Tender Value
₹5.3 Cr
EMD Value
₹5.9 L
Closing Date
4 Jul 2022, 6:00 pmClosed
CE AF Allahabad
HQ CE AF Allahabad Bamrauli Allahabad
PROVISION OF ADDITIONAL BUILDING FOR STORAGE AND SERVICING OF PODS AT D-LEVEL POD COMPLEX AT 4 WG AT AF STATION AGRA
2022_MES_508272_3
958432/E8
Open Tender
Civil Works
Lump-sum
365 days
Agra
As per tender
9 documents required · 9 mandatory
₹3,000
Yes
GE AF TA Agra
₹5.9 L
Yes
15 Nov 2022
3 Jun 2022
11 Jul 2022
3 Jun 2022
4 Jul 2022
20 Jun 2022
Amount
SCHEDULE A PART I (BUILDING WORKS)
Lump sum amount worked out by the contractor for BUILDING WORK as SHOWN IN listed in Sch ‘A’ Part I.
SCHEDULE A PART II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch ‘A’ Part II.
SCHEDULE A PART III (Path)
Lump sum price worked out by the contractor for Path as listed in Sch ‘A’ Part III.
SCHEDULE A PART IV (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Sch ‘A’ Part IV.
SCHEDULE A PART V (AREA DRAINAGE)
Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Sch ‘A’ Part V.
SCHEDULE A PART VI (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Sch ‘A’ Part VI.
SCHEDULE A PART VII (EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION as listed in Sch ‘A’ Part VII.
SCHEDULE A PART VIII (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch ‘A’ Part VIII.
SCHEDULE A PART IX (AIR CONDITIONING)
Lump sum price worked out by the contractor for AIR CONDITIONING as listed in Sch ‘A’ Part IX.
SCHEDULE A PART X (SITE CLEARANCE, EARTHWORK & EXCAVATION )
Lump sum price worked out by the contractor for SITE CLEARANCE, EARTHWORK & EXCAVATION as listed in Sch ‘A’ Part X.
Schedule A Part -XI (Miscellaneous Items of B&R and E&M (to be quoted by bidder in BOQ)
Supply & Fixing Thermo Plastic Interlocked Switched Wall Socket box with DIN Rail comprising of a 32 Amps (2 P + E) sockets with safety cover with ingress protection level IP-44 and a rotary type ON / OFF switch with a 32 Amps SPN MCB (C Series) including a 32 Amps Plug Top (2P + E) duly grouted flush on brick wall complete with internal connections all as specified and as directed. Make : Hensel (Socket Cat part No .AT 130 306 : Plug Cat No.230306) Legrand (Socket Cat No .056669 : Plug Cat No.052742)
Supply & Fixing Thermo Plastic Interlocked Switched Wall Socket box with DIN Rail comprising of a 63 Amps (3 P + N + E) sockets with safety cover with ingress protection level minimum IP-66 and a rotary type ON/OFF switch with a 63 Amps TPN MCB (C Series) including a 63 Amps Plug Top (3P + N + E) duly grouted flush on brick wall complete with internal connections all as specified and as directed. Make : Hensel (Socket Cat No .AL 169 TS : Plug Cat No.262) Legrand (Socket Cat No .057299 : Plug Cat No.053844)
Suuply & fixing LED High Bay Light Fitting 80 Watt (Lumen Efficacy 150 Lm / Watt) with Ingress Protection level not less than IP-65, suitable to operate with 230 Volts 50 Hz single phase AC supply complete with all prewired internal components like electronic driver, surge protectors etc and all fixing hardwares and necessary electrical connection from nearby ceiling rose / connectors all as specified and directed Make : Havells (Cat Part No SAUCER GENXPROHBP80WLED757P90DBOLTG) / Crompton (Cat Part No :CIP-320-80-57-60D-HL5-NSR) / Bajaj (Cat Part No. BGHB 80W LED GIV)
Supply & Fixing LED Street Light Fittings having Ingress Protection class minimum IP-65 , suitable for road lighting luminaire with high power LED and maintenance free system for capacity 20 Watt complete with 32 mm bore light grade GI pipe bracket (1.5m long) duly bent to shape including 2 Nos MS Flat ieon (25mmx5mm) clamps, nuts, bolts, washers complete all as specified and as directed. Make : Philips (Cat Part No : BRP022 LED 20 CW MR S1 PSU GR) Havells (Cat No. : ENDURAPEARLSL20WLED757SASYTOPCMP ) Bajaj Cat Part No. BCLST 20 W LED I V2 Note : The MS Clamps are to be painted with 2 coats of Aluminium Paint over a coat of Red Oxide Metal Primar before fixing at different positions.
Supply & fixing air ventilating fan copper wound 230 mm sweep Metallic body, AC, single phase, 230 volts, complete with louvers shutters and including PVC insulated 3 core 1.5 Sqmm copper cable from ceiling rose to exhaust fan complete all as specified and directed.
Supply & fixing flame proof wall mounting fan 415 mm sweep copper wound Suitable for single phase 230 volt AC, 1440 RPM, including mounting nut, bolts, washer, fastners and connecting fan to ceiling rose including provision of three core flexible copper cable of size 1.5 Sqmm of ength / not less than 0.5 RM long for connection complete with fixing arrangement complete all as specified an directed. Make :- Sudhir (Cat. No:-WMF/140) Prateek Explosionproof Pvt Ltd (MIDC Badlapur Maharashtra) JD Electricals (Harmi, Vadodara Gujarat) / Trimiti Electricals (Thane, Maharashtra)
Supply & fixing flame proof exhaust fan 457mm (18") mm sweep (heavy duty) (coper wound motor) single phase 230 volt AC 1440 RPM, with louvered shutters including mounting frame, nut, bolts, washer, fastners and connecting exhaust fan to ceiling rose including provision of three core flexible copper cable of size 1.5 Sqmm not less than 0.5 RM long for connection complete with fixing arrangement complete all as specified an directed . Make :- Sudhir (Cat. No:-EF/140) / Smart Tech, Vapi Gujarat (Model No: FF1001) / Spot Trading Co.New Delhi
Supply, Installation, testing & Commissioning of commercial Air Curtain unit of size 2.4 RM x 2.4 RM for prevention of dust and conditioned air loses, suitable to operate in 230 Volt, single phase, 50 Hz AC Supply. The item shall be made out of CRCA Steel Sheet of minimum thickness 18 guage with MS / CRCA square perforated suction grills and finished with powder coated paint (oven baked) with aluminium alloy fans and single phase electric motor , nozzles etccomplete with all fixing accessories so as to produce 1.0 - 1.50 M per Second air velocity at floor level for door opening all as specified and directed. Make : ALMONARD / EURONIX / AKASH
Supply & Fixing Flame proof weather proof LED fixture 2 x 20 Watt x 4 feet long complete all as specified and directed. Make :- Crompton ( Cat part No: EXTN2LT8-16/20) / Sudhir (Cat. No:-FF/1272) or Equivallent Model in Baliga
Supply & Fixing Load Break Switch (LBS), HT 11 KV with integral earth switch & fuse trip confirming to IEC: 60265 /IS: 9220, Indoor type 2mm thick CRCA / MS sheet enclosure with following specification :- a) Panel type designation- CSH 12 rated system voltage 12 KV b) Rated current rating 400 amps c) Nominal system voltage - 11 KV, 50 Hz d) One minute power frequency voltage withstand level -28 KV RMS. e) 1.2/50 micro second impulse voltage withstand level - 75 KV peak f) Type of Insulation - Air insulation, 3 poles g) Rated short time withstand current 25 KA per 3 Sec h) Rated short circuit breaking capacity - Not assigned. HT HRC Fuses of 25 KA used to break SC current and trigger the tripping mechanism of load break switch. i) Rated Short Circuit making capacity - 62.5 KA. j) Cable termination - Incoming / Outgoing cables entry/exit from bottom. k) Type of operating mechanism - Quick make, Quick break, manual spring assisted toggle. l) Type of Installation - Indoor Type, Floor Mounted m) Degree of protection - IP 54 n) Paint type and shade - Epoxy based powder painting to shade RAL 7032 Make : ABB / SCHNEIDER / SIEMENS Note : (i) Any item missed out above but is technically required for safe and proper operation of equipment, shall deemed to be included in the quoted rate. (ii) The contractor shall have to arrange for factory visit to witness the Routine and Type Test (Non Destructive) as per relevant IS / IEC codes, in the presence of representative of Accepting Officer.
Supply & laying burnt bricks sub class 'B' locally available old size laid flat acros the length of trench for protection of cable complete all as specified.
Shifting of distribution transformer (11 KV/0.433KV of capacity 315 - 500 KVA) from its existing location to its proposed location (within 5.0 -8.0 KM) after taking necessary shut down, disconnection of HT / LT cables, earthing connections and including necessary loading / unloading charges and hire charges of hydraulic lifting machines / cranes and necessary connection to HT / LT cables, earthing connections etc.in new location complete all as specified and as directed at site.
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 2200 mm (W) x 1500mm (H) (Without Canopy & Base Channel) x 750mm Depth, MS Channel Base Frame mounted (to be mounted on the 3 side (front & two sides) covered brick pedestal of height 450 mm above ground level), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 600 Amps, including provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables the Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar. The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA steel sheet and 3.15mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the 3 side covered (front & two sides) brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings:- (A) BUSBARS 4 Nos bus bar of of rating 600 Amps made out of equal size Aluminium strip of suitable size with heat shrinkabal type coloured PVC sleeves, mounted on FRP / DMC insulators - 01 Job (B) INCOMING (i) S&F Air Circuit Breaker (ACB) 4 pole, suitable for 3 phase 4 wire system having double break main contacts and of rating 630 Amps with breaking capacity 50 KA, Electrical Draw Out Type,Breaking time not more than 30 mili seconds complete with all standard accessories and as described in PS -01 No
(C) OUTGOING (i) MCCB, 4Pole, 125 Amps, breaking capacity 16 KA, suitable for 415 volts, 50Hz AC Supply with adjustable type thermal and fixed magnetic release - 03 Nos (1 for AC plant + 1 for VTPN 12 way DB + 1 Spare) (ii) MCCB, 4Pole, 100Amps, breaking capacity 16KA, suitable for 415 volts, 50Hz AC Supply with adjustable type thermal and fixed magnetic release - 02 Nos (for 2 Nos VTPN 8 way DBs) (d) MCCB, 4Pole, 63Amps, breaking capacity 16 KA, suitable for 415 volts, 50Hz AC Supply with adjustable type thermal and fixed magnetic release - 3 Nos (for VTPN 6 Way DBs) (e) MCB TPN 32 Amps 10KA 'B'Series - 2 Nos. ( 1 No For Capacitor Bank + 1 No for Security Light) (f) MCB SPN 16 Amps 10 KA 'B'Series - 1 No. (Car Parking) (g) DIN rail mounted, Astronomical Time Switch, 1 Channel, 16 Amps, suitable for operate in 230 volts AC 50 Hz - 01 No.(LEGRAND /L&T / SCHNEIDER) (h) Power Capacitor ,5 KVAr , MDXL type suitable for operate in 415 Volts AC 50 Hz supply - .3 Nos (j) MCB TP 10 Amps "C" curve for Capacitor bank - 03 Nos (k) 3 Pole Capacitor duty Contactor of rating 5 KVAr with in-built NO / NC Auxiliary contact block - 03 Nos (l) Thyristor control Intelligent Power Factor Controller having advanced Micro Controller based Logic, suitable to operate with 3 Phase 415 volts 50 Hz supply. 6 steps, operating by and inclusive of 3 CTs having power fqactor measurement capacity 0.8 (Lag) to 0.8 (Lead) with LCD Display, Provision for automatic CT polarity detection -01 No. (AE / L&T/SCHNEIDER/BCH) (m) Digital type multifunctional meter suitable to read 7 parameters, complete with 3 Nos CT of suitable rating - 1 No l) LED Indicator lamp (RYB) suitable to operate with 240 Volts AC supply -1 Set (D) CONTROL WIRING All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.5 Sqmm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. (e) PROVISION FOR CABLE ENTRY The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables.
Material & Labour for brick masonry valve pit chamber of internal dimension 1100 mm x 1100mm x 900mm depth with 100 mm thick PCC 1:4:8 foundation, 230mm thick brick walls built in CM 1:6, PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in coping 50mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surface(upto 150mm below ground level) including necessary excavation and earth work in any type of soil, MS sheet cover 3.15mm thick alongwith angle iron frame of size 40x40x6mm with locking arrangement and necessary fixing materials like hinges, bolts etc (Valve chamber cover shall be opended in two halves) and painting to MS cover and MS angle frame work with two coats of synthetic enamel paint over one coat of red oxide primer and 2 coats of white wash of the plastered surface of valve chamber both internally and externally (above GL) complete all as specified and directed.
Supply, Commissioning, erecting & testing complete of manufacturer or OEM manufactured, static silent (sound proof enclosure) Disel Engine driven Generating set of capacity 320 KVA confirming to emission limits issued vide GSR 771 (E) dated 11 Dec 2013 and its amendments vide GSR 232 (E) dated 31 Mar 2014, GSR 789(E) dated 11 Nov 2014 and GSR 105(E) dated 17 feb 2015 at Ser No. 95 issued by Ministry of Environment and Forests Government of India , water cooled, 415 volts (AC three phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe complete and suitable for conditions prevalent at Agra (capacity of engine, alternators shall worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5m height), anti-vibration pads complete all as specified and directed, including all feature to comply with latest CPCB guidelines and comprising of followings all as specified and directed:- DIESEL ENGINE : Diesel engine 1500RPM, direct injection, multi cylinders, four stroke, conforming to IS:100001 / ISO3046 / BS: 649 / BS: 5514 amended upto date, for continous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 320 KVA at outdoor atmospheric conditions at Agra (Taking all derating factor into consideration) fitting with the following accessories subject ot the design of manufacturer:- (i) Dynamically balanced fly wheel. (ii) Air cleaner oil bath type (iii) Electronic Governor class 1 A with back up Mechanical governor class 1A Flywheel with starter ring (iv) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level (v) Radiator cooling (vi) Radiator fan with guard
(vii) Vaccum indicator (viii) Fuel filter and fuel houses (ix) Fuel injection pump (FIP) (x) Fan and water pump assesembly (xi) Lub oil filter and pump (xii) Electric starting system with battery charging alternator and axial type started motor including adequate number of high capacity maint free lead acid battery as per manufacturer recommendation including inter connecting cables/leads with terminals complete with starting/stopping switch voltmeter, etc 01 set (xiii) Engine safety shut down system against low oil pressure and high water pressure (xiv) Exhaust gas driven turbo charge (xv) Oil filter (xvi) Lub oil cooler (xvii) Engine main manual with spare part list (xviii) Suitable designed acoustic enclosure as per CPCB regulations (xix) Any other item not included / specified but is a standard design of the manufacturer. Engine insttrument panel : Engine instrument panel shall comprising of the following:- (i) Starting on /off switch. (ii) water temp gauge. (iii) Hour meter cum RPM indicator (iv) Lub oil pressure gauge (v) Lub oil temperature gauge (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure. (viii) Any other item not included/specified but is a standard design of the manufacturer.
ALTERNATOR Alternator shall be self excited, self regulated, brush less for 320 KVA continous operation at the speed of 1500RPM at 415 volts, 50Hz three phase, 4 wire system with advance electronic voltage regulator to ensure high voltage accuracy with +1% with class H insulation and SPDP enclosure directly coupled with engine through flexible couping and conforming to IS : 4722 complete-01 No. Note:- Alternator should be able to deliver output rating at actual site condition. Common fabricated base frame for engine and alternator made from structural channel, jerk proof PCC 1:2:4 mix type B-1 using 20 mm graded crushed stone aggregate in foundation including adequate number of suitable anti-vibration pads all as per manufacture recommendations / instructions is deemed to be included in the unit rate quoted by the contractor. Bottom mounted (or as per manufactures design) steel fuel tank fabricated out of 14 SWG MS sheet of capactiy not less than 12 hrs continous operation inside canopy with fuel level guage, drain plug locking arrangements etc with and including GI pipe connections duly laid as per moderan engineering practice complete all as specifided and directed. Bottom mounted (or as per manufactures design) steel fuel tank fabricated out of 14 SWG MS sheet of capactiy not less than 12 hrs continous operation inside canopy with fuel level guage, drain plug locking arrangements etc with and including GI pipe connections duly laid as per moderan engineering practice complete all as specifided and directed.
Bypass arrangement by providing separate panel made out of 3mm thick CRCA sheet, outdoor type with connecting copper bus bar of suitable size from change over and set of 3 Nos indication lamp for R, Y and B and 2 Nos 4 pole on load change over switch front handle operated of capacity 630 Amp is to be installed near AMF panel complete all as specified and directed. (i) Hour run meter. (ii) Any other item not included/ specified but is a standard design to the manufacturer.
Supply, fabricating and testing of factory mounted cubical Automatic Main Failure panel board out door type with degree of protection IP-55 conforming to IS : 2147, suitable for 320 KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming and outgoing leads / bus bar as approved with and including following accessories all as specified and directed:- (i) Master switch for auto/manual/reset/off-01 No. (ii) Ammeter digital type, of size 96X96 mm with CT's-03 Nos aux supply 230 vlts, AC, acuracyclass 1. (iii) Voltmeter digital type of size 96x96 mm to read 0-500 volts supply 230 volts, accuracy class 1. (iv) Digital frequency meter-01 No aux supply 230 volts, AC (v) Push button start & stop, reset-01 No. (vi) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure. (vi) Battery charger connected to load. (vii) Transformer of adequate rating. (viii) Rectifiers (ix) DC ampere meter and voltmeter. (x) Fault accept / reset push button. (xi) Set of relays and contactor suitable for 320 KVA DG Set for automatic start and automatically shut down of suitable rating and capacity adjustable to 70 to 100% and 2 Nos MCCB 4 pole, 630 Amp, 25 KA fixed on main supply and DG set supply. (xii) Change over switch 630 AMP 4 pole for bypass arrangement DG Set (xiii) Make of AMF control panel shall be as per OEM recommendations. Note for Items No 11.16 & 11.20 (i) All testing arrangement including T&P & consumable items such as fuel, Oil & other connected items required will be carried out by contractor for testing as per CA specification and testing sheet given in this tender documents at no extra cost to the department. (ii) Testing will be carried out in presence of testing officer detailed by CWE (AF) Agra.
Supply & Fixing Crane Electricly Operated OH complete with span 12 to 16 meter, lift 4.5 RM to 6 RM and of capacity 2 tons General Specification a) Type of Crane-Single Girder Crane b) Capacity -2 Ton c) Span-12 MTR. d) Lift-2.75 MTR e) Duty-Class II, Indoor f) Operation-Pendent Operated(remote) Speed : a) Main Hoist Speed-Class II, Indoor b) CT. Speed-Pendent Operated(remote) c) LT. Speed-12.0 mtr. per min. Crane Clearances : a) Head Room (From LT Rail level)-1.5 mtr. b) Side Clearances : i) Left Side-0.25 mtr. ii) Right Side-0.25 mtr. c)Hook Approaches : i) Left Side-0.9 mtr. ii) Right Side-0.9 mtr. Power Supply Reqd : a) Main Supply -415 V. 3 Phase, 50 c/s. A.C. b) Control Voltage-110 V. Single Phase, A.C.
Motors : a) Main Hoist Motor-2.0 HP (Sq. Cage) b) CT. Motor-0.5 HP (Sq. Cage) c) LT. Motor-1.0 HP (Sq. Cage) Crane Crane Duty Make : CROMPTON / BBL / Marathon Gear Boxes : a) Main Hoist Gear Box-Helical b) CT. Gear Box-Helical & c) L.T. Gear Box Helical x 2 Nos. Brakes : a) Main Hoist Brake-EM type b) L.T. Brake Rope Drum: a)Main Hoist R. Drum-SEAMLESS PIPE Hook Block : a) Main Hoist Hook Block-2 TON. Wire Rope : a) Main Hoist Wire Rope-10 MM 4 FALL Wheel Assly : a) CT. Wheels-125 mm dia single Flange b) LT. Wheels-200 mm dia Double Flange
Bearings : a) CT. Bearings-6006 Spherical Roller type b) LT. Bearings-22208 Spherical Roller type Crane Structure a) End Carriages-Fabricated from Channel. b) Girder- Girder Electricals 1.Panel Boxes- Control components of L&T / Schneider / Siemens make. Protection / Safety Device - Hoist CT. - To be Provided LT. Ol relay - To be Provided MCCB - To be Provided Limit Switches To be Provided VVVF Drive - To be Provided for all Motors Cable for Crane Wiring PVC insulated Flexible Copper Cable of approved make
Supply & fixing A standalone steel frame mounted crane having 2 Nos manually operated chain pully block (each of lifting capacity 1 Ton and lifting height 2.75 RM). Note : The tension load test stand is used to perform the ground test of the capital APR 3 air refuelling POD to be tested will be installed on the TLTS hang section using the provided sling. (a) Hang structure (b) Chain Hoist Assembly (Qty 2) (c) Slim (d) Carriage Note : i) The item should be fabricated identical to the similar type of existing crane structure available in the same complex. Ii) Contractors are suggested to visit the work site to evaluate the quantum of materials and labour involved in the work before quoting the rate for this particular item.
Supply, Installation, testing & commissioning of end-suction & top-discharge, back pullout type centrifugal pumps for chilled water re-circulation-03 Nos (2Working +1Standby), complete with cast iron body, bronze impeller, mechanical seals, TEFC fan cooled type, squirrel cage high efficiency, IE3 class induction motor, base plate, mounting channel frame, accessories and fittings i.e. mechanical seal, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting of the following specifications, suitable for operation on 415 V ±10%, 50Hz, 3 Phase AC supply. The Pumps shall be insulated with expanded polysterene (TF quality) of suitable thickness but not less than 25 mm. The pump shall be suitable for given duty point as mentioned under :- [a] Capacity : 114 US GPM approx [b] Head: 20 RM [c] Impeller: Bronze metal [d] Approximate Motor Rating: 3 HP Note : 1. Pumpsets will be arranged in 2Working+1Standby configuration. Neccessary plumbing work will be done accordingly 2. Contractor will provide calculation of Head and Hp of Pump. In case of deviation in Hp more than specified in tender, financial adjustment will be done through DO.
Supply, Installation, testing & commissioning of end-suction & top-discharge, back pullout type, centrifugal pumps for condensor water re-circulation-03 Nos (2Working+1Standby), complete with cast iron body, bronze impeller, mechanical seals, TEFC fan cooled type, squirrel cage high efficiency, IE3 class induction motor, base plate, mounting channel frame, accessories and fittings mechanical seal, drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mounting of the following specifications, suitable for operation on 415 V ±10%, 50Hz, 3-Phase AC supply. [a] Capacity : 160 US GPM approx [b] Head : 20 RM [c] Impeller: Bronze metal [d] Approximate Motor Rating : 5 HP Note : Pumpsets will be arranged in 2Working+1Standby configuration. Neccessary plumbing work will be done accordingly. 2. Contractor will provide calculation of Head and Hp of Pump. In case of deviation in hp more than specified in tender, financial adjustment will be done through DO.
Supply, Installation, testing & commissioning of PAN-type humidifier capacity not less than 45 litre per hour evaporation rate, made out of stainless steel of grade SS-304 sheet welded construction with unitized stainless steel reservoir, divided into two chambers from inside having 25 mm thick fiberglass insulation cladded with aluminum foil, snap-acting humidistat, support legs for free-standing or wall hanging brackets for wall-mounting, factory mounted & wired humidifier control cabinet, steam outlet nozzle, water make-up, drain, over-flow, quick fill connections, immersion heaters made of stainless steel, terminal blocks suitable for field power and control wiring and safety thermostat complete.
Supply, Installation, testing & commissioning of SS 304 shell type vertical electric hot water generator suitable for 45 KW heat output for hot water output with ater inlet at 45º C and outlet 50º C, working pressure 100 PSIg (tested for 350 psig pressure), having 50 mm thick insulation of resin bonded with fiber glasswool with 0.63 mm aluminium cladding, thermostat for individual step, digital thermometer for inlet & outlet pipes, pressure gauge with ball valve for inlet & outlet pipes, SCR based stepless linear controller, float switch, audio/visual alarm for low water level, auto vent audio/visual alarm for high temperature, pressure relief valve, door switch, safety thermostat, etc. complete as specified and directed. Note : HWGs will be arranged in 1Working+1Standby arrangement
Supply, Install, testing and commissioning centrifugal monoblock pump for pumping hot water from HWG to heating coil in AHU with energy efficient motor confirming to IS : 12615. The pump shall be suitable for given duty point [a] Capacity: 76 US GPM approx [b] Head: 20 RM [c] Impeller: Bronze metal, Shaft High Tensile steel, Pump Mpotor body : CI [d] Approximate Motor Rating: 2.5 HP Note : 1. Pumpsets will be arranged in 1Working+1Standby configuration. Neccessary plumbing work will be done accordingly 2. Contractor will provide calculation of Head and HP of Pump. In case of deviation in Hp more than specified in tender, financial adjustment will be done through DO. 3. Rate quoted is inclusive of foundation as per OEM recommendation
Supply, Installation, testing & commissioning of MS ERW Class 'C' HOT water piping with all necessary fittings i.e bends, tees, reducers, flanges, structural support, wooden blocks, air-purge valves, drain-valves thermally insulated with Expanded polystyrene (TF quality) 50mm thickness finished with aluminium sheets of 0.5mm thickness complete as specified & as required at site.
100 mm nominal bore
80 mm nominal bore
65 mm nominal bore
Supply, Installation, testing & commissioning of MS Class 'C' INSIDE PLANT ROOM conforming to IS: 1239 chilled water piping, cut to required length and installed with welded joints, including all necessary fittings such as elbows, tees, bends, reducers, flanges, supports clamps, vibration isolators duly insulated with expanded polystyrene (TF quality) min density 20 Kg per cum, min thickness 50 mm thick, finished with 24 gauge aluminimum sheet over vapour barrier of 120 gm per Sqm polythene sheet with 50 mm overlap, tied down with lacing wire with type 3 grade 1 roofing feltstrip at joints incl making good to damages to building as per adjoining surface
100 mm nominal bore
80 mm nominal bore
Supply, Installation, testing & commissioning of 100 mm MS Class 'C' OUTSIDE PLANT ROOM conforming to IS : 1239 chilled water piping, cut to required length and installed with welded joints, including all necessary fittings such as elbows, tees, bends, reducers, flanges, supports clamps, vibration isolators duly insulated with expanded polystyrene (TF quality) min density 20 Kg per cum, min thickness 50 mm thick, finished with 24 gauge Galvanised steel sheet over vapour barrier of 120 gm per Sqm olythene sheet with 50 mm overlap, tied down with lacing wire with type 3 grade 1 roofing feltstrip at joints incl making good to damages to building as per adjoining surface
Supply, Installation, testing and commissioning of MS ERW Class 'C' conforming to IS : 1239 condenser water piping with all necessary fittings i.e. bends, tees, reducers, flanges, , laid underground with two coats of tarfelt each having thickness of 2mm and stick with hot bitumen outside the building Note for 11.30 to 11.38 : All pipes, pipe support, structure shall be painted with two coats of synthetic enamel paint of color as per colour coding over one coat of red oxide primer with lettering and marking of flow in white paint
125 mm bore
100 mm bore
Supply, Installation, testing and commissioning of PN 1.6 rated butterfly valves of integral moulded design, duly insulated with companion flanges, nuts, bolts, gaskets with cast iron body, seat of black nitrile rubber, nylon coated SG iron disc, PTFE coated SS (AISI 410) shaft etc as required, conforming to BS: 5155, MSS SP 67 & API 609, designed to fit without gaskets between mating flanges, suitable for flow in either direction and seal in both directions complete.
(a) 50 mm nominal bore insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM polythene faced hessian cloth with 50 mm overlapped and 26 mm aluminium cladding complete.
(b) 80 mm nominal bore insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM polythene faced hessian cloth with 50 mm overlapped and 26 mm aluminium cladding complete.
Supply, Installation, testing & commissioning of Y-type strainer with CI/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets duly insulated with 50 mm thick TF quality EPS & covered with 15 mm thick rendering in cement sand mortar in 1:4 complete.
(a) 80 mm nominal bore insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM plythene faced hessian clot with 50 mm overlap and 26 mm aluminium cladding complete.
125 mm nominal bore without insulation
100 mm nominal bore without insulation
Supply, Installation, testing and commissioning of Wafer Swing Check type PN - 1.6 rated Non- Return Valve with cast iron body, flanges type joints with rubber gaskets with insulation required number of nut or bolts complete.
(a) 100 mm nominal bore without insulation
(b) 80 mm nominal bore insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM plythene faced hessian clot with 50 mm overlap nd 26 mm aluminium cladding complete.
Supply, Installation, testing & commissioning of paddle type water flow switch, having operating pressure 1000 KPa, withstand pressure 91750 KPa, insulation resistance over 100 Ω (OHM), withstand voltage 1500 Volt AC for 1 minute, contact point life of 1000 K cycles and bellows life 500 K cycles complete with control wiring and accessories etc as specified in particular specifications suitable to control approximate maximum flow rate of 115 US-gpm and installation in 80 mm chilledwaterline insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM plythene faced hessian clot with 50 mm overlap nd 26 mm aluminium cladding complete.
All as above but Water Flow Switch suitable to control approximate maximum flow rate of 160 US-gpm and installation in 100 mm condensor water line without any insulation complete. Note : for item No. 11.51 & 11.52:.In case of requirement of flow switch of flow rate varying more than +10% as specified in the tender, financial adjustment will be done through DO.
Supply, Installation, testing and commissioning of 2-way, globe type, PN-1.6 rated, BALANCING VALVE as per following specification. Nominal pressure 16 bar Medium Temperature -10~ +110 Maximum Body Material IS:210, FG 220 Cast Iron Stem Material ASTM A276,GR SS 410 Disc Material Stainless steel Disc Hand Wheel Cast Iron Leakage Rate No visible leakage Medium Type Water Flange standard ISO7005-1 (GB/T 9113) Shell Test pressure 24bar Seal Test pressure 17bar
(a) 100 mm nominal bore without insulation
(b) 80 mm nominal bore insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM plythene faced hessian clot with 50 mm overlap nd 26 mm aluminium cladding complete.
Supply, Installation, testing and commissioning of Cast Iron 3-way mixing / Tempearature control valve, 80 mm Nominal Bore insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM plythene faced hessian clot with 50 mm overlap and 26 mm aluminium cladding suitable for operation up-to 10 bar, with electronically operated actuator for AHUs. Water flow through the valve shall be regulated by rotation of brass slipper between the main and the bypass ports; it shall be possible to manually rotate the brass slipper through 360° and interchange the main and the common ports, to facilitate installation at site. All internals of the valve shall be rust-proof and the 'O' ring shall be of elastomeric insulation. The valve actuator shall be of electronic type with DC motor, the actuator's angle of rotation shall be 90°, it shall be without any limit switches and shall be overload-proof. It shall have an indicator to indicate the position and push-button to disengage the gear train for manual operation complete.
S & F of CL 150 # rated 25 mm ball valve, designed & manufactured as per IS: 9890 (1981) and tested as per BS: 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection with accessories complete as specified.
Supply, Installation, testing & commissioning of 100 mm dial type bourdan pressure gauge of appropriate range and SS isolation valves & other fitting in chilled water, hot water and condensor water line complete.
Supply, Installation, testing & commissioning of set of 150 mm dial type temperature gauge of appropriate range with thermowell and SS valves & other fitting in chilled water, hot water and condensor water line complete.
Supply, Installation, testing & commissioning of 25 mm Nominal bore auto air-purge valve with all fittings viz bend, elbow, nipple and drain valve for chilled water piping complete.
Supply, installation, testing & commissioning of 50 mm Nominal Bore auto air-vent valve with all fittings viz bend, elbow, nipple and drain valve for chilled water piping complete.
Supply, Installation, testing & commissioning of 65 mm Nominal Bore pot-type strainer with CI / MS body, bolted cover, flanged ends, basket of brass / bronze / SS wire mesh with flanges, nuts-bolts, gaskets complete.
Supply & Fixing GI medium grade pipe with all fittings
Supply & Fixing galvanised iron water tubing 32 mm bore with fittings complete for insulated for draining water complete.
Supply & fixing pressure gauge plug type for 50 mm to 125 mm bore pipe line with sealed complete .
Supply & fixing screwed plugs with seal for 50 mm to 125 mm bore pipe line complete.
Supply, Installation, testing & commissioning of square / rectangular supply air diffusers / grills of extruded powder coated aluminum sections with duly powder coated with aluminium volume control; damper, anti smudge ring and removable core complete.
Supply, Installation, testing & commissioning of square / rectangular return air diffusers / grills of extruded powder coated aluminum sections without damper complete.
Supply, Installation, testing and commissioning of fire and smoke damper of required size complete The fire dampers shall be motorised and spring return type so as to close damper automtically in event of power failure. Damper should be complete with electronic temperature sensor and electrically operated actuator and interconnecting wiring between AHU and damper complete.
Fire Damper
Actuator with smoke fire sensor
Note for Item No. 11.67-11.71 1. GI sheet will conform to IS 277. Rate quoted for ducting is inclusive of all accessories, hanging arrangement required for duct work 2. Before executig duct work, design and drawings will be get approved from Accepting Officer.
S & F closed cell Class O, elastomeric nitrile rubber 19 mm thick thermal insulation for SA / RA ducts insulation with aluminum foil 0.1 mm laminated on one side, having thermal conductivity not exceeding 0.037 W / mK at mean temperature of 20° C as per EN 12667, density (without the foil ) between 40 to 55 kg / cum applied using manufacturer recommended rubber based adhesive complete.
Supply & Fixing under deck insulation with resin bonded fibre glass wool conforming to IS : 8913, density 24 Kg per cub meter, 60 mm thick, wrapped in 200 + 20 GSM virgin polythene bags fixed to ceiling with metallic cleat 50x50x3 mm at 60 cm ctentre to centre and steel wire mesh of 12.5 mmx24 G wire complete.
Supply & Fixing XLPE insulated stranded copper conductor armored cables / wires of 1100 Volt grade, laid in trenches / wall Including cost of all crimping lugs and shingle compression glands, cable sockets insulating tape, sealing compound complete.
25 Sqmm x 4 Core Copper conductor cable (For HWG)
4 Sqmm x 4 Core Copper conductor cable (For pumps)
Supply, installation, testing and commissioning of floor mounted, indoor duty cubicle & compartmentalized, front access type, medium voltage, manufactured by CPRI approved panel manufacturer, factory fabricated, IP-42 powder coated, suitable for operation on 415 Volts 3 phase 4 wire 50 Hz, AC supply complete with all inter connections and consisting of all accessories like aluminum Bus Bar (min 500 A capacity), Indicating lamps, Push buttons, CTs, Digital Ampere, Voltage, Frequency & KWH meter, Danger notice Plate, Lifting Hooks, Feeder Name Plates suitable for the following feeders electric panel of dust and vermin proof construction, front openable doors and shutters with locking arrangement, made out of 14 SWG (2 mm thick) CRCA sheet steel, front openable, single door system lockable / openable with "U' type gasket to make the inner shell completely vermin proof having chromium plated locks (2 Nos in each compartment). All control wiring shall be with not less than 1.5 Sqmm multi-stranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75x75x5 mm duly pained with zinc based primer. A detachable predrilled gland plate of thickness 3.15 mm should be used at the bottom, Note : The Panel shall be of suitable size to accommodate all the accessories mentioned below, installed on Pedestal made out of angle iron of size 50 mm x 50 mm x 6 mm & earth work, PCC foundation, suitable cable glands for cable entry) [i] Incoming Feeder: MCCB 320 Amp, Four pole 415 Volt breaking capacity 36 KA, Fixed thermal and magnetic setting, Ics=Icu with spreader link [ii] Outgoing Feeders: [a] For water-cooled chillers: MCCB 63 Amp Four pole 415 Volt breaking capacity 16 KA Fixed thermal and magnetic setting, Ics=Icu with spreader link-04 Nos (2Working +1Standby +1 spare) (b) For Hot Water Generator : 100 A ,16 KA , FP MCCB ,415 Volt fixed with thermal and magnetic setting , ICS=ICU with spreader link -02 nos (01 Working +01 standby) [c] For AHU MCCB 40 Amp Four pole breaking capacity 10 KA Fixed thermal and magnetic setting, Ics=Icu with spreader link - 01 No [d] For cooling towers: MCB SPN 20 Amp breaking capacity 10 KA 230 Volt - 04 Nos (2 Working + 1 Standby + one spare) [e] For chilled / condenser water / hot water pump: MCB Four pole 10 Amp 415 Volt breaking capacity 10 KA - 08 Nos
Supplying, hoisting and fixing PVC expansion tank of capacity 500 litre duly insulated with 50 mm thick expanded polystyrene of density 20 Kg per Cum and finished with GI chicken wire mesh and two coats of cement sand plaster suitably 2 coats painted with complete with inlet, outlet, drain and over flow connections with valves , float valves complete with m,aking necessary water connections complete.
Supplying, hoistingh and fixing HDPE water storage tank 5000 Litre capacity ISI marked cylindrical type with inlet, outlet, drain and over flow connections with float valves 25 mm dia pipe PVC ball of duly inter coneected connected to each other with 50 mm bore length not less than 1 RM to be installed on suitable RCC / brick staging of 4 RM height complete all as specified.
Supplying, hoistingh and fixing HDPE water storage tank 02 Number 5000 Litre capacity ISI marked cylindrical type with inlet, outlet, drain and over flow connections with float valves 25 mm dia pipe PVC ball of duly inter coneected connected to each other with 50 mm bore length not less than 1 RM to be installed on suitable RCC / brick staging of 4 RM height complete all as specified.
Supply & Fixing Toilet paper holder with flat recessed type stainless steel fixed on walls with steel screws or cleats complete all as specified.
Outsourcing of services for operation of central AC plant 75 TR and DG set 320 KVA with one operator in one shift of 08 hours ( including saturdat , Sunday and holidays )at new POD complex bldg in 78 SQN at af stn agra comprising of the following equipments complete all as specified and directed:- (a)Chiller plant of capacity 2X37.5 TR working and 01X37.5 Standby. (b)Chiller water /conderser water circulating pimps with electri motor -06 Nos (c)Hot water generator set 55 KW. (d)Hot water pump set (one working and one standby) (e)Air Handing Unit -01 Nos (f)Humidifier (g)Cooling tower (02 working and 01 standby) alongwith sprinkler pumps and tower pumpset. (h)DG set 320 KVA with AMF panel and LT Panel -01 set. Note :- (i)Contractor shall maintain adequate temperature and relative humidity 23+ 2 degree C & 60+ 20%RH as per design parameter of each AC plant. (ii) Complete AC Plant , Pre metallic filters , cooling towers and surrounding area is also contractors resposibility . (iii)Daily routine checking of electric connections of all components , refrigerents gas leakage etc if any in case of any major repair / breakdown same shall be brought to the notice of JE/Engr-in-charge. (iv)All operator should be ITI holder with two year experience in the operation of AC plant. (v)FOL and lubricants shall be issued by the department from AGE E/M (AF) Tech area agra store ysrd under schedule 'B' Free for filling and it will be contractors responsibility for filling of oil /lubricants in the fuel tank of DG sets all as specified and directed.
(vi)Empty containers shall be returned by the contractor to the MES store at Agra. (vii)All operator will wear proper uniform as approved by GE . (viii)Contractor will employ additional manpower for rest/leave period. (ix) LT panel recovery on account of non operation of installation/absent of operators from duty etc respective cluse of department specifications shall be applicable . (x)Proper handing/taking of operator to be done on shift rotation and operator should not leave the plant till arrival of next operator . (xi)Insurance of all oprator shall be contractors responsibility. (xii)Stationay for maintenance of records and documentation shall be contractors responsibility ( Dialy Log shteet , Attendance register , Wages register etc). (xiii)Contractor submit the nominal roll of persons to be employed alongwith qualifications / experiencce certificates , police verification , identification certificate to the engr-in-charge within one month of commencement of plant operation. (xiv)The contractor shall operate the DG sets and connected panels for proper functioning of AC plant at the time of power failure and to maintain the system functional as per requirenment. NOTE :- Rate quoted by contractor under this item shall be applicable for the period of manning and operation just after the completion of phase-I and start of Phase-II upto 335 days .
Outsourcing of services for operation of central AC plant 75 TR and DG set 320 KVA with one operator in one shift of 08 hours ( including saturdat , Sunday and holidays )at new POD complex bldg in 78 SQN at af stn agra comprising of the following equipments complete all as specified and directed:- (a)Chiller plant of capacity 2X37.5 TR working and 01X37.5 Standby. (b)Chiller water /conderser water circulating pimps with electri motor -06 Nos (c)Hot water generator set 55 KW. (d)Hot water pump set (one working and one standby) (e)Air Handing Unit -01 Nos (f)Humidifier (g)Cooling tower (02 working and 01 standby) alongwith sprinkler pumps and tower pumpset. (h)DG set 320 KVA with AMF panel and LT Panel -01 set. Note :- (i)Contractor shall maintain adequate temperature and relative humidity 23+ 2 degree C & 60+ 20%RH as per design parameter of each AC plant. (ii) Complete AC Plant , Pre metallic filters , cooling towers and surrounding area is also contractors resposibility . (iii)Daily routine checking of electric connections of all components , refrigerents gas leakage etc if any in case of any major repair / breakdown same shall be brought to the notice of JE/Engr-in-charge. (iv)All operator should be ITI holder with two year experience in the operation of AC plant. (v)FOL and lubricants shall be issued by the department from AGE E/M (AF) Tech area agra store ysrd under schedule 'B' Free for filling and it will be contractors responsibility for filling of oil /lubricants in the fuel tank of DG sets all as specified and directed.
(vi)Empty containers shall be returned by the contractor to the MES store at Agra. (vii)All operator will wear proper uniform as approved by GE . (viii)Contractor will employ additional manpower for rest/leave period. (ix) LT panel recovery on account of non operation of installation/absent of operators from duty etc respective cluse of department specifications shall be applicable . (x)Proper handing/taking of operator to be done on shift rotation and operator should not leave the plant till arrival of next operator . (xi)Insurance of all oprator shall be contractors responsibility. (xii)Stationay for maintenance of records and documentation shall be contractors responsibility ( Dialy Log shteet , Attendance register , Wages register etc). (xiii)Contractor submit the nominal roll of persons to be employed alongwith qualifications / experiencce certificates , police verification , identification certificate to the engr-in-charge within one month of commencement of plant operation. (xiv)The contractor shall operate the DG sets and connected panels for proper functioning of AC plant at the time of power failure and to maintain the system functional as per requirenment. NOTE :- Rate for manning and operation to be quoted by contractor under this item shall be applicable after completion of item no. 11.83 of BOQ (Next 335 days).
S uppy & Fixing Health faucet ABS Body chromium plated suitable for 15 mm dia pipe with 1200 mm long flexible water tube and ABS wall hook including making connections and fixed in position on walls or tiles space with steel screws complete in all respect as specified.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .