| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹45.3 L+₹5.0 L (12.4%)Rejected-Finance H NO 496 SECTOR 10 GURGAON 122001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹46.8 L+₹6.5 L (16.1%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹47.8 L
EMD Value
₹95,560
Closing Date
13 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
PROVN OF 2XCOMBINED (LADIES AND GENTS) TOILETS BATHROOM URINAL POINTS AT STN POLYCLINIC OF IHQ OF MoD (ARMY) CAMP AND ADDN/ ALTN TO JCOs LIVING BLDG NO P-3 AT CAMS AND CERTAIN OTHER SANCTIONED WORKS UNDER AGE B/R-I (S) AND AGE E/M (S) OF GE (SOUTH)
2021_MES_476061_2
GE/DS-61/2021-22
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹95,560
Yes
29 Dec 2021
23 Oct 2021
15 Nov 2021
23 Oct 2021
13 Nov 2021
30 Oct 2021
24 Oct 2021 - 28 Oct 2021
60 days
Amount
Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed by Engineer-in-charge.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and directed by Engineer-in-charge.
M&L for removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for hard core of brocken stone or boulders gauge n.exc 63mm ,deposited , spread and levelled in layers n. exc ,15 cm thick , watered and rammed to a true surfaces , complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:5:10 Type E2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-charge.
M&L for damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick, in cement concrete 1:2:4 type B0 (using 1:2:5 mm graded stone aggregate) complete all as specified and directed by Engineer-in-charge.
M&L for rendering with readymix plaster 15mm thick (external walls) on fair faces of brick work or concrete surfaces finished even and smooth complete all as per manufacturer;s instructions and directed by Engineer-in-charge.( Make of ready mix plaste shall be Birla Aerocon/Ultratech readiplast/ACC Accoplast / Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE) Note:- 1. The readymix plaster shall be procured directly from the manufacturar or their authorised dealer. 2. The contractor shall produced original purchase voucher alongwith test certificate of readymix plaster while claiming RAR/ Final Bill.
M&L for rendering with readymix plaster 15mm thick (internal wall) on fair faces of brick work or concrete surfaces finished even and smooth complete all as per manufacturer;s instructions and directed by Engineer-in-charge.( Make of ready mix plaste shall be Birla Aerocon/Ultratech readiplast/ACC Accoplast / Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE) Note:- 1. The readymix plaster shall be procured directly from the manufacturar or their authorised dealer. 2. The contractor shall produced original purchase voucher alongwith test certificate of readymix plaster while claiming RAR/ Final Bill.
M&L for rendering with readymix plaster 5 mm thick on ceiling surfaces finished even and smooth complete all as per manufacturer;s instructions and directed by Engineer-in-charge( Make of ready mix plaste shall be Birla Aerocon/Ultratech readiplast/ACC Accoplast / Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE) Note:- 1. The readymix plaster shall be procured directly from the manufacturar or their authorised dealer. 2. The contractor shall produced original purchase voucher alongwith test certificate of readymix plaster while claiming RAR/ Final Bill.
M&L for Joint free Glazed Coloured Ceramic tiles in vertical surface 450x300x7mm/450X350X7 thick /set and joint in neat cement slury and pointed in white or colour cement to match over and including rendering 10mm thick in cement plaster 1:4 finished rough to receive tiles complete all as specified and directed by Engineer-in-charge.
M&L for 75mm thick cement concrete type D-2 1:4:8 using 40mm graded aggregate as in sub base to floor finished rough to receive finishes. complete all as specified and directed by Engineer-in-charge.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including screed bed or bedding layer of mortar 15mm thick in CM 1:6 complete all as specified and directed by Engineer-in-charge. Make: Somany/Orient/Kazaria or its equivalent
M&L for providing cement concrete 1:2:4 Type B1 using 20mm graded aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer-in-charge.
M&L for RCC 1:2:4 type B1 using 20mm graded aggregate in chajjas complete all as specified and directed by Engineer-in-charge.
M&L for RCC 1:2:4 type B1 using 20mm graded aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engineer-in-charge.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for square, rectangular or polygonal in rough finishes of concerete complete all as specified and directed by Engineer-in-charge.
M&L for formwork to sides and sofits of floor or roof beams, beam haunchings, griders, bressum-mers, lintels, cantilevers, shelves including supports overhangs, etc also splays between floors and beams etc complete all as specified and directed by Engineer-in-charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and directed by Engineer-in-charge.
M&L for form work to edges of concrete flats ,treads ,breaks in floors , window cills , concrete railings , opening in concrete walls ,floor and roofs n. exc 20 cm wide and sides of RCC / PCC bands in walls horizontal or sloping and similar work exc 10 cm but n. exc 20 cm wide ,as roughed finished surfaces of concrete complete all as specified and directed by Engineer-in-charge.
M&L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-charge.
M&L for mild steel TMT bars 5mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-charge.
M&L for RCC 1:1.5:3 type A1 (using 20 mm graded stone aggregate) as in footing , foundations and rafts complete all as specified and directed by Engineer-in-charge.
M&L for RCC 1:1.5:3 type A1 (using 20 mm graded stone aggregate) as in coloumn and piers posts etc complete all as specified and directed by Engineer-in-charge.
M&L for RCC 1:1.5:3 type A1 (using 20 mm graded stone aggregate) as in slab supported on wall beam and coloumn complete all as specified and directed by Engineer-in-charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be coloured with heat mould plain coloured PVC'C channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stills and plain colour PVC sheet for top rail lock and botton rail either side and as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading. And jointed together with solvent cement suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed by Engineer-in-charge.
S&F solid PVC doors & frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with 19mm MS square tube of 19 guage s&f in opening as per specification & drg in SSR 2004 Part II complete all as specified and directed by Engineer-in-charge.
S&F stainless steel of AISI 304 grade barrel tower bolt 200 mm long, extruded section, etc complete all as specified and directed by Engineer-in-charge.
S&F stainless steel of AISI 304 grade handle of size 200mm size long etc. complete all as specified and directed by Engineer-in-charge.
S&F 100mm size butt hinges stainless steel of AISI 304 complete all as specified and directed by Engineer-in-charge.
S&F vitreous china wash hand basin ,white ovel shape as per existing size fixed in position (excluding taps ,waste pipe chain and plug ) but including porcelain stopper and a pair of MS bracket etc complete all as specified and directed by Engineer-in-charge.
S&F basin mixture single hole ,single lever of brass CP connection hot and cold for 15 mm bore pipe complete all as specified and directed by Engineer-in-charge.
S&F Vitreous China, pedestal pattern (EWC) all as per catalouge Part No 20044 of Hindware or equivalent in cera, parryware as approved by GE white colour incl seat cover(Std) with PVC bolts, nuts etc complete all as specified and directed by Engineer-in-charge.
S&F PVC valveless , syphonic action type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm dia for low level complete all as specified and directed by Engineer-in-charge.
S&F looking Mirror 5.5mm thick bevelled edge oval shape of size 450x600mm having fixing arrangement complete all as specified and directed by Engineer-in-charge.
S&F Cast iron floor trap 75 bore including 75 mm round CP brass grating with round hole including jointing to waste pipe tmm out let dia CI floor trap incl jointing to waste pipe in run lead complete all as specified and directed by Engineer-in-charge.
S&F CI soil waste and vent pipes 100mm bore size sand cast in any length with or without ears with cement joints laid in floors complete all as specified and directed by Engineer-in-charge.
All same as per serial item No. 40 here-in-before but 75mm bore.
S&F cast iron bends any radius, dimishing pieces or traps 100mm bore size complete all as specified and directed by Engineer-in-charge.
S&F cast iron bends any radius, dimishing pieces or traps 75mm bore size complete all as specified and directed by Engineer-in-charge.
S&F in Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-charge.
S&F 15 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors or concealed, complete all as specified and directed by Engineer-in-charge.
S&F 20 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors or concealed, complete all as specified and directed by Engineer-in-charge.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-charge.
M&L for making sunk and half rounded for WHB or Sink in granite & sand stone s edges of stone both as required complete all as specified and directed by Engineer-in-charge.
M&L for making moulding granite stone on exposed edges not less than 40 mm thick by pasting granite stone strips up to 50 mm wide by adhesive for counter sunk wash hand basin top as approved design and polishing / granding complete all as specified and directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top),tripple layer white from out side, hoisted and fixed in position all as specified in SSR Part I of 500 ltr capacity with threaded type lid cover complete all as specified and directed by Engineer-in-charge.
S&F 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball ,screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-charge.
S&F gun globe or gate valve for 15 mm bore pipe with iron wheel had screwed both ends for iron pipe complete all as specified and directed by Engineer-in-charge.
S&F gun globe or gate valve for 20 mm bore pipe with iron wheel had screwed both ends for iron pipe complete all as specified and directed by Engineer-in-charge.
S&F galvanised iron tank nipple 15mm bore suitable for HDPE water tank complete all as specified and directed by Engineer-in-charge.
S&F Vitreous china bowl urinal flat back ,size of 465X355 X 265 mm white , complete inclding providing and fixing flugs ,bedding urinal against wall in cement motar 1:2 ,securing urinal to plugs with and including 60 mm long screws , pointing around urinal back in cement , fixing automatic flushing cistern with brackets flush pipe ,discharge pipe complete all as specified and directed by Engineer-in-charge.
S&F vitreous china urinal partition white of size 310x700mm complete all as specified and directed by Engineer-in-charge.
Excavating in post holes (or similar holes) each not exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface, work in soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
S&F 15mm chromium plated bib tap long body with flange fixed in 15mm bore of pipe, cast copper alloy with crutch of butterfly handle, screwed in iron pipe complete all as specified and directed by Engineer-in-charge.
S&F 15 mm angle stop valves (fancy type), cast copper alloy , chromium palted, screwed down high pressure witg crutch and butter fly handles , screwed with iron pipes or for union complete all as specified and directed by Engineer-in-charge.
S&F Stop valves 15 mm bore fancy type, CP with long shank & cup (conncelaed type), cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
S&F brass CP sewel type shower rose of size 100/125mm with arm including fixing to steel pipes complete all as specified and directed by Engineer-in-charge.
S&F 32/ 40 mm bore and 75 long PVC Waste pipe suitable for WHB /Sink complete all as specified and directed by Engineer-in-charge.
S&F PVC connection for 15 mm bore pipe,450mm long complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick PCC type B0 (1:2:4) (using 12.5 mm graded stone aggregate ) concrete as in roof pedding complete all as specified and directed by Engineer-in-charge.
M&L for 15 mm thick screed bed in cement mortar (1:3) over RCC roof slab mixed with water proofing compound including preparation of surfaces complete all as specified and directed by Engineer-in-charge.
S&F APP based polymeric water proofing membrane minimum weighing 3 Kg/sqm and 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm laid over and including applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm by torch application including cleaning of surface complete all as per approved manufacturer's instructions. complete all as specified and directed by Engineer-in-charge. Make: Bengal Bitumen/M/s STP Ltd./M/s IWL India Ltd./M/s M K Petro Product India Pvt Ltd. Note:-The water proofing treatment shall be carried out by manufacturer or their auth applicators as per manufactures instruction and as directed by Engr in Charge. .
M&L for anti-termite treatment by treating the back fill in contact with foundation at the rate of7.5 litres of emulsion per square metre of surface complete all as specified and directed by Engineer-in-charge.
M&L for anti-termite treatment by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface all as specified
M&L for anti-termite treatment by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engineer-in-charge.
M&L for anti-termite treatment treating the soil along perimeter of bldg at the rate of 2.5 litres of emulsion per running metre of perimeter wall complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of cement primer complete all as specified and directed by Engineer-in-charge.
Demolition of brick work built in cement mortar complete all as specified and directed by Engineer-in-charge.
M&L SGSW drain pipes 150mm dia laid in trenches and jointed in CM (1:3) complete all as specified and directed by Engineer-in-charge.
M&L cement concrete bed (1:3:6) type D-2 using 40mm graded stone aggregate as in bedding to pipes for 150mm dia including packing under and haunching against the side of the pipe after they are laid and tested complete all as specified and directed by Engineer-in-charge.
M&L for PCC(1:3:6) type C2 using 40 mm graded stone agg as in foundation and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L for brick work in CM (1:4) straight or curved on plan exc 6.0m mean radius and using old size sub class 'B' bricks complete all as specified and directed by Engineer-in-charge.
M&L for cement concrete type B2, 1:2:4,(20 mm graded stone aggregate)in surface channels and drains, complete all as specified and directed by Engineer-in-charge.
M&L for Rendering 15 mm thick in Cement Mortor 1:4 on fair faces of brick work or concrete Surfaces using Water Proofing Compound (WPC) as per manufacturer’s instruction, finishing the surfaces fair and even, complete all as specified and directed by Engineer-in-charge. (Supply of WPC shall be measured & paid separately)
Supply only integral water proofing compound complete all as specified and directed by Engineer-in-charge.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered /stopped ends etc complete all as specified and directed by Engineer-in-charge.
S&F steel fibre reinforced (SFRC) man hole covers with frame, 70mm thick in circular or rectangular in shape of area 0.246( + 0.05) Sqm set in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. Note:- Make of SFRC manhole / drain cover and frame shal be one of the following make as approved by GE (a) M/s P S Concrete (b) MS K K Manholes (c) Jain spun pipe or as approved by GE.
Construction of Septic tanks for 25 users complete all as specified and shown in Drawing (Drg No TD DZ-171).
Construction of Soakage wells for 25 users complete all as specified and shwon in drawing ( Drg No DZ-1124(R) ).
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregage) as in sub base of floor/ plinth protection finished fair & even and without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L factory made vibro compacted pre cast cement concrete 60mm thick inter locking rubber moulded coloured blocks / pavers in any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed by Engineer-in-charge.
Sand filling under floors or in foundation incl watering and consolidation complete all as specified and directed by Engineer-in-charge.
Dismantling of brick tiles (laid flat or on edge) on roof surface.laid bedded and pointed in any mortar complete all as specified and directed by Engineer-in-charge.
Demolition of mud in roof, any thickness, including plastering and leeping incl necessary scaffolding arrangement complete all as specified and directed(whether full thickness removed or only a part there of) and removing from cantonment area or as directed complete all as specified and directed by Engineer-in-charge.
M&L for brushing neat cement slurry with 3.00 Kg of cement per Sqm on existing surfaces complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new surface of APP membrane and applying two coats of aluminium paint at surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete (unreinforced) in any description and in any position not otherwise specially provided for complete all as specified and directed by Engineer-in-charge.
M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered and hold fast on edge including necessary form work complete all as specified and directed by Engineer-in-charge.
Demolition of stone slab and tiles of any description or thickness on cooking platform, floors, aprons etc laid bedded and pointed in any morter complete all as specified and directed by Engineer-in-charge.
M&L for machine cut kota stone slab flooring, and (one Pieces) as in steps (Treads), 20-25mm thick over cement screed bed 20mm thick with CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-charge.
All same as per Ser Item No. 96 above but of riser of step, dado skirting etc
M&L for Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble of any shade other than white and black complete all as specified and directed by Engineer-in-charge.
Rounding to edges of stone slabs one edge, such as in steps cooking platefom,and other similar situations complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
M&L for light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including screed bed or bedding layer of mortar 15mm thick in CM 1:6 complete all as specified and directed by Engineer-in-charge.
All same as per Ser Item No101 here in before but as in skirting laid over and including 10mm thick backing coat of cement mortar (1:4).
S&F in repair Vitreous China, pedestal pattern (EWC) wash down water closet pan, white including fixing bolts, connection to flushing cistern and flush pipe & drain pipe (or out going pipe) and to flushing pipe, anti-syphonage pipe, 'P' or 'S' trap etc complete all as specified and directed by Engineer-in-charge.
S&F in repair plastic water closet seat, white, closed pattern (seat & cover for Pedestal pattern) with flat bottom, and cover and mild steel chromium plated or aluminium hinging device, complete all as specified and directed by Engineer-in-charge..
S&F in repairs low level flushing cistern of 10 ltrs capacity PVC valveless, syphonic action type, white with inlet ball valve float and handle complete all as specified and directed by Engineer-in-charge.
S&F in repairs PVC connections 450mm long with brass unions at both ends suitable for 15mm bore pipe, complete all as specified and directed by Engineer-in-charge.
S&F in repair Vitreous china wash hand basin with pedestal white, flat back, size 550 x 400mm, including necessary waste pipe and coupling, brackets and cutting for and pinning in ends of brackets, complete all as specified and directed by Engineer-in-charge. (Note - WHB will be supported on angle iron of size 50x50x5mm duly painted with two coats of synthetic enamel paint for securing WHB).
S&F in repairs Chromium plated Pillar tap cast copper alloy with capstan heads screwed down high pressure screwed to 15 mm bore iron pipe complete all as specified and directed by Engineer-in-charge.
S&F in repairs elegent mirror PVC cabinet (PTMT alloy) complete all as specified and directed by Engineer-in-charge.
S&F in repairs 32mm bore of Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repairs brass chromium plated tubular towel rail, 20 mm dia D type , 60 cm long between flanges complete all as specified and directed by Engineer-in-charge.
S&F in repairs brass chromium plated shower rose of size 125 mm with arms including fixing to steel pipe complete all as specified and directed by Engineer-in-charge.
S&F CP jet spray with suitable PVC flexible pipe of 15 mm bore complete all as specified and directed by Engineer-in-charge.
S&F in repairs bib tap, brass chromium plated fancy type, long body screwed down, screwed for iron pipe 15 mm bore complete all as specified and directed by Engineer-in-charge.
S&F in repairs stop cock( consealed type),15 mm bore, chromium plated ,with long shank and cup, fancy type, complete all as specified and directed by Engineer-in-charge.
S&F in repairs 15 mm dia brass chromium plated angle valve screwed at ends including necessary extention piece and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repairs Cast iron floor trap with grating including jointing to waste pipe in run lead, dia of outlet 75 mm in cement concrete type B1 (1:2:4) complete all as specified and directed by Engineer-in-charge.
S&F for joist, channel, angle or tee sections, fixed independently using Fe 410-W (Gde-E-250) quality-A complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed by Engineer-in-charge.
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-charge.
S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed - Size of frame - 125 x 60mm complete all as specified and directed by Engineer-in-charge.
M&L for Cement concrete Type C-0, 1:3:6 using 12.50 mm graded agregatein walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed by Engineer-in-charge.
S&F fabricated aluminum window with powder coated anodized aluminum frame of section 63.5mm x 38.10mm x1.5mm thick, shutter with section 47.62mmx44.45mmx1.5mm thick including aluminum anodized “D “ handle, hinges, peg stays, tower bolts, etc including jointing cleats for fixing builder's hardware fittings & stainless steel wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples including necessary fittings/fixture /aluminum snap beads complete all as specified and directed by Engineer-in-charge. Note: Measurement shall be taken for clear opening i.e. out to out of window frame as a whole including all fittings and fixtures and no extra shall be paid separately.
S&F Aluminium powder coated Grill (DECO grill DG 103 of 7.5 mm thick of M/s ELESAR, M/S Royal Grill , M/S National Grill Associated profiles & Aluminium Ltd ) fixed with suitable 'F' Section (No 8584) 15.30 X23.40X 1.40 mm (minimum), fabricated adn riveted to aluminium window / ventilators complete all as specified and directed by Engineer-in-charge.
S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-charge.
S&F for 35mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed by Engineer-in-charge.
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples etc complete all as specified and directed by Engineer-in-charge.
S&F for mild steel, 300 mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-charge.
S&F 300 mm long, stainless steel of AISI 304 grade, sliding door bolt with hasp, staple (bolt type) and fixing clipss of sheet, cast or extruded sections and fixing bolts and fixed etc complete all as specified and directed by Engineer-in-charge.
S&F brass magic eye for panelled/flush shutter 35mm thick complete all as specified and directed by Engineer-in-charge.
M&L preparation of newly surfaces of steel of any description not otherwise described width or girth and applying two coats of synthetic enamel paint over & incl one coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L preparation of new or previously untreated surfaces of wood of any description not otherwise described width or girth and applying two coats of synthetic enamel paint over & incl one coat of pink primer complete all as specified and directed by Engineer-in-charge.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed by Engineer-in-charge.
S&F in repairs factory made PVC cupboard frame of size 75 mm x 40 mm with a wall thikness of 4mm , made out of extruded 4 mm thick prelam PVC sheet of density 600 / cbm manufactured by an ISO -9001-2015 certified company , reinforced with 15 mm x 15 mm MS square tubes of 19 gauge thickness throughout the frame and mitre cut at two corners and jointed with 2 nos of 150 mm long brackets of 10 mm x 10 mm MS Square tubes .The door frame shall be fixed to wall using 65 /100 long MS screws to be provided for each vertical member and minimum of 2 nos of screw to be provided horizontal member etc . complete all as specified and directed by Engineer-in-charge.
S&F factory made PVC flush type shutter and partition of 18 mm thickness with one side lamination & other side balancing lamination sheet consisting of Carcass 18mm thick PVC sheet of density 600 / cbm manufactured by an ISO -9001-2015 certified company ,and all required brackets 5.5 screw etc. The panell shall be fabricated using adhesive and screws where ever required. All the edges shall be covered with 2mm thick edge bonding tape or 90 degree edge bent finish as per make and specificationmentioned as per drawing including necessary fittings, locking and fixing arrangement ie piano hinges, handles, magnetic catches etc complete all as specified and directed by Engineer-in-charge.
S&F factory made solid FRP door frame of size 90mm x 45 mm made out of FRP sheet , suplying and fixing complete all as specified and directed by Engineer-in-charge.
S&F factory made solid panel FRP door shutter 30mm thick premoulded design made out of solid core, laminated 1.5 mm to 2mm thick GRP/FRP made of superior all seson, weather resistant polyyester get coat followed by laminating polyster resin of 450 gm glass mat termite all as per manufacturers specification complete all as specified and directed by Engineer-in-charge.
S&F in repair stainless steel of AISI 304 grade floor door stopper with hard drawn steel spring 140 mm long etc complete all as specified and directed by Engineer-in-charge.
S&F, 25mm dia MS drapery curtain rods, (Powder coated/rubber coated), including MS bracket powder coated and PVC powder coated side bulb complete all as specified and directed by Engineer-in-charge.
S&F Pre-painted galvantume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm th PCC 1:2:4 type B2 (40mm graded aggregates) as in finishing cement concrete surface even and smooth with out using extra cement complete all as specified and directed by Engineer-in-charge.
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade 'A' complete all as specified and directed by Engineer-in-charge.
Cutting chases or making holes, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer-in-charge.
Taking up or down steel tubing 15 mm bore and connection including cleaning for refixing. complete all as specified and directed by Engineer-in-charge.
Taking up or down steel tubing 20 mm bore and connection including cleaning for refixing. complete all as specified and directed by Engineer-in-charge.
Refixing of old steel tubing and connection in new or old position (Wall/Ceiling etc) incl cleaning for refixing, bore of pipe 15 mm dia complete all as specified and directed by Engineer-in-charge.
Refixing of old steel tubing and connection in new or old position (Wall/Ceiling etc) incl cleaning for refixing, bore of pipe 20 mm dia complete all as specified and directed by Engineer-in-charge.
Dismantling water tanks of capacity exceeding 250 litres but not exceeding 500 litres complete all as specified and directed by Engineer-in-charge.
S&F in repairs Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 15 mm bore complete all as specified and directed by Engineer-in-charge.
S&F in repairs Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI soil, waste and vent pipe in any length with or without ears, with cement joints, fixed to walls of 100 mm dia sand cast pipe complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI soil, waste and vent pipe in any length with or without ears, with cement joints, laid in trenches or floors of 100 mm dia sand cast pipe complete all as specified and directed by Engineer-in-charge.
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes of 100mm bore including packing under and haunching against sides of pipes after they are laid and tested. complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI soil, waste and vent pipe in any length with or without ears, with cement joints, fixed to walls of 75 mm dia sand cast pipe complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI Bends (any radius ), diminishing pieces or tapers of 100 mm dia fitted with oval access door complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI Bends with access door (any radius ), diminishing pieces or tapers of 100 mm dia without oval access door complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI Bends (any radius ), diminishing pieces or tapers of 75 mm dia fitted with oval access door complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI Bends (any radius ), diminishing pieces or tapers of 75 mm dia fitted without oval access door complete all as specified and directed by Engineer-in-charge.
S&F in repairs Cast iron branch pieces, Tee, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, 100 mm bore with cement joints, fitted with oval access doors complete all as specified and directed by Engineer-in-charge.
S&F in repairs Cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, 75 mm bore with cement joints, fitted with oval access doors complete all as specified and directed by Engineer-in-charge.
S&F 100 mm cast iron sanitary connections short connections pipe of length upto 300 mm complete all as specified and directed by Engineer-in-charge.
S&F Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for 100 mm bore pipes complete all as specified and directed by Engineer-in-charge.
S&F Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for75mm bore pipes complete all as specified and directed by Engineer-in-charge.
Taking down rain water pipe (any size) or pattern incl all fittings, head shoes, bends swan necks etc incl cleaning or re-fixing or removal to store(measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed by Engineer-in-charge.
S&F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, of 110 mm dia complete all as specified and directed by Engineer-in-charge.
S&F for PVC (SWR) bends any radius 110mm dia bore complete all as specified and directed by Engineer-in-charge.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated wall surfaces by complete removal of existing treatment and applying two coats of cement base paint, white or tinted (colour and shade as per new colour scheme approved by GE) over a coat of primer of same make including scaffolding for four storey building complete all as specified and directed by Engineer-in-charge.
M&L for Preparing new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care Putty complete all as specified and directed by Engineer-in-charge.
M&L for preparation by complete removal of existing treatment , wahsing down and stopping of distempered and painted surfaces and old plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care putty complete all as specified and directed by Engineer-in-charge.
M&L roughning surfaces of old concrete floor by packing, sweeping cleaning and washing down with water to remove dust etc brucing neat cement slurry @ 3Kg of cement per Sqm complete all as specified and directed by Engineer-in-Charge.
S&F 6 mm thick glass corner shelf (Single shelf) of best quility with CP steel railing of size (250mmx250mm) of best quality complete all as specified and directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge.
M&L for MS framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-charge.
S&F rolled mild steel work as in post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for escuring wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to GDE Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
S&F 5-10mm dia of shank mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n.exc 5cm long complete all as specified and directed by Engineer-in-Charge.
M&L for applying a coat of cement slurry @ 0.488 Kg/Sqm mixed with tapercreate @ 0.253 Kg/Sqm after cleaning and drying the old/new surfaces(Make of tapercreate M/S CICO Engg Services) then applying the layer of fibre glass cloth while the above coat is still green. The overlap of fibre glass cloth shall be not less than 100 mm.(Make of fibre glass cloth M/S The Structure Water Proofing Co Pvt Ltd) and then applying 1.5 mm thick layer @ 1.288 Kg/Sqm mixed with taper create @ 0.570 Kg/Sqm and coarse sand @ 1.289 Kg/Sqm. Allow the treatment to air curing for four hours followed by water curing for 48 hours complete all as specified and directed by Engineer-in-charge..
M&L for rendering with readymix plaster 10mm thick on fair faces of brick work or concrete surfaces finished even and smooth complete all as per manufacturer;s instructions and directed by Engineer-in-charge.( Make of ready mix plaste shall be Birla Aerocon/Ultratech readiplast/ACC Accoplast / Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE) Note:- Mixing of WPC in ready mix mortar is optional based on site requirement and as per manufacturers instruction and WPC shall be paid separately as supply only in respective item of this schedule.
Supply only liquid water proofing compound.(ISI Marked.Siko or equivalent/liquid type) complete all as specified and directed by Engineer-in-charge.
M&L for 25mm thick cement concrete type B-0 1:2:4 (12.5mm graded aggregate) as in sub floors finished rough complete all as specified and directed by Engineer-in-charge.
Cutting of trees including cutting of trunk n.exc 30cm girth and branches and digging out roots from floor or roofs and walls of up to four storied bldg and making good the dismantled portion in cement mortar 1:3 to match the existing surfaces complete all as specified and directed by Engineer-in-charge.
S&F mild steel galvanised chain link fencing including line wires, any mesh size and type of any type of standards rails straining bolts etc including provision of binding wire. Note:- Line wire & mesh shall be measured in Kg as per actual weight. However, provision of binding wire shall be included in the quoted rates.
Screed bed or bedding layer of cement mortar 20mm thick (1:6) for laying floor finishes complete all as specified and directed by Engineer-in-charge.
M&L for chequered cement concrete tiles 20 cm x 20cm x 25 mm thick in floors with grey cement and pigment, set and jointed and pointed in neat cement slurry in floors complete all as specified and directed by Engineer-in-charge.
E/M Portion Taking down carefully the old U/s aluminum point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete with single core multi strand copper conductor 1.5 Sqmm nominal area PVC insulated, sheathed, FRLS 1100 Volts grade electrical cable in and including concealed PVC conduit medium grade and sunk in new pressed steel terminal boxes of required size factory made and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet (ISI Marked) of required color with screwed and cup washer with all accessories including 1.5 Sqmm single core with multi strand copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified and directed by Engineer-in-charge for the following: Note:- The rate is inclusive cutting/chasing and making good the disturbed surface with cm 1:3 and same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash etc complete.
One light/fan point controlled by one way switch
One 3 pin socket outlet 5 amps independent board
One 3 pin socket outlet 5 amps point on same board
One 3 pin socket outlet, 15 amps on independent board with cable 2.5 Sqmm for main current and 2.5 Sqmm as earth wire as power point.
All as per item No 187 above but standard copper conductor 4 Sqmm for phase and neutral and 2.5 Sqmm standard copper conductor PVC unsheathed cable for earth.
S&F switch piano, flush type 5 Amps single pole one way, ISI marked complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 3 pin piano, flush type 5 Amps single pole one way, ISI marked complete all as specified and directed by Engineer-in-charge.
S&F switch piano, flush type 15 Amps single pole one way, ISI marked complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3/5 pin piano, flush type 15 Amps single pole one way,ISI marked complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface Bakelite 60x 25 mm two to three terminals, ISI marked complete all as specified and directed by Engineer-in-charge.
S&F LED Integrated Aluminium Batten T5 20 watt - 4 Ft White, indoor decorative PVC extruded T-5 LED battern - integrated type complete with all accessories including flexible copper wire complete all as specified and directed by Engineer-in-charge.
S&F LED 10 watt white Bulk head in engineering plastic housing with clear prismatic including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and directed by Engineer-in-charge. Cat Pt No : HLBH-02-10-CW of of Halonix or equivalent make of : Havells/Bajjaj/Phillips).
S&F LED Integrated Batten aesthetically designed linear mirror LED light fitting (LINNET) of 07 Watt 1' white, indoor decorative PVC extruded provided with a high output PMMA diffuser for glare free light LED battern integrated type complete with including flexible wire complete all as specified and directed by Engineer-in-charge. Cat Part No : LCL-07-CDL of Make : CG or equivalent Make in Havells/Bajaj/Philips.
S&F LED Building security light fitting 45W on existing bracket in replacement of old unsv existing security light fitting any type complete all as specified and directed by Engineer-in-charge. Cat Part No LTESS18x2.5HPLED/LS of C&S or equivalent Make of Havells/Bajaj/Phillips.
S&F MCB DB SPN 8 Way double door type, (IP 43 Protection) flush mounting for MCBs complete all as specified and directed by Engineer-in-charge.
S&F MCB SPN 40 AMPs 'C' curve complete all as specified and directed by Engineer-in-charge.
S&F MCB SP 10/16/20/30 or 40 Amps "C" curve complete all as specified and directed by Engineer-in-charge.
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 6 Sqmm, 1100 Volts grade on and including Concealed PVC conduit 25mm medium grade complete with conduit accessories and copper cable 6 Sqmm continuous earth wire (Two runs of cable with 01 earth wire shall be measured as one length) complete all as specified and directed by Engineer-in-charge.
Supply and fixing metal body exhaust fan 300 mm sweep, 230 Volts, single phase1400 RPM with copper wound and louvers including necessary electric connection with appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan complete all as per site requirement at site with complete all as specified and directed by Engineer-in-charge. Cat Pt No : Turbo Force SP of Havells or equivalent make of Bajaj/CG.
M&L light/fan/bell point controlled by one modular switch with PVC insulated, unsheathed, multi stranded, single core copper conductor cable 1.5 Sqmm suitable for fixing in existing concealed conduit with modular sunken pressed steel terminal boxes 2 mm thick of required size and modular white cover plate and frame in different module housing for fixing modular switches/modular socket and modular fan regulator etc. PVC insulated, unsheathed, multi stranded, single core copper conductor cable 1.5 Sqmm used as earth wire to commen earth and connected to common dolly drawn in same conduit complete all as specified and directed by Engineer-in-charge. Note : If blockage or damage of the existing conduit, new PVC conduit to be laid to passing the light/fan circuit and the rate of the same is inclusive in respected item)
One light / fan / bell point controlled by one No one way switch
One light point controlled by two 2-way switch
One 3 pin 5 Amps socket outlet point controlled by one number one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one number one way switch on same board.
All as per item No 203 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 socket outlet point on independent board.
S&F in replacement socket outlet 5 pin 5/6 Amp flush type complete two in one complete all as specified and directed by Engineer-in-charge.
S&F in replacement socket outlet 2 in 1, 5 pin 15/5 Amp flush type complete all as specified and directed by Engineer-in-charge.
S&F in replacement battan holder PVC insulated body complete all as specified and directed by Engineer-in-charge.
M&L in replacement for bell electric heavy duty Ding Dong type230 volts single pole complete all as specified and directed by Engineer-in-charge. Make Anchor cat part No 22535/ Cona cat part No : 2856.
S&F in replacement bell push AC 230 V, single pole, ISI marked complete all as specified and directed by Engineer-in-charge. Make : Cona/Kinjal/Havells
S&F in replacement of ceiling rose surfaces bakelite minimum size 65x50mm with two/ three terminals complete all as specified and directed by Engineer-in-charge.
S&F in replacement ceiling fan regulator electronic type complete all as specified and directed by Engineer-in-charge. Make : Cona/Kinjal/Havells
S&F Metal clad plug and socket 20 Amps with MCB SP and steel enclosure complete all as specified and directed by Engineer-in-charge. Make : ABB/Legrand.
S&F of LED of Integrated Aluminium Batten T5 20 watt - 4 Ft White, indoor decorative PVC extruded T5 LED battern-integrated type complete with including fliexble wire in replacement of old unsv existing 36 Watt tube light fitting with Cat Part No LTTB4F20LEDP/W of Make : C&S or equivlent Make in Havells/Bajaj/Philips/CG/C&S.
S&F LED Integrated with Aluminium Batten T5 10 watt - 2 Ft White, indoor decorative PVC extruded T5 LED battern -integrated type as fixing for mirror light complete with including flexible wire all as specified and directed in replacement of old unserviceable existing 15 Watt CFL light fitting Make : Benlo/Syska/Bajaj/CG
S&F in replacement LED 9 watt white Bulk head in engineering plastic housing with clear prismatic including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and directed by Engineer-in-charge. with Cat Pt No : CG80420 60/100W GLS/10-18W for retrofit lamp of C&S or CG/Bajaj/Phillips
S&F in replacement of LED Building security light fitting 45 Watt including necessary electrical connection from bottom/middle of the wall to security light fitting in conclealed with PVC conduit complete all as specified and directed by Engineer-in-charge. Cat Part No LTESSE45WLED of C&S (Make :- Bajaj/Halonix/Philips/CG).
S&F LED RETROFIT LAMP of 12 Watt LED lamp for batten holder and bulk head fitting complete all as specified and directed by Engineer-in-charge. Make C&S\Havells\Philips
Supply and fix in replacement of BLDC (Bruishless Direct Current) ceiling fan of 1200mm sweep, not less than 350 RPM, not less than Air Delivery 215 cfm, Voltage 220V, high air follow with with silence operation, having full copper motor & ribbed 3 Nos A/M blades. The BLDC motor fan shall have 100% rust-free blade. the fan shall have BEE 5 star rating and compliant with IS-374 and making ncessary electric connection of suitable PVC copper wire from ceiling rose to ceiling fan complete all as specified and directed by Engineer-in-charge. Make : Havells / Bajaj / Orient. (Note : Existing fan to be deposited in MES yard)
M&L for opening of hole through out the wall as suitable for exhaust fan of size 300mm sweep and fixing of nut-bolts with 4" anchor fastner of suitable size and making food the disturbed surface and all as per site requirement complete all as specified and directed by Engineer-in-charge. Note : The rates are inclusive in respect of under this item as above hole opening civil work with MS faster bolt of 8mm dia and 100mm (minimum) long for fixing of exhaust fan and MS fastner clamps strip 38 mm wide and 5mm thick (min) to hold exhaust fan
Supply and fix in replacement MCB DB SPN 8 Way with metal double door, (IP43 Protection) flush mounting epoxy powder control having 200 Anos rated bus bar complete all as specified and directed by Engineer-in-charge.
M&L in replacement MCB SPN 'C' curve 63 Amps 240 Volts , 10 KA complete all as specified and directed by Engineer-in-charge.
M&L in replacement MCB SP 'C' curve 06 to 40 Amps 240 Volts complete all as specified and directed by Engineer-in-charge.
M&L in replacement for submain wiring of two runs of 6 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through existing steel/PVC conceiled conduit of size 25mm dia with all fittings accessories complete all as specified and directed by Engineer-in-charge. Note:- New conduit of suitable size with connected fittings shall be laid, if there is damage/ blockage in existing conduit and the rates are inclusive of quoted rates and same surface finishes with the adjoining surface of disturbed area with OBD/Colour wash/ White wash.
M&L in replacement for submain wiring of two runs of 10 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through existing steel/PVC conceiled conduit of size 25mm dia with all fittings accessories complete all as specified and directed by Engineer-in-charge. Note:- New conduit of suitable size with connected fittings will be laid, if there is damage/ blockage in existing conduit and the rates are inclusive of quoted rates and same surface finishes with the adjoining surface of disturbed area with OBD/Colour wash/ White wash.
Supply & Fixing in replacement of sheet metal enclouser MCCB DB IP 20 double door bus bar neutral link earth bar and din rail VTPN 4 way make MDS Legrand Cat No : 507755 (DPX³ 250+12) or equivalent in C&S/Siemens/ABB complete all as specified and directed by Engineer-in-charge.
Supply & Fixing in replacement of board MCCB 125 Amps 4 pole 415 Volts 16 KA on distribution board including electrical connection with bus bar or incomer with appropriate size of aluminium lugs and insulation packing complete all as specified and directed by Engr-in-Charge..
M&L in replacement for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing complete all as specified and directed by Engineer-in-charge.
M&L in replacement for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicate dsituation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed by Engineer-in-charge.
Taking down of exsting unserviceable MCCB/MCB DBs with MCCBs &MCBs complete all as specified and directed by Engineer-in-charge.
Supply & fixing of water storage heater 5 star in white colour (Geyser) of capacity 25 ltr, vertical type, AC, electric, 230 Volt complete with heating element, thermostat, 3 core power lead, Plug top, safety valve, inluding electric and water connection and making good to disturbed surface complete all as specified and directed by Engineer-in-charge. Model : Senzo with Cat Pt No : GHWASESWH025 of Havells or equivalent make of Bajaj/CG
S&F in replacement switch piano flush type 6 Amp two way ISI marked complete all as specified and directed by Engineer-in-charge.
S&F in replacement switch piano flush type 15 Amp single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F in replacement switch piano flush type 5 Amp single pole one way complete all as specified and directed by Engineer-in-Charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
P R Constructions
M/S.M.S.Devi.Const.Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .