Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC | L1 | Accepted-AOC Successful L1 bidder. | |
| 2 | L2₹49.0 L+₹2.1 L (4.45%)Rejected-Finance AT SIHODIH PO SIRSIYA DIST GIRIDIH JHARKHAND 815301 | GIRIDIH | GIRIDIH | JHARKHAND | 815301 | L2 | Rejected-Finance As not L1 bidder | |
| 3 | Rejected-Technical 155 230 232 JANGAL PUR ROAD JANGAL PUR ROAD AIRPORT AREA KOLKATA WEST BENGAL 700081 | 24 PARAGANAS NORTH | WEST BENGAL | 700081 | - | Rejected-Technical Not qualified |
Tender Value
₹50.5 L
EMD Value
₹63,200
Closing Date
27 Nov 2023, 11:00 amClosed
A.E.(EandM) Salanpur Area
Office of the GM Salanpur Area, Lalganj, Asansol
Construction of 100MT Road Weighbridge (1No.) at Gourangdi Colliery under Salanpur Area along with 4 years of CAMC after 1 years of guarantee/Warranty Period.
2023_ECL_293501_1
SLN/GM/EandM/E Tender/23-24/326 Dt.10/11/2023
Open Tender
Miscellaneous Works
Item Rate
90 days
Salanpur Area
Please refer Tender documents.
12 documents required · 12 mandatory
₹63,200
2 Mar 2024
11 Nov 2023
28 Nov 2023
11 Nov 2023
27 Nov 2023
11 Nov 2023
11 Nov 2023 - 20 Nov 2023
Amount
Supply and Fabrication of 16 Mtr x 4 Mtr platform as per the design & specification (Annexure A)
ISMB (600 X 210 X 12) Size in MM - Total length about 34 MTR
ISMB (450 X 150 X 9.4) Size in MM- Total length about 34 MTR
ISMB (300 X 140 X 7.7) Size in MM- Total length about 60 MTR
12 mm MS Plate- approx 66 SQ. MTR
20 mm MS Plate- approx 1.0 SQ. MTR
M20 x 50 HT Bolt & Nut
Top Bolt with Nut Machine 19 X 300
Fabrication Cost
Electronic Weighing System as per specfication (Annexure B)
30 Te capacity load cell as per specification
7 segment Digital weighing indicator
Jumbo Display Unit
Junction Box
Computer/PC with accessories as per specification
Furniture & Fixtures for weighing room as per specification
1.5 Te Air conditioner machine with suitable voltage stabiliser (5 KVA)
3KVA Constant Voltage Stabiliser / CVT
RFID/ Weighbridge Automation System (Annexure C)
RFID tag
Long Range RFID Reader/Writer with pole and mounting
Signal Light For traffic control
5 Mtr Long Boom Barrier complete with Trigger Switch, operating & Safety Sensor (with IP54 protection)
3 KVA UPS with 12 nos. Battery (65Ah) and 4 hrs full load backup
Battery stand
Network Switch unmanaged (16/18port)
9U Rack
Laser/Inktank Printer
Application software as per Specification
Surge Protection devices (SPDs)
Chemical Earthing Kit of Suitable length
HDPE Pipe
CCTV Survillance System (Annexure D)
2 MP IP Network Bullet camera with Fixed Lens with all mounting accessories
2 MP IP Network Dome camera, with all mounting accessories.
8 Channel Network Video Recorder (NVR)
4 TB SATA Surveillance Grade Hard Disk Drive, 7200 RPM (for NVRs)
Adaptor (DC power supply)
Min. 21 Inch Monitor (For monitoring)
8 Port unmanaged gigabit network switch
Lightning, Surge Protection and Earthing System (Annexure E)
Type 1: 'B' TYPE PROTECTION (Power line protection at distribution level) :- As per IEC 61643-11:2011
Type 3: 'D' TYPE PROTECTION for Load Cell and Digitizer :- As per IEC 61643-11:2011
Maintenance free Chemical earthing (earth electrode, backfill compound, wire) for grounding all surge protection devices)
Weighbridge Cabin, ramp and other civil works
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth. sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
P/L in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
P/L in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fllets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended foors, roofs having slope up to 15* landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to foor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 Coarse sand)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
P/L Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
P/F on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
P/F on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
P/F unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete. 110 mm
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Neat cement punning.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. One coat
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required: 40 A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.- 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required: Group A
P/F 70Watts ceiling fan, 320 or more RPM, 1200mm sweep size, copper motor, aerodynamics ABS Blades of metallic finish make of orient, havells or equivalent.
Installation, training, commissioning & complete integration of all the items along with other miscellaneous items (item sl. No. 1 to sl. No.6.31)
Comprehensive annual maintenance contract as per Annexure-F
Total impact of GST for the purpose of CTC
BAIDYA NATH WEIGHING MACHINE CO.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .