Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC | ₹1.4 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.5 LRejected-Finance | ₹1.5 L | L2 | Rejected-Finance Quoted higher than L1. |
| 3 | L3₹1.6 LRejected-Finance VILL BARAKURA P O SATBANKURA DIST PASCHIM MEDINIPUR PIN 721253 | SATBANKURA | PASCHIM MEDINIPUR | WEST BENGAL | 721253 | ₹1.6 L | L3 | Rejected-Finance Quoted higher than L1. |
| 4 | L4₹1.6 LRejected-Finance | ₹1.6 L | L4 | Rejected-Finance Quoted higher than L1. |
| Sl No | Description | Qty | Unit | M R ENGINEERING CORPORATION L1 | Binayak Enterprise L2 | R.P.ENTERPRISE L4 | SUSANTA GHOSH L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | SITC of 3 star rating 2.0TR split air cinditioner machine with R32 gas including remote controller of following capacity suitable for operation on 230V +/- 10% volt,50Hz single phase AC supply with air cooled evaporator with copper coil,fan and fan motor.air cooled copper condenser, hermetically sealed copper compressor,propeller fan control panels incl wirings,necy power cable connections from unit to power socket,refrigerant pipe of appropriate size between indoor and outdoor unit upto 3 mtr length. both suction & delivery incl. gas charging,complete as required make ; Necy Ply wood board of 19 mm to be fixed for installation of the machine,duly painting as per wall colour.,Daikin,blue star,voltas or equivalentProviding and fixing copper pipe with nitrile rubber insulation not less than 0.6mm thickness suitable size required for suction and return refrigerant with suitable insulation for above AC s complete in all aspects as required in excess of 3mtrs / machine inclSupply and laying 20mm dia ISI marked flexiblepvc pipe along with accessories on surface of the wall to drain out condensate water from indoor unit 5 to10mm thickness 3'' Dia. upto G/F drain. Machine to be installed by S and F factory fabricated MS structure for placing the 2.0 TR capacity split outdoor unit on existing building. By MS fastner &S andF 4C flexib;e copper cable of 4sq.mm from indoor to outdoor unit incl.connection,commissioing testing etc as reqd | 3 | Each | 37,109.38 ₹1.4 L | 38,281.25 ₹1.5 L | 42,800 ₹1.6 L | 41,500 ₹1.6 L |
Tender Value
Refer Docs
EMD Value
₹3,400
Closing Date
14 Dec 2024, 1:00 pmClosed
University Engineer, C.U.
Office of the University Engineer Darbhanga Building, 87/1 College Street Kolkata- 700073, University of Calcutta.
SITC OF AC MACHINES TO BE INSTALLED AT THE ROOM NS6347 ALLOTED FOR RUSA2.0 AT 5TH FLOOR Of BALLYGUNGE SC COLLEGE, C.U.
2024_CU_779994_1
E-tender/Eng/EQ-346/24-25
Open Tender
SUPPLY OF ELECTRICAL GOODS/EQUIPMENTS
15 days
BALLYGUNGE SCIENCE COLLEGE CAMPUS, C.U.
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹3,400
6 Jan 2026
6 Dec 2024
16 Dec 2024
6 Dec 2024
14 Dec 2024
6 Dec 2024
Amount
SITC of 3 star rating 2.0TR split air cinditioner machine with R32 gas including remote controller of following capacity suitable for operation on 230V +/- 10% volt,50Hz single phase AC supply with air cooled evaporator with copper coil,fan and fan motor.air cooled copper condenser, hermetically sealed copper compressor,propeller fan control panels incl wirings,necy power cable connections from unit to power socket,refrigerant pipe of appropriate size between indoor and outdoor unit upto 3 mtr length. both suction & delivery incl. gas charging,complete as required make ; Necy Ply wood board of 19 mm to be fixed for installation of the machine,duly painting as per wall colour.,Daikin,blue star,voltas or equivalentProviding and fixing copper pipe with nitrile rubber insulation not less than 0.6mm thickness suitable size required for suction and return refrigerant with suitable insulation for above AC s complete in all aspects as required in excess of 3mtrs / machine inclSupply and laying 20mm dia ISI marked flexiblepvc pipe along with accessories on surface of the wall to drain out condensate water from indoor unit 5 to10mm thickness 3'' Dia. upto G/F drain. Machine to be installed by S and F factory fabricated MS structure for placing the 2.0 TR capacity split outdoor unit on existing building. By MS fastner &S andF 4C flexib;e copper cable of 4sq.mm from indoor to outdoor unit incl.connection,commissioing testing etc as reqd
Binayak Enterprise (BID ID -5857019)
SUSANTA GHOSH (BID ID -5825891)
R.P.ENTERPRISE (BID ID -5837386)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid