| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L1 | Accepted-AOC DUE L1 RATE | |
| 2 | L2₹14.4 L+₹1.3 L (10.4%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 RATE | |
| 3 | L3₹15.7 L+₹2.7 L (21.0%)Rejected-Finance PO LEKHAPANI DIST TINSUKIA PIN 786 180 ASSAM | 786180 | L3 | Rejected-Finance OTHER THAN L1 RATE |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
14 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE LEKHAPANI
TINSUKIA, ASSAM
PERIODICAL SERVICES AND MISC REPAIR IN ZONE-1, ZONE-III, ZONE-IVA AND ZONE-IVB OF VARIOUS UNIT AT LEKHAPANI
2023_MES_612143_2
8752/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class E and category a (i)
9 documents required · 9 mandatory
₹500
GE LEKHAPANI
₹30,000
Yes
24 Nov 2023
23 Sept 2023
17 Oct 2023
23 Sept 2023
14 Oct 2023
30 Sept 2023
Amount
M&L for preparation of old plastered surfaces of walls,by washing,rubbing down and stopping of distempered and painted surfaces etc.and applying one coat of acrylic distemper complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls and applying one coat of white wash complete all as specified and directed.
All as per item No 2 above but in ceilings complete all as specified and directed..
M&L for preparation of old painted or plastered surfaces of walls etc by washing, rubbing down and applying one coat of cement base paint complete all as specified and directed.
M&L for preparation of old painted or plastered surfaces of walls etc by washing, rubbing down and applying two coats of cement base paint complete all as specified and directed.
M&L for complete removal of existing treatment on old plastered surfaces of walls and preparing surfaces as directed by applying thin layer of wall care putty of 1 to 2 mm thick and finally applying two coats of acrylic distemper over a coat of primer complete all as specified and directed.
M&L preparing old wood & wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water & removal of debris off the premises etc. complete all as specified and directed.
M&L for rendering 15.mm thick CM (1:4) on fair faces of brick work or concrete surfaces including finishing top even and fair mixed with WPC complete all as specified and directed.. (Note : WPC shall be measured seperately)
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description), from wooden frames, glazed with putty or fixed with beads complete all as specified and as directed.
S&F 2.5 mm to 3 mm thick PVC transparent window panes ordinary quality and glazing with oil putty / wooden beads as required in squares n exc 0.5sq. m in each pane complete all as specified and as directed
S&F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) Exc 250 Ltr an Nexc 500 Ltr complete all as specified and directed.
M & L Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed.
S&F in repair 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball, screwed for iron pipe & fixed (Minimum weight 210 gms) complete all as specified and directed.
Taking down existing treatment of any description and any layer from roof including scraping and roughening old by picking, sweeping clan and washing down complete all as specified and as directed
M & L screed bed 15mm thick CM (1:4) over Roof mixed with water proofing compound @ 3% weight of cement or manufacturer instruction finished even and smooth complete all as specified and as directed
Supply only integral water proofing Liquid, complete all as specified.
M & L for applying APP modified bituminous water proofing membrane with polyester reinforcement and plain finish of 3 mm thick (not less than 3.8 kg/ sqm ± 5 % per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25° C, 0.87-0.89 kg/ litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc. and including applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed.
M&L PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and as directed.
Dismantling water tanks exc 500 Ltr but not exceeding 1000 Ltr capacity complete all as specified and as directed by Eng-in-charge.
S&F Rotational moulded polyethylene water storage tanks of 500 ltr capacity,(cylindrical vertical with closed top) double layered, hoisted and fixed in position all as specified in SSR part-I & and directed by Eng-in-charge.
Taking up or down steel water tubing and connections, including cleaning for re-fixing or removal from site, for bore of pipes 20mm dia complete all as specified and directed.
S&F GI pipe 20 mm dia (medium grade), galvanised iron, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, fixed to walls as in repair complete all as specified and as directed.
S&F PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, fixed to walls as in repair complete all as specified and as directed.
S&F PVC (SWR) bends 110mm dia any radius as in repair all as specified and directed.
RC CONSTRUCTION
RIA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .