Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC MAIN ROAD OBEDULLAHGUNJ RAISEN M P 464993 | OBEDULLAHGUNJ | RAISEN | MADHYA PRADESH | 464993 | ₹1.5 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹1.5 Cr+₹3.3 L (2.24%)Rejected-Finance | ₹1.5 Cr+₹3.3 L (2.24%) | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹1.5 Cr+₹7.2 L (4.89%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹1.5 Cr+₹7.2 L (4.89%) | L3 | Rejected-Finance Other than Lowest |
| 4 | L4₹1.6 Cr+₹17.6 L (12.1%)Rejected-Finance | ₹1.6 Cr+₹17.6 L (12.1%) | L4 | Rejected-Finance Other than Lowest |
| 5 | L5₹1.7 Cr+₹22.7 L (15.5%)Rejected-Finance | ₹1.7 Cr+₹22.7 L (15.5%) | L5 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹2.4 L
Closing Date
26 Jul 2022, 6:00 pmClosed
CHEIF ENGINEER LEH
Headquarters Chief Engineer Leh Zone C/o 56 APO Pin-901205
PROVISION OF 03 x 437.5 KVA DG SETS AT DIV CAMP IN KIARI UNDER GE 860 EWS
2022_MES_526291_1
180087
Open Tender
Electrical and Maintenance Works
Item Rate
672 days
GE 860 EWS
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
GE 860 EWS KARU
₹2.4 L
Yes
14 Sept 2022
25 May 2022
29 Jul 2022
25 May 2022
26 Jul 2022
5 Jul 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m depth for laying of cable and getting out in hard/dense soil complete all as specified and directed.
Returning filling incl spreading watering and well ramming in layers not exceeding 25cm in hard and dense soil.
Removing excavated material not exceeding 50 mtrs and depositing where directed at a level n. exc 1.5mtr above the starting point.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches complete all as directed by Engr-in-Charge. Note:- Only punned thickness i.e 18cm shall be measured and paid.
Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified.
Supply and fixing tube Light grade galvanized with all fitting and fixed complete to walls/ poles/ ceiling or laid in floor of size 50 mm bore for the protection of Underground cables including dismantling/ taking out old, unserviceable one complete all as specified and as directed by Engr-in-Charge.
Supply and fixing tube Light grade galvanized with all fitting and fixed complete to walls/ poles/ ceiling or laid in floor of size 100 mm bore for the protection of Underground cables including dismantling/ taking out old, unserviceable one complete all as specified and as directed by Engr-in-Charge.
Material and Labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 400 Sqmm 3.5 Core, laid in trenches, ducts along the walls, through pipes,or fixed on pole etc completeall as specified and as directed by Engr-in-Charge. Make: PolyCab, Gloster & Havells.
Material and Labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 240 Sqmm 3.5 Core, laid in trenches, ducts along the walls, through pipes,or fixed on pole etc complete all as specified and as directed by Engr-in-Charge. Make: PolyCab, Gloster & Havells.
Material and Labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 150 Sqmm 3.5 Core, laid in trenches, ducts along the walls, through pipes,or fixed on pole etc complete all as specified and as directed by Engr-in-Charge. Make: PolyCab, Gloster & Havells.
Material and Labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 120 Sqmm 3.5 Core, laid in trenches, ducts along the walls, through pipes,or fixed on pole etc complete all as specified and as directed by Engr-in-Charge. Make:PolyCab, Gloster & Havells.
Material and Labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 95 Sqmm 3.5 Core, laid in trenches, ducts along the walls, through pipes,or fixed on pole etc complete all as specified and as directed by Engr-in-Charge. Make: PolyCab, Gloster & Havells.
Material and Labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 50 Sqmm 3.5 Core, laid in trenches, ducts along the walls, through pipes,or fixed on pole etc complete all as specified and as directed by Engr-in-Charge. Make:PolyCab, Gloster & Havells.
Material and Labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 35Sqmm 3.5 Core, laid in trenches, ducts along the walls, through pipes,or fixed on pole etc complete all as specified and as directed by Engr-in-Charge. Make:PolyCab, Gloster & Havells.
Material and Labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 25Sqmm 4 Core, laid in trenches, ducts along the walls, through pipes,or fixed on pole etc complete all as specified and as directed by Engr-in-Charge. Make: PolyCab, Gloster & Havells.
Material and Labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 16Sqmm 4 Core, laid in trenches, ducts along the walls, through pipes,or fixed on pole etc complete all as specified and as directed by Engr-in-Charge. Make: PolyCab, Gloster & Havells.
Material and Labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 10Sqmm 4Core, laid in trenches, ducts along the walls, through pipes,or fixed on pole etc complete all as specified and as directed by Engr-in-Charge. Make: PolyCab, Gloster & Havells.
Material and Labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 10Sqmm 2Core, laid in trenches, ducts along the walls, through pipes,or fixed on pole etc complete all as specified and as directed by Engr-in-Charge. Make: PolyCab, Gloster & Havells.
Supply, installation, testing and commissioning of Diesel engine driven Generating set, self excited, self regulated, brushless AC generator of Capacity 400 KVA, 415 Volts, 3 Phase, 0.8 power factor, 50 Hz, 1500 RPM at NTP with silencer pipe , acoustic enclosure with sound proof canopy and sound level should be 75 DB (A) at a distance 1 Mtrs as per ISO 8528 Part-1, exhaust silencer pipe protected with asbestos rope independently supported from engine to outside power house up to 1 mtr, AVM pads, PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) foundation for DG set as per manufacturer design, battery start with suitable cable for connection up to panel board . The DG Set will be capable of operating in Temp range of (-) 35 degree centigrade to (+) 35 degree centigrade at an altitude of 4250 mts above mean sea level (MSL) complete with and including the following:-
ALTERNATOR : Alternator rating 400 KVA, 3 phase, 50 cycles, 415 volt, 4 wire supply, 0.8 power factor, running @ 1500 RPM self excited, self regulated, mounted on a strong fabricated steel frame, suitable for mounting on a permanent foundation to be coupled with above engine. The alternator shall be conforming to BS 2613/5000 and shall be in position to generate supply with Voltage regulation within ± 1% tolerance. The alternator will be suitable for tropical climate. Make:- Kirloskar/cummins Electric/Greaves cotton
DIESEL ENGINE : Vertical diesel engine of suitable capacity, naturally Coolent Cooled, closed circuit as per BS-649 or IS-1002 direct injuction type turbo charged Electric starting system having rated speed 1500 RPM. Make:- Kirloskar/cummins Electric/Greavescotton The DG set Shall be capable for running 24 hrs continuously with 10% over loading for one hour in every 12 hours as per BS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection, cold starting and equipped with all standard fitting as per manufacture's recommendations and mounted on common base frame with following fittings :-
(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturer's instructions Note:- Rate quoted by contractor shall be inclusive of all required civil works as per recommendation of OEM
(b) Cooling system Coolant cooled type (Use min DAFC 50%)
(c) FUEL SYSTEM : Fuel injection system with fuel injector, fuel injector pump/governer electronic type fuel filter and fuel hose.
(d) LUB OIL SYSTEM : Lub oil pump,Electric motor driven and lub oil filter.
(e) AIR INTAKE SYSTEM : Air intake manifold and air cleaner dry type.
(f) GOVERNER : Electronic Governer.
(g) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC battery (12 volt, 180 AH battery 2 Nos, Maint free charging alternator with regulator battery as per manufacturer's design, copper leads with lugs of adequate size complete with initial charging fly wheel ring and start and stop push button.
(h) Safe Controls for Engine low lub oil pressure ,high water temp, over speeding of engine and battery charging voltage display.
(j) GENERATOR MONITORING PANEL : Comprising of following :-
(i) Microprocessor based genset controller for metering, monitoring, governing and protection.
(ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown)
(iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (iv) Data logging : Engine hours, control hours, engine starts and recent fault codes. (v) Certification: Certificates to meet the requirements of revelant ISO, CE, CSA and other equivalent standards
(k) ACCESSORIES: AVM Pads built or separately mounted to manufacturer base frames.
(l) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.
(m) EXHAUST SYSTEM : Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as directed.
(n) FUEL TANK: Daily service fuel tank of capacity suitable for 12 hours continuous operation made out of 3 mm thick (heat retardant) sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity and connected pipe line should be installed with in built tank inside the acoustic enclosures inclusive of the cost of DG set and is as per manufacturer design.
(o) . ACOUSTIC ENCLOSURE : Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet steel will provide easy access for maintenance, repairs and operation, be designed to meet MoEF/CPCB Norms. The enclosure is custom built to suit conditions, with the following features:-
(i) Custom built product for various Equipments, which ensure the optimum performance.
(ii) Rugged in construction maintenance free and modular designs which facilitate easy at site.
(iii) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality fire retardant acoustic insulation materials to be used for maximum noise absorption. Acoustic layers are supported by perforated sheets.
(iv) Sheet metal components of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action.
(v) Special paint treatment with pure polyester powder / epoxy to be provided for better weather resistance.
(vi) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently.
(vii) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to used.
(viii) Working space is to be provided around the equipment for easy maintenance / repairs.
(ix) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per the requirement.
(x) A see through transparent window (glass or acrylic) in front of engine panel to provided for monitoring the operation.
(xi) Ducting if required, bellows, mechanical hardware like locks, hinges fasteners etc to be provided.
(xii) Deliverables. 75 dBA @ 1 mtr at full load under free field conditions. The temp inside the enclosure will be within as per manufacturer’s recommendations above ambient temp.
(xiii) The enclosure should be provided with bulk head light fitting for inside illumination.
(xiv) The battery should be placed inside the enclosure beside the DG Set on a suitable insulated plat form.
(xv) The DG Set should be provided with external Emergency stop push button.
(xvi) The acoustic enclosure parts shall be of powder coated after pretreatment process. The powder coating shade should be as per manufacture's design. The base frame should be painted with epoxy based black shade.
Make for ACCOUSTIC PANEL:- DG SET OEM
The following items are deemed to be included in the rate quoted for all DG sets:-
(i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Govt.
(ii) The contractor shall arrange for artificial load (water load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer.
(iii) Testing of sound level should carried out at the site in presence of GE or a person as authorised by him.
(iv) One year Maint Spare as per manufacturer's maint schedule and as directed by Engr-in-Charge is deemed to be included in the above offer.
(v) One set of latest Spare part catelogue with price, exploded view of parts and user's manuel are deemed to be included in the offer. Note : DG Set should be testing after derating factor.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron strip 32x6 mm by means of bolts, nuts , check nuts and washers of galvanized iron and GI Strip protected by provision of GI medium grade protection pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling in alternate layers, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to DG Sets & LT Panels all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
Supply, install, connecting, testing and commissioning of cubicle compartmentalised outdoor type LT Panel of size 1.5m x 1.5m x 0.7m, factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Plateform, connect with electric supply complete all as specified and as directed by Engr -in-Charge. Location:- Main LT panel No-1
(a) Bus bar chamber having 4 copper strip Bus bar having air insulated and PVC sheathed 600 A Capacity fixed in position with required nuts bolts and porceline insulator etc.
(b) MCCB 4 Pole, 36 KA, 415 V, with adjustable Thermal and fixed Magnetic (Manual Fixed type) of capacity 400 Amps. 01 No for incoming
(c) MCCB 100 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for Outgoing (LT Panel No-2 at Offrs Resi)
(d) MCCB 125 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for Outgoing (LT Panel No-5 at Office Resi Sig Regt)
(e) MCCB 200 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for Outgoing (LT Panel No-3 at Office)
(f) MCCB 63 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for Outgoing (LT Panel No-8 at Office Area)
(g) MCB TPN 32 Amps, 4 No (01 No Standby)
(h) MCB SPN 32 Amps, 01 Nos (01 Nos Standby)
(j) ON Load Change over Switch 400 Amps 4 Pole adjustable type -01 No
(m) Phase indicator lamp LED Type
Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, install, connecting, testing and commissioning of cubicle compartmentalised outdoor type LT Panel of size 1.5m x 1.2m x 0.7m, factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Plateform, connect with electric supply complete all as specified and directed by Engr-in-Charge. (LT PANEL No-2 Offrs Mess)
(a) Bus bar chamber having 4 copper strip Bus bar having air insulated and PVC sheathed 150 A Capacity fixed in position with required nuts bolts and porceline insulator etc.
(b) MCCB 100 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for Incoming
(c) MCCB 63 Apms, 415 Volts, 16 kA, 4 Pole - 01 No for Outgoing
(e) MCB TPN 32 Amps, 7 Nos
(f) MCB SPN 32A Amps, 01 No
(j) Phase indicator lamp LED Type
Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, install, connecting, testing and commissioning of cubicle compartmentalised outdoor type LT Panel of Size 1.5m x 1.2m x 0.7m factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Plateform, connect with electric supply complete all as specified and directed by Engr-in-Charge. (LT PANEL No-3 at Office Area)
(a) Bus bar chamber having 4 copper strip Bus bar having air insulated and PVC sheathed 300A Capacity fixed in position with required nuts bolts and porceline insulator etc.
(b) MCCB 200 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for Incoming
(c) MCCB 160 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for Incoming (For LT Panel No-4 at MI Room)
(d) MCB TPN 32 Amps, 05 Nos (02 Nos Standby)
(e) MCB SPN 32 Amps, 03 Nos
(h) Phase indicator lamp LED Type
Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, install, connecting, testing and commissioning of cubicle compartmentalised outdoor type LT Panel of size 1.5m x 1.2m x 0.7m, factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Plateform, connect with electric supply complete all as specified and directed by Engr -in-Charge. (LT PANEL No- 4 at MI Room)
(a) Bus bar chamber having 4 copper strip Bus bar having air insulated and PVC sheathed 250A Capacity fixed in position with required nuts bolts and porceline insulator etc.
(b) MCCB 160 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for Incoming
(c) MCCB 100 Apms, 415 Volts, 16 kA, 4 Pole - 01 No for Outgoing
(d) MCB TPN 32 Amps, 6 Nos
(e) MCB SPN 32 Amps, 02 Nos (01 Nos Standby)
(h) Phase indicator lamp LED Type
Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, install, connecting, testing and commissioning of cubicle compartmentalised outdoor type LT Panel of size 1.5m x 1.2m x 0.7m, factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Plateform, connect with electric supply complete all as specified and as directed by Engr-in-Charge. (LT PANEL No-5 Offrs Resi SR)
(a) Bus bar chamber having 4 copper strip Bus bar having air insulated and PVC sheathed 200A Capacity fixed in position with required nuts bolts and porceline insulator etc.
(b) MCCB 125 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for Incoming
(c) MCCB 100 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for Outgoing (For LT Panel No-6 at OR Living)
(d) MCB TPN 32 Amps, 05 Nos (01 No Standby)
(e) MCB SPN 32 Amps, 03 Nos (01 Nos Standby)
(h) Phase indicator lamp LED Type
Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, install, connecting, testing and commissioning of cubicle compartmentalised outdoor type LT Panel of size 1.5m x 1.2m x 0.7m, factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Plateform, connect with electric supply complete all as specified and directed by Engr-in-Charge. (LT PANEL No-6 at OR living)
(a) Bus bar chamber having 4 copper strip Bus bar having air insulated and PVC sheathed 150A Capacity fixed in position with required nuts bolts and porceline insulator etc.
(b) MCCB 100 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for incoming
(c) MCCB 63 Apms, 415 Volts, 25 kA, 4 Pole - 01 No for Outgoing
(d) MCB TPN 32 Amps, 2 Nos
(e) MCB SPN 32 Amps, 5 Nos (Nos 1 Standby)
(h) Phase indicator lamp LED Type
Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, install, connecting, testing and commissioning of cubicle compartmentalised outdoor type LT Panel of size 1.5m x 1.2m x 0.7m, factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Plateform, connect with electric supply complete all as specified and directed by Engr-in-Charge. (LT PANEL No-7at QM Office)
(a) Bus bar chamber having 4 copper strip Bus bar having air insulated and PVC sheathed 100A Capacity fixed in position with required nuts bolts and porceline insulator etc.
(b) MCCB 63 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for Incoming
(e) MCB TPN 32 Amps, 02 Nos
(g) MCB SPN 32 Amps, 08 Nos
(j) Phase indicator lamp LED Type
Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, install, connecting, testing and commissioning of cubicle compartmentalised outdoor type LT Panel of size 1.5m x 1.2m x 0.7m, factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Plateform, connect with electric supply complete all as specified and directed by Engr-in-Charge. (LT PANEL No-8 at Office)
(a) Bus bar chamber having 4 copper strip Bus bar having air insulated and PVC sheathed 100A Capacity fixed in position with required nuts bolts and porceline insulator etc.
(b) MCCB 63 Apms, 415 Volts, 36 kA, 4 Pole - 01 No for incoming
(c) MCB TPN 32 Amps, 2 Nos
(d) MCB SPN 6-32A Amps, 01 Nos
(g) Phase indicator lamp LED Type
Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
M/S MALIK CHAND SIRI RAM
national engineering
G N Constructions
ALCO ENGINEERSPVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .