| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC 42 43A VIDYA SAGAR SARANI PALLY BARISHA KOLKATA 700 008 | KOLKATA | WEST BENGAL | 700008 | ₹33.4 L Quoted ₹34.0 L | L1 | Accepted-AOC Being a lowest bidder |
| 2 | L2₹37.8 L+₹3.8 L (11.1%)Rejected-Finance | ₹37.8 L+₹3.8 L (11.1%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹38.9 L+₹4.9 L (14.3%)Rejected-Finance VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | ₹38.9 L+₹4.9 L (14.3%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹39.4 L+₹5.4 L (16.0%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | ₹39.4 L+₹5.4 L (16.0%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹39.8 L+₹5.8 L (17.0%)Rejected-Finance | ₹39.8 L+₹5.8 L (17.0%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
18 Mar 2022, 6:00 pmClosed
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/MAINT OF POWER FACTOR PANEL, ACB, LT PANEL, LT FEEDER PILLAR BOX, EARTHING AND LIGHTNING ARRESTOR AT FORT WILLIAM UNDER GE(FW) KOLKATA
2022_MES_509150_1
8829/E8
Open Tender
Civil Works
Item Rate
210 days
GE(FW) Kolkata
Ref tender documents
6 documents required · 6 mandatory
₹500
GE(FW) Kolkata
₹68,000
28 Mar 2022
18 Feb 2022
19 Mar 2022
18 Feb 2022
18 Mar 2022
4 Mar 2022
Amount
M&L for opening & disconnecting carefully LT cable connections from APFC Panels of 125 kVAr capacity, checking of panels installed at Main Power House & OTM power House and testing their operation and mechanical system including detection and replacement of the unserviceable parts/accessories required at site to make the Power factor Panel completely functional including cleaning/ servicing of complete unit and re-connection of the panel complete all as specified and directed. (Note :- Provision of new spare parts as required shall be measured and paid separately under relevant supply only items here-in-after)
-ditto- but for APFC Panel of capacity 30 KVAr to 40 kVAr, installed at RRC Sub Stn, ECCIU Sub Stn, Sub Stn No. 1, 2, 4, 7, 8 & 9
-ditto- but for APFC Panel of capacity 50 KVAr to 75 kVAr, installed at MES IB Sub Stn, Area Drainage, Cinema Hall & ASCON Sub Stn
Supply only APFC relay 8 steps 3 CT with RS-485 complete (Make: L&T, Cat No:CS91050OOOO or equivalent model in other makes specified in tender)
Supply only capacitor duty contactors, 5 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No: CS96127 or equivalent item in other makes specified in tender)
Supply only capacitor duty contactors, 10 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No: CS96156 or equivalent item in other makes specified in tender)
Supply only capacitor duty contactors, 15 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No: CS90019 or equivalent item in other makes specified in tender)
Supply only capacitor duty contactors, 20 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No: CS90021 or equivalent item in other makes specified in tender)
Supply only capacitor duty contactors, 25 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No: CS96322 or equivalent item in other makes specified in tender)
Supply only capacitor duty contactors, 30 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No:CS96148 or equivalent item in other makes specified in tender)
Supply only capacitor duty contactors, 50 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No:CS96324 or equivalent item in other makes specified in tender)
Supply only self healing type capacitor, 3 phase, 440 volts, 50 Hz, Cylindrical type of Capacity 5 kVAr complying with following specifications:- (i) Overcurrent withstand capacity upto 1.8 X In (ii) Peak Inrush current withstand capacity upto 300 times (iii) Operating losses not more than 0.45 W /kVAr (iv) No. of switching per year = 8000 (v) Max ambient temperature = 55 degree C (vi) Operating life = 1,50,000 hours
-ditto- but of capacity 10 kVAr
-ditto- but of capacity 15 kVAr
-ditto- but of capacity 20 kVAr
-ditto- but of capacity 25 kVAr
Supply only self healing type capacitor, 3 phase, 440 volts, 50 Hz, Box type of Capacity 5 kVAr complying with following specifications:- (i) Overcurrent withstand capacity upto 1.8 X In (ii) Peak Inrush current withstand capacity upto 300 times (iii) Operating losses not more than 0.45 W /kVAr (iv) No. of switching per year = 8000 (v) Max ambient temperature = 55 degree C (vi) Operating life = 1,50,000 hours
-ditto- but of capacity 10 kVAr
-ditto- but of capacity 15 kVAr
-ditto- but of capacity 20 kVAr
-ditto- but of capacity 25 kVAr
-ditto- but of capacity 30 kVAr
-ditto- but of capacity 50 kVAr
NOTE FOR ITEM NO. 12 TO 23:- (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that capacitor provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.)
S&F in repair Motorised Change Over Switch, open execution type, 415 Volts, 3 phase 4 pole, 125 Amps with AST Controller with wire harness to be fixed on existing panel board complete all as specified and directed. (Make: L&T, Cat No: CK90161BOOO + CK90192OOOO or equivalent model in other makes specified in tender)
S&F in repair Motorised Change Over Switch, open execution type, 415 Volts, 3 phase 4 pole, 200 Amps with AST Controller with wire harness to be fixed on existing panel board complete all as specified and directed. (Make: L&T, Cat No: CK90163BOOO + CK90192OOOO or equivalent model in other makes specified in tender)
S&F in repair Motorised Change Over Switch, open execution type, 415 Volts, 3 phase 4 pole, 400 Amps with AST Controller with wire harness to be fixed on existing panel board complete all as specified and directed. (Make: L&T, Cat No: CK90166BOOO + CK90192OOOO or equivalent model in other makes specified in tender)
S&F in repair Motorised Change Over Switch, open execution type, 415 Volts, 3 phase 4 pole, 630 Amps with AST Controller with wire harness to be fixed on existing panel board complete all as specified and directed. (Make: L&T, Cat No: CK90167BOOO + CK90192OOOO or equivalent model in other makes specified in tender)
Isolating the device and checking of LT ACBs 630-800 Amps capacity and testing its operation and tripping devices and mechanical system and setting it right clearing / servicing complete unit incl providing spares/accessories and recharging complete in position for Air Circuit Breaker of Make- GE , L&T, Crompton Greaves, Legrand or Schneider. Note :- Checking, overhauling and repairing work will be done by concerned company representative or OEM authorised person only.
Supply and fixing in repair 50 mm bore galvanized iron pipe (light grade) with all fittings, laid in trenches or fixed complete to wall / ceiling or laid in floor complete all as specified and as directed by the Engineer-in-charge.
M&L for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, as directed by the Engineer-in-Charge.
S&F in repair air termination, single pointed aluminium rod, 12 mm dia and 300 mm long, fixed on GI pipes with earthing strips for earth coductivity to ground complete all as specified and directed. (NOTE: GI pipe & earthing strip shall be measured and paid seperately)
S&F in repair air termination, single pointed copper rod, 12 mm dia and 300 mm long, fixed on GI pipes with earthing strips for earth coductivity to ground complete all as specified and directed. (NOTE: GI pipe & earthing strip shall be measured and paid seperately)
S&F in repair test point terminal block, made of gun metal or phosporous beonze of size 75 mm X 75 mm X 25mm, drilled and screwed including 3 Nos, 8 mm dia and 25 mm long hex screws complete all as specified and directed.
S&F in repair earth contuinity conductor with aluminium strips of size 25 mm X 3.15 mm, fixed to wall/on batten/recess/chases/ buried in ground/drawn in conduit or pipes/fixed to poles to test point or any other indicated situation for loop earthing duly fixed on porcelain insulators @ 1 metre spacing etc complete all as specified and directed. (NOTE: Cost of saddle, insulators shall be deemed to be incuded in the quoted rates)
S&F in repair copper strip 20 mm X 3.15 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground duly fixed on porcelain insulators @ 1 metre spacing etc complete all as specified and directed. (NOTE: Cost of saddle, insulators shall be deemed to be incuded in the quoted rates)
M&L in repair for glow sign board of size 1500 X 1000 x 300 mm, made of angle iron frame work as per site requirement with front side covered with 2mm thick acrylic sheet for writing letters in appropriate font size and other sides covered with 0.63 mm thick GI sheet, duly prewired and including 04 Nos LED tube light 18 watts inside the board incl necessary electrical connection from glow sign board to near switch board/PVC junction box with PVC copper cable 1.5 sqmm 3 core inside PVC conduitrigid/flexible as per site requirement and board fixed to angle iron frame incl necessary fixing arrangement such as angle iron , flat iron, channel etc complete all as specified and directed. NOTES:- (i) Data to be written on glow sign board shall be as directed by Engineer-in-Charge. (ii) MS section for erection of glow sign board shall be measured and paid seperately.
M&L in repair for glow sign board of area not exc 30 sqft, 300 mm thickness, made of angle iron frame work as per site requirement with front side covered with 2mm thick acrylic sheet for writing letters in appropriate font size and other sides covered with 0.63 mm thick GI sheet, duly prewired and including 06 Nos LED tube light 18 watts inside the board incl necessary electrical connection from glow sign board to near switch board/PVC junction box with PVC copper cable 1.5 sqmm 3 core inside PVC conduitrigid/flexible as per site requirement and board fixed to angle iron frame incl necessary fixing arrangement such as angle iron , flat iron, channel etc complete all as specified and directed. NOTES:- (i) Data to be written on glow sign board shall be as directed by Engineer-in-Charge. (ii) MS section for erection of glow sign board shall be measured and paid seperately.
M&L in repair for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling hole for bolts, in any shape of size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 32 X 6 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
S&F in repair surge protection device, 3 phase, 4 module type 1+2, for protection against direct and indirect lightning surge, maximum discahreg current 50 kA, fixed on LT panel including complete wiring wide adequate size of PVC copper cable complete all as specified and directed. (MAKE: L&T, Cat No: AUS0123PN50 OR equivalent model in ABB / HAGER / SCHNEIDER / LEGRAND/SIEMENS)
Supply and installation of advance encapsulated compound based CPRI tested and approved maintenance free, pipe-in-pipe technology upgraded (Zinc & Ally coated), zinc coated (80-100) microns with pure zinc (99.9%) & alloy coating (200-250 microns). Earthing system shall conform to IS 3034. The outer and inner pipe should be 48.3 mm and 26.4 mm dia, 3 metres length, zinc coated with additional special alloy coating 300 mm on the topside for additional corrosion protection of the terminal. The annular space between the pipes shall be filled up with Compact Fill (CF) crystalline conductive compound. The Compact Fill (CF) mixture which is machine pressed in the pipes should be extended with terminals for connectivity. The job includes necessary Excavation and earthwork for pits and returning and fillings complete by electrodite/ conductolite back fill comound (Ground enhancer). The back fill compound should be eco friendly and should not contain environmentally hazardous materials/metal having RoHS certification from NABL accredited lab. CONTD........
Item No. 42 Contd.... Earth used shall be free from any foreign materials/chemicals to fill the excavated Pits by mixing the same with BFC (as required by not less than 50 Kg) including PCC pit in cement concrete 1:3:6 type C1 using 20 mm graded aggregates and RCC pre-cast cover slab of size 450 x 450 x 50 mm in RCC 1:2:4 type B1 using 20 mm graded aggregates, reinforced with and including 8.0 mm dia TMT bars @ 100 mm centre to centre both ways or FRP pit cover and dismantling of existing unsv earthing complete all as specified and directed. (NOTES :- 1) The acceptable earth resistance at earth busbar/test point shall not be more than 01 Ohm. 2) The work shall be carried out by authorised trained rep of the OEM or experienced workmen as approved by GE.) (MAKE : ASHLOK / INDELAC / MACKMET / JMV LPS LTD)
Dismantling carefully serviceable isolating LT Panel of size 1600 x 900 x 600 mm to 2500 x 2000 x 900 mm duly unscrewing/opening front and back cover and cleaning complete bus bar chamber, tightning all the nuts, bolts, incoming and outgoing terminals including cleaning all the switchgear/accessories, replacement of cable gland and stainless steel hinges of size 100mm for panel board, fixed with welding arrangement incl applying one coat of synthetic enamel paint externally to panel board after scrubbing/cleaning the surface and testing the panel board to the entire satisfaction of Engineer-in-Charge. NOTES:- (i) Cost of necssary nuts, bolts, washers, screws and colour tape for bus bar, recharging and testing complete shall be deemed to be included in the quoted rate. (ii) Stainless steel hinges shall be provided as per qty required on site and quoted rate shall be deemed to be included in the quoted rates.
Dismantling carefully serviceable isolating LT Panel of size 500 x 500 x 500 mm to 1500 x 900 x 600 mm duly unscrewing/opening front and back cover and cleaning complete bus bar chamber, tightning all the nuts, bolts, incoming and outgoing terminals including cleaning all the switchgear/accessories, replacement of cable gland and stainless steel hinges of size 100mm for panel board, fixed with welding arrangement incl applying one coat of synthetic enamel paint externally to panel board after scrubbing/cleaning the surface and testing the panel board to the entire satisfaction of Engineer-in-Charge. NOTES:- (i) Cost of necssary nuts, bolts, washers, screws and colour tape for bus bar, recharging and testing complete shall be deemed to be included in the quoted rate. (ii) Stainless steel hinges shall be provided as per qty required on site and quoted rate shall be deemed to be included in the quoted rates.
Taking out unserviceable LT panel board/feeder pillar (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1500 mm x 1500 mm x 600 mm, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly spray painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer inclusive of 04 Nos copper bus bar of 630 Amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs & copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland) and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with angle iron frame with base 50X 50X 6 mm with legs not more then 60 cm including grouting with PCC, 1:2:4 type B1 complete including earthing all as directed by the Engr-in-Charge including S&F of the following accessories :-
MCCB (incoming) with thermal-magnetic release of capacity 400 Amps, 4 pole, 50HZ, 36 KA, Ics= 100% of Icu - 01 No. (Make: L&T, Cat No: CM998403OOROOG / HAGER, Cat No: HNJ401DR / ABB, Cat No: 1SDA054478R1 / SCHNEIDER, Cat No: LV432677 / LEGRAND, Cat No: 4220 07)
MCCB (Outgoing) with thermal-magnetic release of capacity 100 Amps, 4 pole, 50HZ, 25 KA, Ics= 100% of Icu - 03 Nos. (Make : L&T, Cat No: CM91712OOKOOG / LEGRAND, Cat No: 4200 55 / HAGER, Cat No: HHS101DR /SCHNEIDER, Cat No: LV429560 / ABB, Cat No: 1SDA067404R1)
MCCB (Outgoing) with thermal-magnetic release of capacity 63 Amps, 4 pole, 50HZ, 25 KA, Ics= 100% of Icu - 02 Nos. (Make : L&T, Cat No: CM91712OOHOOG / LEGRAND, Cat No: 420053 / SCHNEIDER, Cat No: LV429562/ ABB, Cat No: 1SDA067406R1 / HAGER, Cat No: HHS064DR)
CTs of ratio 630/5A (Set of 03) - 01 Set
LED indicating Lamp with holder for main supply & standby supply indicating RYB (Set of three) - 01 Set
MCB, SP 06 Amps, 10 KA, 'C' Curve - 03 Nos
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip.
Taking out unserviceable LT panel board/feeder pillar (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1500 mm x 1800 mm x 600 mm, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly spray painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer inclusive of 04 Nos copper bus bar of 800 Amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs & copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland) and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with angle iron frame with base 50X 50X 6 mm with legs not more then 60 cm including grouting with PCC, 1:2:4 type B1 complete including earthing all as directed by the Engr-in-Charge including S&F of the following accessories :-
MCCB (incoming) with thermal-magnetic release of capacity 630 Amps, 4 pole, 50HZ, 50 KA, Ics= 100% of Icu - 01 No. (Make: L&T, Cat No: CM94104OOT1OG / HAGER, Cat No: HMJ631DE / ABB, Cat No: 1SDA060204R1 / SCHNEIDER, Cat No: LV432894 / LEGRAND, Cat No: 4220 23)
MCCB (Outgoing) with thermal-magnetic release of capacity 100 Amps, 4 pole, 50HZ, 25 KA, Ics= 100% of Icu - 05 Nos. (Make : L&T, Cat No: CM91712OOKOOG / LEGRAND, Cat No: 4200 55 / HAGER, Cat No: HHS101DR /SCHNEIDER, Cat No: LV429560 / ABB, Cat No: 1SDA067404R1)
MCCB (Outgoing) with thermal-magnetic release of capacity 63 Amps, 4 pole, 50HZ, 25 KA, Ics= 100% of Icu - 02 Nos. (Make : L&T, Cat No: CM91712OOHOOG / LEGRAND, Cat No: 420053 / SCHNEIDER, Cat No: LV429562/ ABB, Cat No: 1SDA067406R1 / HAGER, Cat No: HHS064DR)
CTs of ratio 800/5A (Set of 03) - 01 Set
LED indicating Lamp with holder for main supply & standby supply indicating RYB (Set of three) - 01 Set
MCB, SP 06 Amps, 10 KA, 'C' Curve - 03 Nos
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip.
Taking out unserviceable Power Factor Panel (of any size) and Supply, install, commissioning and testing of Power Factor Improvement Static Condensor (Capacitor Banks) of capacity 70 kVAR panel, indoor type, cubical type, dust and vermin proof, made out of 2.0 mm thick CRCA sheet of size 1100 mm x 1100 mm x 500 mm, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly spray painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer inclusive of 04 Nos copper bus bar of 200 Amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs & copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland) and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS Channel (MC 75) with legs not more than 60cm including grouting with PCC, 1:2:4 type B1 complete including earthing all as directed by the Engr-in-Charge including supply and fixing of the following accessories :-
MCCB (incoming) with thermal-magnetic release of capacity 160 Amps, 4 pole, 50HZ, 36 kA, Ics= 100% of Icu - 01 No. (Make: L&T, Cat No: CM94104OOT1OG / HAGER, Cat No: HMJ631DE / ABB, Cat No: 1SDA060204R1 / SCHNEIDER, Cat No: LV432894 / LEGRAND, Cat No: 4220 23)
MCCB (Outgoing) with thermal-magnetic release of capacity 63 Amps, 3 pole, 50HZ, 25 KA, Ics= 100% of Icu - 02 Nos. (Make : L&T, Cat No: CM91712OOHOOG / LEGRAND, Cat No: 4200 53 / SCHNEIDER, Cat No: LV429562/ ABB, Cat No: 1SDA067406R1 / HAGER, Cat No: HHS064DR)
MCCB (Outgoing) with thermal-magnetic release of capacity 32-40 Amps, 3 pole, 50HZ, 25 KA, Ics= 100% of Icu - 04 Nos. (Make : L&T, Cat No: CM91712OOKOOG / LEGRAND, Cat No: 4200 55 / HAGER, Cat No: HHS101DR /SCHNEIDER, Cat No: LV429560 / ABB, Cat No: 1SDA067404R1)
02 Nos Capacitor, self healing type, 3 phase, 440 volts, 50 Hz, Box type of Capacity 15 kVAr complying with following specifications:- (i) Overcurrent withstand capacity upto 1.8 X In (ii) Peak Inrush current withstand capacity upto 300 times (iii) Operating losses not more than 0.45 W /kVAr (iv) No. of switching per year = 8000 (v) Max ambient temperature = 55 degree C (vi) Operating life = 1,50,000 hours contd......
-ditto- but capacitor of 10 kVAr capacity - 03 Nos
-ditto- but capacitor of 05 kVAr capacity - 02 Nos
APFC relay 8 steps 3 CT with RS 485 - 01 No (Make: L&T, Cat No:CS91050OOOO or equivalent model in other makes specified in tender)
Capacitor duty contactors, 440V, 3Ph, 50Hz - 06 Nos
Start/Stop Push Button - 06 Nos
Auxillary Contactor ($NO+NC) - 02 Nos
ON/OFF Indicating Lamp - 06 Nos
CTs of ratio 200/5A (Set of 03) - 01 Set
LED indicating Lamp with holder for main supply & standby supply indicating RYB (Set of three) - 01 Set
MCB, SP 06 Amps, 10 KA, 'C' Curve - 03 Nos
PVC Exhaust fan, 230 Volts, 50 Hz - 02 Nos
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip. (iii) List of approved makes has been provided in particular specifications. Contractor shall ensure that capacitor provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.)
M D CORPORATION
PRABIR TRADERS
MS AP CONSTRUTION AND CO
TOTCO
GHOSH ENTERPRISE
RAJ ENTERPRISE
M A ENTERPRISES
BASU AND CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .