Loading…
Loading…
Tender ID
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
16 Apr 2026, 1:00 pmClosed
Institute Engineer
Office of Institute Engineer, IWD, IIT Roorkee
Electrical General Maintenance/ Renovation Works in Saharanpur Campus at IIT Roorkee
2026_IITR_903818_1
IWD/IE/2025-26/Tender/E-321
Open Tender
Electrical Works
Percentage
365 days
Saharanpur Campus, IIT Roorkee
As per tender document
7 documents required · 7 mandatory
₹1,180
Registrar
₹1.7 L
28 Apr 2026
26 Mar 2026
17 Apr 2026
26 Mar 2026
16 Apr 2026
9 Apr 2026
26 Mar 2026 - 2 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying and Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge, with piano type switch, phenolic laminated sheet, suitable size M.S. Box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc as required. Group-A | |||||
| 2..do..but 2 way light point with 2 nos. two way P.T. switch. | |||||
| 3Supplying and Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit ISI 16 gauge with modular type switch, modular plate,suitable GI box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc as required.Group-A | |||||
| 4.....do.....but 2 way light point with 2 nos. two way modular switches. | |||||
| 5Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch , phenolic laminated sheet, suitable size M.S. Box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc as required.Group-A | |||||
| 6Wiring for twin control light point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 mm². FRLS PVC insulated copper conductor single core cable etc. as required. | |||||
| 7Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc. as required.Group-A | |||||
| 8Wiring for twin control light point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable etc. as required. | |||||
| 9Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 mm² FRLS PVC insulated copper conductor single core cable make and earthing the point with 1.5 mm² FRLS PVC insulated copper conductor single core cable in existing surface/ recessed steel/ PVC conduit including dismantling as required. | |||||
| 10Rewiring for twin control light point with 1.5 mm² FRLS PVC insulated copper conductor single core cable and 1.5 mm² FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. | |||||
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 1.34 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
BOQ_950003.xls
BOQ • 0.43 MB
E321.pdf
Tender Documents • 1.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .