| 1 | L1₹36.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹41.4 L+₹4.2 L (11.3%)Rejected-Finance RONGMEN B IV BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹42.3 L+₹5.2 L (13.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹42.8 L+₹5.7 L (15.3%)Rejected-Finance C O SIMPLICITY LYNGDOH LOWER LUMPARING LABAN SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹43.1 L+₹6.0 L (16.1%)Rejected-Finance RONGMEN B IV BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
16 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Umroi
Military Engineer Services Garrison Engineer Umroi Umroi Military Station PO - Barapani, Shillong-793 103
REPAIR AND RENEWAL OF CERTAIN B AND R SERVICES IN ZONE I AND ZONE II OF UMROI MIL STN UNDER GE UMROI
2023_MES_589598_1
8708/E8
Open Tender
Civil Works
Item Rate
180 days
Umroi
As per NIT
8 documents required · 8 mandatory
₹500
GE Umroi
₹80,000
19 Jun 2023
15 Apr 2023
17 May 2023
15 Apr 2023
16 May 2023
29 Apr 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling AC/CGI/PPGI corrugated or semi corrugated sheets in wall cladding or roof coverings and hanger doors including ridges and make good for aluminium earthing strips after fixing of sheets, complete all as specified and directed.
Taking down door frame or Chowkhats or frames exc. 1.5 sqm but n.exc 4.0 sqm each (without taking off shutter from the frame) complete all as specified and directed.
Taking down door frame or Chowkhats or frames n exc. 1.5 sqm each (without taking off shutter from the frame), complete all as specified and directed.
Taking down Shutters of any description n exc 1 sq. m each, complete all as specified and directed.
Taking down Shutters of any description exc 1 sq. m but n.exc 2.0 Sqm each, complete all as specified and directed.
S&F Factory made solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed single side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet, complete all as specified and directed.
S&F Factory made solid PVC moulded door shutter 28 to 30mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm PVC sheet on back face, fixing in frame at site as per specification & drawing, complete all as specified and directed.
S&F second class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
S&F second class hard wood 35mm Glazed and skeleton shutters, for door and window (Glazed/Gauzed) open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and directed.
S&F second class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats, complete all as specified and directed.
Cleaning of PVC water tanks of capacity 500 litres including chemical treatment with Anti-bacterial agent consisting of following process: - Dewatering the tank with submersible pump, de-silting and removing of left over dirty water up to 100 to 150 mm in the bottom of the tank and sludge with special sludge pump, cleaning of walls and ceiling with special mechanized high pressure jet machines by rotary jet system at 100-120 Bar pressure (120 Kg /sq cm) which dislodges the layer of dirt, algae, fungus stuck on its surface usage of scrubbing machines for old stains and cleaning chemicals if required of make Eureka Forbes Ltd, floor of the dirty tank should be thoroughly cleaned up by fry jet cleaner to accumulate all dirt ,the remaining sludge should than be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial Vacuum Cleaners to make the floor totally dirt free, application/spraying of Anti-Bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 ft long ultraviolet Radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the above operations should be executed by trained workers and technicians with paint 75 mm height in DD/MM/YY patern and refixing the cover after cleaning all and specified and directed.
Cleaning of PVC water tanks of capacity 1000 litres including chemical treatment with Anti-bacterial agent consisting of following process: - Dewatering the tank with submersible pump, de-silting and removing of left over dirty water up to 100 to 150 mm in the bottom of the tank and sludge with special sludge pump, cleaning of walls and ceiling with special mechanized high pressure jet machines by rotary jet system at 100-120 Bar pressure (120 Kg /sq cm) which dislodges the layer of dirt, algae, fungus stuck on its surface usage of scrubbing machines for old stains and cleaning chemicals if required of make Eureka Forbes Ltd, floor of the dirty tank should be thoroughly cleaned up by fry jet cleaner to accumulate all dirt ,the remaining sludge should than be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial Vacuum Cleaners to make the floor totally dirt free, application/spraying of Anti-Bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 ft long ultraviolet Radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the above operations should be executed by trained workers and technicians with paint 75 mm height in DD/MM/YY patern and refixing the cover after cleaning all and specified and directed.
Cleaning of PVC water tanks of capacity 2000 litres including chemical treatment with Anti-bacterial agent consisting of following process: - Dewatering the tank with submersible pump, de-silting and removing of left over dirty water up to 100 to 150 mm in the bottom of the tank and sludge with special sludge pump, cleaning of walls and ceiling with special mechanized high pressure jet machines by rotary jet system at 100-120 Bar pressure (120 Kg /sq cm) which dislodges the layer of dirt, algae, fungus stuck on its surface usage of scrubbing machines for old stains and cleaning chemicals if required of make Eureka Forbes Ltd, floor of the dirty tank should be thoroughly cleaned up by fry jet cleaner to accumulate all dirt ,the remaining sludge should than be removed by sludge pumps, the dirt silt and other foreign material should further be removed by Industrial Vacuum Cleaners to make the floor totally dirt free, application/spraying of Anti-Bacterial chemicals to ensure total sterilization of tank from the inside, inside of the tank should be treated with specially developed 4 ft long ultraviolet Radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water. All the above operations should be executed by trained workers and technicians with paint 75 mm height in DD/MM/YY patern and refixing the cover after cleaning all and specified and directed.
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:4) in two layers mixed with liquid water proofing compound as per manufacturers instruction in top layer 5 mm thick finishing the surfaces even and smooth without using extra cement including Taking down of cement plaster of any description including racking out joints for key scrubing with water complete all as specified and directed. . Note: Liquid water proofing compound shall be measured and paid seperately. Make - Conplast WL,Sika,Dr.Fixit measure separtely.
Supply only integral WPC ( Integral waterproofing liquid admixture for cement mortar) and application as per manufacture instruction all as specified and directed by Engr-in-charge. Make - Conplast WL, Sika, Dr.Fixit
M&L for rendering 15mm thick in cement mortar (1:6) internal surfaces on other than fair faces of brick work or concrete surfaces complete all as specified and directed.
M&L for preparing surfaces of newly plastered surfaces on walls and applying two coat of distemper oil emulsion including 1.5mm thick external wall putty with alkali resistant primer, complete all as specified and directed.
M&L for preparing surfaces of newly plastered on walls and applying two coat of acrylic smooth exterior paint including 1.5mm thick internal wall puty with alkali resistant primer, complete all as specified and directed.
M&L for Non - skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but notexceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed.
M&L for 15mm thick screed bed or bedding laying of cement mortar (1:6), for as in floor finishes, complete all as specified and as directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade, complete all as specified and as directed.
M&L for powder coating of any colour (minium thickness 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and as directed.
M&L for powder coating of any colour aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.), complete all as specified and as directed.
Supply & Fix 4mm thick sheet glass, ordinary quality, glazing in square/rectangle n. exc 0.50 sqm each pan with oil putty or aluminium beads fixed to steel etc, complete all as specified and as directed.
S&F in repair 19mm thick prelaminated block board, grade 2 quality, interior grade, commercial type as in cupboard shutter/kitchen cabinates including (Al handdle, MS hinges, PVC knobs and necessary fixing items as per standared engineering practice), complete all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed.
S&F false ceiling of designer tile ivory painted (high pressure steam cured ) of 4mm thick (as per IS: 14862) of size 595x595mm and any one of the design (cascade or electra) in true horizontal level. Suspended on inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms both side inclusive and black painted groove on all T webs)consisting of main T runner with suitably spaced joints to get required length and 15x32mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 15x32mm made of 0.3mm sheet 1200mm long spaecd between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 15x32mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturers instructions/literature. GI adjustable wire of 4mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 4mm dia GI wire shall be pre-painted with with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width, including taking down old false ceiling board of any description alongwith rails and connecting items, complete all as specified and directed.
S&F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ridge/ cladding to wall, fixed with self tapping screw in roofs, complete all as specified and directed.
M&L for complete removal of existing treatment on walls and applying two coat of distemper oil emulsion including internal wall putty 1.5mm thick with alkali resistant primer,, complete all as specified and directed.
M&L for complete removal of existing treatment on walls and ceiling and applying two coat of acrylic smooth exterior paint (weather coat) including 1.5mm thick external wall puty with alkali resistant primer, complete all as specified and directed.
Demolition of RCC with concrete cutter machine of any description and in any position not otherwise specifically provided for including taking out and seperating old reinforcement and removal of debries to a distance not exc 50m as directed by Engineer in charge and making site clean, complete all as specified and directed.
Supply and fix rotational moulded,multilayer HDPE water storage tank of 500 ltrs capacity( tripple layer wall construction , Cylindrical vertical with closed top) ISI marked hoisted and fixed in position all as specified in SSR Part I including 02 Nos 20 mm bore full threaded GI nipple of required size including ball valves 20 mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm - 210gms and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed
Supply and fix of rotational moulded,multilayer HDPE water storage tank of 1000 ltrs capacity( tripple layer wall construction , Cylindrical vertical with closed top) ISI marked hoisted and fixed in position all as specified in SSR Part I including 02 Nos 20 mm bore full threaded GI nipple of required size including ball valves 20 mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm - 210gms and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed.
Supply & fix 20 mm bore gun metal, globe or gate valves ISI marked with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
S&F for stop valves fancy type chromimum plated cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe CPVC pipe or for union and of size 20 mm bore complete all as specified and directed.
Fixing only 20 mm bore gun metal, globe or gate valves ISI marked with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
fixing only stop valves fancy type chromimum plated cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe CPVC pipe or for union and of size 20 mm bore complete all as specified and directed.
Taking up or down GI tubing 15/20mm bore from wall/ceilings including all fittings segrated and stacking the pipe, complete all as specified and directed.
S&F CPVC pipes of 20 mm outside dia, SDR 11 and plain CPVC SDR 11 fittings on walls/ ceiling or laying in wall/ceiling or laying in floors, complete all as specified and directed.
Supply & Fixing 3-layer PP-R Polypropylene random copolymer) of 20 mm outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. with all fittings and fixed complete to wall and ceiling or laid in floors and making connection with old GI tube/PPR pipe using suitable section complete leakproof, complete all as specified and directed.
Material and labour for taking down of existing roof treatment from roof and terrace, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following steps and specifications:- a) Applying crack seal compound of same manufacture of waterproof to fill all cracks of observed on the roof. b) Applying cement slurry over concrete surfaces @3kg/sqm. c) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound as per manufactures’ instruction(not less than 3% by weight of cement) on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course). d) Applying evenly one coat of primer coating (diluted with water in the ratio specified by Manufacturers) (min @100-110Sq Ft per liter (diluted quantity)) on the cleaned plastered surfaces. The surface shall be left for air dry for minimum period of 2-3 Hrs. e) Applying evenly one coat of elastomeric water proof coat in one direction (as specified by Manufacturers)(min@ 0.9-1.0 sqm per ltrs) and allow to air dry for 4-6 hrs before applying second coat in other direction perpendicular to the first one (as specified by Manufacturers) (min @0.9-1.0 sqm per ltrs. The total thickness of two coats shall be 0.5 to 0.6 mm. f) The whole system shall be left for air cure for min Seven days (without any movement). Make : - STP ShaliCryl LM or Dr Fixit Newcoat Ezee or Berger Home Shield PU RoofKoat or Asian Paints Smartcare Damp Proof , FOSROC or SIKA or as equivalent approved by GE. Note : - (i) The waterproofing shall be carried out in the last stage of execution to avoid any damages during the execution. (ii) Payment against this item shall not be allowed till completion of all the stages of work for any slab. (iii) Product should confirm ASTMD-6083 (iv) The work shall be executed through Authorised well-trained applicators as per manufacturer’s instructions after obtaining written approval from the GE
Schedule of Credit
M/s Jaiswal and Co
M/S C.M.V CONSTRUCTIONS
Lyngdohs Construction Company And Associates
M/S UB ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .