Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹30.0 L+₹1.9 L (6.89%)Rejected-Finance | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹32.9 L+₹4.9 L (17.5%)Rejected-Finance | L3 | Rejected-Finance Other Than Lowest Bidder | |
| 4 | L4₹33.9 L+₹5.9 L (20.9%)Rejected-Finance 3082 SECTOR 20D CHANDIGARH 160 020 | CHANDIGARH | CHANDIGARH | 160020 | L4 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
17 Dec 2022, 6:00 pmClosed
GE Chandigarh
GE Chandigarh N Area Pin-160003
COMPREHENSIVE MAINT OF E/M ASSESTS ON DAY TO DAY BASIS AND REPAIR/REPLACEMENT OF OLD PERISHED INTERNAL WIRING AND REPLACEMENT OF FLORESCENT TUBE LIGHT WITH LED FITTINGS AND FIXTURES WITH SUB MAIN AND DBS OF MD ACCN AT K AREA GE CHANDIGARH
2022_MES_564281_1
GE/CHD-66/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Chandigarh
Class D category b(i) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹80,000
Yes
19 Jan 2023
21 Nov 2022
19 Dec 2022
21 Nov 2022
17 Dec 2022
5 Dec 2022
21 Nov 2022 - 28 Nov 2022
Amount
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for laying of cable,poles stay, eathing etc. and getting out complete all as specified.
Excavation in trenchs .exc. 1.5 mtr in depth but not exceeding 3 mtr in depth for,pole base, eathing and getting out in any type of soil complete all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I
Supply and laying of class B bricks for under ground cable protection as directed by Engineer- in - charge
Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 complete all as specified.
Cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate in coping padestal to poles, earth chamber pit and repair to road cutting including necessary finishing the exposed surface even and smooth in cement mortar 1:3 complete all as specified.
Supply and fix MCCB 4 Pole, 415 V, adjustable thermal type (40% to 100%) and adjustale magenetic release TPN 415 volt, bracking capacity 35 KA, ICS =100 ICU, Adjustable type, 630 Amps complete in repair all as specified and as directed.
All as per item ser No 09 above but MCCB of cap 400 Amps 25 KA.
All as per item ser No 09 above but MCCB of cap 250 Amps 25 KA.
All as per item ser No 09 above but MCCB of cap 200 Amps 25 KA.
All as per item ser No 09 above but MCCB of cap 160 Amps 25 KA.
All as per item ser No 09 above but MCCB of cap 100 Amps 25 KA.
All as per item ser No 09 above but MCCB of cap 63 Amps 25 KA.
All as per item ser No 09 above but MCCB of cap 3 pole, 125 Amp, 36KA.
All as per item ser No 09 above but MCCB of cap 3 pole 100 Amp, 25KA.
All as per item ser No 09 above but MCCB of cap 3 pole 63 Amp, 25KA.
Supply , and laying in repair GI earth plate of size 60cmx60cmx6 mm thick (having drilled two nos holes of dia 10 mm one at centre and other in between top and centre for fixing of GI strip/ GI wire any size ) laid vertically in centre of a earth pit of depth 4.5 Mtrs complete all as specified and as directed.
Supply and fixing in repair GI Strip of size 32x6 mm with GI earth plate under item ser no 19 above complete al as specified and as directed
Supply and fixing in repair GI Strip of size 25x4 mm with GI earth plate under item ser no 19 above complete al as specified and as directed
Supply and fixing in repair GI wire of size 4 mm with GI earth plate under item ser no 19 above complete al as specified and as directed
Supply and fixing GI bolt( full thread) ,Nut and wahsers of size 10 mm thick 25 mm long Note :( One GI bolt,one nut and two nos washers shall be considered as one set)
Supply and fixing in repair GI pipe medium grade of size 15 mm complete all as specified and as directed.
Supply and fixing in repair GI watering funnel with wire mesh complete all as specified and as directed.
Supply and filling sea salt in earth pit complete all as specified in SSR part -I and as directed by Engr-in-Charge
Supply and filling charcoal dust in earth pit complete all as specified in SSR part -I and as directed by Engr-in-Charge
Supply and filling bentonite powder in earth pit complete all as specified in SSR part -I and as directed by Engr-in-Charge
Supply and fixing GI protection pipe light grade of size 40 mm complete all as specified and as directed.
Supply and fixing GI protection pipe light grade of size 15 mm complete all as specified and as directed.
S&F in repair 100 mm bore Tubes ‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified .
All as item No 31 above but of size 80 mm
All as item No 31 above but of size 50 mm
Taking out existing damage/unservisable PVC insulated, armoured, aluminium conductor 1100V grade cable of any size and core from trenches, pipes, walls and/or poles, stagging properly testing for serviceability of cable, cutting and segregating serviceable portion for relaying & depositing unservisable cable in MES store yard complete all as specified . NOTE: Excavation and earthwork shall be measured and paid for separately
Laying only of PVC insulated,armoured heavy duty, electric cable with stranded aluminum conductor of size 3.5 core 240 sqmm 1100 volts grade, laying in trenches, passing through pipes, fixed along walls and/or poles complete all as specified of size.
All as per item No 35 above but cable of size 185 Sq.mm, 3.5 core
All as per item No 35 above but cable of size 150 Sq.mm, 3.5 core
All as per item No 35 above but cable of size 120 Sq.mm, 3.5 core
All as per item No 35 above but cable size 3.5 core70 sqmm
All as per item No 35 above but cable of size 50 Sq.mm, 3.5 core
All as per item No 35 above but cable of size 35 Sq.mm, 3.5 core
All as per item No 35 above but cable of size 25 Sq.mm,3.5 core
All as per item No 35 above but cable of size 10 Sq.mm, 2 core
All as per item No 35 above but cable of size16 Sq.mm, 4 core
S & F in repair heat shrinkable straight through joint for 1100 volt grade XLPE cable of size 70 Sqmm to 150 Sqmm, 3.5 core complete all as specified.MAKE : DENSON, M-SEAL, BIRLA-3M.
S & F in repair heat shrinkable straight through joint for 1100 volt grade XLPE cable of size185 Sqmm to 300 Sqmm, 3.5 core complete all as specified.MAKE : DENSON, M-SEAL, BIRLA-3M.
S & F in repair heat shrinkable straight through joint for 1100 volt grade XLPE cable of size 25 Sqmm to 50 Sqmm, 3.5 core complete all as specified.MAKE : DENSON, M-SEAL, BIRLA-3M.
Cutting road for passing the cable/pipe and making good with plain cement concrete 1:3:6, type C-1 using 20 mm graded crushed stone aggregates complete all as specified. Note :- 1.Average width of excavation 300mm,average depth 600mm and average thickness of PCC 250mmm, 2.Cost of PCC 1:3:6 Type C-1 for repair of road cutting is deemed to be included in the quated rate.
Supply & install steel tubular pole swaged welded with MS base plate size 30cm x 30cm x 6mm thick final taper plug bolts nuts & washers as per IS: 2713 (part-I) 1980 made out of MS tubing including painting of two coats of aluminium paint of approved quality over one coat of red oxide primer length 9.00 mtr long 410 SP -31 using for any description of external electric work all as specified and directed by Engr-in-chargeincl dismantling of old unsv PCC pole and demolition of PCC foundation.
Supply and fixing poly propylene composite LT phase separator, bolted type for ACSR conductor of any size, suitable for 05 wires, complete all as specified.
Supply and fixing poly propylene composite LT phase separator, bolted type for ACSR conductor of any size, suitable for 02 wires, complete all as specified.
Dismantling of old unserviceable ACSR conductor and Supply and Fixing New ACSR by stratching required tension on existing LT pole conductor complete.
Material and Labour for fabrication of Cross Arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat and two under coat of synthetic enamel paint and incl removing rusted cross arm complete.
M&L galvanised steel wire 4 mm dia for making craddle, hexagonal / rectangular, across span complete and including dismantling of old unserviceable GI wire.
Supply and Fixing Shackle type porcelain, vitreous white, brown insulator incl galvanised mild steel straps, washers, insulator bolts, washers and nuts working pressure 1100 Volts. 75 mm in heiqht and 90 mm dia and incl galvanise steel fittings like straps and bolts complete.
M & L stay assembly with stay rod of 20 mm diameter complete with accessories as shown in electrical plate No. 1 complete with loop type insuator, stay clamp and stay wire of size 7/2.5 mm etc . (Eart work and PCC shall be measured and paid separately)
S&F in repair cylendrical less fire suppression system consisting of pneumatic heat detecting and fire suppression Tube 18mm x 15mm x 2 mtr long filled with clean agent gas, in white colour with SS fitting & FT Pressure Gauge at one end filled with Gas for protection of Electric panel.
Preparation of surfaces of LT Steel poles by and painting applying one coats of aluminium paint and writing pole No in black and yellow. Strip upto 1.5 mtr height at an intervals of 30cm each from the ground level and above coping for 09.00 mtr pole all as directed at site.
Supply and fixing of Change over switch 100 Amps, TPN, 420 volts rewirable fuze type complete all as specified and as directed.
Supply and fixing of Change over switch 63 Amps, TPN, 420 volts rewirable fuse type complete all as specified and as directed.
Repair to LT panel Inddor/outdoor installed at various location of K area by replacing of unsv door hinges, door locks to door hinges with new door locks and hinges , replacement of worn out bottom, /top sheet of LT panel by providing with new CRCA sheet of same thickness . Scrubing and removing of rusted paint from panel board completely by burning through blow lamp . Cleaning of panel sheet all around by empry paper and applying metal filling to prepare the ssurface for primer and painting. Spray Painting of the panel board inside and out side with one coat of red oxide primer and two of superior quality synthetic enamel paint of original colour of panel or colour as aproved by Engineer-in-Charge using compressor and spray gun. Note :- 1. Contractor will arrange single phase generator set for suply to the compressor and electric supply of the panel will be shut down during painting. Running/hiring cost of gen set and compressor is deemed to be included in the quoted rates of job
M& L for Informatory sign board of size 1000mm x600mm made out of 2mm thick aluminium sheet fixed on Chromium plated Stainless steel Pipe frame of 50mm Dia, 2.25mtr long vertical member and 40mm Dia 1.30mtr horizontal member ,including letter writing (100 to 150 words) , logo/drawing made with computerized printing of fully retro reflective with high intensity prismatic tape pasted on sheet with single side writing including frame emmebedded in 0.30x0.45mtr in PCC (1:3:6 ) type C-1 complete all as specified and directed by the Engineer-in-charge Note : (i)The cost of Excavation post hole, earth work , PCC for foundation etc shall be deemed to be included in the unit rate of this item. Nothing extra shall be admissible on this account.(ii) The letter size of Main heading shall be minimum100mmx10mm and sub heading letter size shall be minimum 50mmx5mm.(iii) The drawing and colour of writing work shall be got approoved by Engineer in charge.
S&F and connecting in repirs Metallized polypropylene film heavy duty box type MPP-H capacitor fixed type of 5 KVAr complete with suitable amps rating capacitor duty power contactor 1 NO/1 NC ,440 volts 3 phase 5-Hz.
All as per item No 63 here in beore but of cap 7.5 KVAr
All as per item No 63 here in beore but of cap 12.5 KVAr
All as per item No 63 here in beore but of cap 15 KVAr
All as per item No 63 here in beore but of cap 20 KVAr
All as per item No 63 here in beore but of cap 25 KVAr
S&F Power Contactor 32 Amp 3 Pole AC 3 Capacitor Duty complete all as specified and as directed.
S&F Power Contactor 50 Amp 3 Pole AC 3 Capacitor Duty complete all as specified and as directed.
S&F Power Contactor 65 Amp 3 Pole AC 3 Capacitor Duty complete all as specified and as directed.
S&F MCB 25 Amp TP C Curve 415 Volts 50 HZ complete all as specified and as directed.
S&F MCB 50 Amp TP C Curve 415 Volts 50 HZ complete all as specified and as directed.
S&F MCB 63 Amp TP C Curve 415 Volts 50 HZ complete all as specified and as directed.
S&F ON,OFF Indicating Lamp complete all as specified and as directed.
S&F Start,Stop Push Button for APFC Panel complete all as specified and as directed.
Surface dressing in hard/dense soil n exc 15 cm deep , levelling and site clearence for electric instalations area and water supply installation .
Supply, fixing connecting and testing Motor protection unit(MPU) three phae 415 volt , 50 HZ ,automatic phase sequence corrector automatically correct inut reverse phase, single phase protection, LV, HV, LIV, Auto of loft, timer, Dry running under & over current, unbalancing ,float switch with built in CTs (Automatic-RTM ) complete all as specified. & directed
Taking down existinng U/S worn out Busbar chamber from the position after carefully disconnecting the cable terminals &supply fixing and connecting up complete bus bar chamber 100Amps capacity with copper bus bar 4way out going all as per cat no IHBB010004 make-Havells or equivalent in L&T/legrand to be fixed/ partly flushed in wall complete all as directed by Engg- in-Charge
M&L Point wiring with 1.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable in and including concealed , non metalic rigid pvc medium grade ISI marked conduit not less than 19 mm with all fittings & other accessories and also including PVC insulated ISI marked unseathed FRLS cable of size 1.5 sq mm copper conductor as earth wire to common earth dolly including concealed in wall/ceiling, modular MS Box, 1.6mm thick with modular cover plate with frame as required at site suitable for modular switches, sockets, fan regulator etc for One light/fan point controlled by one way switch 6 amps 240 volts : Note:-1. Colour code of wiring should be (for phase -Red, Neutral-black & earth wire green) 2. Modular switch sockets fan regulators shall be meaured and paid separately udner respective items. 3. Cost of mudular MS box , modular cover plate an frame of any modules as required at site and as directed by Engineer-in-charge is deemed to be included in th quoted rates.
All as per item No 81 above but one fan point controlled by one switch and one regulator.
All as per item No 81 above but one 3 pin 6 Amps switch socket out let point on independent board
All as per item No 81 above but one 3 pin 6 Amps switch socket out let point on same board
All as per item No 81 above but one call bell point controlled by one way bell push switch
All as per item No 81 above but one light point controlled by two way switch
All as per item ser No 81 here in before but wiring with 2.5 sqmm copper conductor for power point
Point wiring for one light point/fan point controlled by one switch with 1.5 Sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.50 Sqmm PVC insulated unsheathed copper conductor single core multi strand flexible and 1.50 sqmm PVC insulated unsheathed copper conductor single core cable (green colour as earth lead in and including concealed non metallic rigid PVC conduit medium grade with all fittings (ISI marked) controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge & 3mm thick plastic laminated sheet, iuncluding cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per item ser No 88 above but point wiring for one fan point
All as per item No 88 above but one 3 pin 6 Amps switch socket out let point on independent board
All as per item No 88 above but one 3 pin 6 Amps switch socket out let point on same board
All as per item No 88 above but one call bell point controlled by one way bell push switch
All as per item No 88 above but one light point controlled by two way switch
All as per item ser No 88 here in before but wiring with 2.5 sqmm copper conductor for power point
M&L for sub main wiring with two single core, PVC insulated,ISI marked, unsheathed, 1100 volts grade multistranded copper conductor cable drawn into and including suitable size non metalic rigid pvc concealed conduit (ISI marked) concealed/surface with all accessories and including one single core pvc insulated multistranded unsheathed 1100 volts grade copper conductor cable as earth wire of 2x4.0 sqmm + 1x4 sqmm earth wire size as in repair incl cutting and chasing and making good thw disturbed surface to match the existing complete all as directed & specified.
All as per item No 95 above but 2x6.0 sqmm + 1x6.0 sqmm earth wire
All as per Item No 95 here in above but of 3X2.5 Sqmm.
S&F in repair switch modular 6 Amps 230 volts one module complete all as specified and as directed.
S&F in repair modular socket shutter suitable for 6 Amp 2/3 pin combined 250 volts complete as per specified and directed
S&F in repair modular switches suitable for 16 Amp 240 volts complete as specified and directed
S&F in repair modular socket shutter suitable for 16 Amp 2/3 pin combined 250 volts complete as specified and directed.
S&F in repair modular step type fan regulator suitable for 120 watt 250 volts complete all as specifed and directed
S&F in repair modular bell push switch 6 Amp 240 volte suitable for one model etc complete as specified and directed.
S&F in repair switch piano flush type single pole one way 6 Amp 240 volte complete as specified and directed
S&F in repair socket shutter 5 pin 6 amps flush type 250 volts complete all as specified and as directed
S&F in repair switches piano flush type 16 Amp 240 volts complete as specified and as directed .
S&F in repair socket shutter suitable for 16 Amp 2/3 pin combined 250 volts complete as specified and directed.
S&F in repair step type fan regulator suitable for 120 watt 250 volts complete all as specifed and directed
S&F in repair switch two way 6 Amp 240 volte suitable for one model etc complete as specified and directed.
S&F in repair bell push switch 6 Amp 240 volt piano type complete all as specified and as directed.
M&L for call bell ding dong AC 230 Volts single pole etc complete as specified and directed
M&L for ceiling rose with three terminal as per relevant IS complete as specified and directed
S&F in repair lamp holder pvc/polycarbonate type with back plate suitable for batten fitting complete as specified and directed
Supply and fix in repair LED retrofit INVERTER lamp 9W with 04 hrs back up time, Cool white, (lumen output not less than 900 lumens) at main supply and 450 lumns at backup , CRI more than 80,operating voltage 230 V AC 50 HZ , opeating temperature (-10⁰ C to +50⁰C), glarefree, 0 UV radiation all as specefied and directed.
Supply and fix in repair LED lamp screw type (Thread type) 8 watts (cool white)
S&F LED retrofit inveter type T-Beamer 10 watts with 4 hrs back up LED bulb (Cool day light)lumens out put not less than 1000 lumes at main and 500 lumens at backup, CRI more than 80, operating voltage 220-240 volts,glarefreee,0 UV radiation, retrofit Home base B-22 with polycarbonate body.
S&F in repairs energy saving new generation 10 W LED IP 65 bulkhead luminaire with opal diffuser incl 3 core flexible cord from ceiling rose to connector of fitting etc complete as specified and directed
S&F in repair surface mounted round type energy saving ceiling mounted decorative LED 8 watt luminair luminair with opal diffuser for soft light with suitable size driver incl 3 core cable from ceiling rose to connector of fitting etc complete as specified and directed
S&F in repair mirror light sleek LED mirror light provided with high output diffuser with suitable capacity driver with all comptonants as per manufacturer with 3 core flexible cord from ceiling rose to connector of fitting etc complete as specified and directed
S&F in repair surface mounted round type energy saving ceiling mounted decorative LED 8 watt luminair luminair with opal diffuser for soft light with suitable size driver incl 3 core cable from ceiling rose to connector of fitting etc complete as specified and directed
S&F as in repair batten LED 22 w inveter LED tube light complete fitting 230 volt energy saving, 04 hrs battery backup, CRI ≥80 more than, driver efficiency ≥ 85%, operating voltage 230 volt, 50hz operating temp (-10°C to 50°C) complete accessories internally pre wired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed by engineer-in-charge.
S&F in repair epoxy powder coated or polystrene insulated material sheet metal enclosure factory made 2 way SPN suitable for MCB DB's 240 Volts with neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed.
S&F in repair epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 4 way SPN suitable for MCB DB's 240 Volts with 100 Amps rated busbar, neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed
S&F in repair epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 6 way SPN suitable for MCB DB's 240 Volts with 100 Amps rated busbar, neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed
S&F in repair epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 8 way SPN suitable for MCB DB's 240 Volts with 100 Amps rated busbar, neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed.
S&F in repair epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 12 way SPN suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed.
S&F in repair epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 4 way TPN suitable for MCB DB's 415 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete as in repair all as specified and directed.
S&F in repair epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 4 way VTPN (IP43) suitable for and incl MCCB TPN 100 mps 16 KA, DB's 415 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed.
S&F in repair MCB single pole ISI marked ISI Marked `B' series working on 240 Volts 50 HZ AC supply for incomming and out going controlling cercuit of capacity 6-32 Amp breaking capacity 10 KA as in repair etc all as specified and directed.
S&F in repair MCB single pole ISI marked ISI Marked `B' series working on 240 Volts 50 HZ AC supply for incomming and out going controlling cercuit of capacity 40-63 Amp breaking capacity 10 KA as in repair etc all as specified and directed.
S&F in repair MCB triple pole and neutral ISI marked `B' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 40-63 Amps 10 KA breaking capacity as in repair etc all as specified and directed.
S&F in repair MCCB 4 pole 63 Amp fixed type 16 KA fixed thermal & fixed magnatic setting suitable for 415 volts as in repair.
S&F in repair 16 Amps power outlet board consisting of 01 No 5 pin 5/15 Amps socket with one sigle pole MCB `B' series 20 Amps 240 volts etc complete as specified and directed .
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed standard aluminiu conductor 2 core 10 sqmm in service connections suspen- ded by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed.
All as per item ser No 134 above but 2 core 6 sqmm.
All as per item ser No 134 above but 2 core 4 sqmm.
S&F in repair bracket made out of 32 mm dia, 1.50 mtr long GI tubing, "medium grade" ISI marked, bent to required shape and angle as per site requirement with and including MS clamps size 30 x 5mm, with nuts, bolts, washers etc for fixing street light fittings and bracket, duly painted with two coats of aluminium paint over a coat of red oxide primer including taking out existing unserviceable rusted GI bracket complete all as specified and as directed.
Cutting & trimming of tree trunks / branches of grith not more than 80 mm falling on or likely to fall on LT over head electrical lines for a clearence of 6 meter on ground from the nearest counductor / pole /earth etc. & desposal of unservicable materials to distance not exc.50 mtrs. & clearing of site all as directed by Engg. -In - Charge
Supply and install digital timer switch in sheet metal encloser havig the contact rating : 16A AC1 usb key version : EG103E. 1 channel weekly cycle 56 adjustment pre recording programme two moudules with impulse and holiday function having the contactors rating all for AC 7A lead only (Coil voltage 230V 50Hz). for remote switch control a power circuit 3 No, 63 A 3 modules complete all as per manufacturer's specificationsincluding taking down old unserviceable fittings of any size/ wattage complete all as directed by Engr-in-Charge. Make for timer switch : Hager Cat part No EG103E or equivalent in L&T, ABB, HAVELLS. MAke for contactors : Hager Cat part no ESC363 or equivaelnt in L&T ABB, HAVELLS .
S&F in repair LED Driver suitable for up to 60 watt security light fitting complete all as specified and as directed.
S&F in repair LED Driver suitable for up to 72/90 watt security light fitting complete all as specified and as directed.
S&F in repair LED Driver suitable for up to 100 /200 watt security light /flood light fitting complete all as specified and as directed.
S&F in repair LED surge protection device having maximum discharge surge current (Imax) -10kA (8/20 µs), Nominal discharge surge current ( In)-5kA (8/20 µs) and protection level (Up) upto 5 kv up to 200 watt security light /flood light fitting complete all as specified and as directed.
PVC insulated multi-stranded copper conductor 16 Sq mm (nominal area) 3 core submersible cable and connected to submersible pump set including submersible cable joints & LT panel board complete all as specified and directed.
PVC insulated multi-stranded copper conductor 10 Sq mm (nominal area) 3 core submersible cable and connected to submersible pump set including submersible cable joints & LT panel board complete all as specified and directed.
S&F FASDS suitable for 35 HP Submersible electric driven pump set ,3 Phase , AC 415 volt ,50 HZ with IP 66 MS enclouser with Std proction ie single phase, over volt /under volt etc complete Make : BCH/Seimens/scheneider/havells
S&F power contractor 3 phase 415 volts 50 HZ 100 amps with auxilary contacts 02 NO and 02 NC , AC coil complete all as specified and as directed.
Supply and fix in repair thermal overload relay of current range 45 - 65 amps AC 415 volts nominal current 54 amps with aauxilary contacts 1 NO and 1 NC complete all as specified and as directed.
Supply and fix in repair single phase preventer for three phase starter suiable for submersible motor of capacity up to 50 HP complete all as specified and as directed.
S & F in repair Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Taking out old unsv eathing material such as earth plate, earth main lead , protection pipe and watering pipe etc from the eath pit as directed.
Supply and fix in repair modular cover plate with frame 2 module complete all as specified and as directed.
Supply and fix in repair modular cover plate with frame 3 module complete all as specified and as directed.
Supply and fix in repair modular cover plate with frame 4 module complete all as specified and as directed.
Supply and fix in repair modular cover plate with frame 6 module complete all as specified and as directed.
Supply and fix in repair modular cover plate with frame 8 module complete all as specified and as directed.
Supply and fix in repair modular cover plate with frame 10 module
Supply and fix in repair modular cover plate with frame 12 module
Supply and fix in repair Metal flush box 3 module complete all as specified and as directed.
Supply and fix in repair Metal flush box 4 module complete all as specified and as directed.
Supply and fix in repair Metal flush box 6 module complete all as specified and as directed.
Supply and fix in repair Metal flush box 8 module complete all as specified and as directed.
Supply and fix in repair Metal flush box 10 module complete all as specified and as directed.
Supply and fix in repair Metal flush box 12 module complete all as specified and as directed.
Supply and fix in repair PVC gang Box 2 way 05 amp complete all as specified and as directed.
Supply and fix in repair PVC gang Box 4 way 05 amp complete all as specified and as directed.
Supply and fix in repair PVC gang Box 2 way 15 amp complete all as specified and as directed.
Supply and fix in repair cable flexible, PVC insulated, twin core with copper conductor of size 24/0.20mm, complete all as specified and as directed.
Supply and fix in repair cable flexible, PVC insulated, three core with copper conductor of size 32/0.20mm, complete all as specified and as directed.
Supply and fix in repair cable flexible, PVC insulated, three core with copper conductor of size 30/0.25mm, complete all as specified and as directed.
Supply and fix in repair PVC insulated and unsheathed FRLS single core multistranded copper conductor of size 1.5 sqmm complete all as specified and as directed.
All as per item no 171 above but of size 2.5 sqmm.
All as per item no 171 above but of size 4 sqmm
All as per item no 171 above but of size 6 sqmm
All as per item no 171 above but of size 10 sqmm
Supply and fix in repair plug top 3 pin 5 amps AC 230 volts complete all as specified and directed.
Supply and fix in repair plug top 3 pin 15 amps AC 230 volts complete all as specified and directed.
Supply and fix in repair bakelite sheet not less than 2 mm thick of size 100x100 mm complete all as specified and as directed. Make : Hylum/ Formica/ Grean laminated boards
All as per item No 178 but of size 175 x 100mm
All as per item No 178 but of size 200 x 200 mm
All as per item No 178 but of size 200 x 250 mm
All as per item No 178 but of size 250 x 300 mm
Supply and fix in repair 23 to 30 cm long ,10 mm bore C.P Connection with brass union complete all as specified and as directed
Supply and fix in repair Gun metal non return valve ,15 mm bore complete all as specified and as directed
Supply and fix in repair 45 cm long , 15mm bore PVC connection pipe with brass union both ends fixed to GI Pipe complete all as specified and as directed
Supply and fix in repair Apparatus plate for 25 litre / Syphon Assy complete all as specified and as directed
Supply and fix in repair Rubber O ring /gaskit for 25 ltrs complete all as specified and as directed
Supply and fix in repair PVC batten of 20 mm (width) complete all as specified and directed .
Supply and fix in repair PVC conduit pipe, ISI marked, 19/20 mm bore, complete all as specified and as directed.
Supply and fix in repair PVC bend heavy duty suitable for 20 mm dia PVC conduit complete all as specified and as directed.
Supply and fix in repair PVC junction box 2 way/3 way suitble for 20 mm PVC conduit complete all as specified and as directed.
Supply and fix in repair round PVC cover for junction box complete all as specified and directed.
Supply and fix in repair MS machine screw 25mm long of dia not less than 5 mm complete all as specified and directed
Supply and fix in repair MS machine screw 50mm long of dia not less than 5 mm complete all as specified and directed
Supply and fix in repair bulb (Green/Red colour) 15Watt B22 holder based complete all as specified and as directed.
Supply and fixing PVC rawl plug marshal grip of size 25 x8 mm complete all as specified and as directed.
Supply and fixing MS Anchor bolt(Fastener) of size 100 mm length and 10 mm dia complete all as specified and as directed.
Supply and fix PVC clamps suitable for PVC conduit of size 19/20 mm dia complete all as specified and as directed.
Supply and fixing and testing split type air condition 3 Star rating unit with indoor having hot and cold provn perated unit single phase 220 Volt complete of capacity 1.5 Ton installation including copper tubing as required upto 10 mtr and providing seasoning tape etc and makinhg good disturbed surface complete as directed by engineer -in- charge.(Old UNSV Item hand over to MES Store Yard)
Supply and fixing and testing split type air condition 3 Star rating unit with outdoor having hot and cold provn perated unit single phase 220 Volt complete of capacity 1.5 Ton installation including copper tubing as required upto 10 mtr and providing se(Old UNSV Item hand over to MES Store Yard)
M&L for Point wiring complete with 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc., all as specified and as directed for one switch socket outlet 16 Amps on independent board.
Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete along with fittings such as switches, ceiling roses, bell, regulators sockets etc, and removing from site and making good distribut surfaces of walls, floors etc all as directed.
Disconnection and removing the u/s 3X1.5 Sqmm PVC insulated unsheathed cable from the existing conduit and M&L for 3x1.5 Sqmm PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistandard with copper conductor drawn in the existing metal/PVC conduit & Casing capping including connecting of the ends into the switch / socket/ DB complete.
Taking down existing unserviceable sub main wiring 2.5/4/6 Sqmm aluminium cable all as directed.
Disconnection and removing the u/s LED lamp and S&F LED lamp 9 watts complete all as spfd and directed.
Disconnection and removing the u/s casing caping conduit and S&F PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements complete.
S&F MCB DB, TPN, 6 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
S&F MCB DB, TPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
S&F MCB DB, TPN, 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed.
Taking down existing unserviceable MCB DB/TPN along with MCBs complete by disconnecting all as directed.
S&F MCB SP 6-30 Amps 230 volts 10 KA ISI marked complete all as specified and as directed.
All as per Item No 211 here in above but of capacity MCB DP 40 Amps
All as per Item No 211 here in above but of capacity MCB DP 63 Amps
All as per Item No 211 here in above but of capacity MCB SPN 63 Amps
All as per Item No 211 here in above but of capacity MCB TPN 32 Amps
All as per Item No 211 here in above but of capacity MCB TPN 40 Amps
All as per Item No 211 here in above but of capacity MCB TPN 63 Amps
Disconnection and removing the u/s MCB plug and socket unit and S&F Single pole and neutral Enclosure with a two pin earth plug and socket complete controlled by one single pole MCB 20 Amps 240 Volts, complete all as specified and as directed.
Disconnection and removing the u/s light fitting and S&F as in repair batten for LED tube light 1X18/20 watts LED, 230Volt energy saving recess, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer in Charge.
Supply and fixing in repair LED tube rod 1X18/20 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x18W to 20W, complete all as specified and directed by Engineer in Charge.
Supply and fixing in repair LED tube rod 1X10 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x10W, complete all as specified and directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F surface mounting mirror light luminaire 10 watts LED, 230Volt energy saving accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting from the fall ceiling carefully and S&F LED (2X2) indirect light fitting circular shape 36 Watts 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
S&F decorative Post top LED 40 Watt for 360* indirect light with IP 65 protection 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
Disconnection and removing the u/s light fitting from the Surface mountend carefully and S&F Surface mounted LED (1X4) Panel indirect light fitting 40Watts, 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
Disconnection and removing the u/s round down light and S&F Ceiling mounted Slim design LED recessed round Downlight with Superior light output and internal driver 22 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
Disconnection and removing the u/s square downlight and S&F Ceiling mounted Slim design LED recessed Square Downlight with Superior light output and internal driver 18 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
S&F as in repair batten LED 22 w inveter LED tube light complete fitting 230 volt energy saving, 04 hrs battery backup, CRI ≥80 more than, driver efficiency ≥ 85%, operating voltage 230 volt, 50hz operating temp (-10°C to 50°C) complete accessories internally pre wired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed by engineer-in-charge.
M&L bus bar chamber size 40 cmx25cmx20cm with tin plated copper plated bus strip 4 nos and iron lead and suitable to accommodate 4 pole 63-100 Amps MCCB and provision of MS gland for cable entry with locking arrangement of cap 200 amps 415 volts 50 hz partly flushed to wall and including making good to disurbed potion and colour wash to match the existing surface .Note : MCCB shall be measured and paid separately
Disconnection & taking down the unserviceable building light high wattage (30/25 Watts) street light fittings and Supply & fixing energy efficient Intergral type LED 25W Street light luminaire comprising of epoxy powder coated hsg, enclosed with glass cover in frame mounted testing compelte all as specified and directed.
Dismantling the earth chamber, Excavation and removing the u/s earthing materials along with u/s and M&L for earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 2.25 mtr below normal ground level, connected to GI wire 4cmm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20mm dia GI watering pipe ‘medium grade’, GI protection pipe of size 20 mm dia upto 7.5 mtr length , funnel with wire mesh, earthing chamber with cement concrete (1:2:4) type B-1, RCC chamber cover 80mm thick (1: 1 ½ : 3) type B1, excavation & earth work all as shown in electrical plate No 5 of SSR (Part-I) and testing on completion, complete all as specified and directed.
Taking down existing control board (Meter Box) and supply and fixing sheet metal board made of 1.6mm thick metal sheet and painting 2 coats with synthic enamel paint over a coat of primer including copper bus bar and fixed with wall for fixing meter complete with wiring, fitting and accessories, locking arrangements with handle (minimum size of box 65cmx75cm and adequate depth for the following equipments, internal wiring and termination of external cable, lugs and glands and conduits as required) comprising of following. (a) Incoming 100Amp 4 pole MCCB 25 KA-01 Nos. (b) Bus bar 100 Amp Aluminium (d) 10Amp DP MCB-01 No (Outgoing for stair case and garage) (c ) 40Amp DP MCB-04 Nos (for Qtr meters) (e) Fixing only arrangement for electronic type energy meters single phase 240Volt 40Amps 50HZ -04Nos. MAKE: Indo asian/ M/S Power System and controls Note : Elect meter will be issued under Sch 'B' free for fixing only.
Material and labour of LT Panel making electric connections incl wiring by Conductor multistranded PVC insulated welding of doors , fixing hinges, Thimble Refixing of MCCBs and brazing etc incl complet all as spd and diercted by Engineer-in-Charge
Supply and fix Modular blank plate one module complete all as specified and as directed.
Sabhyata Electrical and Mechanicals
Arun enterprises
LONGIA ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .