Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 CrAccepted-AOC | ₹21.9 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹22.7 CrRejected-AOC WARD NO 07 D K ROAD LAKHIMPUR ASSAM | ₹22.7 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹23.5 CrRejected-AOC | ₹23.5 Cr | L3 | Rejected-AOC L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not-Qualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not-Qualified |
Tender Value
Refer Docs
EMD Value
₹43.1 L
Closing Date
21 Nov 2020, 2:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Construction of Guwahati Municipal Corporation Office Building at Betkuchi, Garchuk, Guwahati-35
2020_PWBNH_19154_1
SMC/124/2020/ 2__GMC Office Betkuchi
Open Tender
Civil Works - Building
910 days
Garchuk
Please refer Tender documents.
6 documents required · 6 mandatory
₹12,500
Yes
Assam State Road Board Maintenance (Road) Fund
₹43.1 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
13 Dec 2022
3 Nov 2020
21 Nov 2020
3 Nov 2020
21 Nov 2020
3 Nov 2020
12 Nov 2020
Amount
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailling out water where necessary as directed and specified. Up to a depth pf 2.00 m below the existing ground level. In ordinary soil.
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).. In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine)
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) Using mixture machine In substructure up to plinth level Foundation, footing, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick. Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. M25 grade concrete
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) In super structure from plinth level up to 1st floor level. Using Batching Plant/ RMC/ Truck mounted batching plant including Transit Mixer and Concrete Pump Using admixture, plasticiser etc M25 grade concrete
Extra over for RCC works for each subsequent floor or part thereof above the 1st floor level.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) From Primary Producer: TATA/ SAIL/ Essar Steel/ Jindal steel/ Shyam steel/ RINL Super Ductile (SD) TMT reinforcement bars
Extra for each subsequent floor or part thereof above first floor level.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete plain concrete work in: Foundation, footings, base of columns, pile cap, raft and mass concrete works etc. Using 38mm thick plank.
Providing form work of 12mm thick Plywood Board / Steel so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Column, pillars, posts & strut : Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc. upto 200mm in thickness.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
Extra for shuttering in each subsequent floor or part thereof above the First Floor level
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level. In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) 112 mm thick brick wall In cement mortar in proportion 1:4.(1 cement:4 sand)
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. 112mm thick brick/ R.B wall
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. In cement mortar in proportion 1:4.(1 cement:4 sand) On rough side : In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. In cement mortar in proportion 1:4.(1 cement:4 sand) On fair side : In cement mortar 1:4
Extra for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed. Single coat of plaster
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. 15mm thick
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) Normal range (Somany/ Orient/ Nitco/ Varmora/ VITA/ Marbito Make) Of size 600mmx600mm and above
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/ Sika/ Pedelite/ Rouf)/ white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). (Somany/ Orient/ Nitco/ Varmora/ VITA/ Marbito Make) Of size 300mm x 450mm and above
Providing polished SUNROCK-Hi CTS/ MULTIWYN tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). MULTIWYN TILES (Legato, Ribbera, Matrix, Esquire, Enigma, Flora, Little Flora, Nirvana, Purl, Contoura, Cobble, Canaletta, Nexus, Koral)
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/ Sika/ Pedelite/ Rouf)/ white cement complete at all level as specified and directed. CERAMIC : Executive range-2 (Sizes 600 mm x 600mm and above)
Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department).
Preparing the RCC surface in roof slab, chajjas, terraces, sunken slabs, septic tank, OH tank, raft slab, walls etc. by thoroughly cleaning with wire brush etc. followed by power washing for making the surface absolutely free from any foreign particles like dust, oil, grease etc. and allowing surface to dry complete as directed at all levels.
Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: (i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/ mixed with cement in the ratio 1:2 as a prime coat. (ii) 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals) @ 15% by weight of cement. (iii) 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals) mixed with cement in the ratio 1:2 as final coat.
Grading roof for water proofing treatment with CC of nominal mix 1:2:4
Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately). 1.60mm thick sheet : Size 125mm x 60mm (Double rebate)
Supplying, fitting and fixing 30mm thick flush door (single leaf finished) made of phenol bonded Duratuff exterior grade (both side) plain medium density fibre board using 4 nos of hinges 125mm long ensuring that the hinges are not fixed less than 150mm from the edges with 8 nos. parallel sunk fully threaded screws 38mm long, should be used for fixing the hinges to the flush door after drilling a pilot hole 2.50mm dia 40mm long . Screws should not be hammered . Lock, tower bolts etc. necessary. 30mm thick. : Both side teak.
Supplying and installing uPVC- Fixed Windows made out of Lead free green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with galvanized steel 1.5/2mm including glazing bead , grooving bead, drain cap, fisher screws, packing pieces, necessary stainless steel screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of Silicon sealant from inside / outside of dowcorning / GE or equivalent. With 5mm clear glass (a) Fixed window using uPVC sections of size 58mm x 52mm x 2.4mm thick wall for frame and 58mm x 68mm having 2.4mm thick wall for glass sash having reinforcement of 1.5mm thick in both frame & sash. (WINSTA KOMMERLING/ FINESTA/ ENCRAFT)
Supplying and installing uPVC- Sliding Windows made out of Lead free green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass (a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash having 1.5mm thick reinforcement, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FINESTA/ ENCRAFT)
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. Ornamental grill : Fixed to Brickwork/ P.C.C/ R.C.C.
Structural steel work in sigle sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint (up to 4.6m height) from plinth level including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. In M.S. angles, channels, Tees etc.
Providing, fitting and fixing aluminium curtain wall on the exterior face of building fitting to concrete member by drilling hole fixing by brass screw fabricated with coloured anodised aluminium section of approved brand of size 101mm x 44.50mm by providing aluminium jointing angles including providing 6mm thick coloured reflectory type glass fitted with aluminium at all levels. (6mm clear glass)
Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Extra over for every subsequent coat of wall painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Applying priming coat over new wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt,dust and other foreign matter sand papering and slopping. Surfaces over 100mm in width or girth. High gloss purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Extra for every subsequent coat of paint. Surfaces over 100mm in width or girth. High gloss purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt,dust and other foreign matter. Surfaces over 100mm in width or girth. High glossy purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Extra for every subsequent coat of paint. Surfaces over 100mm in width or girth. High glossy purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished) (i) Sliding door bolts - 300mm x 16mm
(ii) Tower bolts (300mm x 12mm)
(iii) Door handles (150 mm)
(iv) Mortice lock vertical type - 100mm (Godrej with handle (6 lever)
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing cast in-situ manually driven reinforced cement concrete piles of using required grade of cement concrete of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings. Reinforcement to be measured and paid seperately as per item no. 21.4.1 Concrete grade M25 : UNIFORM PILE Pile Dia 500 mm - Upto 10 M
Concrete grade M25 : UNIFORM PILE Pile Dia 400 mm - Upto 10 M
Providing cast in-situ manually driven reinforced cement concrete piles of using required grade of cement concrete of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings. Reinforcement to be measured and paid seperately as per item no. 21.4.1 Concrete grade M25 : UNIFORM PILE Pile Dia 500 mm - Above 10 M
Concrete grade M25 : UNIFORM PILE Pile Dia 400 mm - Above 10 M
Extra for using admixture & plasticiser RCC grade M25 : Pile Dia 500 mm
Extra for using admixture & plasticiser RCC grade M25 : Pile Dia 400 mm
Extra for boring specified diameter pile in high sub-soil water level requiring use of drilling mud and extra cement 500 mm dia
Extra for boring specified diameter pile in high sub-soil water level requiring use of drilling mud and extra cement 400 mm dia
Empty boring for specified dia. Piles from ground level to cut-off level. 500 mm dia pile
Empty boring for specified dia. Piles from ground level to cut-off level. Pile Dia 400 mm
Demolishing R.C.C./ P.C.C. pile head of different diameters carefully without disturbing the remaining portion of the pile including opening out of the pile head to be demolished by excavating the earth upto required depth and clearing the debris as directed.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc) TMT bar made of Primary producer (From Primary producer)
Initial test for test loading to 2 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
Routine test for test loading to 1.5 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Supplying and planting of Dahlia / Chrysanthemum / Gladiolus on the ground ( bed planting, bed size 45 cm x 45 cm x 45 cm) including the preparation of the soil, providing organic manure and fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed .
Supplying and planting of suitable plant materials for preparation protective / external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed . ADOPTING SINGLE ROW PLANTING METHOD With Duranta
Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned) With Aeirides Using earthen pot of 30 cm dia.
Supplying and planting of palms with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned)
Drilling wilh drill bit in overburden portion of soil formation including collection of soil sample at every 3.0 m depth wherever there is a change of strata in sample boxes with distinguishing marks upto the depth of rock formation and withdrawing the drill bit for lowering caslng as directed with 245mm to 300 mm dia drill bit.
Casing / sinking / lowering of 200 mm dia MS pipe including cost of pipe and labour charge for casing , welding of joint by welding machine and sinking by drilling rig in portion all complete as directed by Department
Drilling with drilllng rid using D.T.H. in all kinds of rock formation including collection of sample at every 3.0 m depth of boring or wherever there is a change of strata in sample boxes with distinguishing marks upto a required depth of boring along with breaking rock fracture for desired discharge, withdrawing drilling rod and finishing the borehole by ramming upto a reqired dia upto the bottom and washing the well as per direction of the department all complete including testing of yield and drawdown of SWL of the DTW in presence of Engineer / incharge with submission of all report and lithology of the well as directed by the Department.
Casing/ sinking/ lowering of 150mm dia MS pipe including cost of pipe and labour charges.etc.
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. PVC : 40mm
Supplying fitting and fixing ISI approved PVC filter 3.00 metre long.
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Flushing, clearing, washing and watering of the tube well
Providing fitting and fixing Vitreous china Dual Flush / Floor Mounted Coupled / Extended water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) Jaquar make - White Opal (Cat. No. OPS-WHT-0310) (inclusive of seat cover and fittings)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. Jaquar Make - White Compact (Cat.No.URS-WHT-0701)
Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately. Nirali - Glister Super (Bowl Size - 535 x 432 x 200) Glossy
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. Jaquar Make - Continental (Cat.No.ACN-1331N)
(i) Continental 300mm for Providing, fitting and fixing CP towel rail complete as directed and specified. (Jaquar make) (i) wash basin (Cat.No. ACN-1101N)
(ii) Continental 600mm (Cat.No. ACN-1111N)
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. Jaquar Make - 32mm (HT/FT) (Cat.No.ALD-705 / 709)
Providing fitting and fixing Decorative Mirror complete as directed and specified. Jaquar Make - Swivel Mirror (Cat. No.ACN-1195N)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or in trenches. (i) 110mm dia.
(ii) 75mm dia.
Concealed by breaking brick wall/C.C/R.C.C, and making good to the damages. (i) 110mm dia.
(ii) 75mm dia.
Supplying fiting and fixing 87.5 degree PVC bend of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or in trenches. (i) 110mm dia.
(ii) 75mm dia.
Concealed by breaking brick wall/C.C/R.C.C, and making good to the damages. (i) 110mm dia.
(ii) 75mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or in trenches. (i) 110mm
(ii) 75mm dia.
Concealed by breaking brick wall/C.C/R.C.C, and making good to the damages. (i) 110mm dia.
(ii) 75mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/Prince) or ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or in trenches. (i) 110mm
(ii) 75mm dia.
Concealed by breaking brick wall/C.C/R.C.C, and making good to the damages. (i) 110mm
(ii) 75mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or in trenches. (i) 110mm
(ii) 75mm dia.
Concealed by breaking brick wall/C.C/R.C.C, and making good to the damages. (i) 110mm
(ii) 75mm dia.
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or in trenches. (i) 110mm x110 mm
(ii) 75 mm x 75 mm
Concealed by breaking brick wall/C.C/R.C.C, and making good to the damages. (i) 110mm x110 mm
(ii) 75 mm x 75 mm
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or in trenches. 110mm x75 mm
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. (i) 110mm
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (i) 110mm dia. PVC cowel of ISI make
(ii) 75mm dia. PVC cowel of ISI make
Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. (i) 100mm dia
(ii) 75 mm Dia
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole coverand frame of 19 Kg. Weight complete as directed and specified.
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. Exposed on walls Using Tata (medium) (i) 50mm dia. (Medium)
(ii) 32 mm dia (Medium)
(iii) 20mm dia. Using Tata (medium)
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. Concealed by chiselling or breaking brick wall/C.C/R.C.C, and making good to the damages. (i) 50mm Dia. Using Tata (medium)
(ii) 32 mm dia (Medium)
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified.. Concealed on walls 20mm dia. Using Tata (medium)
Supplying fiting and fixing C.P. bib cock 15mm dia of approved brand directed and specified.(G.I. & C.P. pipes will be measured seperatly) Jaquar make Continental /Clarion (i) Standard
(ii) C.P.2-way bibcock with wall flange
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Continental / Clarion Jaquar make 15mm dia
Supplying fiting and fixing C.P. pillar cock of 15mm dia approved brand and size as mentioned below as directed and specified. Jaquar make Continental, Pillar cock (ISI) / Pillar cock
Supplying fiting and fixing C.P. chrome plated (C.P.) shower 15mm dia of approved brand and size as mentioned below as directed and specified.(G.I. & C.P. pipes will be measured seperatly) Jaquar make - Continental Telephone shower 2-in-1 shower with massage effect with 1.5m PVC tube and swinging wall hook.
Supplying fiting and fixing C.P. chrome plated (C.P.) basin mixer complete as directed and specified.(G.I. & C.P. pipes will be measured seperatly) Jaquar make - Continental / Clarion Central hole basin mixer without popup waste system with 450mm long copper pipes and brass nuts Cat No. 167
Supplying fiting and fixing gun metal country pit valve (full way valve) I.S.I make as specified and directed. (i) 50mm dia
(iii) 20mm dia
Supplying fiting and fixing ball valve as specified and directed. 20mm dia. (gun metal/Copper)
Supplying fiting and fixing gun metal check valve including necessary threads to pipes as specified and directed. 50mm dia (Heavy type)
Supplying fiting , fixing and placing in position plastic cylindrical vertical closed top (PCVC) tank of Sintex/Polycon/Patton make over the staging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes complete as directed. 2000 litre capacity (Sintex make)
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe (IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) (i) 150 mm dia
(ii) 100 mm dia
(iii) 80 mm dia
(iv) 65 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc.complete with all fittings (butt welded) viz flanges, bends, tees, elbows, reducers etc including excavation (upto 1.5 m) (i) 150 mm dia
(ii) 80 mm dia
Providing, Erection, Testing & Commissioning of Cast Iron Sluice Valve/ Gate Valve confirming to IS:14846/2000 complete with matching flanges, rubber insertion, nuts, bolts and washer etc of following size complete as required. (MAKE:KOLEY/KALPANA/AUDCO) (i) 150 mm dia
(ii) 100 mm dia
(iii) 80 mm dia
Supplying & Fixing Cast iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd. (Make:Koley/Kalpana/Audco) b) 150 mm dia
d) 80 mm dia
Supplying & Fixing,cast iron body Butterfly Valves with matching flanges, rubber insertion, nuts, bolts and washer etc (IS:13095) of following size complete as reqd. (MAKE:KOLEY/KALPANA/AUDCO) (i) 150 mm dia
(ii) 80 mm dia
Providing ,Fixing,Testing & Commissioning of G.M. Stop Valve ISI Marked screwed type tested to 30Kg/cm2 pressure as per IS:778-1984 of following sizes complete as reqd. (i) 50 mm dia
(ii) 25 mm dia
Providing, erection testing, Commissioning of Cast Iron Foot Valve/ Strainer confirming to IS:4038/1538 complete with flanges, nuts, bolts and washer etc as required 150 mm dia
Providing,Fixing, testing &Commissioning of Single Headed Gun Metal ISI Marked oblique pattern Hydrant Landing Valve with 80 mm dia, flanged inlet & 63 mm dia instantaneous type female outlet complete with cap and chain, twist release lug and all accessories
Providing RRL Hose with ISI Marked (IS:636) 63 mm dia X15 M long complete with instantaneous type Gun Metal 3 mm dia ISI Marked male & female couplings (IS:903) bound & riveted to hose pipes with copper rivets and copper wire complete as reqd. ( MAKE: NIR
Providing & Fixing of Gun Metal 63 mm dia Short Branch Pipe with 20 mm dia nozzle, ISI marked (IS:903) complete as required. (Make: ESSEL/ WINCO/ NEWAGE).
Supplying, Installation, Testing & Commissioning of First Aid Hose reel drawn with 30 Mtrs. Long rubber hose and G.M shut off nozzle, 25mm dia Gate valve, Union pipe complete set confirming to IS: 884.
Providing, Fixing,Testing & Commissioning of air Release Valve a) 25 mm dia
b) 40 mm dia
c) 50 mm dia
Providing,erection testing & commissioning of pressure gauge 100 mm dia (0-10Kg/cm2)
Providing, erection,Testing & Commissioning of Pressure Switch (MAKE:INDFOSS)
Supply, Installation, Fixing of CARBON DIOXIDE Fire Extinguisher confirming to IS: 2878 with ISI Mark.(4.5 LITERS) BRAND: FIRESTOP / FIREND / FIRESHIELD
Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built – In pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle As per IS:13849 with ISI mark (05 kg capacity) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supplying , Installatiion, Testing and Commissioning of Electric Driven Main Fire Pump suitable for automatic operation and consisting of following complete in all respect as required. a) Horizontal type, single stage, centrifugal, end suction pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 b) Suitable HP squirrel cage induction motor, TEFC, 2900 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 class protection for enclosure, horizontal foot mounted type c) M.S Fabricated Common base plate, coupling, couping guard, foundation bolts etc as required. d) Suitable cement concrete foundation duly plastered with anti vibration pads e) 2280 LPM, 70 Mtr HEAD
Supplying, Installation, Testing and Commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of following complete in all respect as a) Horizontal type, single stage, centrifugal, end suction pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq. b) Suitable HP, 1500 / 1800 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12/24 volts electric starting c) One 200 Ltr capacity day oit storage tank fabricated from 3mm thick M.S Plates. Tank shall be provided with inlet, outlet, overflow, air vent, drain connections, filling connection & lever d) M.S. Fabricated Common Base plate, coupling, coupling guard, foundation bolts etc. as required. e) Suitable cement concrete foundation duly plastered with anti vibration pads f) 2280 LPM, 70 Mtr HEAD
MOTOR DRIVEN JOCKEY PUMP (SYSTEM AUTO PRESSURISATION PUMP) Supplying , Installatiion, Testing and Commissioning of Electric Driven Pressurisation Pump suitable for automatic operation and consisting of following complete in all respect as a) Horizontal type, single stage, centrifugal, end suction pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal at specified flow of the following capacity b) Suitable HP squirrel cage induction motor, TEFC, type suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 class of protection for enclosure, horizontal foot mounted type c) M.S Fabricated Common base plate, flexible rubber coupling, couping guard, foundation bolts etc as required. d) RPM : 2900 e) Suitable cement concrete foundation duly plastered with anti vibration pads f) 180 LPM, 70 Mtr HEAD
Supplying , Installatiion, Testing and Commissioning of 500 ltrs capacity PVE Priming tank for fire Pump Priming. Supplying , fabrication of M.S. Structral materials for Priming tank .
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete. (a) Short point up to 3.00 metre. length.
(b) Medium point up to 6.00 metre. Length.
(c) Long point up to 10.00 metre. Length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. (a) With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
(b) With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
(c) With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. (a) With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
(b) With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian make) (a) 40A
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35/36 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens make) 400 A
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (Richa, Bentec, Adhunic, V-Guard make) 6 way TPN (4+18) double door
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager, Crabtree xpro make) 25A
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager, Crabtree xpro make) 6 to 32A
Supplying with fitting and fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) including making necessary connection as per direction of department.
Supplying with fitting and fixing of 16 amp one way modular clip in switch with LED, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting and fixing of 6 amp one way modular clip in bell push MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 100 watt electronic modular 4 step speed control 2 - module type
Supplying including fitting and fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [ without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make) Energy efficient 5-star 1200 mm sweep Fusion 5 star (Havells or equivalent make)
Supplying including fitting and fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt. as required complete and as directed by the Department. Domestic Ventilator RX 150 mm sweep (ORIENT make), Brisk Air 150 mm sweep Louvre type (Crompton make)
Supplying, fitting fixing of LED Batten tubes high quality aluminium extruded with decorative end caps connection with 1.5 sq mm 1 Core PVC insulated round copper conductor as required and as directed by the deptt. BN021C LED 20 S PSU CW GR S2
Supplyingfitting and fixing of LED Bulb non-dimmable in the existing batten//angle holderas required and as directed by the department (Jaquar or eqvt. Make) Prima series bulb 14W
Supplying, installation, testing and commissioning of the following indoor Decorative Recessed mounted 2'x2' LED down lighter luminairesofmodel no.-RC380 B LED 36S-6500 G4 L60 PSD OD WH OC/ RC380 B LED 36S-6500 G4 L60PSD OD WH OC/LCTRS-36-TL/LCTRS-36-CDL/IO2830RPOO/IO2840RP/IO2850RP00 complete with all accessories such as ballast, starter etc. In the false ceilingtype Armstrong/Gypsum or similar ceilingmounting with necessary support with 1.5 sq mm P.V.C. insulated S.C copper conductor as required and as directed by the department. (Philips/ Crompton/ LT make)
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. (a) 4-5 module type Metal
(b) 10 module type Metal
(c) 12-16 module type Metal
(d) 24 module type Metal
Supplying including fitting and fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department. (a) 5 module
(b) 10 module
(c) 16 module
(d) 24 module
Supplying with fitting and fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt 5 Kg and Charcoal 96 Kg in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supply, fitting & fixing 20 mmx3 mm Copper strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of Brass Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt. with earth electrode copper strips and Lightning Arrestor etc. as specified and directed by the deptt.
Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid Copper tube having 85 mm dia. single prong at top and 3 mm thick base plate at bottom complete with fitting & fixing with Brass nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt.
Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/ CCI/ Polycab/ Gloster/ Finolex make) 4 Core, 2XWY 2XFY (a) 16.00 Sq. mm.4 Core U.G. armoured cable
(b) 35.00 Sq. mm.4 Core U.G. armoured cable
(c) 70.00 Sq. mm.4 Core U.G. armoured cable
Supplying with fitting and fixing of Single Phase Modular Motor Starter switch of the following specification complete including making necessary connection as specified and directed by the deptt. Overload Relay Range 16 - 25 Amps in 3 Module
Supplying including and fixing of following Moulded PVC boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface system complete as per direction of department. 1-3 module Surface Moulded PVC boxes
Supplying including fitting and fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department. 3 module
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Supplying with fitting and fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUS make) (a) 4.0 KVA Automatic Input 90-280 V Out put 200-240 V
(b) 5.0 KVA Automatic Input 90-280 V Out put 200-240 V
(c) 10.0 KVA Automatic Input 90-280 V Out put 200-240 V
Supplying with fitting and fixing of 25A Modular Motor Starter 2M , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Fully Automatic citation Star delta Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) for 13 - 20 A 3 to 15 HP motor.
Supplying with fitting and fixing of Angle iron framing made 50 mmx50 mmx5 mm size angle iron for accommodation of 1.00 Ton to 2.00 Ton Window/split type A.C. Machine
Copper pipe including cable fitting ( 1/4, 1/2, 5/8)
Supplying with installation testing and commissioning of Hi -wall split (Cordless remote) air conditioner of the following capacity complete with indoor and outdoor unit, copper pipe and electrical connection up to 5 m between the room unit and out door unit as directed by the department. Approved make Carrier, Hitachi, Diakin, Mitshubishi. Warranty: Company will have to provide warranty on the entire product for twelve months from the date of commissioning. Additional warranty on Rotary & Scroll Compressor will be four and two years respectively. Service: Three free services will have to be provided by the company apart from the breakdown calls, if any. (a) 1.5Ton 3 star inverter split Air Conditioner Machine
(b) 2.Ton 3 star inverter split, with R-32/R410 gas) Daikin FTKM71 or equivalent
Supplying with installation testing and commissioning of Ceiling Mounted Cassette inverter split (wired/ wireless Remote controller) air conditioner of the following capacity complete with indoor and outdoor unit, copper pipe and electrical connection up to 5 m between the room unit and out door unit as directed by the department. Approved make Carrier, Hitachi, Diakin, Mitshubishi. Warranty: Company will have to provide warranty on the entire product for twelve months from the date of commissioning. Additional warranty on Rotary & Scroll Compressor will be four and two years respectively. Service: Three free services will have to be provided by the company apart from the breakdown calls, if any. 4.0 Ton Cassette AC
Supplying installation, testing and commissioning of 10 passenger (680 Kg.)/ lifts having contract speed of 1 MPS serving different floors in the lift shaft as per detailed specification enclosed and as under: 1) No. of Elevators :1 No; 2) Type : Passenger Elevator; 3) Capacity Passenger : 10 Persons - 680 Kg; 4) Speed : 1.0 Metre/Sec (approx.); 5) Type of Drive : Variable Voltage Variable Frequency Drive with Microprocessor based Simplex Full Collective Control; 6) Location of Machine Room : Machine room less; 7) Available Travel : 10.8 Metres.(maximum); 8) Serving : Ground Floor to 5th Floor [6 Stops 6 Levels 6 Openings]; 9) Well Size (Required) : 1950 mm Wide x 2050 Deep over the finished surface; 10) Power Supply : 415 V three-phase 50 cycles AC; 11) Auxiliary Required Single -phase 220 V 50 cycles AC; 12) Car Size (Clear Inside) : 1300 mm Wide x 1350 mm Deep approx; 13) Required Pit Depth : 1600 mm (mandatory); 14) Required Head Room : 4800 mm; 15) Car Enclosure : Stainless Steel Car hairline finish; 16) Flooring : PVC Flooring; 17) Electric Light : Fluorescent Light Fittings; 18) Fan : 300 mm sweep 1 No; 19) No. of Entrances : One, Location - Front; 20) Car Entrance : Centre opening stainless steel power door with vision panel; 21) Landing Entrance : Centre opening stainless steel power door with vision panel; 22) Clear Opening : 800 mm Wide x 2000 mm High; 23) Indicators : Car & Landings Direction & Position Indicator; 24) Other Features : Battery Operated Emergency Alarm and Light. Call registration LEDs, OSG Electronic Switch, Fire drive. 2 Intercom System Full length Infra-red Door Safety, Auto Rescue Device.
Supplying installation, testing, programming and commissioning of Audio equipment,12 analog mic/line input, 8 analog output, networked signal processor with fault‐tolerant bus
Supplying, including Installation , Testing , Commissioning & Programming of In ceiling speaker as per Technical specification In ceiling speaker , Driver size - 8 inch , Frequency Range (-10 dB): 50 Hz – 16 kHz ; Coverage : 90° conical ; Sensitivity (2.83V@ 1m) : 97dB(1kHz-8kHz) ; Nominal Driver Impedance: 8 Ohms ; Driver Power Capacity: 25 watt ; 70V/100V Transformer Taps: 6 W, 3 W, 1.5 W, (0.75 W at 70 V only)
Supplying installation, testing, programming and commissioning of Audio equipment, 4 Channel Power Amplifier, 125 W per channel @ 8 ohms
Supplying, including Installation , Testing , Commissioning & Programming of Table POP up cable Management System as per Technical specification Durable pneumatic movement and mechanical latching mechanism, built-in Extender video and audio line driver , One female 15-pin HD connector and 3.5 mm mini stereo audio jack, Two CAT 6 RJ-45 network/ data/ phone connectors; unswitched AC outlet, Two CAT 6 RJ-45 network/data/phone connectors; unswitched AC outlet, Compact size with square bezel
Supplying, including Installation , Testing , Commissioning & Programming of Full HD 3D Plasma as per Technical specification 3D Panel ; Screen Size Diagonal (inches) : 50 Inches ; Aspect Ratio 16:9 ; Number of Pixels 2,073,600 (1,920 x 1,080) ; Panel G15 Progressive Full-HD NeoPlasma ; HDTV Display Capability (1080p, 1080i, 720p) ; 24p Playback (3:2)/24p Smooth Film ; 3D 24p Cinema Smoother ; 2D-3D Conversion ; Number of Speakers Front speaker (8 train speakers) x 2, Woofer (¿80 mm) x 1; SD Card ; USB ; Digital Audio Output (Optical) ; with wall mount
3 KVA On-Line UPS System (Orion or equivalent make as approved by the Deptt.) with PWM-IGBT technology 230V AC Input (160V – 280V A 1 Ph input- 1 Ph output With Isolation Transformer 2.4KW output with 0.8 output PF 30 min backup using SMF battery
Supplying installation, testing, programming and commissioning of Audio equipment,XLR Speak on Cable 4 pole connection
Supplying installation, testing, programming and commissioning of Audio equipment, Single Shielded multipair cable , 8 Core , Jacket - PVC black, ø 0.13 in (number
Supplying installation, testing, programming and commissioning of Audio equipment, High flexible Speaker cable for power amplifiers up to 4000 watts , Jacket - PVC, ø 0.37 in, black ,Conductor resistance = < 1.42 Ohm /1000 ft , Conductor - Stranded bare copper cables, 25x38 AWG (24AW
Supplying installation, testing, programming and commissioning of Audio and video equipment, 4200 Lm XGA Installation Projector , 2000:1 Contrast Ratio , Native XGA Resolution: RGB: 1024x768 pixels Video: 750 TV lines , 3D Gamma Correction
Supply, installation, testing & commissioning of 2 Loop Intelligent / Analogue Addressable Fire Alarm Panel Microprocessor based character display Network option built in Alarm, Trouble & supervisory relays LPCB listed. make : HONEYWELL, MORLEY IAS or equivalent as approved by the Deptt.)
Supply, installation, testing & commissioning of 5 Loop Intelligent / Analogue Addressable Fire Alarm Panel Microprocessor based character display Network option built in Alarm, Trouble & supervisory relays LPCB listed. make : HONEYWELL, MORLEY IAS or equivalent as approved by the Deptt.)
Supply, installation, testing & commissioning of Addressable Base Model - Detectors, LPCB approved, make - HONEYWELL, MORLEY IAS or equivalent as approved by the Deptt.)
Supply, installation, testing & commissioning of intelligent plug in photo electric Smoke Detectors having features like integral communication, dual LED for 360° viewing angle, walk test with address display etc. UL / LPCB approved, make : HONEYWELL, MORLEY IAS, or equivalent as approved by the Deptt.)
Supply, installation, testing & commissioning of intelligent plug in Thermal Detectors having features like integral communication, dual LED for 360° viewing angle, walk test with address display etc. UL / LPCB approved, make :HONEYWELL or equivalent as approved by the Deptt.)
Supply, installation, testing & commissioning of Control Module.UL / LPCB approved, make - Honeywell , MORLEY IAS or equivalent as approved by the Deptt.) with housing box Model:200e-SMD.
Supply, installation, testing & commissioning of Addressable Hooter / SOUNDER complete with control module.UL / LPCB approved, make - HONEYWELL, MORLEY IAS, or equivalent as approved by the Deptt.)
Supply, installation, testing & commissioning of Manual pull station with addressable interface, built in LED with key reset facility. UL / LPCB listed. make : HONEYWELL, MORLEY IAS or equivalent as approved by the Deptt.)
Supply & fixing of 2 x 1.5 sq. mm. PVC insulated copper Armoured Cable on surface/ recess/ above false ceiling etc. as required. (ISI marked) )
JC Construction Pvt Ltd
HATIMURIA DEVELOPERS PVT.LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid