Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500 015 | SECUNDERABAD | HYDERABAD | TELANGANA | 500015 | L1 | Accepted-AOC OK | |
| 2 | L2₹27.9 L+₹1.2 L (4.51%)Rejected-AOC H NO 1 7 1 79 1 ROAD NO 7 REDDY ENCLAVE TEMPLE ALWAL SECUNDERABAD 500 010 | HYDERABAD | TELANGANA | 500010 | L2 | Rejected-AOC OK | |
| 3 | L3₹27.9 L+₹1.2 L (4.52%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹29.1 L+₹2.3 L (8.67%)Rejected-AOC | L4 | Rejected-AOC OK | |
| 5 | L5₹29.1 L+₹2.3 L (8.77%)Rejected-AOC | L5 | Rejected-AOC OK |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
11 Mar 2021, 6:00 pmClosed
SHRI MAHAVIR SINGH, IDSE
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD
REPAIRS TO TEMP ROOF, FALSE CEILING AND ROOF TREATMENT TO POL AREA, NEW SAFILGUDA JCOs/ORs AND NEW ASSEY LINE OF AGE B/R (SOUTH) NO. I UNDER GE (SOUTH) SECUNDERABAD
2021_MES_422803_1
GE (S)/SEC/TOKEN - 69 OF 2020 - 21
Open Tender
Civil Works
Item Rate
240 days
Secunderabad
For Enlisted contractors class D and above category a (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
5 documents required · 5 mandatory
₹500
GE SOUTH, MUDFORT, SECUNDERABAD
₹70,000
Yes
28 Apr 2021
16 Feb 2021
13 Mar 2021
16 Feb 2021
11 Mar 2021
27 Feb 2021
17 Feb 2021 - 26 Feb 2021
Amount
Dismantling of single layer mangalore pattern or similar tiles roofing inclduing ridges complete all as specified and as directed.
Dismantling the battens for tiles of any size including tiling fillets spaced exc 15cm complete all as specified and as directed.
S&F rolled Mild steel sections as in main and cross beams hip and jack rafters, purlines fixed independentlyof Fe-410W (Gde-250) quality A complete all as specified and as directed.
M&L Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strengh of 550 mpa as on roof covering/ridges fixed with self tapping screws complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated, semi corrugated, etc) sheets in roof covering incl ridges complete all as specified and as directed.
M&L for 6mm thick AC corrugated sheets in roofs fixed with 'L' or 'J' type in cranked hooks bolts complete all as specified and as directed.
M&L for 6 mm thick asbestos cement two piece separated ridge for corrugated or semi corrugated sheets complete all as specified and as directed.
Dismantling timber scantling 40 sq cm and over in any position complete all as specified and as directed.
S&F 2nd class hard wood as in scantling clean sawn timber fixed complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F Hand rails, half round or other steel section nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes notching of wire, etc and similar work conforming to Fe-290 Gde E-165
Demolition of brick work or stone masonry built in cement mortar, or cement line mortar including all quoins, arches pillars etc.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6. complete all as specified and as directed.
M&L brick work with sub class B bricks straight or curved on plan to any radious in half brick thick walls built in CM 1:4. complete all as specified and as directed.
Taking down cement plaster from brick or stone walls, ceiling etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick works in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15 mm thick rendering on fair faces of brick work or cement concrete surfaces in cement mortar 1:4, finished fair and even without using extra cement incl mixing of water proofing compound complete all as specified and as directed. (Note: Water Proofing compound shall be measured and paid for separately)
M&L for making good of the fallen/broken portion of the RCC Roof/Ceiling with proper reinforcement binding & application of antifungal paint for avoiding rusting of old steel reinforcement complete all as specified and as directed.
M&L prepartion of new surfaces on walls and applying two coats of oil bound distemper over a coat of primer with wall care putty in two coats complete all as specified and as directed.
M&L prepartion of new surfaces on walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
M&L preparation of newly plastered surfaces of walls and applying three coats of white washing complete all as specified and as directed.
M&L perpartion of new plaster surfaces and applying three coats of white wash on ceiling complete all as specified and as directed.
M&L preparation of surfaces over a coat of priming paint and applying two coats of cement base paint on new plastered surfaces of wall complete all as specified and as directed.
M&L prepartion of new surfaces and applying two coats colour washing on wall surfaces complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets.
M&L for providing false ceiling with anodised aluminium snap grid frame work with size of grid 605 x 605 mm with aluminium main tee size 25 x25 x1.60mm thick and, cross T section of size 25 x 25 x 1.60mm thick and wall angle of size 25x25x2mm thick fixed to roof with rawl plugs/GI wire suspenders complete all as specified and as directed.
Providing and fixing Gypsum board 12mm thick in ceiling fixed with screw as per manfacturers instructions and as per specified and as directed by Engineer-in-chage.
M & L 4 mm thick Non-Asbestos Cement Plain ceiling boards, fixed to timber/ Aluminium frame work with screws in ceilings and preparing surface, applying two coats of OBD over a coat of primer complete all as sepcified and as directed by Engr-in-Charge.
Demolition of cement concrete of any description and in any position not otherewise specifically provided for as in roof incl tarfelt etc complete all as specified and as directed.
M&L for 40mm thick plain cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in padding (level course) on roof finishing cement concrete surfaces even & smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
M&L for rendering 10 mm thick in CM (1:3) using water proofing compound as per manufacturer instruction as in roof and chajjas finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge. Note : Water proofing compound will be measured and paid separately.
M &L for priming plastered roof surfaces with bituminous primer @ 0.3 Kg/Sqm as per IS 3384 and providing water proofing treatment by applying 3.5 Kg/Sqm Actatic polypropylene (Advanced APP torch on membrane mineral finish) having polyester film reinforcement stabilized with fibre glass and finished on top with grey mineral slabs torch on system of thickness 3 mm by torch bonding complete all as specified and as directed by Engr-in-Charge.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
Supply only water proofing compound complete all as specified and as directed.
S & F 15 mm dia steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls,(concealed) including taking down old pipe complete all as specified and as directed.
S & F 20 mm dia steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls, including taking down old pipe complete all as specified and as directed.
Demolition and breaking up drain AC pipes/PVC pipe set in cement mortar of any size complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed to walls bore of the pipe 110mm complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed to walls bore of the pipe 75mm complete all as specified and as directed.
S&F in repair PVC (SWR) bends 110mm complete all as specified and as directed.
S&F in repair PVC (SWR) bends 75mm complete all as specified and as directed.
Cleaning of RCC/PVC water tanks with bleaching powder disconnecting the connection & removing all scales and dirt etc from tanks & from mouth of circulating pipes etc including writing with paint out side tanks " tank cleaned on with month and year " capicity of tanks exc 250 & n exc 500 ltrs and recconneting, air lock complete all as specified and as directed.
Cleaning of RCC/PVC water tanks with bleaching powder disconnecting the connection & removing all scales and dirt etc fromtanks & from mouth of circulating pipes etc including writing with paint out side tanks " tank cleaned on with month and year " capicity of tanks exc 750 & n exc 1000 ltrs and recconneting ,air lock complete all as specified and as directed.
S&F in repair rotational moulded polyethylene water storage tanks 500 ltrs(cylindlerical verrtical with closed top) hoisted and fixed in position all as specified in SSR part I including dismantaling of existing damaged water tanks.
S&F in repair rotational moulded polyethylene water storage tanks 1000 ltrs(cylindlerical verrtical with closed top) hoisted and fixed in position all as specified in SSR part I including dismantaling of existing damaged water tanks.
S&F in repair PTMT ball valves 20 mm dia high pressure with epoxy coated aluminium rod and high denscity plastic ball screwed for iron pipes and fixed to iron pipes.
S&F in repairs Gun metal globe or gate valves 20 mm dia high pressure with polythene float and fly nut complete screwed for iron pipe or for unions complete all as specified and as directed.
M&L for uprooting of wild trees such as grass/ bushes etc., from the roof / wall surfaces /AC sheets/ Soil pipes surroundings including its penetrated roots with suitable cleaning chemical and making good to the damaged plaster by providing CM 1:3 and finish the surfaces to match with the existing surfaces complete all as specified and as directed.
G SATISH REDDY AND CO
3I CONSTRUCTIONS
MVS ENTERPRISES
NARAYANA CONSTRUCTIONS
M/S V PRATAP REDDY
harshraj and co
M/S DIVIJA BUILDERS
S.R.M.K Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .