| 1 | L1₹6.6 LAccepted-AOC T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | L1 | Accepted-AOC Found reasonable for acceptance | |
| 2 | L2₹7.1 L+₹38,877 (5.76%)Rejected-Finance H NO 190 S 4 CHODANKAR RESIDENCY NEAR GANPATI TEMPLE CENTRAL HORTA AQUEM BAIXO NAVELIM SALCETE GOA 403707 | SOUTH GOA | GOA | 403707 | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹8.1 L+₹1.3 L (19.8%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹10.5 L+₹3.7 L (55.6%)Rejected-Finance 340 11 M S NATIONAL ENGINEERING CORP 340 11 SATTI STREET ROORKEE ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | L4 | Rejected-Finance L1 being accepted |
Tender Value
₹10.0 L
EMD Value
₹19,980
Closing Date
23 Sept 2023, 6:00 pmClosed
GE (P) Navy Mandovi
GE (P) Navy Mandovi Military Engineer Services INS Mandovi
As per tender documents
2023_MES_615164_1
8511/E8 GE (P) NAVY MANDOVI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Mandovi
As per tender documents
8 documents required · 8 mandatory
₹500
GE (P) Navy Mandovi
₹19,980
Yes
15 Dec 2023
23 Aug 2023
29 Sept 2023
23 Aug 2023
23 Sept 2023
8 Sept 2023
23 Aug 2023 - 7 Sept 2023
Amount
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc to match existing surface complete all as specified and directed.
M & L for point wiring complete with 1.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including casing and caping of suitable size, with all accessories, on wall/ ceiling, sunken switch / terminal box 1.12 mm thick, suitable for 3mm thick laminated hylem sheet or plastic masonite laminated sheet top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 1.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for one light point or fan point controlled by one switch complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
All as per item No 2 here-in-before but for one 5 Amps switch socket combination on independent board complete all as specified and directed.
M & L for point wiring complete with 2.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including casing and caping of suitable size, with all accessories, on wall/ ceiling, sunken switch / terminal box 1.12 mm thick, suitable for 3mm thick laminated hylem sheet or plastic masonite laminated sheet top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 2.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for 15 Amp switch socket combination complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
M & L for point wiring complete with 1.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, concealed in wall drawn through and including PVC conduit of suitable size, with all accessories, on wall/ ceiling, sunken switch / terminal box 1.12 mm thick, suitable for 3mm thick laminated hylem sheet or plastic masonite laminated sheet top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 1.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for one light point or fan point controlled by one switch complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
All as per item No 5 here-in-before but for one 5 Amps switch socket combination on independent board complete all as specified and directed.
M & L for point wiring complete with 2.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, concealed in wall drawn through and including PVC conduit of suitable size, with all accessories, on wall/ ceiling, sunken switch / terminal box 1.12 mm thick, suitable for 3mm thick laminated hylem sheet or plastic masonite laminated sheet top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 2.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for one 15 Amps switch socket combination on independent board complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
S & F in repairs switch piano flush button single pole one way 5-6 Amps complete all as specified and directed.
S & F in repairs switch piano flush button single pole two way 5-6 Amps complete all as specified and directed.
S & F in repairs bell push, flush button type single pole 5-6 Amps complete all as specified and directed.
S & F in repairs switch socket combination 2 in 1, 6 pin and 5 Amps, flush type complete all as specified and directed.
S & F in repairs switch socket combination 5 in 1, 6 pin and 15 Amps, flush type complete all as specified and directed.
S & F in repairs modular switch 1 way 6A, 1 module complete all as specified and directed.
S & F in repairs modular socket 6A, 2/3 pin 2 module complete all as specified and directed.
S & F in repairs modular bell push 6A, 1 module complete all as specified and directed.
S & F in repairs modular socket 6/16A, 2/3 pin 2 module complete all as specified and directed.
S & F in repairs modular fan regulator, step type, min 120 watt, 2 module complete all as specified and directed.
S & F in repairs sheet metal enclosure metal clad plug and socket 20 Amps complete all as specified and directed.
S & F in repairs concealed/surface fitting sheet metal enclosure for MCB's (D.B), double door, SPN 4 way with suitable rated bus bar, 240 Volts, complete all as specified and directed.
S & F in repairs concealed/surface fitting sheet metal enclosure for MCB's (D.B), double door, SPN 8 way with suitable rated bus bar, 240 Volts, complete all as specified and directed.
S & F in repairs concealed/surface fitting sheet metal enclosure for MCB's (D.B), double door, TPN 4 way with suitable rated bus bar, 415 Volts, complete all as specified and directed.
S & F in repairs MCCB distribution board (DB), vertical, double door, TPN 4 way, with suitable rated bus bar including MCCB, 125 Amps, 4 pole 16 kA alongwith connections complete all as specified and directed.
S & F in repairs concealed/surface fitting sheet metal earth plug and socket, single pole and neutral with two pin including one single pole MCB 20 Amps 240 Volts complete all as specified and directed.
S & F in repairs ceiling rose, surface bakelite, 65 x 50 mm, two to three terminals complete all as specified and directed.
M & L for earthing complete with steel earth plate electrode 60cm x 60cm x 6.3 mm thick buried directly in ground, vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plate not less than 1.5 mtr below ground level connected to GI earth wire 4mm dia by means of bolts, nuts, check nuts and washers etc including 15mm dia protection pipe upto 7.5m length, connecting the earth lead to earth connection in the main distribution box with lugs and GI nuts, bolts etc as shown on electrical plate No 3 of SSR part 1 including neccessary excavation in disintergrated hard rock, filling earth upto 15 mm thick and providing earth pit, 20mm dia GI funel, PCC earth chamber, 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing including taking out old earthing complete all as specified and directed.
S & F in repairs fan regulator, electronic step type on existing laminated sheet complete all as specified and directed.
M & L for submain wiring with two runs of 4 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 4 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including 25mm/32mm wide PVC casing and caping with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion including taking down old submain wiring complete all as specified and directed. Note: Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire and one run of PVC casing and caping shall be measured as unit run.
M & L for submain wiring with two runs of 4 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 4 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including 25mm dia PVC conduit with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion including taking down old submain wiring complete all as specified and directed. Note: Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire and one run of PVC conduit shall be measured as unit run.
M & L for submain wiring with four runs of 6 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 6 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including 25mm/32mm wide PVC casing and caping with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion including taking down old submain wiring complete all as specified and directed. Note: Four runs of 6 Sqmm cable, one run of 6 Sqmm earth wire and one run of PVC casing and caping shall be measured as unit run.
S & F in repairs call bell, ding dong, 240 volts complete all as specified and directed.
S & F in repairs MCB SP 6 to 32 Amps, 240 Volts, 'C' series, complete all as specified and directed.
S & F in repairs MCB SPN 6 to 32 Amps, 240 Volts, 'C' series, complete all as specified and directed.
S & F in repairs MCB, four pole 63 Amps, 415 Volts, 'C' series, complete all as specified and directed.
S & F in repairs MCCB 3 pole 63 Amps, 415 Volts for 3 phase 50 Hz, 16 kA breaking capacity, Ics=Icu= 100% with thermal, magnetic and microprocessor adjustable type, complete all as specified and directed.
S & F in repairs lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings including fixing of 01 x 9 W LED lamp, warm white, inverter type, complete all as specified and directed.
S & F in repairs three pin plug top, 5 Amps complete all as specified and directed.
S & F in repairs three pin plug top, 15 Amps complete all as specified and directed.
S & F in repairs LED ceiling light fitting, recessed/ surface mounted, square/ round type, 18 W, warm white, complete with all accessories including driver and internally pre-wired complete all as specified and directed.
S & F in repairs PVC surface gang box (switch box), 1 module, including screws and all fittings complete all as specified and directed.
S & F in repairs PVC surface gang box (switch box), 2 module, including screws and all fittings complete all as specified and directed.
S & F in repairs PVC surface gang box (switch box), 3 module, including screws and all fittings complete all as specified and directed.
S & F in repairs PVC surface gang box (switch box), 4 module, including screws and all fittings complete all as specified and directed.
S & F in repairs PVC surface gang box (switch box), 6 module, including screws and all fittings complete all as specified and directed.
S & F in repairs PVC casing capping of size 20 x 12 mm, of heavy grade including all fittings complete all as specified and directed.
S & F in repairs PVC casing capping of size 25 x 15 mm, of heavy grade including all fittings complete all as specified and directed.
S & F in repairs PVC square blocks including fixing screws complete all as specified and directed.
Supply only electrical insulation tape rolls, best quality locally available, complete all as specified and directed.
S & F in repairs LED light fittings, upto 20 watt, warm white light, for 230 volts 50 Hz AC supply, decorative box type with driver, holder etc including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Sagar Constructions
Shree Ayyappa Engineering
NATIONAL ENGINEERING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .