Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹121.6 Cr
EMD Value
₹1.3 Cr
Closing Date
21 May 2025, 5:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Facilities Management Division, Bangalore
HINDUSTAN AERONAUTICS LIMITED Facilities Management Division, Bangalore
Construction of GTC Hangars Transmission Assembly Test Hangars comprising of Civil Electrical and Mechanical Works at RWRDC Division HAL DC Bangalore Package I for IMRH Project
20386
TENDER NOTICE/NCP/66/24-25 /01
Works
Contract Section Civil-FMD-Bangalore
₹0
₹1.3 Cr
21 May 2025
2 Apr 2025
2 Apr 2025
21 May 2025
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Year of Estblishment of Company/Business
If Other, please specify
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, etc.,
Address for correspondence:
TIN number
PAN no and Name of Holder
PF number (If any)
ESI number
Service Tax Registration No
Goods and Service Tax ID No.
SAC Code
Contact details
Registered Contractor
Pls Enter
Need to Fill Column 19
Maximum value of works excuted during the followinf 5 years. . (In Lakhs)
Pls enter Finiancial Turnover in Rupees for all the years
DETAIL OF WORK ON HAND UPTO N-Months (N-contract period) [For Bid capacity calculation] NOTE : PROVISION for 10 works are given. If more, a separate similar sheet to be made showing all the works with all details as per this FORMAT and same to Uploaded. However, 9 works details to be provided and balance work value of other works to be added and to be provided in 10th row as OTHER works.
Name of Organization with address
Balance Work On Hand
Work Schedule for completion of works with in stipulated time [Please enclose action plan / bar chart as to indicate the completion of work, within the scheduled time (contract period)]
Quantity of work Excuted during the last three years
Bank(s) details: [Copy of the cheque leaf to be uploaded]
Bank Account No.
Bank Statement for past three month
Latest Over draft Facilties with Bank enter Name of Bank, Date of Issue and Value of Over Draft
Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued NOT before 12 months from the date of Tender Notice.
#VALUE!
Experience of having successfully completed similar works during last 7 years ending last day of previous month. [Work experience certificates / Completion certificates should be uploaded for verification]. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of the estimated cost. [Amount put to the Tender]
You are Not Eligible
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
work done
Type of Work and Organisation name [ Incase of private works the same shall be supported with TDS certificate]
#VALUE!
Related Document to be Uploaded to eProcurement Portal
DEAILS OF TECHNICAL PERSONNEL AVAILABLE( if space provided is insufficant separate sheet to be uploaded with the same format as below)
Name of members or technical personllel avalable in the organization
DETAILS OF MACHINERY AVAILABLE
Name of Mechinery
Concrete Mixers - Type etc
Vibrators - Diesel - Electrical
Weiding equipment's
a) Rectifiers
b) Welding Generators
Erection equipment's
Cranes-
Hoists-
Lifts-
Water Lifting motor pumps
a) Diesel
b) electric
Drilling Equipment's
Compressors
Trucks
Stone crushers
Bitumen hot mixture plant
Bitume boiler
Rollers
Batching plants
Vibratory rollers
Generators
Cranes-Details
Concrete pumps
Road Pavers
Rock breakers
Transit mixers
Excavators
Weight batches
Others
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
DECLARATION
Pls enter
Tender Document Cost and EMD details
Enclosed / Not enclosed
Enclosed
Enclosed
Average annual financial turn over during the last 3 years, ending 31st March 2024 [ should not be less than 30% of amount put to tender] and details for last 5 years to be provided to assess the bid capacity. The values provided to be supported by uploading Balance Sheet along with Profit & loss account statement. . (In Lakhs)
Specification
Removing / Disposal of surplus earth / moorum / building rubbish / malba / similar unserviceable, dismantled or waste material of partitions, ceiling boards, tiles, frames, etc., by mechanical transport including loading, transporting, unloading in all lifts / loads upt 10km distance from HAL, etc., completely as per directions of Engineer-in-Charge.
Earth work in surface excavation in all kinds of soil not exceeding 30cm in depth but exceeding 1.50m in width as well as 10Sq m on plan including getting out and disposal of excavated earth along with vegatation if any upto 50m and lift upto 1.50m, etc., as directed by Engineer-in- Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas in all kinds of soft / hard soil for foundations, footings, columns, pedestals, Plinths or members as per the drawing, etc., (exceeding 30cm in depth, 1.50m in width as well as 10Sq m on plan) including removal of vegetation and in-equalities, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, levelling, ramming the bottom of excavation, getting out and disposal of excavated earth lead upto 50m and in all lifts with all labour, tools & tackles, plant & machinery, hire & fuel charges, etc., all complete as directed by Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains, pipes, cables, etc., in all kinds of soils (not exceeding 1.50m in width or 10Sq m on plan), including dressing of sides and ramming of bottoms, for all lifts, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m with all labour, tools & tackles, plant & machinery, hire & fuel charges in all depths and lifts, etc., all complete as directed by Engineer-in Charge.
Excavating trenches of required width in all kinds of soils laying of for pipes, Conduits, Cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.50m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m for Pipes of Dia not exceeding 300mm dia, etc., all complete as directed by Engineer-in Charge.
Returning / filling in with useful excavated soil (excluding rock), free from salts, organic or other deleterious matter (Other than black cotton soil & rock, etc., in trenches, plinth, sides of foundations, etc., spreading in layers not exceeding 20cm thick, watering, breaking / removing clods exceeding 50mm, ramming and consolidation of each deposited layer, etc., with all labour, tools & tackles, plant & machinery, etc., lead upto 50m and for all lifts, etc., all complete as directed by the Engineer-in-Charge. Note: Quantity to be paid to agency as per Survey Level sheet.
Supplying chemical emulsion Chlorpyriphos / Lindane or any other equivaent make emulsifiable concentrate of 20%) in sealed containers including delivery as specified, etc., all complete as directed by the Engineer-in-Charge.
Diluting and injecting chemical emulsion with 1% concentration for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / Sq m of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding, etc., all complete as directed by the Engineer-in-Charge. Note: The activity to be carried out through autrhorised specialised agency and who has executed similar services for Industrial Building Area. A performance guarantee bond for 10 years on non-judicial stamp paper of Rs. 500/- shall be given by the contractor. The 10% of completed value of this item shall be dedcuted as defect liability deposit and the same shall be returned after sucessful completion of 10 years from the date of completion of contract / project as a whole.
Diluting and injecting chemical emulsion with 1% concentration for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre includ ing drilling and plugging holes, etc., all complete as directed by the Engineer-in-Charge. Note: The activity to be carried out through autrhorised specialised agency and who has executed similar services for IndustriaL Building Area. A performance guarantee bond for 10 years on non-judicial stamp paper of Rs. 500/- shall be given by the contractor. The 10% of completed value of this item shall be dedcuted as defect liability deposit and the same shall be returned after sucessful completion of 10 years from the date of completion of contract / project as a whole.
Providing and laying in position cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level, including mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions, etc., but excluding the cost of centering and shuttering, etc., all complete as directed by the Engineer-in-Charge.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, etc., all complete as directed by the Engineer-in-Charge.
Supplying, mixing and placing plain cement concrete (1:2:4) of required thickness using 20mm nominal size down graded hard stone/granite aggregate in accordance with IS 456 in posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, plinth area, etc., including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions, etc., but excluding the cost of centering, shuttering and finishing, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing at or near ground level precast cement concrete of ratio (1:1½:3 ) in kerbs, edgings, etc., as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering, curing, etc., all complete as per the direction of Engineer-in-Charge.
Formwork by providing timber, wooden planks, runners / M.S. sheets with all supports, struts, braces, wedges, scaffolds, bracings, ladders, gangways, dressing with oil including M.S. bolts nuts and washers, temporary openings, filleting for a stop, chamfered edges, internal / external splayed, rounded angles or grooves for forming throating including making temporary openings in the forms for pouring concrete, etc., as per drawing, etc., all complete as directed by the Engineer-in-Charge Note :Formwork material is contractor's own property and shall be removed after completion of work.
Foundations, pile caps, footings, bases of columns / pedestal, Lift walls, cable trenches, drainage walls, for mass concrete, etc.,
For Columns, Pillars, Piers, Abutments, Posts and Struts
For plinth beams, LinteL beam with chajja, Tie beams, Roof beams, girders, bressumers, chajjas projection, cantilevers.
For Roofs, landings, suspended floors, Slabs supported on walls, roofs, landings, balconies, access platforms, Gutters, decks, etc.,
For Staircase excluding Landing
For Walls (any thickness) including attached pilasters, butteresses, plinth and string courses, etc.,
Extra for additional height in centering, shuttering for Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) where ever required with adequate bracing, propping, etc., including cost of de-shuttering and decentering at all levels, height of around 4.60m as against 3.50m standard height (Plan area to be measured).
Extra for additional height in centering, shuttering for Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) where ever required with adequate bracing, propping, etc., including cost of de-shuttering and decentering at all levels, height of around 5.60m as against 3.50m standard height (Plan area to be measured).
Extra for additional height in centering, shuttering for Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) where ever required with adequate bracing, propping, etc., including cost of de-shuttering and decentering at all levels, height of around 6.60m as against 3.50m standard height (Plan area to be measured).
Extra for additional height in centering, shuttering for Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) where ever required with adequate bracing, propping, etc., including cost of de-shuttering and decentering at all levels, height of around 7.60m as against 3.50m standard height (Plan area to be measured).
Extra for additional height in centering, shuttering for Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) where ever required with adequate bracing, propping, etc., including cost of de-shuttering and decentering at all levels, height of around 9.60m as against 3.50m standard height (Plan area to be measured).
Extra for additional height in centering, shuttering for Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) where ever required with adequate bracing, propping, etc., including cost of de-shuttering and decentering at all levels, height of around 10.60m as against 3.50m standard height (Plan area to be measured).
Extra for additional height in centering, shuttering for Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) where ever required with adequate bracing, propping, etc., including cost of de-shuttering and decentering at all levels, height of around 12.60m as against 3.50m standard height (Plan area to be measured).
Supplying, straightening, fabricating (cutting & bending), placing in position and binding steel reinforcement of TMT bars of not less than Fe 500 D conforming to IS 1786 for all concrete reinforcment members / works above/below plinth level, including cutting to length, bending to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with mild steel wire (Annealed) not less than 0.90mm dia or securing with clips, including fixing and bracing, wastage, welding, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it, etc., complete all as per specifications, drawings and as directed by the Engineer-in-Charge. Note: a) Only authorized laps, chairs etc. shall be considered for measurement. b) The exposed Reinforcement bars shall be coated with cement slurry.
Providing and laying in position ready mixed or site batched M25 Grade with minimum cement content of 330 kg/m3 design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, consolidation, levelling, curing, scaffolding, all materials, labour, carriage for all leads & lifts; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-Charge. Note: (i) Mix design to be obtained from Govt. / NABL laboratory for site batching concrete.
All works upto plinth level like footing, pedetsal, trenches, plinths, mass concrete including necessary openings and packing if any for laying pipes, cables, etc.,
All works above plinth level like Column, beams, slabs, Brakets, canopy, chajja, sunshades, stairscases, Floors, gutters, etc., including necessary openings and packing if any for laying pipes, cables, etc.,
Providing and laying in position ready mixed or site batched M30Grade with minimum cement content of 350 kg/m3 design mix cement concrete for reinforced cement concrete work; upto plinth level like machine foundations / pedestals for motors, including necessary openings and packing if any for laying pipes, cables, etc., using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, consolidation, levelling, curing, scaffolding, all materials, labour, carriage for all leads & lifts; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-Charge. Note: (i) Mix design to be obtained from Govt. / NABL laboratory for site batching concrete.
Providing and fixing in position minimum 200mm wide Stainless steel Grade 304 plate of 1.0mm thick as per design for expansion joints in vertical direction towards external wall surface to protect from rain water entry after applying a selant / expansion boards, etc., all complete as directed by Engineer-in-Charge. Note: MTC for the plate to be submitted to EIC.
Providing and fixing of expansion joint system related with floor location (100mm gap). The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor / floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall confirm to ASTM 6063).
Providing and fixing of expansion joint system related with wall joint of approximately 100mm gap (internal/external). The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall / wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063), All the work to be completed and make leak proof as per the direction of Engineer-in-Charge.
Providing and fixing of 100mm expansion joint system of approved make and manufactures for various roof locations. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). All the work to be completed and leak proof as per the direction of Engineer-in-Charge.
Supply and Construction of Sized stone masonary works with CM(1:6) in foundationand plinths by placing the stones in layers, packing, leveling, curing and finishing the joint, etc., all complete as per the Instruction of Engineer-in-Charge.
Providing and fixing expansion hold fasteners on C.C. / R.C.C. / Brick masonry surface backing including drilling necessary holes and the cost of bolt of Wedge expansion type, etc., all complete as per direction of Engineer-in-Charge.
Fastener with threaded dia 6mm
Fastener with threaded dia 10mm
Providing and fixing Granite stone slab of with (18mm to 25mm thick), area of slab not less than 0.5Sq m, like Ruby Red / Black / Cherry with gang saw cut, mirror polished, premoulded and prepolished, machine cut for platforms, vanity counters, and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish, etc., complete at all levels as per direction of Engineer-in-Charge.
Providing and fixing in wall lining flat pressed three layer (medium density) particle board of 12mm thick or graded wood Pre-laminated one side decorative lamination and other side balancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed arrangement and screws, etc., complete all as per the direction of Engineer-in-Charge.
Designing, fabricating, testing, installing and fixing in position Curtain Wall system comprising of ACP sheet cladding of approved colour and design with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc and with structural sealant, including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc and also with 6mm thick high performance glass. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts, SS bolts with washer of different sizes for structural glazing/ACP Cladding, all complete required to perform as per specification and drawing
Providing and fixing Second Class Teak wood for frames of doors, windows, hand rails, frame work of size approximately [100 x 75]mm for partitions, cut to shape and required curvature and preparing the surfaces to receive the polishing fixed in position with hold fast lugs / with dash fasteners of required dia & length / SS Screws at all heights, with necessary moisture content test, etc., complete as per direction of Engineer-in-Charge. (Fastners / hold fasts / SS Screws to be paid separately)
Providing [40 x 5]mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block [30 x 10 x 15]cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size), etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing 35mm thick flush door shutters conforming to IS :2202 (Part I) non-decorative type of approved brand / make, core of block board construction with frame of 1st class hard wood & lipping with 2nd class teak wood battens 25mm minimum depth on all edges and well matched commercial 3ply veneering with vertical grains or cross bands including ISI marked Stainless Steel butt hinges with necessary screws and face veneers on both faces of shutters and making rectangular vision panel of 0.10Sq m with 6mm thick clear heat strengthened glass, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing panelling minimum 5mm thick glass panes for glazing in panelled or glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section [90 x 45]mm having single rebate of [32 x 15]mm to receive shutter of 30mm thickness for opening size approximately [0.75 x 2.10]m. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing 30mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish including accessories made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856 of approved brand/type, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing bright finished brass handles of 125mm size with screws, etc., complete as per direction of Engineer-in-Charge.
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc., complete as per direction of Engineer-in-Charge.
Providing and fixing bright finished brass tower bolts of [250 x 10]mm (barrel type) with necessary screws, etc., complete as per direction of Engineer-in-Charge.
Providing and fixing bright finished brass 100mm mortice latch and lock with minimum (4Levers to 6Levers) and a pair of lever handles of approved quality with necessary screws, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35Kgs and door width upto 700mm), with necessary accessories and screws, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing aluminium sliding door bolts(aldrop) of [250 x 16]mm, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing 20mm dia chromium plated brass curtain rod / Towel rail of 1800mm long having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing M.S. grills with M.S. flats, square or round bars to openings of required pattern / frames of windows with rawl plugs screws, etc., including priming coat with approved steel primer and paint finish, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing Fire resistant door frame of section [143 x 57]mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120gm/Sq m) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size [10 x 4]mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc and including necessary accessories, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing 50mm thick glazed Fire resistant door shutters with view panel of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100mm wide, bottom rail 200mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120gm/m2) duly filled FR insulation material and fixing with all necessary fittings along with stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing stainless steel fancy handle of 200mm to fire rated doors of approved make fixed with SS screws, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing non load bearing fixed frame (Door frame) for fire resistant glazed Partition for 120 minutes Fire Rating, made out to a profile of dimension [60 x 70]mm of 1.60mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 minutes of both integrity & radiation control (EW120) & minimum 20 minutes of insulation (EI20).The profile has to be fixed to the supporting construction by means of anchor fasteners of size M10 x 80, every 150 mm from the edges and every 500mm (approx) c/c. Linear measurement of frame shall be measured for payment. The frame shall be filled with mineral wool insulation of density min 96kg/m³. and finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per NBC 2016, IS 16231 (Part 3):2016, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing 60mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999,tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail [60 x 60]mm wide and bottom rail of [110 x 60]mm made out of 1.60mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96kg/m³ and fixing with necessary stainless steel ball bearing hinges of size [100 x 89 x 3]mm of approved make, including glazing, applying a coat of approved fire resistant primer or powder coating not less than 30 micron, etc., all complete as per direction of Engineer-in-Charge.
Supply an dfixing Fly proof stainless steel grade 304 wire gauge with 0.50mm dia. wire and 1.4mm wide aperture inside the aluminum doors, window shutters, ventilators with required beading, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing factory made UPVC glazed / white Casement window double panels of height upto 1.80m with fixed mullion with SS 304 friction hinges as per size and weight of sash, with multi point locking sysem, zinc alloy (zamak) powder coated handles, using R3 series with frame size of 55mm & above X 45mm & above & sash size of 55mm & above X 65mm & mullion size of 55mm & above X 65mm, cross sections of uPVC profiles, etc., all complete as per approved drawing & direction of Engineer-in-Charge. Note:- Glazing shall be paid separately.
Providing and fixing mild steel round foundation / holding down bolts with nuts and washer plates, Brackets inside Hangar M.S.Bolts -20mm dia, Machine foundatiosn M.S.Bolts -20mm dia, etc., all complete as per direction of Engineer-in-Charge.
Supplying, fabricating, hoisting and fixing in position M.S. structual steel work E 250 (Fe 410W) in Roof trusses, purlins, girders, stanchions, crane gantries, rails / sliding frames, edging angles, frames, fastenings, machine foundations, galvanised steel deck sheet confirming to IS: 277:1992 as permanent shuttering supported over structural steel like Beams, columns, joists, etc., with shear studs, etc., as per site requirement, etc., using standard steel rolled sections, including M.S. plates, cutting to dead length where required, notching, drilling, riveting and / or welding, connecting with bolts and nuts, wedging, plumbing, truing up and painting the members with two coats of synthetic enamel paint over a coat of approved zinc chromate primer, preparation of surface, etc., all complete as directed by the Engineer-in-Charge.
Steel work welded in built up sections / framed work, In stringers, treads, landings, etc., of stair cases, use of chequered plate wherever required, edge frames / angles for false ceiling, foundation edges, pedestal, frames for AC ducts, compressor lines, base plates,guard bar, ladder, Cable trenches, M.S.railings, brackets, gates and similar works including cutting, hoisting, fixing in positionwith required foundation an danchor bolts and applying a priming coat of approved steel primer using structural steel, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates, etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts, etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in Charge, (for payment purpose only weight of stainless steel members shall be considered.
Providing and fixing angle iron frames for doors, windows, ventilators, foundations of mild steel Angle sections of Minimum size [35 x 35 x 5]mm upto [75 x 75 x 5]mm joints mitred and welded by angle iron of minimum [35 x 35 x 5]mm or [35 x 5]mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, etc., all complete as per the direction of Engineer-in-Charge.
Providing and fixing factory made ISI marked steel / metal glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B, etc., complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, fixing with [15 x 3]mm lugs 10cm long embedded in cementconcrete block [15 x 10 x 10]cm of C.C. 1:3:6 including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, etc., all complete as directed by Engineer-in-Charge and as per approved design by HAL.
Providing and laying Glazed Vitrified floor tiles / Matt / Antiskid finish of Size [600 X 600]mm or standard availabe size with Joint in different sizes (Thickness to be sepcified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.30Kg/Sq m including grouting the joints with white cement and matching pigments, etc., all, complete as per instructions of Engineer-in-Charge.
Providing and laying Vitrified tiles using various sized tiles approximately [600 x 600]mm Matt / Antiskid finish (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, cladding / dadoo over 12mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/Sq m including grouting the joint with white cement & matching pigments, etc., all complete as per direction of Engineer-in-Charge.
Providing and laying Polished Granite stone flooring and staircase raiser / partitions / divider and steps in colour Black, Cherry / Ruby Red or Equivalent in required design and patterns, in linear as well as curvilinier portions of building as complete as per the architectural drawings / Site condition with 18mm thick stone slab on 20mm (average) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand) laid and jointed with cement slurry and pointed with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing, nosing, chamfering and making grooves, etc., all complete as per direction of Engineer-in-Charge.
Providing and laying flamed finish Granite stone of Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent colour for flooring, ramps in required design and patterns, for ramps, flooring and steps including treads & risers in linear as well as curvilinear portions of the building, etc., all complete as per the architectural drawings with 18mm thick stone slab over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing, round nosing, etc., all complete as specified and as directed by the Engineer-in-Charge.
Providing and fixing Single socketed pipes of 110mm diameter unplasticised Rigid PVC water pipes conforming to IS : 13592 Type A of approved brand, on wall / floor including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, etc., all complete as per direction of Engineer-in-Charge.
Plastering to internal brick / block wall with 15mm thick on the rough side of single or half brick wall of cemnet mortor (1:6) including leveling, curing and making the level smooth and at all heights, plaster drip course / groove in plastered surface or moulding to R.C.C. projections and execute the work, etc., all complete as per direction of Engineer-in-Charge.
Plastering to ceiling with 12mm thick on the rough side with cement mortor (1:4) including leveling, curing and making the level smooth and at all heights and execute the work, etc., all complete as per direction of Engineer-in-Charge.
Plastering to external brick / block wall with 18mm cement plaster in two coats under layer 12mm thick cement plaster on the rough side with cement mortor 1:5 (1 cement : 5 coarse sand) finished with a top layer 6mm thick cement plaster 1:6 (1 cement : 6 fine sand) including leveling, curing and making the level smooth and at all heights, plaster drip course / groove in plastered surface or moulding to R.C.C. projections and the work to be completed as per direction of Engineer-in-Charge.
Providing and applying internal wall and ceiling painting with two coats of premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50grams/litre after applying white cement based putty of average thickness 1mm over the plastered wall surface including preparation of the surfces, with a coat of low VOC primer with emery paper to bring to smooth and even including applying additional coats wherever required to achieve even shade and colour of approved brand, etc., all complete as directed by the Engineer-in-Charge.
Providing and Finishing walls with Acrylic Smooth exterior paint of required shade for New work (Two or more coat applied @ 1.67 ltr/10Sq m over and including priming coat of exterior primer applied @ 2.20 kg/10Sq m) including scrapping, preparationof surface, etc., all complete as directed by the Engineer-in-Charge.
Providing and applying synthetic enamel paint for walls, pipes, grills, chequered plate, shutters, joineries, etc., in Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture, filling joints, metal patti, etc., all complete as per the direction of Engineer-in-Charge.
Dismantling approximate 15 to 40mm dia G.I. / CI / UPVC / CPVC pipes including stacking of dismantled pipes (within 50 metres lead) including making temporary arrangements for continuing ongoing services to toilets / division maintenance, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing bright finished brass hard drawn hooks (coat hooks) and eyes of 300mm size, etc., all complete as directed by the Engineer-in-Charge.
Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/Sq m by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints, etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM,D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane. Note: A performance guarantee bond for 10 years for leak proof roofing shall be given by the contractor on non-judicial stamp paper of Rs.500/-. The 10% of completed value of this item shall be dedcuted as defect liability deposit and the same shall be returned after sucessful completion of 10 years from the date of completion of contract / project as a whole.
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation, etc., all complete as directed by the Engineer-in-Charge.
Demolishing R.C.C. work in all layers and heights by manually / by mechanical means including handing over of usefull steel bars to the user department and disposal of unserviceable material outside HAL upto distance of 10km including loading, cleaning and unloading at designated area as per local authority procedures, etc., all complete as directed by the Engineer-in-Charge.
Demolishing brick work in all layer and heights by manually / by mechanical means built in cement mortar including stacking of serviceable material / handing over to user department and disposal of unserviceable material outside HAL upto distance of 10km including loading, cleaning and unloading at designated area as per local authority procedures, etc., all complete as directed by the Engineer-in-Charge.
Demolishing stone rubble masonry / kerb stones in all layer and heights by manually / by mechanical means from cement mortars including stacking of serviceable material / handing over to user department and disposal of unserviceable material outside HAL upto distance of 10km including loading, cleaning and unloading at designated area as per local authority procedures, etc., all complete as directed by the Engineer-in-Charge.
Dismantling of flexible pavement (only bituminous courses upto a depth of 1500mm) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, etc., all complete as directed by the Engineer-in-Charge.
Dismantling precast concrete or stone slabs laid over walls, drain walls / kerbs of thickness above 40mm upto 75mm etc. including stacking within 50metres lead above 40mm thickness, etc., all complete as directed by the Engineer-in-Charge.
Taking out C.I. cover with frame from R.C.C. top slab of inspection Chambers / Manholes of various sizes including demolishing of R.C.C. work / Brick Work eigther manually / by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50metres lead, etc., all complete as directed by the Engineer-in-Charge.
Dismantling of spindle of fire hydrant head / Yard Line Post including stacking of useful materials within 50metres lead and non useful material outside the premises, within 50 metres lead, etc., all complete as directed by the Engineer-in-Charge.
Preparation and consolidation of sub grade with power road roller of 8 to 12Tonne capacity after excavating earth to an average of 22.50cm depth, dressing to camber and consolidating with road roller including making good the undulations, etc., and re-rolling the subgrade and disposal of surplus earthwith lead upto 50 metres, etc., all complete as directed by the Engineer-in-Charge.
Construction of granular sub-base (GSB) with material conforming to Grade-II (size range 53mm to 0.075mm) having CBR Value-25 by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, etc., all complete as per specifications and directions of Engineer-in-Charge.
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/Cu m, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing, etc., all complete as per direction of Engineer-in-Charge.
Providing and laying design mix cement concrete of M-30 grade (Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transitmixer), in roads / taxi tracks / runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40mm down size nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve / tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope / camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction / expansion, construction & longitudinal joints (10mm wide x 50mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, etc., complete all as per direction of Engineer-in-Charge (Item of joint fillers, sealants, dowel bars withsleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/Cu m. Excess / less cement used as per design mix is payable / recoverable separately.
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, etc., all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
Providing and filling in position rubberized bitumen hot sealing compound for sealing of construction / expansion joints using grade 'A' sealing compound conforming to IS: 1834. in roads / pavements, etc., all complete as per direction of the Engineer-in-Charge.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid in panels if required and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush, etc., complete as per specifications and directions of Engineer-in Charge. (Note:- Cement content considered in this item is @ 330 kg/Cu m. Excess / less cement used as per design mix is payable / recoverable separately).
Providing and fixing glass shelf of size [600 x 120 x 5]mm with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40mm long screws, rawl plugs, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing C.P. brass toilet paper holder of approved brand and fixing with screws, raw plugs, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing beveled edge mirror of size [600 x 450]mm of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing Wall hung half pedestal Vitreous China Wash basin size of approximate size [630 x 450]mm fixed with with C.I. brackets / rack bolts , single 15mm C.P. brass pillar taps, 32mm C.P. brass waste coupling of standard pattern, P.V.C. waste pipe with waste fittings of 40mm dia and make it function of approved brand / make, including painting of fittings and brackets, cutting and making good the walls wherever required, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) of approved brand with ISI marked white solid plastic seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all connecting fittings and fixtures to make it operational completely, including cutting and making good to the walls and floors wherever required, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing 8mm dia C.P. / S.S. Jet (Health Fuacet) with flexible tube upto 1 metre long with S.S. triangular plate on walls / Eureopean type W.C. material of approved make and quality, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing white colour wall hung vitreous china battery based infrared sensor operated urinal of approximate size [610 x 390 x 370]mm having pre & post flushing with water (250 ml & 500 ml consumption approx.), having water inlet from back side, including fixing to wall with brackets embedded in cement mortar (1:3), connecting the waste pipe / waste coupling to floor trap with all necessary fittings and accessories like 32mm dia semi-rigid PVC waste pipe (concealed in the wall) including PVC waste fittings, clamps, etc., all complete as per manufacturers specification and direction of Engineer-in-Charge.
Providing, fixing, testing and commissioning trap ( floor trap ) of approved make with 100mm inlet and 75mm outlet of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors, connection with PVC soil / waste pipe, necessary 150mm thick cement concrete (1:2:4) for embedding the trap, etc., all complete as directed by the Engineer-in-Charge.
Constructing masonry Chamber [120 x 120 x 100]cm inside, in brick work of 7.5 class designated in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement, etc., all complete as per standard design and complete as per the direction of Engineer-in-Charge.
Constructing masonry Chamber [60 x 60 x 75]cm inside or outside (or approximate size as per site condition) , in brick work of class designation 7.5. in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design, etc., all complete as per direction of Engineer-in-Charge.
Providing and fixing 15mm nominal bore dia C.P. brass bib cock of approved quality conforming to IS:8931, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing Concealed Chlorinated Polyvinyl Chloride (CPVC) pipes of approved brand, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, fixing the pipe with clamps at 1m spacing, necessary reducers, tank adaptors, etc., This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints and making good the walls, etc., all complete as per direction of Engineer in Charge.
15mm dia
20mm dia
25mm dia
32mm dia
Providing and fixing Extrenal exposed Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints, etc., all complete as per direction of Engineer-in-Charge.
32mm nominal dia
40mm nominal dia
50mm nominal dia
65mm nominal dia
80mm nominal dia
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms (or nearest availabe size and weight), etc., all complete as directed by the Engineer-in-Charge.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank of 2000 litres capacity, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes for tank and make operational for supply of water to all floors, etc., all complete as directed by the Engineer-in-Charge.
Providing and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 of approx 150mm dia conforming to IS : 8329, etc., all complete as per the directions of Engineer-in-Charge.
Providing and laying flanged C.I. standard specials of dia upto 300mm such as tees, bends, collars, tapers, caps, reducers,tail pieces etc., suitable for flanged jointing as per IS : 1538, etc., all complete as per the directions of Engineer-in-Charge.
Providing and laying manually or mechanical means Non pressure NP-3 class (Medium duty) R.C.C pipes including collars / spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1Cement :2 Finesand) inlcuding testing of joints and completing the work, etc., all complete as directed by the Engineer-in-Charge.
450mm dia RCC pipe
600mm dia RCC pipe
Dismantling of old S.W. pipes upto 200mm dia including breaking of joints and bed concrete stacking of useful materials near the site within 50m lead and disposal of unserviceable materials into municipal dumps, etc., all complete as directed by the Engineer-in-Charge.
Providing and laying non-pressure NP2 class (light duty) R.C.C pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints for cable trenches, rain water lines, sanitray lines, etc., all complete as directed by the Engineer-in-Charge.
150mm dia
300mm dia
450mm dia
Constructing brick masonry manhole in cement mortar 1:4 (1cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4coarse sand (zone-III) : 8 graded stone aggregate 40mm nominalsize), inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement andmaking channels in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20mm nominal size) finished witha floating coat of neat cement as per standard design, etc., all complete as directed by the Engineer-in-Charge.
Inside size [90 x 80]cm and 45cm deep including Built In Sewer Brick C.I. cover with frame (light duty) [455 x 610]mm internal dimensions, total weight of cover and frame to be not less than 38Kgs (weight of cover 23Kgs and weight of frame 15Kgs), etc., all complete as directed by the Engineer-in-Charge.
Extra for each one meter depth based on site condition over the standard depth of 45cm for the items under manhole of size [90 x 80]cm with Sewer Brick Confirming to IS: 4885, etc., all complete as directed by the Engineer-in-Charge.
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of 450mm dia of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap, etc., by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap), etc., all complete as directed by the Engineer-in-Charge. Note: Truck Mounted rotary / TMR / Tubewell boring machine shall not be used.
Providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators, and partitions for fixing and shutters with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, hinges / pivoting, filling up the gaps at junctions, with dash fasteners and EPDM rubber / neoprene gasket, accessories to operating the doors, windows, ventilators, etc., all complete as per architectural drawings or as per site and the directions of Engineer-in-Charge. (Glazing, paneling to be paid for separately) Note: Shop drawing to be submitted & approval to be obtained from Engineer-in-charge before order is placed.
Providing and fixing glazing in aluminium door, window, ventilator, louvers, shutters and partitions, etc., With float glass panes of 5mm thickness (weight not less than 12.50 kg/Sq m) along with EPDM rubber / neoprene gasket, etc., all complete as per the architectural drawings and the directions of Engineer-in-Charge.
Providing and fixing toughened glass panes of 12mm thickness glazing in aluminium door, window, ventilator, shutters and partitions along with EPDM rubber / neoprene gasket, etc., all complete as per the architectural drawings and the directions of Engineer-in-Charge. Note: Shop drawing to be submitted & approval to be obtained from Engineer-in-Charge before order is placed and MTC's to be submitted.
Providing and fixing double glazed hermetically sealed glazing in windows, ventilators and partition, etc., with 6mm thick clear float glass both side, having 12mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant), etc., all complete as per specifications, and direction of Engineer-in-Charge. Note: Shop drawing to be submitted & approval to be obtained from Engineer-in-Charge before order is placed and MTC's to be submitted.
WATER PROOFING: Providing and laying integral cement based water proofing treatment with average thickness of 120mm and minimum thickness as 65mm, including preparation of surface as required for treatment of roofs, balconies, terraces, etc., consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75Kgs/Sq m of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-Charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge over 20mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-Charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of junctions of walls and slabs.
Providing and fixing mineral fibre false ceiling tiles at all heights of size [595 X 595]mm of approved texture, design and pattern with 16mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6). The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33mm thick (galvanized @ 120 gsm) comprising of main T runners of [15 x 32]mm of length 3000mm, cross T of size [15 x 32]mm of length 1200mm and secondary intermediate cross T of size [15 x 32]mm of length 600mm to form grid module of size [600 x 600]mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50mm long 8mm outer diameter M-6 dash fasteners, 6mm diameter fully threaded hanger rod up to 1000mm length and L-shape level adjuster of size [85 x 25 x 2]mm, spaced at 1200mm centre to centre along main ‘T’. The system should rest on periphery walls / partitions with the help of GI perimeter wall angle of size [24 x 24 X 3000]mm made of 0.40mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-Charge.
Providing and laying factory made Precast concrete solid blocks of 200mm thickness of grade M10 made of Normal resources / C&D waste from approved manufacturer in foundation and plinth with Cement mortar (1:6) in true line and height including curing, cleaning, etc., all complete as per the direction of Engineer-in-Charge.
Providing and laying factory made Precast concrete solid blocks of 200mm thickness of grade M10 made of Normal resurces / C&D waste from approved manufacturer in superstructure above plinth level up to +20m height with Cement mortar (1:6) including required stagging, each course in true level & racking out joints, curing and cleaning, etc., all complete as per the direction of Engineer-in-Charge.
Providing and laying half block masonry with factory made Precast concrete solid blocks of 100mm thickness of grade M10 made of Normal resources / C&D waste from approved manufacturer in foundation and plinth with Cement mortar (1:4) in true line and height including curing, cleaning, etc., all complete as directed by the Engineer-in-Charge.
Providing and laying half block masonry with factory made Precast concrete solid blocks of 100mm thickness of grade M10 made of Normal / C&D waste from approved manufacturer in superstructure above plinth level up to +10m height with Cement mortar (1:4) including required stagging,each course in true level & racking out joints,curing and cleaning, etc., all complete as directed by the Engineer-in-Charge.
Supplying, fabricating, fixing and commissioning in position Industrial sliding door / Puffed sheet sliding door of approximate opening size of various sizes like [3 X 4]m, [5 x 5]m or [36 X 10]m with motorisation and option for manual operation. The sliding door frame to be fixed with puffed sheet covered on oneside with plain surface and other side with not less than 0.50mm thick sheet, etc., with view window of size not less than [500 x 500]mm. The sliding door to be completed with all fittings and fixtures, locking facility, suitable motorisation, guiding sections, rollers, bearings, cross bracings, vertical supports, etc., all complete and including painting with two coats of synthetic enamel paint over a coat of approved red oxide primer, preparation of surface, etc., all complete as directed by Engineer-in-Charge. [Shop drawings to be provided by the agency and to be approved by EIC before execution]. TECHNICAL SPECIFICATIONS 1. Shutters: Modular door shutters designed to withstand wind load and all types of impact load as per IS 875 (Part-3) & IS 800 (LSW). 2. Roller wheels: Each shutter shall be supported at the top and bottom on 2 heavy duty roller wheels of size specially designed to run on top / bottom track. The wheels shall be of EN-9 grade steel as per IS 3177 with shafts & supporting bracket plates. The wheels are of double flanged type and will be in single piece without any tyre. Each wheel shall have two nos of antifriction self lubricating maintenance free ball bearings. 3. EPDM / Neoprene rubber gasket shall be applied in between horizontal & vertical gaps of door leafs and at the centre to make door airtight and dust free. 4. Cleats: Cleats made of MS section shall be fixed on top guide to protect door leafs from falling down in case top wheel fails.
Supply & Apply of 4mm Solvent Free, Self Levelling Epoxy Flooring Surface preparation: - Providing and cleaning all floor surface including wall up to required height to make it free from dirt, dust, loose particles, wax, polish, efflorescence, laitance, curing compound and other contaminants by using wire brush, grinding all sharp edges to make it flush with the surface, etc., and complete as per manufacturer's specification Priming :- Providing and applying of Apcoflor HFP 120 / 130, Two component, high solid, epoxy resin based floor primer of 10 Kg Pack size using a brush or short / medium pile roller to achieve thickness of 100microns with consumption of 0.15kg/Sq m by mixing Base : Hardener in ratio of 65 : 35 Screed :- Providing and applying of Apcoflor LSC 3 XL, Three component, epoxybased, high strength, self levelling screed of 15 Kg Pack size upon the applied primer to achieve thickness of 2mm with consumption of 5.82Kg/Sq m by mixing Base : Hardener : Aggregates in ratio of 20 : 10 : 70 Compressive Strength (ASTM C 579) 41 MPA,Flexural Strength (ASTM C 580) 10 MPA Tensile Strength (ASTM C 307) 8 MPA,Pull off Adhesion (ASTM D 4541) >1.5 MPA (Concrete Failure) Top Coat:- Providing and applying of Apcoflor SL 2, Three component solventfree, self levelling epoxy Top Coat, which is hard wearing & chemical resistant, Confirming to Global Migration Standards laid down in US-FDA: 21CFR 175-300, of 10 Kg Pack size upon the applied screed to achieve a thickness of 2mm with consumption of 3.2Kg/Sq m by mixing Base : Hardener : Aggregates in ratio of 34 : 14 : 52 Compressive Strength (ASTM C 579) 51 MPA Flexural Strength (ASTM C 580) 12 MPA Tensile Strength (ASTM C 307) 8 MPA Make :- Asian Paints, BASF, FOSROC or equivalent.
Supply and fixing Bulletproof glass window with each glass of minimum 25mm upto 40mm thick on either side with a suitable structural frame system, filling items if any to be embeded between frames before casting / fixing between concrete / masonary walls with all necessary accessories in full and final. The work to be completed all as directed by Engineer-in-Charge at all levels. Note: 1. Shop drawing to be submitted & approval to be obtained from Engineer Incharge before order is placed and MTC's to be submitted. 2.Quoted rate should be inclusive of all consumables no extra payment will be made for any items
Supplying and fixing Motorized G.I. rolling shutter of approved make and made of required size. The curtain shall be constructed from Tata Bluescope/JSW 150 gsm single skinned galvalume steel laths with natural finish of minimum 1.25mm thickness and interlocking distance of minimum 75mm. Side guides shall be made of min. 2 or 3.15mm thick heavy duty TG Galvanised steel, as per the site requirement, along with necessary fixtures like cleats (spacing shall not exceed 0.75m) or supports brackets for attachments to the walls or column by screws or bolts and necessary seals.The size of the guide channels shall be conforming to Is:6248-1979. Single piece G.I. Heavy duty mild steel suspension shaft along with roller of sufficient diameter with springs shall be provided along with necessary hexagonal bracket plate of min 3.15mm thickness, size conforming to Is:6248-1979 and square bar, if necessary. The provision of Pressed galvalume steel hood cover with reinforced bracket as required to suit the shutter width and motor cover with natural finish of min. 0.90mm thick and of reuired shape along with necessary fixtures and stiffeners like angle cleats, angle or flat stiffeners,etc shall be provided. Bottom profile shall be of G.I. plate with angle stiffner. The bottom rail shall be fixed with extruded rubber bottom seal that shall seal against the floor when the door is fully closed. The CE Certified CRS Compact Gear motorised system shall be indirect drive type along with system power supply wired with industrial plug and three station push button/ switch with deadman control and arrangements for inside and outside locking.
Approximate size of shutter [3 X 4]m
Approximate size of shutter [5m X 5]m
Supplying and fixing in position factory insulated sandwich panel for Roofing / cladding minimum 80mm thick with facings made up of pre-painted galvalume, not less than 0.50mm thick (TCT) on top and 0.50mm thick on the bottom with 550 Mpa yield strength. The core material shall be made up of rigid polyisosyrene foam (PIF) conforming to IS 12436 and of density around 40 ± 2 kg/m³ fixed with self tapping screws incuding necessary supplementary fittings, butyl tape, joint fillers, joint laps, making provision for accessories, necessary cutouts/openings, supports for joinery as required, etc., along with the PUF end caps and all exposed surfaces are protected with masking 80mm Thk core PIR and 120mm Thk overall thickness include crest, all complete as per manufacturer's specification and as directed by the Engineer-in-Charge. Note: (i) Refer detailed technical specifications. (ii) The quoted rate shall be inclusive of overlaps and wastages. (iii) A performance guarantee bond for 10 years for leak proof roofing shall be given by the contractor on non-judicial stamp paper of Rs.500/-. The 10% of completed value of this item shall be dedcuted as defect liability deposit and the same shall be returned after sucessful completion of 10 years from the date of completion of contract / project as a whole.
"Providing and fixing Heradesign Superfine, Screw mounted using CD channels & Universal Bracket, (NRC 0.90 or as per ASTM C423) for sound proofing, 1 layer magnesite bonded wood wool acoustic panel in walls and ceilings, 1mm thick fibre, exquisite surface structure, building biology recommended of approximate size [1200 x 600 x 25]mm, having edge detail AK-01 (5mm bevel on all 4 sides), weight 11.30 Kg/Sq m, fire protection class B-s1, d0 as per EN 13501-1 & Humidity Resistance of 95%. Thickness Tolerance T2 (± 1 mm) according to EN 13168 along,ball impacted resistance acoording to DIN 18032 / part-3 or class 1A according to EN 13964 annex D-with all necessary accessories like Anchor fastners, Wall screws of required dia, etc., Wood wool panels to be PEFC certified & should bear the Forest Stewardship Council Seal confirming that the wood used originates from responsibly managed forests, including Spray painting / painting with non reflective coated paint Heradesign wood wool boards as specified.The wood wool board should be backed by 40mm thick glass wool slab packed in size [1200 X 600]mm having as gross density of 50Kg/m3, making it fully operational and testing at site for required NRC value, etc., all complete as directed by the Engineer-in-Charge.
Rupees Ninety Crore Thirty Seven Lakh Thirty Two Thousand Eight Hundred Fifty Three and Twenty Seven Paise Only
Supply, Installation, Testing & commissioning of GTC hangar 1, Main LT Panel (TTA panel) (IEC 61439 Standards)
Incomer
1No - 3200A, 415V gr. 50KA, 4P EDO Type ACB
Lot - 4000A TP + N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of power logic PM2230 of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set of - 3200/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings
1 No - 1250A 415V gr. 50KA TP+NL MDO type ACB
1 No - 800A 415V gr. 50KA TP+NL MDO type ACB
1 No - 630A 415V gr. 50KA TP+NL MDO type ACB
1 set - 400A 415V gr. 50KA TP+NL MCCB including 400/5A CT and MFM/MDM of EM6400NG or equivalent
3 sets - 400A 415V gr. 36KA TP+NL MCCB including 400/5A CT and MFM/MDM of EM6400NG or equivalent
3 Nos - 125A 415V gr. 36KA TP+NL MCCB
2 Nos - 100A 415V gr. 36KA TP+NL MCCB
1 Nos - 63A 415V gr. 25KA TPN MCCB
2 Nos - 63A 415V gr. 10KA TPN MCB
1 No - 40A 240V gr. 10KA DP MCB
5 Nos - 32A 415V gr. 10KA TPN MCB
Supply, Installation, Testing & commissioning of GTC hangar 1, LT Panel no 2 (TTA panel) (IEC 61439 Standards)
Incomer
1No - 1250A, 415V gr. 50KA, 4P EDO Type ACB
Lot - 1500A TP + N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of power logic PM2230 of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set of - 1250/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings
3 sets - 400A 415V gr. 36KA TP+NL MCCB including 400/5A CT and MFM/MDM of EM6400NG or equivalent
1 No - 250A 415V gr. 36KA TP+NL MCCB.
2 Nos - 160A 415V gr. 36KA TP+NL MCCB.
1 No - 125A 415V gr. 36KA TP+NL MCCB.
2 Nos - 100A 415V gr. 36KA TP+NL MCCB.
4 Nos - 63A 415V gr. 10KA TPN MCB.
1 No - 40A 415V gr. 10KA TPN MCB.
5 Nos - 32A 415V gr. 10KA TPN MCB.
1 No - 40A 240V gr. 10KA DP MCB.
Supply, Installation, Testing & commissioning of GTC hangar 2, Main LT Panel (TTA panel) (IEC 61439 Standards)
Incomer
1No - 3200A, 415V gr. 50KA, 4P EDO Type ACB
Lot - 4000A TP + N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of power logic PM2230 of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set of - 3200/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings
1 No - 1600A 415V gr. 50KA TP+NL MDO type ACB
1 No - 1250A 415V gr. 50KA TP+NL MDO type ACB
1 No - 630A 415V gr. 50KA TP+NL MDO type ACB
1 No - 400A 415V gr. 50KA TP+NL MCCB
1 No - 200A 415V gr. 36KA TP+NL MCCB
1 No - 160A 415V gr. 36KA TP+NL MCCB
2 Nos - 125A 415V gr. 36KA TP+NL MCCB
1 No - 100A 415V gr. 36KA TP+NL MCCB
1 No - 63A 415V gr. 25KA TPN MCCB
6 Nos - 32A 415V gr. 10KA TPN MCB
1 No - 32A 240V gr. 10KA DP MCB
Supply, Installation, Testing & commissioning of GTC hangar 2, Power pack LT Panel (TTA panel) (IEC 61439 Standards)
Incomer
1No - 1250A, 415V gr. 50KA, 4P EDO Type ACB
Lot - 1500A TP + N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of power logic PM2230 of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set of - 1250/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings
1 No - 250A 415V gr. 36KA TP+NL MCCB.
2 Nos - 125A 415V gr. 36KA TP+NL MCCB.
12 Nos - 100A 415V gr. 36KA TP+NL MCCB.
1 No - 63A 415V gr. 10KA TPN MCB.
4 Nos - 32A 415V gr. 10KA TPN MCB.
Supply, Installation, Testing & commissioning of Transmission Hangar 1 LT Panel (TTA panel) (IEC 61439 Standards)
Incomer
1No - 2000A, 415V gr. 50KA, 4P EDO Type ACB
Lot - 2500A TP + N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No - Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of power logic PM2230 of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set of - 2000/5A current transformers of class 1 and 15VA burden for metering.
1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings
1 No - 1250 A 415V gr. 50KA, TP+NL MDO Type ACB
1 No - 400 A 415V gr. 36KA, TP+NL MCCB
2 Nos - 250A 415V gr. 36KA TP+NL MCCB
1 No - 160A 415V gr. 36KA TP+NL MCCB
2Nos - 125A, 415V gr. 36KA, TP+NL MCCB
2Nos - 100A, 415V gr. 36KA, TP+NL MCCB
5Nos - 80A, 415V gr. 36KA, TP+NL MCCB
2Nos - 63A, 415V gr. 10KA, TPN MCB
7Nos - 32A, 415V gr. 10KA, TPN MCB
Supply, Installation, Testing & commissioning of Transmission Hangar 2 LT Panel (TTA panel) (IEC 61439 Standards)
Incomer
1No - 1250A, 415V gr. 50KA, 4P EDO Type ACB
Lot - 1500A TP + N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of power logic PM2230 of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set of - 1250/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings
2 sets - 400A 415V gr. 36KA TP+NL MCCB including 400/5A CT and MFM/MDM of EM6400NG or equivalent
1 No - 250A 415V gr. 36KA TP+NL MCCB
1 No - 200A 415V gr. 36KA TP+NL MCCB
1 No - 125A 415V gr. 36KA TP+NL MCCB
1 No - 63A 415V gr. 25KA TP+NL MCCB
2 Nos - 63A 415V gr. 10KA TPN MCB
6 Nos - 32A 415V gr. 10KA TPN MCB
Supply, Installation, Testing & commissioning of Transmission Hangar 3 LT Panel (TTA panel) (IEC 61439 Standards)
Incomer
1No - 3200A, 415V gr. 50KA, 4P EDO Type ACB
Lot - 4000A TP + N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of power logic PM2230 of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set of - 3200/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings
2 Nos - 1600A 415V gr. 50KA TP+NL MDO type ACB including 1600/5A CT and MFM/MDM of EM6400NG or equivalent
1 No - 400A 415V gr. 36KA TP+NL MCCB including 400/5A CT and MFM/MDM of EM6400NG or equivalent
3 Nos - 320A 415V gr. 36KA TP+NL MCCB including 320/5A CT and MFM/MDM of EM6400NG or equivalent
1 No - 125A 415V gr. 36KA TP+NL MCCB
3 Nos - 100A 415V gr. 36KA TP+NL MCCB
1 No - 63A 415V gr. 25KA TP+NL MCCB
1 No - 63A 415V gr. 10KA TPN MCB
5 Nos - 32A 415V gr. 10KA TPN MCB
Supply, Installation, Testing & commissioning of GTC hangar 1, Power pack LT Panel-1 (PTTA panel) (IEC 60439 Standards)
Incomer
1No - 800A, 415V gr. 50KA, 4P EDO Type ACB
Lot - 1000A TP + 500A N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of power logic PM2230 of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set of - 800/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings
1 No - 400A 415V gr. 36KA TP+NL MCCB including 400/5A CT and MFM/MDM of EM6400NG or equivalent
2 Nos - 160A 415V gr. 36KA TP+NL MCCB
1 No - 125A 415V gr. 36KA TP+NL MCCB
1 No - 100A 415V gr. 36KA TP+NL MCCB
3 Nos - 63A 415V gr. 10KA TPN MCB
2 Nos - 40A 240V gr. 10KA DP MCB
5 Nos - 32A 415V gr. 10KA TPN MCB
Supply, Installation, Testing & commissioning of GTC hangar 1, LT Panel-3 (PTTA panel) (IEC 60439 Standards)
Incomer
1No - 400A, 415V gr. 50KA, Four Pole MCCB MP based
Lot - 500A TP + 250 N, 415V, short circuit rated 50KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set of - 400/5A current transformers of class 1 and 15VA burden for metering.
1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings
3 Nos - 100A 415V gr. 36KA TP+NL MCCB
4 Nos - 63A 415V gr. 10KA MCB
5 Nos - 32A 415V gr. 10KA MCB
2 Nos - 40A 240V gr. 10KA DP MCB
Supply, Installation, Testing & commissioning of GTC hangar 1, Test bench/Rig LT Panel (PTTA panel) (IEC 60439 Standards)
Incoming
1No - 630A, 415V gr. 50KA, 4P EDO Type ACB
Lot-800A, 3Phase and 400A neutral 415V, short circuit rated 50KA for 1sec, TPN Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set-630/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A, 230V,10KA, SP MCB.
1Set- 6A, 230V, 10KA SP MCB for the protection of measuring instruments.
Outgoings:
1No - 160A, 415V gr. 36KA breaking capacity, TP+NL MCCB
3Nos - 125A, 415V gr. 36KA breaking capacity, TP+NL MCCB
3Nos - 100A, 415V gr. 36KA breaking capacity, TP+NL MCCB
1No - 63A, 415V gr. 10KA breaking capacity, TPN MCB
2Nos - 32A, 415V gr. 10KA breaking capacity, TPN MCB
Supply, Installation, Testing & commissioning of GTC hangar 1, UPS output Panel 1 (PTTA panel) (IEC 60439 Standards)
Incoming
2Nos - 200A, 415V gr. 36KA, 4P MCCB TM based.
1No - 200A, Four Pole, Automatic transfer switch with controller
Lot-250A, 3Phase and 150A neutral 415V, short circuit rated 36KA for 1sec, TPN Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set-200/5A current transformers of suitable class and VA burden for metering.
1No 13A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A, 230V,10KA, SP MCB.
1Set- 6A, 230V, 10KA SP MCB for the protection of measuring instruments.
Outgoings:
3Nos - 63A, 415V gr. 10KA breaking capacity, TPN MCB
3Nos - 63A, 415V gr. 10KA breaking capacity, DP MCB
1No - 40A, 415V gr. 10KA breaking capacity, DP MCB
Supply, Installation, Testing & commissioning of GTC hangar 1, UPS output Panel 2 (PTTA panel) (IEC 60439 Standards)
Incoming
2Nos - 125A, 415V gr. 36KA, 4P MCCB
1No - 125A, Four Pole, Automatic transfer switch with controller
Lot-150A, 3Phase and 100A neutral 415V, short circuit rated 36KA for 1sec, TPN Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set-125/5A current transformers of suitable class and VA burden for metering.
1No 13A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A, 230V,10KA, SP MCB.
1Set- 6A, 230V, 10KA SP MCB for the protection of measuring instruments.
Outgoings:
1No - 63A, 415V gr. 10KA breaking capacity, TPN MCB
3Nos - 63A, 415V gr. 10KA breaking capacity, DP MCB
2Nos - 40A, 415V gr. 10KA breaking capacity, DP MCB
Supply, Installation, Testing & commissioning of GTC hangar 2, Sub LT panel (PTTA panel) (IEC 60439 Standards)
Incoming
1No - 630A, 415V gr. 50KA, 4P EDO Type ACB
Lot-800A, 3Phase and 400A neutral 415V, short circuit rated 50KA for 1sec, TPN Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set-630/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A, 230V,10KA, SP MCB.
1Set- 6A, 230V, 10KA SP MCB for the protection of measuring instruments.
Outgoings:
1No - 250A, 415V gr. 36KA breaking capacity, TP+NL MCCB
7Nos - 63A, 415V gr. 10KA breaking capacity, TPN MCB
9Nos - 32A, 415V gr. 10KA breaking capacity, TPN MCB
Supply, Installation, Testing & commissioning of GTC hangar 2, UPS output Panel (PTTA panel) (IEC 60439 Standards)
Incoming
2Nos - 125A, 415V gr. 36KA, 4P MCCB
1No - 125A, Four Pole, Automatic transfer switch with controller
Lot-150A, 3Phase and 100A neutral 415V, short circuit rated 36KA for 1sec, TPN Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set-125/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 50KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A, 230V,10KA, SP MCB.
1Set- 6A, 230V, 10KA SP MCB for the protection of measuring instruments.
Outgoings:
6Nos - 63A, 415V gr. 10KA breaking capacity, TPN MCB
1No - 63A, 415V gr. 10KA breaking capacity, DP MCB
5Nos - 20A, 415V gr. 10KA breaking capacity, DP MCB
Supply, Installation, Testing & commissioning of Transmission hangar 3, Basement LT Panel (PTTA panel) (IEC 60439 Standards)
Incoming
1No- 320A, 415V gr. 36KA, 4P MCCB, TM based.
Lot-400A, 3Phase and 200A neutral 415V, short circuit rated 36KA for 1sec, TPN Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set-320/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 36KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A, 230V,10KA, SP MCB.
1Set- 6A, 230V, 10KA SP MCB for the protection of measuring instruments.
Outgoings:
1No - 100A, 415V gr. 36KA breaking capacity, TP+NL MCCB
1No - 80A, 415V gr. 10KA breaking capacity, TP+NL MCCB
3Nos - 63A, 415V gr. 10KA breaking capacity, TPN MCB
2Nos - 32A, 415V gr. 10KA breaking capacity, TPN MCB
Supply, Installation, Testing & commissioning of GTC hangar 1, AC Outdoor LT Panel (PTTA panel) (IEC 60439 Standards)
Incomer
1No - 400A, 415V gr. 36KA, Four Pole MCCB MP based
Lot - 500A TP + 250 N, 415V, short circuit rated 36KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1No- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1Set of - 400/5A current transformers of class 1 and 15VA burden for metering.
1No 6A 415V gr TP 36KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings
2 Nos - 80A 415V gr. 36KA TP+NL MCCB
3Nos - 63A 415V gr. 10KA TPN MCB
1No - 63A 415V gr. 10KA TPN MCB with suitable rated VFD for Clean room IDU of 3000CFM
1No - 40A 415V gr. 10KA TPN MCB
3Nos - 32A 415V gr. 10KA TPN MCB
3Nos - 32A 415V gr. 10KA DP MCB
Supply, Installation, Testing & commissioning of Transmission hangar 1, Ventilation LT Panel (PTTA panel) (IEC 60439 Standards)
Incoming
1-no 250A 415V gr 4P 36KA MCCB, TM based.
Lot - 300A, 4P, 415V, short circuit rated 36KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1Nos- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1 Set-250/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 36KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A, 230V, 10KA, SP MCB.
1Set- 6A, 230V, 10KA, SP MCB for the protection of measuring instruments.
Outgoing
1set - 100A, 415V gr. 36KA breaking capacity, TP+NL MCCB with suitable rated VFD for 20000CFM fresh air unit
1set - 100A, 415V gr. 36KA breaking capacity, TP+NL MCCB with suitable rated VFD for 18000CFM Exhaust air unit
1set - 63A, 415V gr. 36KA breaking capacity, TP+NL MCCB with suitable rated VFD for 14000CFM fresh air unit
1set - 63A, 415V gr. 36KA breaking capacity, TP+NL MCCB with suitable rated VFD for 12000CFM Exhaust air unit
4Nos - 20A 240V gr. 10kA rated DP MCB.
Supply, Installation, Testing & commissioning of Transmission hangar 2, Ventilation LT Panel (PTTA panel) (IEC 60439 Standards)
Incoming
1no - 200A 415V gr 4P 36KA, TM based MCCB.
Lot - 250A, 4P, 415V, short circuit rated 36KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1Nos- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1 Set-200/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 36KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A, 230V, 10KA, SP MCB.
1Set- 6A, 230V, 10KA, SP MCB for the protection of measuring instruments.
Outgoing
2sets - 63A, 415V gr. 36KA breaking capacity, TP+NL MCCB with suitable rated VFD for 14000CFM fresh air unit.
2Sets - 63A, 415V gr. 36KA breaking capacity, TP+NL MCCB with suitable rated VFD for 12000CFM Exhaust air unit
3Nos - 20A 240V gr. 10kA rated DP MCB.
Supply, Installation, Testing & commissioning of Transmission hangar 3, Ventilation LT Panel (PTTA panel) (IEC 60439 Standards)
Incoming
1-no 320A 415V gr 4P 36KA , TM based MCCB.
Lot - 400A, 4P, 415V, short circuit rated 36KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1Nos- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
1 Set-320/5A current transformers of suitable class and VA burden for metering.
1No 6A 415V gr TP 36KA MPCB for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A, 230V, 10KA, SP MCB.
1Set- 6A, 230V, 10KA, SP MCB for the protection of measuring instruments.
Outgoing
2sets - 100A, 415V gr. 36KA breaking capacity, TP+NL MCCB with suitable rated VFD for 20000CFM fresh air unit
2sets - 100A, 415V gr. 36KA breaking capacity, TP+NL MCCB with suitable rated VFD for 18000CFM Exhaust air unit
3-Nos 20A 240V gr. 10KA DP MCB.
Supply, Installation, Testing & commiissioning of OUTDOOR TIMER PANEL
1No- Modular digital time switch for street light & Building light control of Legrand Alpha Rex 3 D21 or equivalent approved make with two channel daily cycle unit suitable for daily programming to switch ON & OFF and operate on 230V single phase supply.
1No- 32A 230V gr.10KA 4P MCB with overload and short circuit protection.
1No-25A, Power contactor with AC coil of L&T Cat.No.MNX22 for 230V Single phase supply.
3Nos, 16A, 230V Gr, 10KA SP MCB with overload and shortcircuit protection.
Supply , Installation, Testing and Commissioning of 80KVA IGBT Based On-Line systems with 3Phase Input & 3Phase Output, with Isolation Transformer, 384VDC and battery bank comprising of minimum 12V-200AH X 32 Nos of SMF Battery including suitable Battery stand and interconnection between bateries, necessary copper cable connectivity from battery bank to UPS. The efficency of UPS sytem shall be more than 90% at 0.9 PF. (Note: Tenderer has to read detailed specification, given under Technical specification and quote accordingly)
Supply , Installation,Testing and Commissioning of 40KVA IGBT Based On-Line systems with 3Phase Input & 3Phase Output, with Isolation Transformer, 384VDC and battery bank comprising of minimum 12V-100AH X 32 Nos of SMF Battery including suitable Battery stand and interconnection between bateries, necessary copper cable connectivity from battery bank to UPS. The efficency of UPS sytem shall be more than 90% at 0.9 PF. (Note: Tenderer has to read detailed specification, given under Technical specification and quote accordingly)
Supply, fixing to/suspending from existing MS perlins/ ceiling at approx. 12-15 mtr height, using suitable MS angle frame work including necessary fixing hardwares etc., as per site requirement, testing & commissioning of industrial type highbay LED lighting fixture of wattage not exceeding 150watts made out of high pressure diecast aluminium housing, diffuser made of high grade toughened glass(or as per OEM standards), integral control gear, eye hook etc., . The technical parameters of lighting fixtures are as below: The luminaire should have Lumen efficacy ≥ 150lm/watt and lumen output not less than 22500lumens, PF>0.90 and Colour temprature shall be ≥5700K, THD <10%, operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V, Open Circuit protection, Over Voltage protection, Surge Voltage protection upto 10KV including necessary interconnections between driver and lighting fixtures and other standard accessories complete in all respects and as directed by Engineer in-charge. The fitting shall be of Havells model no: SAUCERGENXADVPROHBP150WLED857EPWBBORL / Equivalent model in other approved makes. LED used in the lighting fixtures should be one of the approved make. LM79 certification for luminares & LM80 certificate for LED shall be produced. Note: MS supports will be paid separately.
Supply, fixing in flush with the false ceiling including suitable fixing arrangment using Chain links, testing & commissioning of recess mounting type square LED clean room lighting fixture of wattage not exceeding 42watt with bottom opening/as per site requirement made out of white powder coated CRCA housing/ aluminium housing, front frame with translucent /polycarbonate opal diffuser including control gear. The luminaire should have Lumen efficacy ≥120 lm/watt and lumen output not less than 5000lumens with PF >0.9 and Colour temprature shall be ≥5700K, operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V, Output Short-circuit protection, Surge protection including necessary interconnections and other standard accessories complete in all respects and as directed by Engineer incharge. LED used in the lighting fixtures should be one of the approved make. LM79 certification for luminaires & LM80 certificate for LED shall be produced.The LED Light fixture shall be of Havells model no: BOCR 2X2 42W /Equivalent model in other approved makes luminaries which meets the above technical specification. LED used in the luminaire should be one of approved make as per approved make list of HAL.
Supply, fixing in flush with the false ceiling including suitable fixing arrangment using Chain links, testing & commissioning of recess mounting type square(2'X2') LED lighting fixture of wattage not exceeding 36watt made out of white powder coated CRCA housing/ aluminium housing, front frame with translucent /HT opal diffuser including control gear. The luminaire should have Lumen efficacy ≥120 lm/watt and lumen output not less than 4300 lumens with PF >0.9 and Colour temperature shall be ≥5700K operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V, Output Short Circuit Protection, Surge Voltage Protection including necessary interconnections and other standard accessories complete in all respects and as directed by Engineer incharge. LED used in the lighting fixtures should be one of the approved make. LM79 certification for luminaires & LM80 certificate for LED shall be produced.The LED Light fixture shall be of Havells Model No: RKL VENUSEXL2X2PLR36WLED857SWH/ Equivalent model in other approved makes luminaries which meets the above technical specification. LED used in the luminaire should be one of approved make as per approved make list of HAL.
Supply and fixing in flush with the false ceiling testing & commissioning of round type surface/recess mounted LED downlighter with aluminium die-cast body, finish with premium white powder coating, wattage not exceeding 15W LED lighting fixture, lumens efficiency ≥ 110lm/w at luminaire level, Colour temprature shall be ≥5700K, operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V. LM79 certification for luminare & LM80 certificate for LED shall be produced, including control gear. Pwer factor of control gear shall be >0.90. of Model No: Havells ZIVAFLRDDLR15WLED857S/ZIVASURRDDLR15WLED857S/Equivalent model in other approved makes luminaries which meets the above technical specification. LED used in the luminaire should be one of approved make as per approved make list of HAL.
Supply and fixing on ceiling/in flush with the false ceiling as per site requirement testing & commissioning of round type Surface/recess mounted LED downlighter with PDC aluminium housing and high translucent diffucer, wattage not exceeding 18W LED lighting fixture, lumens efficiency ≥ 110lm/w at luminaire level, effficent heat sink, Colour temprature shall be ≥5700K, operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V. 79 certification for luminare & LM80 certificate for LED shall be produced, including control gear, power factor of control gear shall be >0.90. Model No: Havells ZIVAFLRDDLR18WLED857S / ZIVASURRDDLR18WLED857S/ Equivalent model in other approved makes luminaries which meets the above technical specification. LED used in the luminaire should be one of approved make as per approved make list of HAL.
Supply and fixing on existing wall / ceiling, testing & commissioning of surface mounting, Batten type 2X18W/20W T8 LED Tube light (four feet) Luminaries with minimum lumens output Efficacy of minimum 100 lm/W., comprising of white powder coated CRCA sheet steel housing, operating on single phase 230V 50Hz AC supply, built-in electronic driver, LM 79 certification for luminaire. Other standard accessories including necessary inter-connections and supply of 2 Nos of 18/20W T8 LED Tube, complete in all respects and as directed by engineer-in-chage. Make & model: The LED tube & batten shall be of CROMPTON-IGP161LT8-16.2XT8+LT8-20-865-(2) /Equivalent model of approved make luminaries which meets the above technical specification and as directed by Engineer-in-charge.
Supply and fixing on existing wall / ceiling, testing & commissioning of surface mounting, Batten type 1X18W/20W T8 LED Tube light (four feet) Luminaries with minimum lumens output Efficacy of minimum 100 lm/W., comprising of white powder coated CRCA sheet steel housing, operating on single phase 230V 50Hz AC supply, built-in electronic driver, LM 79 certification for luminaire. Other standard accessories including necessary inter-connections and supply of 1 No of 18/20W T8 LED Tube, complete in all respects and as directed by engineer-in-chage. Make & model: The LED tube & batten shall be of CROMPTON-IGP161LT8-16.1XT8+LT8-20-865/Equivalent model of approved make luminaries which meets the above technical specification and as directed by Engineer-in-charge.
Supply & fixing on the building at a height of 4-6mtr approx. including supply and fixing GI pipe bracket made out of 40mm dia class B GI pipe of 1.5Mtrs long bent to shape with necessary fixing hardwares etc., to fix on building / and testing & commissioning of LED light fixture of wattage not exceeding 70watts and lumens output not less than 7700 lumens with necessary interconnections consisting of pressure die cast aluminum housing, optical cover made out of heat resistance toughened clear glass / polycarbonate lens with IP66, operating on single phase 230V 50Hz AC supply, efficient heat sink, colour temperature shall be 5700K±5%, suitable optics for maximizing the spread complete in all respects and as directed by engineer-in-change. The luminaries shall have specific lens for optical dispersion including control gear and power factor of control gear shall be >0.95. The fitting shall have internal surge protection of 4KV and external surge protection of 10KV(If internal surge protection of 10KV or more is available, then external protection is not required). LM 79 certification for luminaries & LM80 certificate for LED shall be produced. Any approved make fitting meeting the above technical specification has to be supplied.The LED Light fixture shall be of Crompton model no:TRP-409-70-57-SL-GL-NSG /Equivalent model in other approved makes luminaries which meets the above technical specification. LED used in the luminaire should be one of approved make as per approved make list of HAL.
Supply, fixing directly to the ceiling/wall testing and commissioning of 10W LED bulkhead light fitting with die cast aluminium body with Poly carbonate front cover, including driver, the driver shall have PF >0.9 and Colour temprature shall be >5600K, IP65 rated THD <20% operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures complete in all respect and as directed by EIC. The lighting fixture shall be of Crompton model no: LBHE-10-WW/Equivalent make in other approved makes.
Supply & fixing on existing MS hook 1200mm sweep,Five star rated with brushless direct current motor(BLDC) Ceiling fans complete with blades, down rods, and accessories, 230V single phase 50Hz AC supply. Minimum air delivery 210cu.m/min with service value 6.00 BEE , erected in position with necessary flexible copper leads of required colour and with canopy, down rod 300mm to 600mm length as per site requirement , necessary rubber bushings, clamps nuts,bolts etc., complete in all respects and as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of 300mm dia 900 rpm heavy duty exhaust fan of any approved make with louvers, connecting cord with 6A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of 450mm dia 1400 rpm heavy duty exhaust fan of any approved make with louvers, connecting cord with 6A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of 600mm dia 900 rpm heavy duty exhaust fan of any approved make with louvers, connecting cord with 6A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of 750 mm dia Air Circulator Fan along with three speed regulator of any approved make connecting cord with 6A, 3 pin plug top and with all necessary accessories, etc., complete in all respects and as directed by Engineer-in-charge.
Supply and fixing of weather proof cable junction box with terminals of size 104mm x 104mm x 70 mm Hensel Cat. No. DK DK 0402 G or equivalent in Legrand/ Schneider/ Hagar make only. The Box shall be mounted at suitable height on the truss using suitable size MS angle frame work with painting as per EIC, with cable entry knock-outs, including rigid support for all components, Din channel, required fasteners totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-65 complete in all respects and as directed by Engineer-in-charge. Note: MS supports will be paid separately.
Distribution Boards
8way VTPN MCCB DB.
6way VTPN MCCB DB.
4way VTPN MCCB DB.
4way VTPN MCB DB
6 way HTPN MCB DB
4 way HTPN MCB DB
12 way SPN MCB DB
8 way SPN MCB DB
MCCBs, MCBs & RCBO
160A, 25KA, FP 415V, MCCB
100-125A, 25KA, FP 415V, MCCB
63A, 25KA, FP 415V, MCCB
40-63 amps. ratings, FP MCB, "C" curve, 10 KA breaking capacity.
25-32 amps. ratings, FP MCB, "C" curve, 10 KA breaking capacity.
40-63 amps. ratings, TP MCB, "C" curve, 10 KA breaking capacity.
6A to 32A TP MCB 10kA , C Curve
40-63 amps. ratings, DP MCB, "C" curve, 10 KA breaking capacity.
6A to 32A DP MCB 10kA , C Curve
40-63 amps. ratings, SP MCB, "C" curve, 10 KA breaking capacity.
6-32 amps. ratings , SP MCB, "C" curve, 10 KA breaking capacity.
RCBO 4P 40A 300mA
Powder coated enclosure with MCBs/MCCBs/SDFUs
Supplying and fixing 20 amps, 240 volts, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc., as required.
Supply & fixing in flush with the wall/on wall , factory-built powder coated sheet steel enclosed using suitable angle iron frame work, 32A, 415V, 5 pin PVC socket outlet with plug top, controlled by 1 no. 32A 415V 4pole MCB with overload and short circuit releases including necessary interconnections, chipping the wall and replasting to smooth finish wherever necessary complete in all respects and as directed by Engineer in charge. (scope includes MS frame work as per requirement)
Supply & fixing in flush with the wall/on wall , factory-built powder coated sheet steel enclosed using suitable angle iron frame work, 63A, 415V, 5 pin PVC socket outlet with plug top, controlled by 1 no. 63A 415V 4pole MCB with overload and short circuit releases including necessary interconnections, chipping the wall and replasting to smooth finish wherever necessary complete in all respects and as directed by Engineer in charge. (scope includes MS frame work as per requirement)
Supply, fixing on wall/grouting to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer, testing and commissioning of 80-100A 25kA 4P 415V gr. MCCB in a factory built powder coated sheet steel enclosure, MCCB shall be adjustable with thermal settings (80% to 100%), overload and short circuit releases including door interlocking device, front operating handle complete,ON and OFF indication of LED module etc., complete in all respects. including suitable cable end box(incoming/outgoing) if any required wherever necessary complete in all respects and as directed by Engineer-in-charge. (scope includes MS frame work as per requirement)
Supply, fixing on wall/grouting to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer, testing and commissioning of 125A 25kA 4P 415V gr. MCCB in a factory built powder coated sheet steel enclosure, MCCB shall be adjustable with thermal settings (80% to 100%), overload and short circuit releases including door interlocking device, front operating handle complete,ON and OFF indication of LED module etc., complete in all respects. including suitable cable end box(incoming/outgoing) if any required wherever necessary complete in all respects and as directed by Engineer-in-charge. (scope includes MS frame work as per requirement)
Supply, fixing on wall/grouting to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer, testing and commissioning of 160-200A 25kA 4P 415V gr. MCCB in a factory built powder coated sheet steel enclosure, MCCB shall be adjustable with thermal settings (80% to 100%), overload and short circuit releases including door interlocking device, front operating handle complete,ON and OFF indication of LED module etc. complete in all respects. including suitable cable end box(incoming/outgoing) if any required wherever necessary complete in all respects and as directed by Engineer-in-charge. (scope includes MS frame work as per requirement)
Supply, fixing on wall/grouting to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer, testing and commissioning of 250A 25kA 4P 415V gr. MCCB in a factory built powder coated sheet steel enclosure, MCCB shall be adjustable with thermal settings (80% to 100%), overload and short circuit releases including door interlocking device, front operating handle complete,ON and OFF indication of LED module etc., complete in all respects. including suitable cable end box(incoming/outgoing) if any required wherever necessary complete in all respects and as directed by Engineer-in-charge. (scope includes MS frame work as per requirement)
Supply, fixing on wall/grouted to the floor 600mm above floor level, using suitable angle iron frame work, testing and commissioning of the 400A, 415V Gr, TPN powder coated, Switch disconnector fuse unit with equal rating DIN type HRC fuses, front operating handle,ON and OFF indication using LED module etc., enclosed in sheet steel enclosure, including suitable cable end box(incoming/outgoing) if any required wherever necessary complete in all respects and as directed by Engineer-in-charge. (scope includes MS frame work as per requirement)
Supply, installation(surface/recess), testing and commissioning of 4 Way Powder coated Enclosure/ outdoor type Sintex box with provision to mount MCB/RCCB/RCBO and suitable cut out for cable entry including 32A 4P MCB of 10kA, C curve as directed by Engineer-in-charge.
Supply, installation(surface/recess), testing and commissioning of 4 Way Powder coated Enclosure/ outdoor type Sintex box with provision to mount MCB/RCCB/RCBO and suitable cut out for cable entry including 63A 4P MCB of 10kA, C curve as directed by Engineer-in-charge.
Supply, laying, testing & commissioning of following size Aluminium LT armoured power cables.
3.5 CX 300 Sqmm Aluminium armoured conductor.
3.5CX 240 Sqmm Aluminium armoured conductor
3.5CX 185 Sqmm Aluminium armoured conductor
3.5CX 150 Sqmm Aluminium armoured conductor
3.5CX 120 Sqmm Aluminium armoured conductor
3.5CX 95 Sqmm Aluminium armoured conductor
3.5CX 50 Sqmm Aluminium armoured conductor
3.5 CX 25 Sqmm Aluminium armoured conductor.
4CX 10 Sqmm Aluminium armoured conductor
3CX 10 Sqmm Aluminium armoured conductor
Supply, laying, testing & commissioning of following size Copper LT armoured power cables.
4C X 70 Sqmm Copper armoured conductor LT Power Cable
4C X 25 Sqmm Copper armoured conductor LT Power Cable
4C X 16 Sqmm Copper armoured conductor LT Power Cable
4C X 10 Sqmm Copper armoured conductor LT Power Cable
4C X 6 Sqmm Copper armoured conductor LT Power Cable
3C X 16 Sqmm Copper armoured conductor LT Power Cable
3C X 10 Sqmm Copper armoured conductor LT Power Cable
3CX 4 Sqmm Copper Armoured conductor.
3C X 2.5 Sqmm Copper armoured conductor LT Control Cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor cable of 1.1 KV grade as required
3.5C X 300 sq. mm Al arm cable
3.5C X 240 sq. mm Al arm cable
3.5C X 185 sq. mm Al arm cable
3.5C X 150 sq. mm Al arm cable
3.5C X 120 sq. mm Al arm cable
3.5C X 95 sq. mm Al arm cable
3.5C X 50 sq. mm Al arm cable
3.5C X 25 sq. mm Al arm cable
4C X 10 sq. mm Al arm cable
3C X 10 sq. mm Al arm cable
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE armoured copper conductor cable of 1.1 KV grade as required
4Cx70Sqmm Armoured Copper cable
4Cx25Sqmm Armoured Copper cable
4Cx16Sqmm Armoured Copper cable
4Cx10Sqmm Armoured Copper cable
4Cx6Sqmm Armoured Copper cable
3Cx16Sqmm armoured Copper cable end termination
3Cx10Sqmm armoured Copper cable end termination
3C X 4 Sqmm Copper Armoured LT Cable End Joint
3C X 2.5 Sqmm Copper Armoured LT Cable End Joint
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5Cx120-185 Sqmm Aluminium armoured cable
3.5Cx240Sqmm Aluminium armoured cable
3.5Cx300Sqmm Aluminium armoured cable
Wiring for light point / fan point / exhaust fan point/call bell point from nearest switch box with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, fan regulator, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per detailed CPWD specifications for Group C wiring)
Wiring to single light point/Fan point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to two light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to three light point controlled by 1 No 6A, 250V gr. flush modular type SP switch complete in all respects.
Wiring to exhaust fan point using 6A, 250V gr. flush type modular SP switch housed along with other lighting switches/separate switch box if required and 3pin 6A, 250V gr. modular type socket housed near the exhaust fan complete in all respects.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for twin control light point(for two lights) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 2sets of 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing following suitable size GI/PVC Box with modular plate and cover on front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16A modular socket outlet and 15/16 A modular switch, connections etc., as required.
Supplying and fixing following suitable size GI/PVC Box with modular plate and cover on front on surface or in recess, including providing and fixing 2sets of 6 pin 5/6A & 15/16A modular socket outlet and 15/16 A modular switch, connections etc., as required.
Supplying and fixing following suitable size GI/PVC Box with modular plate and cover on front on surface or in recess, including providing and fixing 6sets of 6 pin 5/6A & 15/16A modular socket outlet and 15/16 A modular switch, connections etc., as required.
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
3 x 2.5 sq. mm (As per SLD)
3 x 4 sq. mm (As per SLD)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20MM PVC Conduit
25MM PVC Conduit
32MM PVC Conduit
Supplying and fixing of Hot dip galvanised Perforated type cable tray without cover of following sizes, steel: As per IS:2062 / 1079, Galvanising : As per IS: 2629 / 4759 including all accessories like base slotted angle , horizontal elbow, horizontal tee, horizontal cross, horizontal reducer, vertical elbow up, inside, vertical elbow down, outside, coupler plate, fasteners etc. (Note:-M.S. angle supports will be measured separately).
Supplying and fixing of 300 x 50 x 1.6mm size Hot dip galvanised Perforated type cable tray
Supplying and fixing of 450 x 50 x 2mm size Hot dip galvanised Perforated type cable tray
Supply, fabricating and installing of Following size perforated GI cable trays with cover including horizontal and vertical bends, reducers, tees, cross members, fasteners and other accessories as required and duly suspended from the ceiling/fixing to the wall/RCC beam/iron structures as per site requirement complete in all respects and as directed by Engineer in charge. (Note:-M.S. angle supports will be measured separately).
Supply, fabricating and installing of 100 x 50 x 2mm thick cable tray with 1.6mm thick cover.
Supply, fabricating and installing of 150 x 50 x 2mm thick cable tray with 1.6mm thick cover.
Supply, fabricating and installing of 200 x 50 x 2mm thick cable tray with 1.6mm thick cover.
Supply, fabricating and installing of 300 x 50 x 2mm thick cable tray with 1.6mm thick cover.
Supply, fabricating and installing of 450 x 50 x 2mm thick cable tray with 1.6mm thick cover.
Earthing & lightning protection
Supply & providing earth stations using 600x600x3.15mm thick copper plate electrode complete at 2.5 mtr. below the ground level with 20mm dia class B G.I pipe for watering, G.I funnel etc. & Cement concrete base of minimum size 750x750x100mm thick shall be provided using 1:2:6 CC after necessary excavation, refilling of soil, consolidating, ramming, leveling of soil etc. and providing cement concrete chamber of inside dimension 300x300x300mm with a wall thickness of 120mm using 1:2:6 CC above the base concrete including providing 50mm thick RCC cover including required salt & charcoal, 2runs of 50x6 mm(300mm) copper strip from plate electrode upto top of the chamber etc. as per technical specification enclosed with the tender documents & as per IS 3043 complete in all respects[For existing Transformer neutral earthing].
Supply & providing GI earth stations using 600 x 600x 6.3 mm thick G.I plate electrode at 2.5 mtr. below the ground level with 20mm dia class B G.I pipe for watering, G.I funnel etc. & Cement concrete base of minimum size 750x750x100mm thick shall be provided using 1:2:6 CC after necessary excavation, refilling of soil, consolidating, ramming, leveling of soil etc. and providing cement concrete chamber of inside dimension 300x300x300mm with a wall thickness of 120mm using 1:2:6 CC above the base concrete including providing 50mm thick RCC cover including required salt & charcoal, 2 runs of 50x6 mm G.I strip from plate electrode upto top of the chamber etc. as per technical specification enclosed with the tender & as per IS 3043 complete in all respects.
Supply, fixing & connecting the 50X6mm size G.I strip on wall / clamping to the existing duct wall / fixing on steel structures/ laying 2 ft. below the ground level including necessary cutting, bending, shaping, welding and fixing hardware/fasteners as per site requirment and as directed by Engineer-in-charge. Note:- Excavation, concrete cutting & re concreting will be measured separately.
Supply, fixing & connecting the 40X6mm size Copper strip on wall / clamping to the existing duct wall / fixing on steel structures/ laying 2 ft. below the ground level including necessary cutting, bending, shaping, welding and fixing hardware/fasteners as per site requirment and as directed by Engineer-in-charge. Note:- Excavation, concrete cutting & re concreting will be measured separately.
Supplying & laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply & fixing on the top of the building/hangar 3 pronged lightning conductor finials fixed on 20 mm dia copper tube 2 mtrs. long with Copper plate base 300x200x5mm thick. Base & fixing arrangements for the down conductors/GI strip complete in all respects and as directed by the Engineer-in-charge. Note: Base to be installed on porcelian insulators.
Supply, fixing & connecting the 25x3mm(75 sqmm) size G.I strip on parapet wall / clamping to the existing duct wall / fixing on cable tray/ clamping on wall with suitable size epoxy insulators at a spacing of 0.8mtr to 1mtr (between 2 insulators) including fixing hardware complete in all respects and as directed by the Engineer-in-charge.
Supply & spreading 75mm thick sand cushioning on top & bottom of the two runs of cable and covering the cable by well burnt bricks on sides and top of the cables as per technical specifications enclosed and as directed by the Engineer-in-charge.
Excavation in all types of soil for Cable trench including refilling, consolidating of soil after laying the cable including ramming and levelling to smooth finish as per the Technical specifications enclosed and as directed by the Engineer-in-charge.
Concrete cutting/Chipping/Bitumen Road the existing 1:2:4 cement concrete road /pavements / flooring / rock/stone etc., including removing debris from the work site and depositing in the place as directed by EIC.
Re-concreting the cut portion/closing the dummy cable duct at same area with 1:2:4 cement concrete by employing 20mm graded aggregate granite to smooth finish including curing and form work if any complete in all respects and as directed.
Design, Fabrication, Supply and fixing/grouting in wall/ceiling of suitable size MS angle iron supports/ flat for cable tray supports, high bay light fixture supports and etc., as per site requirement and painting the same with two coats of synthetic enamel paint over a coat of zinc chromite primer complete in all respects and as directed by EIC/OIC.
Supply and laying of 160mm dia, PE-100, PN8 ISI marked HDPE pipe confirming to IS 4984:1995 including suitable jointing using welding as required in the excavated trench/duct/at road crossings for encasing cables complete in all respect as directed by Engineer-in-charge.
HT cable
Supply and laying in already excavated trench / masonary duct/ encasing in pipe/ fixing on wall using necessary M.S clamps testing & commissioning of 3C x 240sqmm 11KV XLPE insulated earthed aluminium conductor armoured HT U.G cable as specified in the technical specifications to the tender document and as directed by Engineer-in-charge. Note:- Excavation, concrete cutting and reconcreting will be measured separately.
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3 core 240SQmm, XLPE aluminium conductor cable of 11 KV grade as directed by Engineer-in-charge.
Carrying out Mechanized Horizontal directional drilling of soil under the existing road/gate way for laying 2runs of HDPE pipe including supply and laying 2 runs of 125mm dia PE100 PN08 HDPE pipes, any ISI approved make conforming to IS 4984:1995 including suitable jointing using welding as required, providing pull tapes in the laid HDPE pipe, ends brought out, the brought out ends shall be sealed with suitable material to prevent soil and water entry and buried under soil. A cement concrete route marker shall be grouted in the soil above both the end of pipes with mark "End of pipes 2Rx125mm"complete as directed by Engineer in charge. [Refer Tender drawing].
Carrying out Mechanized Horizontal directional drilling of soil under the existing road/gate way for laying 1run of HDPE pipe including supply and laying 1 run of 125 mm dia PE100 PN08 HDPE pipes, any ISI approved make conforming to IS 4984:1995 including suitable jointing using welding as required, providing pull tapes in the laid HDPE pipe, ends brought out, the brought out ends shall be sealed with suitable material to prevent soil and water entry and buried under soil. A cement concrete route marker shall be grouted in the soil above both the end of pipes with mark "End of pipes 1Rx125mm"complete as directed by Engineer in charge.
Data Items
Supply, fixing and programming of Managed Layer 2 network switch with 48 ports, RJ-45 autosensing 10/100/1000 ports, 4 SFP+ ports complete in all respects as per the details broughtout in technical specifications and as directed by Engineer-in-charge. Approved Make : Cisco/ HP/ Juniper/ Dlink /Extreme
Supply, fixing and programming of Managed Layer 2 network switch with 24 ports, RJ-45 autosensing 10/100/1000 ports, 4 SFP+ ports complete in all respects as per the details broughtout in technical specifications and as directed by Engineer-in-charge. Approved Make : Cisco/ HP/ Juniper/ Dlink /Extreme
Supply, installation, testing and commissioning of 10G SFP+ LC LR 10km SMF Transceiver (should be same make of switches supplied), complete in all respects as directed by Engineer-in-charge. Note: For uplink/downlink from the existing switch, Transreceiver shall be of existing switch make as per site requirements.
Supply and laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/ iron supports/HDPE pipe, of 12 core Single Mode armoured, loose-tube, Gel-filled, 9/125 micron Fiber Optic cable, including OTDR testing for OFC cable complete in all respects as per technical specification and as directed by Engineer-in-charge. Approved Make:COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supply and fixing of wall Mountable 15U Network Rack with 2nos of Power Distribution unit(5 nos of 6/16A sockets in each PDU) and Dual cooling Fan, earthing cable, hardware etc. with all standard Accessories, complete in all respects as per technical specification and as directed by Engineer-in-charge. Approved Make:APC/VALRACK/NETRACK/RITTAL
Supply and fixing of wall Mountable 12U Network Rack with 1 no Power Distribution unit (5nos of 6/16A sockets in each PDU) and one cooling Fan, earthing cable, hardware etc. with all standard Accessories, complete in all respects as per technical specification and as directed by Engineer-in-charge. Approved Make:APC/VALRACK/NETRACK/RITTAL
Supply and fixing of fully Loaded, 48 Port CAT6A UTP Jack Panel, including termination of CAT 6A cables in Jack panel labelling complete in all respects as per technical specification and as directed by Engineer-in-charge. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supply and fixing of fully Loaded, 24 Port CAT6A UTP Jack Panel, including termination of CAT 6A cables in Jack panel, labelling complete in all respects as per technical specification and as directed by Engineer-in-charge. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supply and fixing of Fully loaded 12 Port LIU fiber LC style singlemode, 19-inch Rack mount panel with adapter plates, fiber pig tails, connectors including splicing and labelling. complete in all respects and as directed by Engineer-in-charge. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supply and fixing of Fully loaded 24 Port LIU fiber LC style singlemode, 19-inch Rack mount panel with adapter plates, fiber pig tails, connectors including splicing and labelling. complete in all respects and as directed by Engineer-in-charge. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supply and fixing of Fiber Optic Patch Cord (LC-LC) SM Type - 2 meter, complete in all respects and as directed by Engineer-in-charge. Approved Make:COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supply, fixing and labelling of Cat 6A UTP 4-Pair 2Meter length Patch cord, complete in all respects as per technical specification. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supply, drawing, testing and submission of test report of Cat 6A UTP 4-Pair cable in the existing PVC conduits inside wall / above false ceiling, including necessary interconnections as directed by Engineer-in-charge. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX/HAL approved makes
Supply, Fixing in flush with wall/on Aluminium partition as per site condition, testing & Commissioning of 2 nos of RJ-45 modular type sockets for Data points including supply of suitable size modular MS/PVC surface mounting box with base plates, glossy finish front covers, labelling etc., with necessary interconnections and chipping the wall, replastering to smooth finish etc., wherever required complete as directed by Engineer-in-charge. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX/Legrand/Schneider/HAL approved makes
Supply and laying of 32mm dia size PN8, PE-80 HDPE pipe with ISI marking confirming to IS 4984:1995 with necessary connecting / welding sockets / couplings / Tees/Bends in the excavated trench/duct/at road crossings for encasing OFC cables complete and as directed by Engineer-in-charge. Make: Rishi/Hasti/any make with ISI mark as per standards
Supply and fixing of Route Markers made up of 35x35x5mm Langle (600mm - 700mm length) with name plate of size(200x300x5mm). 2coats of red oxide and one coat of suitable approved colour painting for angle/ plate/markings. Route marker shall be 300mm below the ground leve. Rate shall include necessary excavation and concreting for route marker complete in all respects as directed by Engineer-in-charge.
Supply, shifting & positioning of Cement Chamber of size 2.5'X2.5' with cover Lid as per site requirements complete in all respects as directed by Engineer-in-charge.
Supply, fixing and termination of OFC cables in Splicing Enclosure -24 Port (Single/multi Mode as per site requirement) including all accessories to complete jointing of OFC cables in all respects as directed by Engineer-in-charge. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX
Supply, fixing and termination of OFC cables in Splicing Enclosure -12 Port (Single/multi Mode as per site requirement) including all accessories to complete jointing of OFC cables in all respects as directed by Engineer-in-charge. Approved Make: COMMSCOPE TYCO/ PANDUIT/ MOLEX
Telephone facility
Supply & fixing on wall / grouted to floor 1200mm above ground level using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 100 pair krone type telephone connectors junction box including krone connector/s with necessary mounting frame housed in suitable size outdoor type powder coated enclosure box of 16Guage (top canopy cover to avoid stagnation of water) with hinged lockable cover complete in all respects.
Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 100 pair krone type telephone connector junction box including krone connector/s with necessary mounting frame housed in suitable size FRP box with hinged lockable cover complete in all respects.
Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 50 pair krone type telephone connector junction box including krone connector with necessary mounting frame housed in suitable size FRP box with hinged lockable cover complete in all respects.
Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 20 pair krone type telephone connector junction box including krone connector/s with necessary mounting frame housed in suitable size FRP box with hinged lockable cover complete in all respects.
Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 10 pair krone type telephone connector junction box including krone connector/s with necessary mounting frame housed in suitable size FRP box with hinged lockable cover complete in all respects.
Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/ steel structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 100 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly- laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects and as directed by EIC.
Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/ steel structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 50 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly- laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects and as directed by EIC.
Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/ steel structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 20 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly- laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects and as directed by EIC.
Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/ steel structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 10 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly- laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects and as directed by EIC.
Supply & drawing of 0.5 mm dia copper conductor PVC insulated 4 pair colour coded and twisted unarmoured telecommunication cables in the existing PVC conduit as per standard practice including necessary inter connections & end terminations.
Supply, Fixing, in flush with wall/on Aluminium partition as per site condition, suitable size modular MS box with base plate, glossy front cover for supply and housing of 1 No. of RJ-11 telephone socket outlets with necessary interconnections, chipping the wall and replastering to smooth finish complete in all respects and as directed by Engineer-in-charge.
Supply and making straight through termination of Thermo Shrink Filled jointing Kits (TSF) type C with required materials for jointing of Underground armoured telephone cable of conductor size 0.5mm Dia for the following capacity complete in all respects and as directed by EIC. Note 1: Telephone jointing Buttons for above jointing kits to be included in the quote. Note 2: Excavation, concrete cutting will be paid separately if any.
20 pair jelly filled armoured copper conductor of 0.5mm dia (TSF-1 kit)
50 pair jelly filled armoured copper conductor of 0.5mm dia (TSF-2 kit)
100 pair jelly filled armoured copper conductor of 0.5mm dia (TSF-3 kit)
Rupees Six Crore Twenty Six Lakh Thirteen Thousand One Hundred Twelve and Seventy Seven Paise Only
INTELLIGENT FIRE ALARM SYSTEM
Supplying, installation, testing and commissioning of micro processor based intelligent addressable 2 loop main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history login the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) of suitable range(min 60mtr) as complete with emitter and receiver including connections with remote test features etc., complete as required.
Supply and installation of PVC type response indicators with LED indications for above false ceiling detectors and shall comply to BS-5839/EN54/IS2189 standards for installation and product shall be UL / FM / Vds approved.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supply, Installation, testing and commissioning of Auto Dailer including the cost of mounting accessories with addressable control module integrated with main control panel with minimum 10 telephone nos. connectivity complete as directed by Engineer-in-charge.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Rupees Forty Four Lakh Ninety Eight Thousand Nine Hundred Sixty and Sixty Five Paise Only
Design, fabrication, supply, installation, testing and commissioning of machine room less electric traction type, Stainless steel elevator of 13 passenger (884kg) capacity and suitable for operation on 415 V±10%, 3 phase, 50Hz AC supply, having AC variable voltage and variable frequency type traction control, speed of 1.00 Mtr/sec, electromagnetic brake system, Simplex operation, operating panel with luminous buttons, overload waming indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to HAL's EPABX, infrared ray sensing door protection for full height reverse phase relay on controller, fireman's switch at initial landing floor, Dot matrix digital display indication of positions and direction indication in car and landings, and at all floors with UP/DOWN direction, braille buttons, audio announcement along with prerecorded message, LED light fixtures, ventilation fan, etc. complete with all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device with lever operated (button operated) (independant of any battery system) along with structural supports, frames etc. complete as required.
Rupees Thirty Two Lakh Ninety Six Thousand Five Hundred Only
Rupees Seven Crore Four Lakh Eight Thousand Five Hundred Seventy Three and Forty Two Paise Only
Design, Supply, installation, testing and commissioning of Double skin floor mounted air washer unit with the capacity of 20000 CFM(side throw as required at the site) , minimum of 125mm total static pressure or higher as per design, 50 mm thick (EU-4) Box Type Pre Filter, 305mm thick EU-7 fine filter. Humidification Section with 300mm deep cellulose pad, stainless steel sump, suitable capacity pump & GI internal piping & necessary valves.Eliminator Section with 4 bend PVC Eliminator.Fan section with imported DIDW Backward curved Fan, Drive set with V belt & Motor (IE-2). The complete unit shall be provided with 18 gauge canopy if required to avoid rain water as per site requirement.The motor of unit should be VFD compatible.The unit should be run and controlled through VFD.VFD has been considered in the elctrical scope of work
Design, Supply, installation, testing and commissioning of Double skin floor mounted air washer unit with the capacity of 14000 CFM(side throw as reuired at the site), minimum of 125 mm total static pressure or higher as per design, 50 mm thick box type (EU-4) Box Type Pre Filter, 305mm thick EU-7 fine filter. Humidification Section with 300mm deep cellulose pad, stainless steel sump, suitable capacity pump & GI internal piping & necessary valves .Eliminator Section with 4 bend PVC Eliminator.Fan section with imported DIDW Backward curved Fan, Drive set with V belt & Motor (IE-2). The complete unit shall be provided with 18 gauge canopy if required to avoid rain water accumulation as per site requirement complete in all respect and as directed by EIC. The motor of unit should be VFD compatible.The unit should be run and controlled through VFD.VFD has been considered in the elctrical scope of work
Supply and installation, testing & commissioning of outdoor 18000CFM Tube Axial type Exhaust Fan with 125 mm WG Static or higher as per design for MGB area Ventilation including suitable civil works for foundation, with suitable inlet for connecting exhaust duct as per OEM complete in all respect and as directed by EIC.The complete unit shall be provided with 18 gauge canopy to avoid rain water accumulation complete in all respect and as directed by EIC. The motor of unit should be VFD compatible.The unit should be run and controlled through VFD.VFD has been considered in the elctrical scope of work
Supply and installation, testing & commissioning of outdoor 12000CFM Tube Axial type Exhaust Fan with 125 mm WG Static or higher as per design for MGB area Ventilation including suitable civil works for foundation, with suitable inlet for connecting exhaust duct as per OEM complete in all respect and as directed by EIC.The complete unit shall be provided with 18 gauge canopy to avoid rain water accumulation complete in all respect and as directed by EIC.The motor of unit should be VFD compatible.The unit should be run and controlled through VFD.VFD has been considered in the elctrical scope of work
Supply and installation of extruded aluminium powder coated supply air grills neck Size of min 550mm with 150mm/200mm width with collar damper to modulate the flow.(Note: Measurement will be taken for neck size)
Supplying, fixing, testing & commissioning of Return air grills of Size of minimum 550mm lenght with 150mm/200mm width without collar damper powder coated suitable for fixing on return/exhaust air duct. (Note: Measurement will be taken for neck size)
DUCTING : Design, supply, installation & testing and commissioning of factory fabricated GSS ducting as per IS 655 with zinc coating of minimum class VIII ie. 120GSM total on both sides as per IS 277 complete with suspenders of MS rods / wall MS brackets, cradles, angle iron supports, bolts and nuts, gaskets, stiffeners, canvas connections, fixing of anchor grip bolts, zinc chromate painted angle iron flanges/Transverse duct connectors, chipping and plastering of opening made for duct supports, outside air intakes complete with bird screen, damper,collar, bowl, rough filters etc., complete as per specifications and as directed by Engineer-in-charge.: Note:1. Scope includes cutting and closing of wall/wall GI sheet with suitable sealant. 2. Duct supports as per above specificaiton shall be measured separately.
24Guage
22 guage
Supply, installing and testing of Factory fabricated GI Volume Control damper(Manual)made of GI sheet construction 16G GI blade, 16G GI frame, lever mechanism comprising of Steel spindles, blade linkages with suitable handle operation including status indicator for main and branch duct, ON/OFF indicators for dampers complete in all respect and as directed by Engineer-in-charge.
Supply,installation,testing and commissioning 150mm depth fire dampers fabricated out of minimum 16 gauge GI sheet construction and 18 gauge GI blades complete with chrom plated spindle, self lubricating bushes with 90-120Minutes fire rating as per UL 555 with 600mm extended sleeves as applicable with fusible link, complete in all respect.
Ducting Acoustic Insulation: Supply & Installation of Acoustic insulation for Supply air ducts with 15 mm thick open cell nitrile rubber with OEM recommended adhesive and density 140 kg / cum having open cell foam structure of Class 1 fire category as per technical specification.
Supply, Installation & Testing of Thermal Insulation for Supply air ducts with 13mm thick Class-O, Close cell elastomeric nitrile insulation with suitable OEM recommended adhesive and density not less than 40kg/cum. Joints shall be overlapped and joints sealed with 75 mm wide aluminium foil self adhesive tape/suitable tape as per technical specification, complete in all respect and as per standard practice.
Supply and Fixing of Underdeck insulation for blower/ AHU room's ceiling using 13mm thick Closed cell chemically cross linked polyethelene foam density of 30 kg/cum insulation material with one side factory laminated aluminium sheet to fix the insulation on the ceiling with additional support of GI frame/strip works for entire insulated area using GI washers and tie wires on perlins including all accesseries and required hardware as per site requirement and as directed by Engineer in charge. Note : Contractor should make sure that there should not be any sag after fixing the insulation.
Supply, Fixing of Acoustic insulation for AHU room on the existing wall using 25 mm thick nitrile rubber open cell insulation with OEM recommended adhesive and density 140kg/cum having open cell foam structure of class 1 fire category provided in the suitable GI frame work as per site requirement. Complete in all respect as directed by Engineer in Charge.
Supply, installation testing and commissioning of 1.5 TR minimum capacity invertor Hi wall Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor and 5 star rated as per BEE and with suitable stabilizer with suitbale wall bracket for Indoor unit & MS stand/frame for Outdoor unit, suitable vibration isolators as required as per manufacturers recommendation, suitably sized copper refrigerant piping as per OEM standard upto a length of 3 mtrs(both suction and liquid piping) including 19 mm thick closed cell nitrile rubber tubular insulation interconnecting indoor & outdoor units with required pipe fittings and accessories like bends, tees, reducers, refnets, supports, necessary power/control cabling, suitably supported on trays/ split clamps etc., CPVC condensate drain pipe upto a length of 3 mtrs suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell nitrile rubber tubular insulation, required pipe fittings and accessories like bends, tees, reducers, supports, clamps, first charge refrigerant gas R32/R410A/R407C, cordless remote etc., including chasing, drilling, concealing and making good the same on walls and replastering of left out portion of wall with good finish and paininting with matching colour etc., complete in all respects . (Note:Copper piping and drian pipe, as required beyond 3mtrs as per site requirement will be measured separately)
Rupees One Crore Twenty Two Lakh Seventy Seven Thousand Two Hundred Only
Design, Supply, installation, testing and commissioning of the minimum 24 HP capacity of Air-cooled VRF/VRV (Variable Refrigerant Flow/Variable Refrigerant volume ) modular type Outdoor unit mounted on suitable MS frame for connecting DX type VRV indoor caseete unit with multiple variable speed, energy efficient inverter driven Scroll/rotary compressors as per specifications complete with suitable capacity drive motors, air-cooled condenser, including first charge of refrigerant gas R410A/R407C/R-32, oil separator with all accessories and safety devices as per OEM standards, high-low pressure cut-off, ODU vibration isolators . ODU unit shall be suitable for operating on 3 phase, 380-415V, 50Hz power supply with all associated electrical works including, power cabling to nearest power point for compressors and condenser fan motors along with internal control and power wiring, cooling coil with internally interconnected refrigerant pipes, Y joints/ refnet joints, for interconnecting various capacity modules as applicable (to make unit of above HP), charging port and the entire unit shall be with weather resistant powder coating paint for continuous outdoor operation. The scope includes power or control cabling between indoor and outdoor units
Design, Supply, erection, testing and commissioning of minimum 2.0 TR capacity, Four directional/ Rounded air flow Cassette type Indoor Air Conditioning Units suitable for mounting inside false ceiling, each comprising of cooling coil, blower with multi speed motor, electronic expansion valve, supply & return air grilles, filter, insulated connection of refrigerant circuit, provision for fresh air intake, condensate water drain pump with electronic level sensor, including suitable size LT copper cable connecting to the nearest existing plug & socket, necessary mounting arrangement for suspending the unit from ceiling etc. Scope includes Remote controller (Cordless) for each unit including batteries and necessary cutting of existing false ceiling for fising the unit. Note: Power supply to individual indoor unit will be provided near to IDU . Refer tender drawing and annexure -A under AC technicla specificaiton. NOTE: Out of 53, 40 nos will be VRF compatible as indicated in the annexure A and tender drawing and balance 13 nos will be for DX air conditioing units as mentioned in annexure A and tender drawing.
Design, Supply, erection, testing and commissioning of minimum 1.5 TR BEE -5 star rated capacity, Dx type cassette unit Four directional/ Rounded air flow Air Conditioning Units suitable for mounting above false ceiling, each comprising of cooling coil, blower with multi speed motor, electronic expansion valve, supply & return air grilles, filter, insulated connection of refrigerant circuit, provision for fresh air intake, condensate water drain pump with electronic level sensor, including suitable size LT copper cable connecting to the nearest existing plug & socket, necessary mounting arrangement for suspending the unit from ceiling etc. Scope includes Remote controller (Cordless) for each unit including batteries and necessary cutting of existing false ceiling. Note: Power supply to individual indoor unit will be provided near to IDU to tap power supply complete in all respect as per technical specification and EIC/OIC.Refer tender drawing and annexure -A of AC technical specification
Design, Supply, installation, testing and commissioning of suitable size hard/soft refrigerant copper pipe as required with required pipe fittings , accesories, filter drier and couplings by good quality pipe joints which laid between ODU and IDU The Minimum copper pipe gauge shall be as per the gauges indicated by manufacturer. The Pipe sizes to be used as per OEM design recommendation. The Refrigerant pipe shall be insulated with Class O nitirle rubber of 19 mm thick for Gas line and 19 mm thick for liquid line. The piping shall be laid on walls / roof / ceiling well supported at specific intervals with metallic support, Cable tray with cover and required hardwares etc as required ., for fixing copper pipes. All the necessary accessories, jointing / brazing etc shall be carried out as required. The pressure testing of refrigerant piping has to be done as per manufacturer design recommendation. All the copper fittings shall be suitable for R 410 A/R 407R 134a//R-32 refrigerant. . Make: Mandev/Piyush/Totaline (Note: 1. Irrespective of diameter both gas and liquid piping shall be measured as a single item. The single item measurement comprising of gas line, liquid line, insulation and its accessories. Contractor make a note of it and quote accordingly.
Design,supply,Installation testing & commissioning of suitable sizes as per OEM recommonadation not less than 2mm thick CPVC drain water / fresh air arrangement pipe including U-traps, vlaves for AHU drain,reducer, bends, collars & elbow etc, all complete and duly insulated with 9 mm thick tubular insulation of closed cell elastomeric nitrile rubber as required.The PVC drain water pipe/fresh air pipe shall be complete with fittings, accessories and duly insulated using bends, elbows, tees, wall sleeves, hangers, supports, anchors etc.(Note:.1 Pipe used for fresh air intake to IDU shalll be coverd with mesh. 2. Necessary wall openings and closing the same using cement mortar and matching paint finish after taking out pipes is included in the scope of work. ) Make: Supreme/Finolex/Hycount/Saroplast
Supply, installtion of Fresh air intake louvers made of extruded aluminium with bird/insect screen provided with intake louvers. The lowest louvers of the assembly shall extend out slightly to facilitate disposal of rain water without falling on the door / wall on which it is mounted and complete with all aluminium construction volume control dampers.
Supply , installtion & testing 250 to 375mm suitable dia preinsulated flexible ducts with 25mm thick glass wool insulation covered with aluminum foil suitable for connecting branch ducts with the diffuser boxes including with circular clip complete in all respect and as per standard practice. Make: ATCO/Seven Star/Supaflex
Supply & installation of flexible connections constructed of fire resistance flexible double canvas sleeve as per required size suitable for AHU mouth with zip for measurement of CFM etc. Complete in all repsect and as directed by EIC.
Supply, installation, testing and commissioning of Ceiling mounted 16G Aluminum terminal HEPA module , gaskets, Stainless steel perforated sheet and volume control damper operated from clean room side. The provision for DP across the HEPA filter shall be provided. Terminal box & filter shall be loaded from clean room side. Filter shall be certified as per EN1822 standard. Efficiency:- 99.997% Down to 0.3 μ, MoC : Aluminum Extrusion, IPD/FPD : 25/60 mm of WC or as per design.The scope includes suitable butterfly damper and mixing box.All necesssary fixtures to secure the false ceiling in the module shall be part of the scope.Size of HEPA filter shall be not less than 600*600*140 mm
Wall panelling: Design, Supply and Installation of100mm thick Self standing double skin Non progressive modular wall panel system made with 0.8mm thick Powder coated GI steel sheets on both sides with PUF of density 40 + or - 2kg per m3 as Infill. GI profiles for reinforcement along the periphery floor track suitable to accommodate the epoxy floor flush with the wall panel joints. The joints shall be sealed with clean room compatible silicon sealant including flashing , accessories & fixing material for wall. Note:- 1. The panel shall be suitable for fixing doors and making cut-outs to fix RA grills if any, electrical module boxes, , indicators etc as required., utility piping, conduits inside the panel for Power(if required), LAN, Telephone cabling etc. The wall panels shall be complete with all required accessories. 2. The power / sockets and Lighting fixtures shall be provided as per BOQ. 3. Scope of work shall includes required flashing accessories and suitable Covings, corner cups, etc. Make:Fabtech / M+W zander / Rinac / SRP / I-clean / GMP Technical Solutions / Sri Modular Clean rooms.
Design, Supply, and erection of 50 mm thick double skin totally flush walkable false ceiling panels made with not less than 0.8mm thick Powder coated GI steel sheets on both sides with PUF of density 40±2 kg /m3 as Infill with suitable ceiling grid and necessary hardware for supporting the ceiling panels. Joints shall be sealed with clean room compatible silicon sealant. Note:- 1. The scope includes making necessary cutouts to fix Supply air HEPA filters, LED lighting fixture for required numbers as per BOQ. Ceilings to be sealed to prevent ingress of air bearing particles or other contaminants. 2. Suitable Covings, corner cups, etc.are inclduded in the scope of work. Make:Fabtech/M+W zander/Rinac/SRP/I-clean/GMP Technical Solutions/ Sri Modular Clean rooms.
Design, Supply, and erection of 100mm thick Inbuilt return air riser having 0.8 mm thick GI sheet on both sides,suitable to connect wall panel, panel with suitable cutout for return air grilles for clean room application.
Supply and installation of Aluminum powder-coated grills with damper in return air riser panel as per approved shop drawing.
Clean room single swing door - 1.0 m W x 2.1m H, mm,standard 40mm thick of PUF infill as insulating material, 0.8 mm thick PCGI Panels. Door frame 1.2 mm thick PCGI. Double glazed float 5 mm view glass. Door closer, SS kick plate, SS 'D' type handles , SS Door lock, single side key operated locking arrangement, Door in closed condition to be suitably sealed to prevent ingress of air bearing particles or other contaminants inside the clean room etc. complete in all respect and as directed by Engineer-in-charge
Supply, installation, testing and commissioning of Dynamic pass box (GI powder coated) of inner dimension 900mmX900mmX 900mm(WXDXH) including required accessories complete in all respect and as directed by EIC.
Supply, installation and commissioning of personal Air shower, single entry and single exit, high velocity, low pressure system SS304 nozzles, pre and HEPA fillers, completely self contained unit, CRCA powder coated modular type Air shower of class 100 of not less than overall internal dimension 900 mm x 1000 mm x 1900 mm. The dimensions indicated are approximate. The exact dimensions shall be checked at site before submitting the drawings for approval by for the department. Unit shall be complete with aluminium grated floor, LED lights, prefilters, HEPA filters and door interlocks. Unit shall be prewired and ready for assembly complete in all respect.
Providing cut-outs in wall/ceiling panel during fabrication of panel at factory or site for fixing electrical modular switch board boxes, DB, indicators if any etc., of required sizes as per site requirement.
Carrying out the following testing activities, Air borne particulate testing, Filter velocity & Integrity Test, Temperature / RH Test with data logger(3 days), Pressure monitoring & balancing, Air balancing, Recovery Test. Note: Hygrometer and temp display is to be provided in clean room area and the cost towards the same is to be included
Carrying out Qualification, Validation, & Documentation of clean room. Validation of all systems as per ISO 14644 with HVAC qualification documents DQ / IQ / OQ / PQ as per norms
Design, Supply, installation, testing and commissioning of the minimum 10 HP capacity of Air-cooled VRF/VRV (Variable Refrigerant Flow/Variable Refrigerant volume ) modular type Outdoor unit mounted on suitable MS frame for connecting DX type VRV/VRF-AHU unit with multiple variable speed, energy efficient inverter driven Scroll/rotary compressors as per specifications complete with suitable capacity drive motors, air-cooled condenser, including first charge of refrigerant gas R410A/R407C/R-32, oil separator with all accessories and safety devices as per OEM standards, high-low pressure cut-off, ODU vibration isolators . ODU unit shall be suitable for operating on 3 phase, 380-415V, 50Hz power supply with all associated electrical works including, power cabling to nearest power point for compressors and condenser fan motors along with internal control and power wiring, cooling coil with internally interconnected refrigerant pipes, Y joints/ refnet joints, for interconnecting various capacity modules as applicable(to make unit of above HP), charging port and the entire unit shall be with weather resistant powder coating paint for continuous outdoor operation. The scope includes power or control cabling between indoor and outdoor units.The scope also includes supply , installation , testing and commissioning of VRV/VRF-AHU connectivity kit for AHU for clean room as mentioned in BOQ.Note: 1 no of 10 HP ODU will be connected to ceiling suspended AHU of 3000 cfm for clean room and other 10 HP will be connected to VRV type casette indoor units as mentoned in annexure A.
Design, Supply, installation, testing and commissioning of the minimum 20 HP capacity of Air-cooled VRF/VRV (Variable Refrigerant Flow/Variable Refrigerant volume ) modular type Outdoor unit mounted on suitable MS frame for connecting VRV indoor caseete unit/split ac with multiple variable speed, energy efficient inverter driven Scroll/rotary compressors as per specifications complete with suitable capacity drive motors, air-cooled condenser, including first charge of refrigerant gas R410A/R407C/R-32, oil separator with all accessories and safety devices as per OEM standards, high-low pressure cut-off, ODU vibration isolators . ODU unit shall be suitable for operating on 3 phase, 380-415V, 50Hz power supply with all associated electrical works including, power cabling to nearest power point for compressors and condenser fan motors along with internal control and power wiring, cooling coil with internally interconnected refrigerant pipes, Y joints/ refnet joints, for interconnecting various capacity modules as applicable (to make unit of above HP), charging port and the entire unit shall be with weather resistant powder coating paint for continuous outdoor operation. The scope includes power or control cabling between indoor and outdoor units. For location refer annexure A in technical specification.
Design, Supply, installation, testing and commissioning of the minimum 5 HP capacity of Air-cooled VRF/VRV (Variable Refrigerant Flow/Variable Refrigerant volume ) modular type Outdoor unit side throw or top throw as per OEM mounted on suitable MS frame for connecting DX type VRV indoor caseete unit/split ac with multiple variable speed, energy efficient inverter driven Scroll/rotary compressors as per specifications complete with suitable capacity drive motors, air-cooled condenser, including first charge of refrigerant gas R410A/R407C/R-32, oil separator with all accessories and safety devices as per OEM standards, high-low pressure cut-off, ODU vibration isolators . ODU unit shall be suitable for operating on 3 phase, 380-415V, 50Hz power supply with all associated electrical works including, power cabling to nearest power point for compressors and condenser fan motors along with internal control and power wiring, cooling coil with internally interconnected refrigerant pipes, Y joints/ refnet joints, for interconnecting various capacity modules as applicable (to make unit of above HP ), charging port and the entire unit shall be with weather resistant powder coating paint for continuous outdoor operation. The scope includes power or control cabling between indoor and outdoor units
Design, Supply, installation, testing and commissioning of the minimum 8 HP capacity of Air-cooled VRF/VRV (Variable Refrigerant Flow/Variable Refrigerant volume ) modular type Outdoor unit side throw or top throw as per OEM mounted on suitable MS frame for connecting DX type VRV indoor caseete unit/split ac with multiple variable speed, energy efficient inverter driven Scroll/rotary compressors as per specifications complete with suitable capacity drive motors, air-cooled condenser, including first charge of refrigerant gas R410A/R407C/R-32, oil separator with all accessories and safety devices as per OEM standards, high-low pressure cut-off, ODU vibration isolators . ODU unit shall be suitable for operating on 3 phase, 380-415V, 50Hz power supply with all associated electrical works including, power cabling to nearest power point for compressors and condenser fan motors along with internal control and power wiring, cooling coil with internally interconnected refrigerant pipes, Y joints/ refnet joints, for interconnecting various capacity modules as applicable (to make unit of above HP ), charging port and the entire unit shall be with weather resistant powder coating paint for continuous outdoor operation. The scope includes power or control cabling between indoor and outdoor units.For location refer annexure A in technical specification .
Rupees Eighty Six Lakh Sixty Four Thousand Two Hundred Twenty Four Only
Design, Manufacturing, transport, Erection, Testing and Commissioning of 5 Ton capacity box type double girder, E.O.T crane with a span of 35mtrs (approx), lift height of 6.5mtrs, bay length 60 mtrs(approx) complete in all respect and comprising of crab hoist, electrical controls, cabling, as per standard practice and other required accessories, in EOT crane technical specification Annexure-I and as directed OIC/EIC.
Supply, Fixing, Testing and Commissioning of shrouded bus bar 125A- 4 row GI DSL system with all required accessories complete in all respects and as per the technical specifications Annexure-I and as directed OIC/EIC. .
Supply, Erection and commissioning of 50 MM bright Square bar for above crane with all necessary accessories complete in all respect on both sides of bay length and as per the technical specifications Annexure-I in technical specification and as directed OIC/EIC
Design, Manufacturing, transport, Erection, Testing and Commissioning of 10Ton capacity box type double girder, E.O.T crane with a span of 35mtrs (approx), lift height of 11.5mtrs, bay length 45 mtrs(approx) complete in all respect and comprising of crab hoist, electrical controls, cabling, as per standard practice and other required accessories. and as per the technical specifications Annexure-Iin technical specification and as directed OIC/EIC
Design, Manufacturing, transport, Erection, Testing and Commissioning of 3Ton capacity box type single girder E.O.T crane with a span of 9mtrs (approx), lift height of 4mtrs,bay length11mtrs(approx) and if required as per site requirement access ladder from cat walk to top of crane bridge platform as per the technical specifications and Annexure complete in all respect and comprising of crab hoist, electrical controls, cabling and other required accessories as per standard practice.
Supply, Erection and commissioning of 40mm Square bar crane rail section with all necessary accessories complete in all respect on both sides to a bay length for all above said 4 cranes for hydraulic power pack, GTC Hanagr1 (2 places at Diagonally opposite),test bench/rig room, sound proof hydaulic power pack in GTC hangar 1 annexe . Annexure-I and as directed OIC/EIC. .
Design, Manufacturing, transport, Erection, Testing and Commissioning of 5Ton capacity box type double girder, E.O.T crane with a span of 32 mtrs (approx), lift height of 6.5 mtrs, bay length 45mtrs(approx) complete in all respect and comprising of crab hoist, electrical controls, cabling, as per standard practice and other required accessories. Annexure-I in technical specification and as directed OIC/EIC. .
Design, Manufacturing, transport, Erection, Testing and Commissioning of 5 Ton capacity box type double girder, E.O.T crane with a span of 12mtrs (approx), lift height of min 6 mtrs, bay length 13 mtrs(approx) complete in all respect and comprising of crab hoist, electrical controls, cabling, as per standard practice and other required accessories. Location- Transmission hangar 1&2 .Refer tender drawing
Design, Manufacturing, transport, Erection, Testing and Commissioning of10 Ton capacity box type double girder, E.O.T crane with a span of 12mtrs (approx), lift height of min 11 mtrs, bay length 17 mtrs(approx) complete in all respect and comprising of crab hoist, electrical controls, cabling, as per standard practice and other required accessories. (MGB LOAD TEST RIG AREA) HANAGAR-3.The cranes to be ercetd on common rail , for which anti-collision device to be considered and to be quoted accordoingly.Location- Transmission hangar 3 .Refer tender drawing
Design, Manufacturing, transport, Erection, Testing and Commissioning of10 Ton capacity box type double girder, E.O.T crane with a span of 12mtrs (approx), lift height of min 11 mtrs, bay length 17 mtrs(approx) complete in all respect and comprising of crab hoist, electrical controls, cabling, as per standard practice and other required accessories. Location -Transmission hangar 3 ,refer tender drawing
Design, Manufacturing, transport, Erection, Testing and Commissioning of 2 Ton capacity under slung E.O.T Monorail Hoist with a span of 6mtrs (approx), lift height of 3.5 mtrs (approx) on existing 250mm ISMB Monorail as per the technical specifications and Annexure complete in all respect and comprising of hoist, electrical controls, cabling and other required accessories as per standard practice. Location -Transmission hangar 3 ,refer tender drawing
Rupees Three Crore Thirteen Lakh Eighty Five Thousand Two Hundred Fifty Only
Design, supply, installation, testing and commissioning of vertical type Air Reciever of 1000 liters capacity suitable for a working pressure of 10bar, as per IS2825 ASME section VIII Div complete with pressure guage, safety valve, manual drain, flanged inlet and outlet shall be 80 Nb, inspection cover as required, including mounting frame, foundation bolts etc., complete in all respects.
Supply, installation on a suitable angle iron frame work testing & commissioning of compressed Air Moisture separator with flanged ends suitable for 80mm dia..
Supply installation & commissioning of pre filter of 8 kg/cm²
Supply installation & commissioning of fine filter of 8 kg/cm²
Supply and installation of interconnected piping between compressor discharge valve, air dryer, receiver and filters, complete as per the drawing and technical specification. ground/fixing on duct wall/ wall using suitable angle iron supports, clamps etc., testing & commissioning of the following size "Class C " ERW grade GI heavy duty pipes and fittings confirming to IS:1239&1879 with necessary cutting, welding/threading wherever necessary including GI fittings like Flanges, bends, collars, reducers, tees etc., with necessary fixing hardware and painting complete in all respects as per technical specifications and as directed by Engineer in charge
40 mm dia NB pipe
15 mm dia NB pipe
80mm NB pipe
Supply, welding/threading, testing & commissioning Butterfly Valve.of following dia
80 MM DIA
40 MM DIA
Supply, welding/threading, testing & commissioning of 15mm dia 3 piece SS ball (socket type) valves regular bore, lever operated, body and end connectors of carbon steel including operating handle for the compressed air outlet.
Supply, welding/threading, testing and commissioning of 15mm dia quick release single coupling for the compressed air outlets consisting of both socket and plug for hose pipe of 6mm dia & suitable for working pressure of 7.0bar complete in all respect.
Supply, welding/threaded, testing & commissioning of compressed air Automatic liquid drain trap of 15mm dia.
Supply, installation, testing and commissioning of Pressure gauge 2" dial with 15NB isolation valve inclluding all accessories complete and as directed by EIC.
Rupees Thirty Eight Lakh Forty Five Thousand Eighty Only
Rupees Five Crore Sixty One Lakh Seventy One Thousand Seven Hundred Fifty Four Only
Rupees OneThree Crore Three Lakh Thirteen Thousand One Hundred Eighty and Sixty Nine Paise Only
Approximate Amount Put to Tender
Rupees Eighteen Crore Fifty Four Lakh Fifty Six Thousand Three Hundred Seventy Two and Fifty Two Paise Only
Rupees OneTwenty One Crore Fifty Seven Lakh Sixty Nine Thousand Five Hundred Fifty Three and Twenty One Paise Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
TN66.pdf
TENDER_DOCUMENT • 1.38 MB
155CHECKLIST.pdf
TENDER_DOCUMENT • 0.19 MB
155PQnew.xlsm
TENDER_DOCUMENT • 0.04 MB
155ECSForm.pdf
TENDER_DOCUMENT • 0.48 MB
155PQF.pdf
TENDER_DOCUMENT • 0.21 MB
ElectricalDrawings1.pdf
TENDER_DOCUMENT • 9.25 MB
CivilDrawings.pdf
TENDER_DOCUMENT • 2.52 MB
ElectricalDrawings2.pdf
TENDER_DOCUMENT • 9.30 MB
ElectricalDrawings3.pdf
TENDER_DOCUMENT • 4.05 MB
MechanicalDrawings.pdf
TENDER_DOCUMENT • 3.51 MB
150155Amendment.pdf
TENDER_DOCUMENT • 0.23 MB
155UNDERTAKING.pdf
TENDER_DOCUMENT • 0.57 MB
155PBF.pdf
TENDER_DOCUMENT • 1.21 MB
155TBF.pdf
TENDER_DOCUMENT • 6.11 MB
155Amendment.pdf
TENDER_DOCUMENT • 0.10 MB
155PBFinal1.xlsm
TENDER_DOCUMENT • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .