| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹13.4 L+₹97,505 (7.88%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹14.6 L+₹2.2 L (17.9%)Rejected-Finance 340 11 M S NATIONAL ENGINEERING CORP 340 11 SATTI STREET ROORKEE ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹15.3 L+₹2.9 L (23.4%)Rejected-Finance | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹18.3 L+₹5.9 L (47.5%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹15.5 L
EMD Value
₹31,000
Closing Date
9 Mar 2020, 6:00 pmClosed
SHRI SS MALVIYA IDSE EE GARRISON ENGINEER NW
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802.
8264/E8
2020_MES_315293_2
8264/E8
Open Tender
Civil Works
Item Rate
180 days
VASCO
Class E Category b i
8 documents required · 8 mandatory
₹500
Yes
GE NW VASCO
₹31,000
Yes
19 Mar 2020
12 Feb 2020
11 Mar 2020
12 Feb 2020
9 Mar 2020
25 Feb 2020
13 Feb 2020 - 24 Feb 2020
Amount
Taking down aluminium/copper point wiring (light, socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials (credit for above items should be made as per conditions separately) and making good the disturbed surface all as directed .
Taking down submain wiring Aluminium/ copper of any size including earth continuity conductor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and directed.
Taking down existing DB TPN 4 way and DB SPN 8 way of any capacity and size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
M&L Point wiring complete with 1100volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor as earth conductor and connected to earth dolly, including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches, sockets etc concealed on wall complete all as specified and directed.
(a) One light point / fan point controlled by one switch
(b) One call bell point controlled by bell push
(c) one 3 pin socket outlet, on the same board socket 5 Amps point with other switches with cable 1.5 sqmm
(d) one 3 pin socket outlet, 5 Amps on independent board.
(e) for one light point controlled by two, two way switches.
All as per item No 4.00 above but complete with 1100volt grade PVC insulated unsheathed multistranded wire with 2.5 sqmm copper cable through casing and capping of suitable size and one run of 1.5 sqmm copper cable as earth continuity conductor including connecting with earth dolly for 15 Amps socket outlet on independent board.
S&F switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
S&F switch piano, flush type single pole, two way 15 Amp complete all as specified and directed .
S&F in repair switch socket combination 2 in 1, 3 pin 5 Amp and 15 Amp combined flush type universal complete all as specified and directed .
S&F in repair Switch socket combination 5 in 1 pin 5 / 16A, flush type
S&F in repair ceiling rose 3 terminal 230 volts, PVC polycarbonate, isolated body complete all as specified and directed.
S&F in repair Ding dong bell, AC, 230 volts, single phase, 50 HZ complete all as specified and directed
S&F in repair bell push 5 Amp flush type complete all as specified and directed.
S&F in repair lamp holder, insulated body, with back plate for batten fitting complete all as specified and directed.
M & L for submain wiring complete with 1100volt grade PVC insulated unsheathed multistranded cable with 1100volt grade PVC insulated unsheathed multistranded 02 run of 04sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing & capping in Ivory / Grey /white colour medium grade etc fixed on wall/ceiling including provision of 01 run of 4 sqmm PVC unsheathed copper conductor and connected to earth dolly complete all as specified and as directed. Note :- 02 run of 04 sqmm and 01 run of 2.5 sqm including 01 run of PVC casing & capping will be measured as one length complete all as specified and directed .
M & L for submain wiring complete with 1100volt grade PVC insulated unsheathed multistranded cable with 1100volt grade PVC insulated unsheathed multistranded 02 run of 06 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing & cping in Ivory/Grey/white colour medium grade etc fixed on wall/ceiling including provision of 01 run of 4.0 sqmm PVC unsheathed copper conductor and Connected to earth dolly complete all as specified and as directed. Note :- 02 run of 06 sqmm and 01 run of 4.0 sqm including 01 run of PVC casing & capping will be measured as one length complete all as specified and directed.
S&F MCB DB SPN double door 8 way sheet metal enclosure SPN 240 V 50 Hz horizontal with IP-43 degree protection complete all as specified and directed.
S&F MCB DB TPN double door 4 way 415 volts 50 Hz horizontal with IP-43 degree protection complete all as specifed and directed
S&F in repair MCB TPN 'C' series 63 Amp, 415 volts, 50 Hz, 10 KA complete all as specified and directed
S&F in repair MCB 'C' series SP 06 to 32 Amp, 230 volts,50Hz,Breaking Capacity 10 KA complete all as specified and directed
S& F In repairs 'C' series 20 to 32 Amp SPN MCB complete all as specified and directed
M&L in repair for RCCB , DP, 25 Amp, 30 mA, 230 volts, 50 HZ, 10 KA breaking capacity complete all as specified and directed .
Supply and fix in repairs MCCB 4 Pole, current rating 100 Amp, Adjustable thermal setting breaking capacity 25 KA at 415V, 50Hz.
S&F in repair deluxe fan regulator electronic stepped type 230 volts 50 Hz complete all as specified and directed
S&F in repair Hylum sheet top cover 3 mm thick for fixing switches, sockets, fan regulators etc including cutting into suitable sizes all as specified and directed .
Fixing only LED light fitting of any wattage domestic type including provision of neccessary PVC blocks 2 Nos for fixing on wall/ceiling and connecting up with twin core twisted flexible copper cable complete all as directed. Note :- Item should be supplied under schedule B store free for fixing
M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized earth wire 4 mm dia by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion including taking out old earthing.
sapna enterprises
NATIONAL ENGINEERING CORPORATION
DOGRA ELECTRICALS
pk janardhanan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .