| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-Finance | L1 | Accepted-Finance 1st Lowest Bidder | |
| 2 | L2₹2.0 L+₹39,862 (24.3%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest Bidder | |
| 3 | L3₹2.1 L+₹44,137 (26.9%)Rejected-Finance | L3 | Rejected-Finance 3rd Lowest Bidder |
Tender Value
₹1.9 L
EMD Value
₹2,000
Closing Date
24 Nov 2020, 5:00 pmClosed
Superintending Engineer
Electricity Transmission Circle, UPPTCL, 132 KV S/s Mohaddipur Old , Gorakhpur
WORK OF REWINDING AND SERVICING OF COOLING FAN AND PUMPS OF 100 MVA , 220/132 KV TRANSFORMER , REPLACEMENT OF DEFECTIVE CONTACTORS , RELAY , MCCB , INDICATION BULB FITTINGS , REWIRING AND PUSH BUTTON etc. AT 220 KV S/S HATA , KUSHINAGAR UNDER ETD-I ,
2020_UPTCL_522052_1
E-Tender No. 69-ETC(G)/2020-21
Open Tender
Electrical Works
Item Rate
90 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
SE, ETC, Gorakhpur
₹2,000
28 Nov 2020
17 Oct 2020
25 Nov 2020
17 Oct 2020
24 Nov 2020
17 Oct 2020
Amount
Complete Reqinding of 0.5 HP / 0.372 KW 3-phase ,415V , 1400 RPM Cooling fan motors of 100 MVA T/F at 220 KV S/s Hata , Kushinagar . The work covers complete dismantling of all parts of fan motor its rewinding by super enamel copper wire of same specification and gauge , virnishing of complete motor body , changing of damaged front and rear side bearings with new once of same size and standard make, oiling and greasing of all moving parts , reassembling of motor and testing for normal running of cooling fan with all cost of men , materials, carriage and T&P etc. required for the job.
Complete Overhauling of the 0.5 HP / 0.372 KW 3-phase ,415V , 1400 RPM Cooling fan of 100 MVA T/F including dismantling of its motor , changing ball , bearings with new once of same size and standard make, oiling and greasing of all moving parts , reassembling of motor and testing for normal running of cooling fan with all cost of men , materials and T&P etc. required for the job.
Complete Overhauling of the 03-phase, 0.5 HP / 3.7 KW , 1430 RPM Cooling pumps of 100 MVA 220/132 KV T/F including dismantling of its motor , changing of damaged ball , bearings with new once of same size and standard make, oiling and greasing of all moving parts , reassembling of motor and testing for normal running of cooling fan with all cost of men , materials and T&P etc. required for the job.
Complete Reqinding of the 03-phase, 0.5 HP / 3.7 KW , 1430 RPM Cooling fan motor of 100 MVA T/F at 220 KV S/s Hata, Kushinagar . The work covers complete dismantling of all parts of fan motor its rewinding by super enamel copper wire of same specification and gauge , virnishing of complete motor body , changing of damaged front and rear side bearings with new once of same size and standard make, oiling and greasing of all moving parts , reassembling of motor and testing for normal running of cooling fan with all cost of men , materials, carriage and T&P etc. required for the job.
Complete dismantling & replacement of following defective items of T/F M. Box & RTCC panel by its reqiring with 2.5mm2 / 10mm2 / 4.0 mm 2 copper wire as per requirement of lugs , ferrules , cable , tie , cable duct etc. with all cost of men , T&P , materials , consumables for the completion of work.
Thermal O/L relay 0.80-1.6 Amp. ( 1 NO+1NC)
Power Contactor coil voltage 9 Amp. , 230 V AC , 3 Main , 2NO+2NC contacts "Siemens / L&T / BCH/ ABB /C&S / HPL make.
MCB 6 Amp. / 415 V Siemens / L&T / BCH/ ABB /C&S / HPL make.
MCB 40 Amp. / 415 V , 3-phase , 4-pole Siemens / L&T / BCH/ ABB /C&S / HPL make.
Power Contactor coil voltage 415V AC , 40 Amp. , 3 Mains , 1NO+1NC contacts "Siemens / L&T / BCH/ ABB /C&S / HPL make.
Annunciator of 100 MVA T/F M/s Pradeep Sales make 20 window model P-352 suitable for RTCC panel of 100 MVA , 220/132 V T/F.
LED Indication Lamp fittings suitable Aux. Supply 220V AC.
WTI Repeater (RWTI) M/s Perfect make / any standard make suitable for perfect make WTI range 0-1500 C, Aux. 110V DC.
Complete reqiring of Transformer M.Box for running of cooling fan and cooling pumps in accordance of Temperature in auto mode after removing scattered wires, as per WTI aux. contacts for fan and pump running alarm and trip contacts as per direction of engineer incharge along with testing as per UPPTCL requirements with all cost of men , T&P , lugs and other consumables etc. required for the work.
M/s Ansh Traders
ARK ENGINEERING
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .