Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance AZAD ROLLING SHUTTERS AND CONSTRUCTION MOHAN CINEMA ROAD OPPOSITE J P MARKET KOTA RAJASTHAN 324006 | KOTA | RAJASTHAN | 324006 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance TUTICORIN | TUTICORIN | TAMIL NADU | 626202 | Not Admitted-Fee/PreQual/Technical/Finance Others-EMD payment not received. |
Tender Value
₹39.7 L
EMD Value
₹79,440
Closing Date
11 Mar 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
General Manager
Zirconium Complex Pazhayakayal
Supply and Installation of UPVC Ventilators, Windows and Doors in various plant buildings at Zirconium Complex, Pazhayakayal, Tuticorin -628152
2023_NFC_742637_1
ZC/NFC/CIVIL/797/2023
Open Tender
Civil Works
Item Rate
183 days
Zirconium Complex Pazhayakayal
Please refer tender documents
7 documents required · 7 mandatory
₹0
₹79,440
Yes
14 Mar 2023
3 Mar 2023
14 Mar 2023
3 Mar 2023
11 Mar 2023
6 Mar 2023
180 days
Amount
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. 4mm thick Acrylic should be provided in the louvers. The ventilator should be fixed to the wall with 100% packing with SS screws and silicon packing all round the frames & screws, complete and as directed by Engineer-in-charge.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with multi point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or clear glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with SS screws and silicon packing all round the frames & screws, complete and as directed by Engineer-in-charge.
Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The Door should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving MS electroplated screws into plug.
Dismantling existing damaged/corroded louvers, windows and doors at various heights, including fixtures carefully without damaging the existing structure, cleaning, staking of unserviceable material within a lead of 50mts and transporting the same upto a lead of 2km, unloading and stacking in the location , complete and as directed by Engineer-in-charge.
Transportation of dismantled louvers, windows and doors, carriage of debris by engaging tractor trolley including cost of fuel, wages of driver and required manpower for loading, transporting upto a lead of 2kms, unloading and staking the same in the location complete and as directed by Engineer-In-Charge.
Proving and fixing double scaffolding system ( cup lock type ) for heights upto 25m made with 40mm dia. M.S. Medium class tube 1.5m centre to centre, horizontal and vertical tubes joining with cup height made with 40mm dia. M.S. tubes, M.S. jallies/ Aluminium planks for working platform, M.S. clamps etc., in the scaffolding for working platform and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened by proving cross/diagonal bracings, runners, connection with the building/permanent structures with regular intervals vertically and horizontally etc., whenever required for inspection of work at required locations with essential safety features for the workmen such as hand rails, toe board etc., complete as per direction and approval of Engineer-in-charge.
AZAD ROLLING SHUTTER AND CONSTRUCTION
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .