Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹38.0 L
EMD Value
₹76,000
Closing Date
28 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE MEERUT
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
PROVN OF GUARD ROOM ALONGWITH TOILET BLOCK AT RA-16 (PINE ARTY OFFR MESS) OF 56 FD REGT UNDER GE (NORTH) MEERUT CANTT
2025_MES_732451_1
94270/MRT/2025-26/E8
Open Tender
Civil Works
Item Rate
180 days
MEERUT CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (NORTH) MEERUT
₹76,000
Yes
24 Sept 2025
24 Sept 2025
3 Nov 2025
24 Sept 2025
28 Oct 2025
9 Oct 2025
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc.and getting out in Hard/ Dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed.
Removing Excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M & L M-25 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns etc; basement slabs, under-reamed piles and mass concrete complete all as specified & directed.
M & L M-25 (using 20mm graded stone aggregate) for columns, pillars, piers, posts and struts complete all as specified & directed.
M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for TMT bars 6mm to 8mm dia and over as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L damp proof course 40mm thick in cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) to horizontal or v
M & L for applying 15 mm thick rendering using ready mix plaster bags in CM 1:4 on brick / concrete surfaces of external walls finished even and fiar, using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, complete all as specified and directed. Note:- Water proofing compound shall be measured and paid seperately
Supply only integral water proofing compound complete all as specified & directed.
M & L for 75 mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed
M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior emulsion over a coat of primer complete all as specified and directed.
M&L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, frame rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete all as specified & directed.
M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 and finished smooth and even in ceiling without ceiling using extra cement complete all as specified & directed.
Factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising of PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).
S & F 35 mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F 30 mm thick 2nd class hardwood glazed and skeleton window shutters rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc; sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.20(b); supplied and fitted in chowkats , but divided into squares, with plain, chamfered or roun ded, mitred and rebated sash bars, any numbers complete complete all as specified and directed.
S & F 3 mm thick Sheet glass, figured , pin headed and glazing with beadings in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
M&L for mild steel work in roof trusses,purlins,rafters,wind ties,crane gantries,posts,rails and fastenings and heavy bracket framing (Beam,Tee,Angle,Channel or Flat sections) including distance pieces,cleats etc complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
S&F 600mmx450mm bevelled edge looking mirror and fixed to wooden plug with CP brass screws and cup washers fixed on 6 mm thick AC Building board or commercial ply wood complete all as specified & directed.
S&F Soap dish,vitreous china white, approximate size 160x160x90mm fixed to plug with chromium plated brass screws complete all as specified and directed.
S&F MS plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, with fixing attachment,Fe-290(Gde E-165) complete all as specified & directed.
M&L for Sand filling under interlocking tiles or in foundations including watering and consolidation complete all as specified & directed.
Removing Excavated soil exceeding 250 M but not exceeding 500M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M&L for Cement concrete 1:2:4 in haunching and benching for manholes complete all as specified and directed
M&L for RCC work type B-1 1:2:4 (20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, in shelves and p
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness.(below or above ground level) Complete all as specified and directed.
One 3 pin 5/6 Amps socket outet point on independent board, controlled by one, one way 5/6 Amps switch complete all as specified and directed.
Surface channel in concrete 1:3:6 (40 mm graded aggregate) for drain including necessary formwork complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
S&F Modular Socket , 2 Module , 6A, 2/3 pin combined , AC, 240 V. ISI Marked and complete all as specified and directed.
S&F Modular Switch , 1 Module , 6A, AC, 240 V. one way ISI Marked and complete all as specified and directed.
One light/Bulb/ street light pointcontrolled by one, one way switches 5/6 Amps complete all as specified and directed.
Per Point
Supply & fix LED lamp 9 W 6500k,240V complete all as specified and directed.
S&F Modular Switch ,1 Module , 16A, AC, 240 V. ISI Marked and complete all as specified and directed.
M&L for point wiring with 2.5 Sqmm (nominal cross section area) single core, multi stranded PVC insulated, unsheathed copper conductor,FR, cable in and inrigid pvc conduit 20 mm dia or higher medium grade ISI marked complete with all PVC conduit accessories / fittings and sunk pressed (1.2 mm thick) steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, including earth wire continuous of PVC insulated, unsheathed 2.5 Sqmm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic laminated sheet screwed with brass screws, cup washers complete all as specified and directed for the following :- (a) One 3 pin socket outlet, 15 amps, with cables 2.5 sqmm size on independent board, controlled by one, one way 15 amp switch.
Supply and fix sheet metal enclosure single pole & neutral for 240 volts 8 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed.
S&F Modular Socket, 2 Module , 6A/16A, 2/3 pin combined , AC, 240 V. ISI Marked and as specified
Supply and fix MCB single pole 240 volt 6 to 32 amps 10 KA complete all as specified and directed.
S & F ceiling rose, surface type, bakelite, 65 x 50 mm, three terminal complete all as specified and directed.
S & F lamp holder insulated body with back plate fix done anodised 100 x 100 mm pressed steel box flush to the wall with 3 mm thick backlite cover complete all as specified and directed.
Supply & fixing LED tube light fitting T/5 surface mounting poly carbonate 240 volts 20 watts, 6500K complete all as specified & directed.
S&L XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area of 16 sqmm 2 core complete all as specified and directed.
Supply & fixing Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
S&F Isolator DP 40 Amp ,240 Volts, suitable for fixing in MCB DB 'C' series in DB complete all as specified and directed.
M/L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wite 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specifiied or indicated including testing on completion complete all as specified and directed.
M&L for Building security light fitting 1 x 35 LED type, drawn through and including GI bracket of size 25 mm dia bore light grade 1.4 mtr long, bend to shape including MS clamps made out of flat iron of size 32 x 4 mm - 02 Nos and necessary nuts, bolts, washer as required complete all as specified and directed.
S&F Exhaust fan, steel body AC single phase, 230V of size 300 mm sweep with blades,frame and louvers complete all as specified and directed.
Supply and fix Water heater storage type steel body with copper inner tank and heating element upto 2KW capacity 25 ltr, BEE 5 stared complete with a rating including providing of hold fast in wall and PVC connection 45 cm long with 15 mm dia brass union at both end heavy duty complete all as specified and directed.
Cutting of existing CI pipes and reducing to required length before laying in position for insertion of new tees,branches etc complete all as specified and directed of size 150mm dia bore. Note :- Fittings will be measured and paid foe separately under respective items.
20 mm dia bore complete all as specified and directed.
S & F Rotational moulded PVC water storage tanks 500 Ltrs capcity three layer (cylindrical vertical with closed top) hoissted and fixed in position with inlet, outlet & wash out pipe complete all as specified & directed.
M&L 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) finished fair and even as in sub base complete all as specified and directed.
All as per item No-1 here-in-before but depth exceeding 1.5 mtr wide and n. exc. 3 mtr complete all as specified and directed.
Each Set
M & L for Sand cushioning for under ground cable upto 8 cm before laying the cable and 15 cm after laying cable and then punned. After punning the thickness of sand cushioning should be 18 cm complete all as specified and directed. Note :- Only punned thickness shall be measured for payment.
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed heavy duty 1100 volts grade of size 16 sqmm, 4 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating and taking down the old unserviceable cable complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement complete all as specified and directed.
M&L for Providing cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in copings, platform, kerbs etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
50 mm dia bore complete all as specified and directed.
25 mm dia bore complete all as specified and directed.
Each Job
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement complete all as specified and directed.
M&L for Providing cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in copings, platform, kerbs etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
50 mm dia bore complete all as specified and directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
TD2.pdf
Tender Documents • 0.22 MB
TD1.pdf
Tender Documents • 0.41 MB
TD4.pdf
Tender Documents • 1.49 MB
BOQ_820090.xls
BOQ • 3.51 MB
TD3.pdf
Tender Documents • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .