Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.8 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹45.1 L+₹1.2 L (2.80%)Rejected-Finance R O 218 05 OPP J D A COMPLEX TRIKUTA NAGAR JAMMU J K PIN 180020 | JAMMU | JAMMU AND KASHMIR | 180020 | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹46.0 L+₹2.1 L (4.72%)Rejected-Finance H O WANI HOUSE II SHOWPORA SRINAGAR J K | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹47.9 L+₹4.0 L (9.08%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹48.4 L+₹4.4 L (10.1%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
25 Sept 2024, 6:00 pmClosed
GE 865 EWS
GE 865 EWS PIN-913 865 C/o 56 APO
REPAIR REPLACEMENT INSULATION OF INTERNAL WATER PIPE LINE INSULATION OF WATER TANK PUFF TANK AND ALLIED WORKS UNDER AGE BR II OF GE 865 EWS
2024_MES_671100_1
865/EWS(NIT-62)/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
Yes
GE 865 EWS
₹82,000
Yes
3 Dec 2024
3 Sept 2024
1 Oct 2024
3 Sept 2024
25 Sept 2024
18 Sept 2024
Amount
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting if requeired reconnecting and refixing in position of capacity execeeding 250 ltrs and not exceeding 500 litres, including cleaning and removing all scale and dirt etc from mouths of circulating pipes etc, complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tank (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 500 litres, Iincluding dismantling of water tanks and remove to store, complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting if requeired reconnecting and refixing in position of capacity execeeding 500 ltrs and not exceeding 1000 litres, including cleaning and removing all scale and dirt etc from mouths of circulating pipes etc, complete all as specified and directed.
S &F Rotational moulded high-quality Polyurethane Foam (PUF) insulated water storage tank (cylinderical vertical with closed top) with Insulation thickness of 50 mm and density of puf minimum 40 kg/cu.m, with unique self-locking lid with hexa bolts hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 litres Iincluding dismantling of water tanks and removing to store and including all accessories, complete all as specified and directed.
S &F Rotational moulded high-quality Polyurethane Foam (PUF) insulated water storage tank (cylinderical vertical with closed top) with Insulation thickness of 50 mm and density of puf minimum 40 kg/cu.m, with unique self-locking lid with hexa bolts hoisted and fixed in position all as specified in SSR Part-I of capacity 500 litres Iincluding dismantling of water tanks and removing to store and including all accessories, complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tank (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 litres Iincluding dismantling of water tanks and removing to store and including all accessories, complete all as specified and directed.
S&F 25 mm bore 3 layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stablised and antimicrobial fusion welded having thermal stabilty for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fitting fixed complete to walls, ceiling or floors including taking up or down steel tubing 25mm to 32mm bore including cleaning for refixing or removal to store complete all as specified and directed.
S&F 25 mm bore PP-R Gate valves (brass insert) as per requirement of the site fixed to PPR pipes complete all specified and directed.
M & L for Providing 100mm thick Insulation to 500 ltr water tank complete all as specified and directed with inclusion of following items/material as per standard engineering practice and method:- (i) Nitrile sheet 19mm (ii) Rock wool (iii) Wire mesh (iv) Polythene (v) Cello tape (vi) Aluminum sheet 28 gauge
M & L for Providing 100mm thick Insulation to 1000 ltr water tank complete all as specified and directed with inclusion of following items/materials as per standard engineering practice and method:- (i) Nitrile sheet 19mm (ii) Rock wool (iii) Wire mesh (iv) Polythene (v) Cello tape (vi) Aluminum sheet 28 gauge
M & L for 50mm thick insulation to water pipe line of 20/25/32 mm dia complete all as specified and directed with inclusion of following items/materials as per standard engineering practice and method:- (i) Export quality heat tape (ii) Aluminum tape (iii) K. Flex 19mm (iv) Rock wool (v) Wire Mesh (vi) Polythene (vii) Cello tape (viii) Aluminum sheet 28 gauge
Schedule of Credit
M/S ZTECH (BID ID -3111895)
M/S WEB COMPNAY (BID ID -3102252)
M/S LEO TRADERS (BID ID -3104394)
national engineering (BID ID -3102176)
RND ENGINEERS & CONTRACTORS (BID ID -3113038)
M/S NANCY ENTERPRISES (BID ID -3113205)
M/S UNITED CONSTRUCTION CO. (BID ID -3113267)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .