Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.3 LAccepted-Finance | ₹67.3 L | L1 | Accepted-Finance Lowest Tenderer |
| 2 | L2₹69.6 LAccepted-Finance 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | ₹69.6 L | L2 | Accepted-Finance Second Lowest Tenderer |
| Sl No | Description | Qty | Unit | rv electricals L2 | SETHARAM ELECTRICAL AND CONSTRUCTION L1 |
|---|---|---|---|---|---|
| 1.00 | Supply , Erection , testing and commissioning and handing over of 1No 250KVA Diesel Generator set of 0.8 P.F, Three Phase 415 Volts, 50 C/S, 1500 RPM 300 BHP as detailed below. With Automatice main failure .
1. Dry type Air cleaner
2. Expansion bellow
3. Radiator, Radiator for and mounting
4. Air to Air charge cooler
5. Exhaust Gas turbo charger
6. Lube oil cooler and Lube oil filter
7. Fuel filter (per and Micro)
8. In-Line Mono-block fuel injection pump with gove fuel feed pump
9. Electronic governor
10.24V Battery charging alternator
11. 24V Volt electric starter motor
12. Engine test certificate
13. Residential muffler.
14. Fly wheel with starter ring
Engine instrument panel mounted
Engine control panel consisting of ON/OFF/START Key Lube oil pressure gauge, Oil
Temperature gauge electronic hour meter and RPM indicator. | 2 | Set | 29,50,000 ₹59 L | 28,50,000 ₹57 L |
| 1.012.BASE FRAME: Base frame should be fabricated in sheet metal. The base frame is rugged in construction and designed for mounting engine and brush less alternator closely coupled with cross members mounted on AVM. The base frame should have the provision for mounting of acoustic enclosure on it. The supply of Gen set includes loading Unloading and transportation charges. 1. 1 No AC Ammeter 2. 3Nos Current transformers with suitable ratio 3. 1No Ammeter Selector Switch 4. 1No AC Voltmeter 5. 1No Voltmeter Selector switch 6. 1No Frequency Meter 7. 1No KWH Meter 8. 1No Power factor Meter 9. 1No KW Meter 10. Battery charging set comprising of the following for charging the battery from mains. | |||||
| 1.02a. Transformer/ Rectifier b. DC Ammeter c. Charging rate selector switch d. DC Voltmeter e. Circuit breaker f. Voltage Regulator g. ON/OFF Switch. 11. 1 Set DC control relays incorporating engine start stop and failure to start/Lockout 12. 1 Set Selector switch auto/ manual 13. 1 No Push button “Start” 15. 1 No Push button ”Stop” 16. 1 No Push button ”Reset” 17. 1 No Signal lamp for indicating load on mains 18. 1 No Signal lamp for indicating load on set 19. 1 No Signal lamp for indicating set fails to start 20. 1 No Signal lamp for indicating set running 21. 1 No Signal lamp for indicating Battery charger ON | |||||
| 1.0322. 1 Set Pilot lamps of 3 Nos 23. MCCB of 800A capacity with magnetic thermal over lead release, instant start circuit trip and under voltage release switch 24. Rectangular copper bus bars(1 No for each phase, neutral and earthing terminal) of adequate capacity duty color coded with heat shrinkable PVC sleeves. 25. 1 No Mains Voltage monitor 26. 1 Hooter/ Audio Alarm for D G O/L 27. 1 Set Timers 28. Audio and visual indication arrangements for a. Low Lubricating Oil pressure b. High water temperature c. Over speed 29. 1 No Earth fault relay 30. Isolator to Isolate the neutral NOTE: 1. The control panel should be complete with Necessary fuses , cables, labels, other accessories with Isolation 2. The engine should trip for the following conditions a. Low Lubricating Oil pressure b. High water temperature c. Over speed | |||||
| 1.044.ACOUSTIC ENCLOSURE: Acoustic enclosure shall be powder coated and Fabricated of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Critical processes of punching are done on CNC Machines to maintain dimensional accuracy of hole within 0.1 mm. Powder coating done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE RETARDANT 64Kg/m density Mineral wool of 100mm Thickness as acoustic material. Four hinged doors shall be provided to canapy. The average sound level at 1Mt. distance shall be less than 75 DBA average or as per CPCB norms. | |||||
| 1.05Surface Treatment – Painting: The enclosure surface shall be suitably treated for degreasing degreasing and posphating. The canapy are passed through seven- tank treatment thoroughly. Additional features of Canopies: Canopy fabricated on CNC machines dimensional Accuracy of 0.1mm so as to increase its durability. Special designed supporting rips/ structures are used in canopies so as to give sturdiness and to reduce the Vibrations of the DG sets if any. World class Cooling Package: Canopies shall have Cooling package for which it can also perform at 45 deg c/ ambient temperature No grouting required on the ground only a level surface capable of withstanding the ground, only a level surface capable of withstanding the DG weight. | |||||
| 1.06Lifting hooks shall be provided for the acoustic Enclosure, which should be unloaded independently of the DG Set. The Gen set frame shall also be provided with hooks for unloading. Temperature rise inside the canopy Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at air cleaner within 5-7 deg centigrade. 6.FUEL TANK: 460Ltrs. Removable fuel tank shall be fabricated out of 14SWG CRCA MS sheet and is part of base frame. It is duty painted and fitted with inlet and outlet connections and mechanical fuel gauge. Fuel tank can be easily removed for cleaning or any maintenance. 7.BATTERY: 2 Nos 12 V 180 AHR battery. With 12 V, 15a Output Battery Charger with Boost and Trickle charge facility. The Generator Set Should be erected on the existing generator bed with all precaution testing and commissionning the Generator with load running for 8hours with intial charging. the tes certificate and the warranty certificate should be issued at the time of commissioning. | |||||
| 2.00 | GST @ 18% | 1 | Nos | 10,62,000 ₹10.6 L | 10,26,000 ₹10.3 L |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
20 Feb 2026, 3:00 pmClosed
The Superintending Engineer, PWD.,
O/o. The Superintending Engineer, PWD., Buildings (C and M) Circle-1, Chepauk, Chennai-5
Improvements by providing 2 Nos. 250 KVA Diesel Generator Set for NKM Building, Secretariat, Chennai-09
2026_PWD_656031_1
PWD/BCMC1/121/2025-26
Open Tender
Electrical Works
60 days
NKM Building Secretariat
Refer Tender Documents
8 documents required · 8 mandatory
₹0
₹44,000
24 Feb 2026
17 Feb 2026
20 Feb 2026
17 Feb 2026
20 Feb 2026
17 Feb 2026
Supply , Erection , testing and commissioning and handing over of 1No 250KVA Diesel Generator set of 0.8 P.F, Three Phase 415 Volts, 50 C/S, 1500 RPM 300 BHP as detailed below. With Automatice main failure . 1. Dry type Air cleaner 2. Expansion bellow 3. Radiator, Radiator for and mounting 4. Air to Air charge cooler 5. Exhaust Gas turbo charger 6. Lube oil cooler and Lube oil filter 7. Fuel filter (per and Micro) 8. In-Line Mono-block fuel injection pump with gove fuel feed pump 9. Electronic governor 10.24V Battery charging alternator 11. 24V Volt electric starter motor 12. Engine test certificate 13. Residential muffler. 14. Fly wheel with starter ring Engine instrument panel mounted Engine control panel consisting of ON/OFF/START Key Lube oil pressure gauge, Oil Temperature gauge electronic hour meter and RPM indicator.
22. 1 Set Pilot lamps of 3 Nos 23. MCCB of 800A capacity with magnetic thermal over lead release, instant start circuit trip and under voltage release switch 24. Rectangular copper bus bars(1 No for each phase, neutral and earthing terminal) of adequate capacity duty color coded with heat shrinkable PVC sleeves. 25. 1 No Mains Voltage monitor 26. 1 Hooter/ Audio Alarm for D G O/L 27. 1 Set Timers 28. Audio and visual indication arrangements for a. Low Lubricating Oil pressure b. High water temperature c. Over speed 29. 1 No Earth fault relay 30. Isolator to Isolate the neutral NOTE: 1. The control panel should be complete with Necessary fuses , cables, labels, other accessories with Isolation 2. The engine should trip for the following conditions a. Low Lubricating Oil pressure b. High water temperature c. Over speed
4.ACOUSTIC ENCLOSURE: Acoustic enclosure shall be powder coated and Fabricated of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Critical processes of punching are done on CNC Machines to maintain dimensional accuracy of hole within 0.1 mm. Powder coating done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE RETARDANT 64Kg/m density Mineral wool of 100mm Thickness as acoustic material. Four hinged doors shall be provided to canapy. The average sound level at 1Mt. distance shall be less than 75 DBA average or as per CPCB norms.
Surface Treatment – Painting: The enclosure surface shall be suitably treated for degreasing degreasing and posphating. The canapy are passed through seven- tank treatment thoroughly. Additional features of Canopies: Canopy fabricated on CNC machines dimensional Accuracy of 0.1mm so as to increase its durability. Special designed supporting rips/ structures are used in canopies so as to give sturdiness and to reduce the Vibrations of the DG sets if any. World class Cooling Package: Canopies shall have Cooling package for which it can also perform at 45 deg c/ ambient temperature No grouting required on the ground only a level surface capable of withstanding the ground, only a level surface capable of withstanding the DG weight.
Lifting hooks shall be provided for the acoustic Enclosure, which should be unloaded independently of the DG Set. The Gen set frame shall also be provided with hooks for unloading. Temperature rise inside the canopy Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at air cleaner within 5-7 deg centigrade. 6.FUEL TANK: 460Ltrs. Removable fuel tank shall be fabricated out of 14SWG CRCA MS sheet and is part of base frame. It is duty painted and fitted with inlet and outlet connections and mechanical fuel gauge. Fuel tank can be easily removed for cleaning or any maintenance. 7.BATTERY: 2 Nos 12 V 180 AHR battery. With 12 V, 15a Output Battery Charger with Boost and Trickle charge facility. The Generator Set Should be erected on the existing generator bed with all precaution testing and commissionning the Generator with load running for 8hours with intial charging. the tes certificate and the warranty certificate should be issued at the time of commissioning.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_791550.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
BOQ_791550.xls
BOQ • 0.28 MB
DGGenSetSchdlCond.pdf
Tender Documents • 0.82 MB
Download all tender documents and submit your bid