Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance PULWAMA JAMMU KASHMIR 192301 INDIA UDYAM JK 15 0009614 | PULWAMA | JAMMU AND KASHMIR | 192301 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹39,180
Closing Date
27 Aug 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RNB Electric Division Sgr
Executive Engineer RNB Electric Division Sgr
Internal Electrification of Block No. (L) at Pampore Flats
2022_PWDJK_184654_1
E/NIT/84/2022/23dtd20/08/2022
Open Tender
Electrical Works
Item Rate
Internal Electrification of Block No. (L) at Pampo
as per BOQ
2 documents required · 2 mandatory
₹800
Executive Engineer RNB Electric Division Sgr
₹39,180
27 Aug 2022
20 Aug 2022
27 Aug 2022
20 Aug 2022
27 Aug 2022
20 Aug 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2 x 1.5 sq.mm (P+N) FRLS PVC insulated copper conductor single core cable of srandard make dully isi marked , to be laid in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box etc. as required. (excluding cost of conduit) but including cost of circuit wiring from DB to first switch in sub circuit.complete job
Supply and Fixing of two module stepped type Electronic Fan regulatot on the existing modular plate switch box including connectionsetc as required.
Supply ,installation ,testing and commissioning of 12 Watt Surface mounted Slim / Recessed type LED Fixtures of Standard make dully ISI marked .
Supply ,installation ,testing and commissioning of 12 Watt Batten Type Al Base LED Light Fixture of standard make as mirror lights of Standard make dully ISI marked .
Supply ,installation ,testing and commissioning of 1200 mm sweep Ceiling Fans complete in all respects.
Supply ,installation ,testing and commissioning of 250 mm sweep Shutter type Exhaust Fans complete.
Supply ,installation ,testing and commissioning of Bulk head fitting of standard make dully Isi marked ,incl p/f of 9 Watt LED Lamp of standard make
Supply and Fixing of Neon Indicator Modular Switch Series incl its Frame Plate, cover plate and G I Box of required size
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supply ,installation ,testing and commissioning of AC / DC Bells with its Batteries.
Supplying and fixing of following sizes of 2mm thick ,medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required for repairs or laying of additional conduits whereever required (25 mm dia)
Supplying and fixing of following sizes of 2mm thick ,medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required for repairs or laying of additional conduits whereever required (32 mm dia)
Point wiring for 10 Amp Socket out lets with 3x2.5 sq mm (P+N+E) FRLS PVC multistranded copper wire of standardmake dully isi marked in recessed or surface conducting system incl the cost of supplying and fixing modular grid plate mounted flush mounted 2 no 240 volts 6 amp 5 pin socket out let along with 16 Amp control Switch of approved quality and colour housed in zinc chromate passivity GI boxes with modular cover plate and inter connections complete as per specifications and as required ( Excl cost Of p/f of pvc Conduiting) complete job
Point wiring for 16 Amp Socket out lets ( Two out lets wired in one sub circuit ) with 3x4 sq mm (P+N+E) FRLS PVC multistranded copper wire of standardmake dully isi marked in recessed or surface conducting system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16 amp 6 pin combined shuttered socket out let along with 240 volt 16 Amp control Switch of approved quality and colour housed in zinc chromate passivity GI boxes with inter connection complete as per specifications and as required.( Two switched socket out lets shall be connected to one circuit. Both the out lets shall be measured an counted as one unit )excluding cost of conduits
Providing , laying of Wiring for submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable of srandard make dully isi marked,to be laid in surface/ recessed medium class PVC conduit as required
2 X 10 sq. mm + 1 X 10 sq. mm earth wire
Supplying and fixing of 18-24 Ways double door MCB distribution board of sheet steel, dust protected, duly powder painted, having fitted with tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
Supply ,installation ,testing and commissioning of (Single pole MCB) 5 A to 32 A rating, 240/415 V , "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 63 Amp (Double pole MCB) 240/415V, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A
Supplying and fixing 32 Amp 240/415V, 2 Module Change over Switch fitted in excisting D Box incl making of necessary connections
Design, Fabricataion, assembly, Installation, Testing and Commissioning of Front Operated Cubicle type compartmentalised as per form 3B free standing, dust and verim proof (IP 42 ingress protection) LT panel suitable for use of 415 volts, 3 Phase 4 wire 50Hz suitable for a fault levewl of 55kA at 415 volts, fabricated from 2 mm thick Powder coated paint finish of approved shade CRCA MS sheet with hinged, gasketted9 metal based neoprene) and lockable doors having structral reinforcement with suitable angle/ chanel/T / Flat section uncl gland plates as requiredand lifting hooks with sleeved TPN AL Busbars and G I strip of required size with 2 no earthinmg terminals complete with interconnections as required for MCB`s and control wiring. 24.1) Each incoming / out going breakers shall have thermal megeatic release. The panel will be made as oper detailed specifications and drawings formating part of this document. 24.2) Incomer :- 1 No 400 Amp TPN MCCB with beaking capacity 50 kA with thermal release and adjustable settings. 24.3) 1 Set of R,Y,B Phase indicating lamps. 24.4) 1 No MFM with 630/5CT coils 24.5) 1 Set of 500 Amp TPN Alluminum Bus Bar with colour coding sleeves 24.6) Out Going :- 16 No 63 Amp D Pole MCB`s 24.7) 4 No 32 Amp D P MCB`s 24.8) 1 no 40 Amp TPN MCB
Supply , laying , testing and commissioning of 185 mm sq. 3 ½ core Steel armoured Al Cable PVC insulated and sheathed ,including cost of thimbles on input and output side dully crimped with hydraulic tool including making of necessary connections complete job ,the cable is to be laid as per site requirement for service line
Supply , laying , testing and commissioning of 35 mm sq. 3 ½ core Steel armoured Al Cable PVC insulated and sheathed including cost of thimbles on input and output side dully crimped with hydraulic tool including making of necessary connections complete job ,the cable is to be laid as per site requirement fo for lift
Supply ,installation ,testing and commissioning of 63 Amps TPN MCB of standard make dully isi marked with sheet steel enclosure for housing of TPN MCB.
Chemical Earthing with 2 mts long GI electrode to 50 mm dia G I Pipe placed verticaly in 100 mm dia bore dully drilled with hand drill and filed with required quantatity of chemical and man hole cover at top. The job includes extending of Earthing fron Eart Electrode to Main L T panel and lift at top with 19 x5 mm G I Strip in one run
MIR ELECTRONICS
NUCLEON ELECTRICALS MECHNICAL AND SUPPLIERS
M/S GLOBAL SCIENTIFIC TECHNOLOGIES
stage.html
html • 0.02 MB
finance_466634.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .