| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.5 L+₹1.7 L (3.64%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹49.4 L+₹3.5 L (7.74%)Rejected-Finance 14 3RD CROSS ASHWATHNAGAR RMV 2ND STAGE SANJAY NAGAR POST HEBBAL BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹52.9 L+₹7.0 L (15.4%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
Tender Value
₹43 L
EMD Value
₹46,000
Closing Date
15 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE ARMY BANGALORE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
ADDN/ALTN TO BLDG NO P 140 (MULLAH HALL) AT SELECTION CENTRE SOUTH UNDER GE (SOUTH) BANGALORE
2022_MES_507905_1
86109/E8
Open Tender
Construction Works
Item Rate
90 days
BANGALORE
AS PER TENDER
7 documents required · 7 mandatory
₹500
Yes
GE (SOUTH) BANGALORE
₹46,000
Yes
HQ CWE ARMY BANGALORE
12 May 2022
14 Feb 2022
22 Mar 2022
14 Feb 2022
15 Mar 2022
1 Mar 2022
14 Feb 2022 - 21 Feb 2022
22 Feb 2022
60 days
Amount
B/R Schedule 'A'
Dismentling Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified & directed by Engr-in-Charge.
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells cesspits, manholes, pier holes etc n.exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil, complete all as specified and directed.
All as per item No. 1.03 here in before but exc 1.5 and n.exc 3.00 m deep
Returing and filling in of excavated soil including , spreading , levelling,waterring and well remming in layers are not exceeding 25 cms each.
Removal of surplus soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point.
Moorum/red bajri filling in floors or pavings, laid in layers n.exc 15 cm thick, spread, levelled and rammed including watering, complete all as specified and directed
Taking down Chowkhats or frames exc. 1.5 sq. m but n. exc 4 sqm with shutters (without taking off shutters from the frames) complete all as specified and directed .
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete,complete all as specified and directed .
Reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs under reamed piles and mass concrete,complete all as specified and directed .
Reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in columns etc, complete all as specified and directed .
Reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in lintel, roof beams etc. complete all as specified and directed .
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (anealed) not less than 0.9 mm dia or securing with clips,complete all as specified and directed .
All as per item above here in before but 8 mm dia and over, in stiruups
M&L for rough finished concrete surfacs of formwork to sides of flat concrete foundations, footings, based of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter,complete all as specified and directed .
M&L for rough finished concrete surfacs of formwork to sides of pillars, posts, struts, piers columns etc complete all as specified
M&L for rough finished concrete surfacs of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed .
M&L precast cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in block masonry with solid blocks, exc 10 cm in width and setting in mortar complete 1:4.complete all as specified and directed .
Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 including finished even and smooth without using extra cement,complete all as specified and directed .
Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement with wpc@ 3% by wt of cement. Note: WPC will be measured and paid sepratily
Supply only integral wate proofing compound ISI Marked as approved, all as specified and as directed .
Preparation of new plastered surfaces of walls and applying two coats of White wash complete all as specified and as directed.
Preparing new plastered surfaces of walls and applying two coats of Cement Based paint over a coat of exterior primer complete all as specified and as directed.
Complete removal of existing treatment of walls and applying one coats of Cement Based paint over a coat of exterior primer complete all as specified and as directed.
M & L hardcore of broken stone or boulders of gauge n.exc 63mm deposited spread and leveled in layer n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
75 mm thick plain cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate), as in sub base of floors, complete all as specified and as directed.
25 mm thick plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), as in sub base of floors finished even & smooth, complete all as specified and as directed.
S&F coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over 15 mm thick screed bed in cement mortar 1:6,complete all as specified and as directed.
S&F coloured Glazed ceramic tile in verticle surface 350 x 250 x7 / 450 x350 x7mm set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick screed bed in cement mortar 1:6,complete all as specified and as directed.
MS steel work in tubular trusses including special shaped washer etc., complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240,complete all as specified and as directed. Note : Tubular truss work for curved galvallume sheet shall be executed after approval of accepting officer. Quoted rate shall be inclusive of this aspect. Nothing extra shall be payable on this account.
S&F rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee, angle channel or flat sections) including distance pieces, cleats etc., Conforming to Fe-410-W (Gde-E-250) quality-A,complete all as specified and as directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-410-W (Gde-E-250) quality-,complete all as specified and as directed.
Preparation of new or previously untreated steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enemel paint over a coat of red oxide primer,complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws etc. ,complete all as specified and as directed. Note : Roof shall be curved and sheet work shall be executed only after approval of its design alongwith design of tubular truss by accepting officer. Quoted rate shall be inclusive of this aspect. Nothing extra shall be payable on this account.
S&F chequered cement concrete tiles 20 cm x 20 cm x 25 mm / 30 cm x 30 cm x 25mm thick with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors over 20 mm thick screed bed in cement mortar 1:6,complete all as specified and as directed..
S&F 11 to 15 diameter of neck mild steel screw bolts (machine made ) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square but length of bolt exc 10 cm but n.exc 15 cm long,complete all as specified and as directed..
Labour only for holes drilled dia of holes exc 12mm and n.exc 25mm and depth of holes exc 3mm but n.exc 12mm,complete all as specified and as directed..
Techno T-Grid Ceiling suspension system of main runner size 32mm x 24mm x 3600mm, Cross Tee size 27mm x 24mm x 1200mm & 27mm x 24mm x 600mm, wall Angle of size 22 mm, 20mm, 3050 mm, sheet thickness 0.30 mm, providing and fixing Techno Acoustic Mineral Fibre Square mineral tesured tiles suspension system, panels shall be of size 600mmx600mm x 12mm having noise reduction co-efficent 0.4-0.6 light reflection over 85 relative humidity 95% Grid system for fixing ceiling tiles shall comprise of Techno T-Grid suspension system, The 24 mm main Tee runner shall be suspended at an interval of 1200 mm centre. The 1200 mm cross tee shall be attached between to main runners at every 600 mm and further 600 mm cross Tee shall be interconnected between two 1200 mm cross tees. Thus a grid system of 600mm x 600mm is formed. The main tee shall be suspended by mean of 2/2.5 mm wire or 4 mm G.I. rod from slab/roof. The suspension shall be provided at 1200 mm centre to centre and not more 450 mm from the wall. However, the suspension shall not be more than 150 mm distance from the spliced joints of the main tee, complete all as specified and as directed
M&L for 2nd class hard wood clean sawn in as in scantling framed and fixed to walls with screws etc all as specified and as directed.
Supply and fix Bonded mineral wool blanket slab made from glass density 24kg/cum and fixed as per maker's instructions, 25mm thick complete all as specified and as directed
S&F 12 mm thick Pre-laminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with invisible screws to timber frame work etc complete all as specified and directed.
M&L 2nd class hard wood plain fillets, square, rectangular or trinagular in section, clean sawn, secured with nails or brads, sectional area n.exc 3 sqcm, complete all as specified and directed.
M&L 2nd class hard wood plain fillets, square, rectangular or trinagular in section, clean sawn, secured with nails or brads, sectional area exc 3 sqcm but n.exc 6 sqcm, complete all as specified and directed.
Preparing new or previously untreated wood and wood based surface of any description, under 10 cm in width or girth and applying two coats of synthetic varnish ovar a coat of wood filler liquid transparent, complete all as specified and directed.
S&F powder coated aluminium frame for doors, windows vetilators with one of more rebates including joining cleat for fixing etc, complete all as specified and directed.
S&F powder coated aluminium window and ventilator shutters, side hung type without sash, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150 mm long (1 no.) hinges type B-21 100 mm long ( 2 nos) suitable handles (1 no.) complete all as specified and as directed. .
S&F 4.0 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane , complete all as specified and as directed. .
S&F aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with aluminium wire staples, complete all as specified and as directed. .
S&F powder coated aluminium door shutters, aluminium section weighing 0.55 Kg/mtr including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges powder coated aluminium snap beading screws etc and include one number floor spring with each shutter complete all as specified and as directed.
M&L in repair 9 mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations fixed with screws to aluminium door shutters complete all specified & as directed.
S&F 5.5 mm thick tinted sheet glass and glazing with aluminium beading & rubber gasket in square in each panes including hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed.
S&F double action type floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty. (ISI Marked) complete all specified & as directed.
S&F 4 levers brass mortice lock vertical type size 100 mm complete all as specified. (ISI Marked)
E/M Schedule 'A'
M&L for point wiring in concealed with PVC insulated, unsheathed, single core multistandard copper conductor cable( FRLS) of size 1.5 Sqmm, 1100 volts grade including 1.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through in and including PVC conduit medium grade ISI marked with its acessories & pressed steel terminal boxes and providing 3 mm thick ISI marked laminated sheet cover and brass screws with cup washers for fixing switches / socket / regulators etc including all necessary wall cutting chases and making good disturbed surfaces in cement mortar 1:3 for One light/CB point controlled by one switch, complete all as specified and as directed.
All as per item No 2.01 here in before but for one 3 pin 5 Amps socket outlet point on independent board complete all specified & as directed.
All as per item no 2.01 here-in-before but with cable 2.5 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket point,complete all specified & as directed.
M & L switch piano, flush type single pole, one way 5 Amps complete all specified & as directed.
M&L switch socket combination 2 in 1, 3 pin 5 Amps flush type universal complete all specified & as directed.
M&L switch socket combination 2 in 1, 3 pin 15 Amps flush type universal omplete all specified & as directed..
S&F MCB single pole, 240 volts 6 to 32 Amps,complete all specified & as directed.
S&F MCB single pole and neutral 06 to 32 Amps, 240 Volts,complete all specified & as directed.
MCCB 4 pole, 415 V, adjustable type , 160 Amps with breaking capacity 36 KA with sheet metal enclosure complete all as specified and as directed.
S&F VTPN MCCB 250A DB-Double door made out of CRCA mild steel sheet flushed in wall, TPN 12 way with 200 Amps rated bus bar , 415 volts IP-54, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc, complete all as specified and as directed.
Supply & Fix recess mounted 36 watt 2'X2' extruded aluminium housing with milky diffuser recess mounting ultra slim LED panel integrated electronic driver of operating voltage 110 to 265 Volts of complete with all accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size 24/0.2mm and taking down old unserviceable tube light fitting complete all as specified and as directed . Make: C&S Cat No : LTCRSLM36WATT2X2/ Bajaj Cat No BCTBLR-36W LED FP CW / Crompton Cat No LCPL-36-CDL(2x2) or its equivalent in Philips/Jaguar/Wipro
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long including protection pipe 15mm dia light grade and watering pipe by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe wire mesh and lugs, including testing and complete all as directed.
Supply and spread river sand to required width at bottom and top for cable cushioning all as specified and as directed (8cm before laying cable and 15cm after laying the cable and punned into 18cm thickness). Note: Punned thickness only shall be measured and paid.
Supply and lay burnt bricks of class 'B' laid dry across in trenches for cable protection complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and as directed..
Supply and fix wall split AC 2 Ton Capacity units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating including Copper Cube, brackets etc complete all accessories and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 170V to 250 V with output voltage stabilized at 230 V with accuracy (+) or (-) 2.5% and capacity 5 KVA complete all as specified and as directed.
M&L sub main wiring concealed type with Four runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) including earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Three runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 volts, complete all as specified and directed.
OM CONSTRUCTIONS
M/s SL CONSTRUCTION
SAI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .