termination ,tapping, cable complete as required. the work included all expenses i.e. labour charges cost of scaffolding and necessary arrangement with all lead lift and cost of material as directed by Engineer-in-Charge
Supply & Fixing of wooden board with angle iron frame size 1m x0.75 m ( angle iron size 40mm x40mm x5mm) with fixing of main switch ,cable connection with dully embaded in masonry complete with painting as per specification labour charges cost of scaffolding and necessary arrangement with all lead lift and cost of material as directed by Engineer-in-Charge.
Supply and fixing unclimbable galvanized steel chain link mesh fencing confirming to latest relevant IS code opening size 75x75 mm,2.4 m height made of 8 SWG GI wire fixed to MS angle post of size 65x65x6 mm,2.85 m above GL/Yard level, embedded 700 mm in CC 1:3:6 (400x400) mm below GL at 2.5 m centre to centre and 20 cm thick(200 height ,above GL and 200 below GL) brick masonry in plinth & foundation with cement motor 1:6 including diagonal struts at corner and at every 7th post of angle 65x65x6 mm and horizontal bracing of MS angle of 45x45x6 mm at top and bottom between each vertical post including painting with Aluminium painting with 2 coat on posts struts and chain link mesh 75x75x8 SWG mm size complete as per specification of approved make with all lead lift transportation & labour charges& providing and fixing 3 row of barbed wire minimum weight 9.38 kg per 100 RM etc complete, as per specification & approved make with all lead lift transportation & labour charges as directed by Engineer in charge.
Providing, fabrication & fixing iron gate 3.26x1.8 m (weight approx 300 kg) in RCC column of size 40x40with suitable reinforcement. The iron gate shall consist of MS plate & MS bars as per standard draw in framed by Engineer-in-charge including welding of MS channel 100x50 mm for roller to be fixed for opening of p gate 2 no. 50 mm dia shall be provided with gate including 03 coats of painting etc. complete as per specification with all lead & lift transportation & labour charges as directed by Engineer-in-Charge
Leveling & Moorum filling of substation area complete with all expenses, taxes and all necessary material arrangement tool tackle with all lead lift , transportation and labour charges as directed by Engineer-in-Charge.
Yard metaling with 40 mm crusher broken metal of sub station area the work include all expenses i.e labour charges cost of scaffolding and necessary arrangement with all lead lift , tools tackles ,cost of material transportation and labour charges as directed by Engineer-in-Charge
Open surface drain making of size 250x300(Average internal) with 20cm brick wall 100 mm thick CC 1:3:6 on bed and 1:2:4 coping and cement plaster etc complete as per specification with cost of scaffolding and necessary arrangement with all lead lift cost of material , transportation & labour charge as directed by engineer in charge.
Supply, Erection , Commissioning & Testing of 250KVA, 11/0.43 KV outdoor type Distribution Transformer with Copper winding heaving continuous 250KVA rating , 11/0.43KV 3Phase, 50Hz, Vector Group DY-11, Tapping in step of2.5%, +-5%, +-7.5% with oil conservator, silica gel, breather, heaving connection terminal on HV and LV side conforming to IS:2026 (Part I & II) as per specification & approval make with all fitting, accessories with first filling of transformer oil complete with all expenses, taxes and all necessary material arrangement tool tackles with all lead lift , transportation and labour charges with satisfactory, test & trial as directed by Engineer-in-Charge.
Supplying & laying for PVC insulated heavy duty alluminium cables (conforming to I.S. 1554.1964) 1100 volts, grade 3.5 core, armoured of approved make & specification -the work included all expenses i.e. labour charges cost of scaffolding and necessary arrangement with all lead lift and cost of material as directed by Engineer-in-Charge (1) 95 Sqmm(Al)
(2) 120 Sqmm(Al)
(3) 240 Sqmm(Al)
Supplying & Fixing of approved make iron clad/metal clad triple pole neutral main switch fuses with H.R.C. fuses with fixing on 25*25*5 mm angle iron & clamp as required with duly embedded in masonry including cable connection and other required materials as per specification ISI make with all lead lift , transportation and labour charges with satisfactory, test & trial as directed by Engineer-in-Charge. (a) 63 Amp 415/500 Volts
© 200Amp 415/500 Volts
(e) 400 Amp 415/500 Volts
Supplying & Fixing of approved make iron clad/metal clad 630A 415volt/500VChange over switch (4Pole & neutral link ) with fixing on 35x35x5 mm angle iron & clamp including supplying & fixing of clamps as required with duly embaded in masonry including cable connection and other required materials as per specification ISI make with all lead lift , transportation and labour charges with satisfactory, test & trial as directed by Engineer-in-Charge
Supplying & Fixing of approved make metal clad Bus-Bar Chamber made of 1.6mmthick CRCA sheet with 4 strip copper tined bus-bar of 500Amp capacity & 1500mm length complete as required. the work included all expenses i.e.labour charges cost scaffolding and necessary arrangement with all lead lift transportation, tools tackles and cost of material as directed by Engineer-in-Charge.
Supply Installation Testing and commissioning of approved make 800amp bus-bar duct system as per IEC/ EN 61439- C of free standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shall not be less than 1.6mm up to 600mm length/width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer Area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator). the work included all expenses i.e.labour charges cost of scaffolding and necessary arrangement with all lead lift transportation, tools tackles and cost of material as directed by Engineer-in-Charge consisting of following items below 1) LED pilot lamp 220/240V - 4 no, 2) CT coil 200Amp-6no, 3) danger board-1 no, 4) earthing terminal
Supply making and fixing of approved make 800Amp bus bar in existing substation by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves, Electrolytic grade Copper grade bus bar as per specification & ISI IEC/EN 61439-6 mark the work included all expenses i.e. labour charges cost of scaffolding and necessary arrangement with all lead lift transportation, tools tackles and cost of material as directed by Engineer-in-Charge.
Supply & fixing of approved make 800Amp 4 pole MCCB 50KA in existing substation conforming to IEC 60947-2 & IS13947- Part 1 & 2 bearing capacity 800Amp complete as per specification with all lead lift transportation, tools tackles and cost of material & labour charges as directed by Engineer-in-Charge.
Providing & fixing of approved make of 11 KV AB switch in substations , as per specification with ISI mark the work included all expenses i.e.labour charges cost of scaffolding and necessary arrangement with all lead lift transportation, tools tackles and cost of material as directed by Engineer-in-Charge.
Providing, installation, testing and commissioning of approved make,11 KV 1600 amp outdoor type VCB as per IS 13118 and additional specification suitable for use on 11KV 3 phase 50 Hz AC supply with rated capacity 26.3kA for 3 sec. insulation level 28 kV rms 75 kV peak with heater and spring charging motor operatable on 230 V AC supply with DC supply arrangement (DC source) for relay system complete with all standard accessories as per manufacturers specifications on existing CC foundation (excluding the cost of CC foundation) including connections, earthing the body etc complete as per specification of IEC 62271-200 & ICE 62271-1 including all necessary material arrangement all lead lift transportation & labour charges , tools tackles and cost of material as directed by Engineer-in-Charge
Providing & fixing , erection of approved make 33 KV AB switch in existing 1600 KVA 33/11KV substation as per specification of IEC the work included all expenses i.e.labour charges cost of scaffolding and necessary arrangement with all lead lift transportation, tools tackles and cost of material as directed by Engineer-in-Charge.
Providing , fixing & erection of approved make 11 KV DO set in sub stations , as per specification of latest IEC the work included all expenses i.e .labour charges cost of scaffolding and necessary arrangement with all lead lift transportation, tools tackles and cost of material as directed by Engineer-in-Charge
Supplying and fixing approved make 11 KV glazed porcelain pin insulator with G.I. spindle as per specification of IEC latest on existing pole bracket of sub station with necessary materials as required all lead lift transportation & labour charges as directed by Engineer-in-Charge
Supplying and fixing approved make 11 KV glazed porcelain disc type insulator with tension hardware as per specification of IS: 731-1971 on existing pole/support/ cross arm channel as required in existing sub station complete. all lead lift transportation & labour charges as directed by Engineer-in-Charge
Supplying and fixing approved make 33 KV (3x11 KV) glazed porcelain disc type insulator with tension hardware as per specification of IEC latest on existing pole/support/ cross arm channel of existing 1600 KVA 33/11 KV sub station complete. with labour charges & all lead lift transportation, tools tackles and cost of material as directed by Engineer-in-Charge
Supplying and erection of approved make 33 KV D.O. fuse unit on existing two pole structure with insulators at 1600KVA 33/11KV sub station as per specification of IEC latest and all other accessories complete including locking arrangement as required with labour charges all lead lift transportation, tools tackles and cost of material as directed by Engineer-in-Charge
Supplying and erection of approved make single piece nonlinear resistor type lighting arrestor suitable for 3 wire, 33KV sub station with rated voltage 30 KV (rms) with a nominal discharge current rating of 10KA(station class) and complete with galvanized clamping arrangement, G.I. bolts, nuts, washers etc. as per specification of IEC-26305 as required.(3no of 1 set)complete with labour charges all lead lift transportation, tools tackles and cost of material as directed by Engineer-in-Charge
Supplying and erection of approved make three piece nonlinear resistor type lighting arrestor suitable for 3 wire, 11KV over sub station with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanized clamp in arrangement, G.I. bolts, nuts, washers etc. as required as per specification of IEC-26305 complete. with labour charges all lead lift transportation, tools tackles and cost of material & labour charges as directed by Engineer-in-Charge
Providing and fixing of approved make down conductor with Copper strip size (20x3mm)as per specification of IEC complete including connection to earth electrode riveting/sweating/soldering etc. as required-complete with labour charges all lead lift transportation, tools tackles and cost of material & labour charges as directed by Engineer-in-Charge
Supply Erection Testing & commissioning of approved make 8m height dia135 mm at bottom and 70 mm at top base plate size 225 mm x 225 mm x 16 mm, foundation bolts 750 mm long hot dipped galvanized (single dipped 65 micron) octagonal pole with pole bracket single over hang 1 meter pole made of 3 mm thick steel sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected with following minimum specification including 4 mm thick anchor plate ,4 nos 24 mm dia foundation bolts of EN8 grade (designed for wind speed up to 150 km/hr. ) cement concrete foundation having grouted bolt & nut align in to vertical position as per specification with approved make & IS: 875 - BS 5649 (Part-VI) 1982 mark. Complete with all necessary arrangement tool tackles all lead lift transportation & labour charges at RSP site as directed by Engineer in charge.
Supplying laying and fixing of approved make PVC insulated 2 x 1.5 sq.mm, PVC sheathed, steel armoured, copper conductor control cable of 1.1 kv grade direct in ground including excavation ,sand cushioning, protective covering an refilling the trench etc. as per specification & IS: 1544 (Part-I)1988 including all lead lift transportation & labour charges at RSP site as directed by Engineer in charge.
Providing and erecting of floor mounted sand/ water bucket stand for keeping 4 nos. of fire bucket, 1500 mm in length and 900 mm in height made out of 30 X 30 X 4 mm angle iron welded with 4 hooks and duly painted with one coat of zinccromate primer and 2 coat of synthetic enamel paint of post box red colour etc as specification with all lead lift transportation &labour charges at RSP site as per directed by Engineer in charge.
Supplying & fixing of G.I. Fire buckets with round bottom having at least 9 lit. capacity duly painted with one coat of zinccromate primer and 2 coat of synthetic enamel paint of post box red colour and filled with dry sand and kept on provided wall hook or stand etc with all lead lift transportation & labour charges at RSP site as directed by Engineer in charge.
Supply and laying SMC chequered sheet in size 1 m x 1 m x 2.5mm (thick) to withstand 33 KV Electrical stress near HT or 11 KV LT panel etc as per specification of IEC latest with all lead lift transportation &labour charges at RSP site as directed by Engineer in charges.
Supply and erecting of approved make CO2 type 3 kg ,ISI 1183 - 1996 marked Fire extinguishers on wall/ column including erecting bracket etc complete. as per specification of with all lead lift transportation &labour charges at RSP site as directed by Engineer in charge.
RE-INTERNAL ELECTRIFICATION OF G, H , A & I TYPE QUARTER : - Point wiring for light point with 1.5 sq. mm PVC Insulated cable with aluminium conductor of approved make in concealed rigid (PVC) non-metallic conduit of suitable size as required including all expenses i.e labour charges cost of scaffolding, tools and tackles , all necessary arrangement with all lead & lift cost of cutting outer plaster & making good all work disturbed notching or drilling hole through joint etc .cost of flush type switch board Alluminium conductor saddle charges , nail charges , screw , plug, wooden plug ,phil plug, rawl plug, ceiling rose, flash type fuse complete for each cost of all material as per drawing & specification as directed by Engineer-in-Charge a-short point
b-medium point
c-long point
d-special point
Point wiring for fan/exhaust fan point with 1.5 sq. mm PVC Insulated cable with aluminium conductor of approved make in rigid surface (PVC) non-metallic conduit of suitable size as required as per specifications.& latest ISO make including all expenses i.e labour charge cost of scaffolding, tools & tackles , all necessary arrangement with all lead lift cost of cutting out plaster & making good all work disturbed notching or drilling hole through joint etc .cost of flush type DP switch , board , alluminium conductor etc cost of all material as per drawing, specification and as directed by Engineer-in-Charge a-short point
b-medium point
c-long point
Supplying & fixing of Point wiring for call-bell/buzzer point with 1.5 sq. mm PVC insulated cable with aluminium conductor of approved make in concealed rigid (PVC) non-metallic conduit of suitable size as required as per specifications complete with labour charge as directed by Engineer in charge. (c) Long point
Point wiring for 3 pin 5 Amps. socket outlet point with 1.5 sq. mm PVC insulated cable with aluminium conductor of approved make in rigid surface (PVC) non-metallic conduit of suitable size with required materials as per specifications on same board including all expenses i.e labour charge cost of scaffolding, tools & tackles , all necessary arrangement with all lead lift cost of all material 3 pin 5Amp socket , flush type switch , screw , wiring etc as per drawing specification and as directed by Engineer-in-Charge
Wiring for circuit wiring with PVC insulated cable with aluminium conductor of approved make in surface rigid (PVC) non-metallic conduit of suitable size as required including all expenses i.e labour charge cost of scaffolding, tools & tackles , all necessary arrangement with all lead lift cost of cutting out plaster & making goods all the work disturbed , notching or drilling hole through joint etc .cost of length of wiring of circuit will be from distribution board upto tapping point cost of all material as per drawing, specification and as directed by Engineer-in-Charge. (a) 2x1.5 sq. mm (1 circuit)
(b) 4x1.5 sq. mm (2 circuit)
Providing and fixing earthing arrangement with 38.1 mm dia 2.5 meter long galvanized iron pipe electrode, including packing of charcoal powder and salt as per specification, watering pipe 19 mm dia G.I. connections, etc. complete with refilling the pit as required, but excluding the excavation of earth pit complete with transportation &labour charges as directed by Engineer-in-Charge.
Providing and laying aluminium earth continuity conductor ISI marked of 4 sq. mm along the run of final sub-circuit duly installed inside casing, or batten or PVC conduit in an approved manner complete as per specification with transportation & labour charges as directed by Engineer-in-Charge
Supplying and fixing as per specification brass batten holder/angle batten holder of approved make with necessary materials complete as per specification labour charge as per directed by Engineer in charge.
Supplying and fixing as per specification rigid steel conduit of approved make in surface (open) conduit wiring system with iron screws, check nuts, saddles, bends, toes etc. including painting as required as ISO latest complete with labour charge as directed by Engineer in charge. (a) 20 mm conduit
Supplying and fixing as per specification Bulk head fittings of approved make suitable for 100 watt lamp with necessary materials complete with transportation & labour charge as directed by Engineer in charge. (a) Ordinary
supplying and fixing of approved make iron clad/metal clad double pole switch fuses 32 Amps 250 volts with metal clad/iron clad switches on 25x5 mm flat iron clamps including of clamps as required duly embedded in masonry including cable connection and other required materials as per specification latest ISO mark the work included all expenses i.e.labour charges cost of scaffolding and necessary arrangement with all lead lift transportation and cost of material as directed by Engineer-in-Charge.
Supplying and installing iron clad weather proof cut-outs of 15/16 Amps 500 volts approved make on existing pole or surface board/box with necessary materials complete including fixing and connection etc as per latest ISO mark the work included all expenses i.e.labour charges cost of scaffolding and necessary arrangement with all lead lift transportation cost of material and as directed by Engineer-in-Charge.
Wiring for sub-mains with PVC insulated cable with aluminium conductor of approved make in surfaced rigid steel conduit of suitable size including connections, painting etc. as required as per specifications latest ISO mark complete with all lead lift transportation and cost of material & labour charges as directed by Engineer-in-Charge. (A) 2 Wire Sub-mains (ii) 4 sq. mm cable in 20 mm conduit
Providing & fixing approved make electric ceiling fan 1200mm sweep complete with standard down rod, canopy, hanging shackle blades and speed regulator suitable for operation on 230/250 volts A.C. supply as per latest ISO - 374: 2019complete with all lead lift transportation and cost of material & labour charges as directed by Engineer-in-Charge.
Erection of ceiling/cabin fan Regulator on TW boards. in position including wiring, fixing regulator testing etc. with necessary materials complete as required as per specification complete with all lead lift transportation and cost of material & labour charges as directed by Engineer-in-Charge.
Supplying and fixing fan clamps with hook on existing T.W. Beam trusses with required size flat iron etc. as per specification complete(as per latest ISO complete with all lead lift transportation and cost of material & labour charges as directed by Engineer-in-Charge.
Supplying and installing approved make (overhead) service wire two core 4sq.mm with PVC insulated flate cable suspended on existing bearer wire in an approved manner as per specification with bobbin insulators etc, or drawn in existing G.I. pipe brackets. or conduit pipe etc. wherever required including connection, testing etc as per latest ISO complete with all lead lift transportation and cost of material & labour charges as directed by Engineer-in-Charge.
Providing and fixing service clamps of G.I. pipe 19 mm diameter 3 meter long duly fixed on wall / masonry in an approved manner for service entries, complete with all materials as required. ISI marked the work included all expenses i.e.labour charges cost of scaffolding and necessary arrangement with all lead lift transportation and cost of material as directed by Engineer-in-Charge.
Supplying and fixing 15 Amps 250 volts 3 pin flush type socket outlets PB of approved make with necessary materials complete as per latest ISO complete with all lead lift transportation and cost of material & labour charges as directed by Engineer-in-Charge.
Supplying & fixing of approved make distribution fuse boards, single pole and neutral 15/16 Amps 250 volts per way-i. 2 way clad/distribution boards on 25x5 mm flat iron clamps including supplying and fixing of clamps as required duly embedded in masonry including cable connection and other required materials as per specification complete with all lead lift transportation and cost of material & labour charges as directed by Engineer-in-Charge.
Supplying and fixing in position of approval make 20 watt compact fluorescent lamp(CFL) complete all lead lift transportation and cost of material & labour charges as directed by Engineer-in-Charge.
Providing & fixing of Approved make speed regulator Electronic type only for A.C. fans all sizes complete all lead lift transportation and cost of material & labour charges as directed by Engineer-in-Charge.
Supply & erection of approved make Wall mounting exhaust fan of 380mm 900rpm in position with required VIR TBC cable, frame, bolts,complete with motor, mounting frame, blades, etc.- as per latest ISO complete with all lead lift transportation and cost of material & labour charges as directed by Engineer-in-Charge.
Supply installation Testing & commissioning of approved make of single phase Electronic Energy meter range 5-20amp frequency 50hz with safety box & locking arrangement as per IS: 13779(1999) complete with all lead lift transportation and cost of material calibration & labour charges as directed by Engineer-in-Charge.
Providing & fixing of approved make LED Tube light Set 20watt Complete as per specification complete with all lead lift transportation and cost of material & labour charges as directed by Engineer-in-Charge
Providing & fixing of approved make 9 Watt LED Bulb as per specification complete with all lead lift transportation and cost of material & labour charges as directed by Engineer-in-Charge
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid