S.E. E D C- MVVNL,Unnao
Superintending Engineer (EDC/UNNAO)
Quantum of work for construction of 11 KV line for G/S to seavrage Treatment plant MLD-04-350 KVA at Mohalla Ahmad Nagar (Near Pani ki Tanki Mann Bagiya) Katri Piper Khera (Shuklaganj), Gangaghat, Unnao. (Turnkey basis).
2023_MVVNL_853700_1
209/EDC/UNNAO/2023-2024
Open Tender
Miscellaneous Works
Turn-key
180 days
Unnao
AS PER TENDER DOCUMENT
2 documents required · 2 mandatory
₹3,540
A/C-No.3355002101008374,IFSC-Code-PUNB0335500
₹92,000
Yes
22 Nov 2023
19 Oct 2023
26 Oct 2023
19 Oct 2023
25 Oct 2023
19 Oct 2023
Amount
PART-A: Supply of Following materials (All taxes includes with GST)
S.T Pole 11 mtr long(duly Painted)
Pcc pole 8.5 mtr long
Stay set 16x1800 mm(Galvanized)
Stay wire 7/10 swg
Stay clamp with nut & Bolt(As per Respo Norms)
Earthing Rod 2540x20mm)
G.I.Wire 10 Swg
11 kv V-Type X-Arm(Galvanized)
F-Bracket
11 Kv Composit Poly.Disc Insulator 45 Kn (T&C Type)
11 kv Composit Poly.Pin Insulator
T-Off Channel(Galvanized)
Top Channel(Galvanized)
Dropper Channel(Galvanized)
S/S Base Angle(Galvanized)
X-Bracing Angle(ms Angle 50x50x6 mm)(Galvanized)
Stay Insulator
Holding Clamp for Pcc Pole
Holding Clamp for ST Pole
Cable Jointing Kit 3x185 Outdoor
Cable Jointing Kit 3x185 Indoor
Cable Jointing Kit 3x185 Statethrough
G.I Pipe 6" dia
ACSR Weasel Conductor.
11 KV XLPE Cable SIZE(3X185 mm2)
11 KV V.C.B(O/G) 200/100/5A 350A
Part- B : Work for Construction of line (Extra GST applicable as per Govt rules)
Errection of Single Pole (STP/Pcc) Structure including digging of pits fitting of all accessories alongwith Cartage and dragging from dump sit to pit Site.
Errection of double pole (STP/Pcc) Structure including digging of Pits fitting of all accessories alongwith cartage and dragging from dump site to pit site.
Laying of Stringing and Sagging of 11 KV line (3P 3W) by ACSR Weasel Conductor including all associted works and making clearnce of Road with Jointing Jumper and Binding on Insulator as Required.
Laying of 11 KV Cable Size 3x185 mm2 double Circuit and Drigging of Trunch 1050 mm deep 500 mm Vide including all Matterial (First Class bricks Cement Sand).
Heat Sinking and laying of 11 kv outdoor/indoor cable jointing kit xlpe cable size3x185 mm2 and all associted work as required(by high Pressure testing of cable with D.C.High Voltage will be arranged by the Contractor.
Heat Sinking and laying of 11 kv Straight through cable jointing kit xlpe cable size3x185 mm2 and all associted work as required(by high Pressure testing of cable with D.C.High Voltage will be arranged by the Contractor.
Earthing of Pole as per Respo Norms.
Grouting of Pole as per Respo Norms.
Digging of Pits fitting of Nuzzling and Grouting of Stay as per Respo Norms. With grouting Material.
Hosting of Cable on double Pole with G.I.Pipe 6'dia 3 mtr long with clamp.
Fixing of Installation of V.C.B.at control room and all associted works required(33/11 kv s/s Tribhuvan Khera).
Earthing of V.C.B.boring/electod type earthing all Material will be provided by Contractor.
Mounting of CT/PT Unit on double Pole with fitting of all accessories including connection of 11 kv cable CT/PT Unit to Metering Cubical
Fixing and Installation of 11 KV Pilfer Resistant metering cubical.
Katyani Construction Co.
Ludhiana Agencies (regd.)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .