Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹28.6 L
EMD Value
₹57,139
Closing Date
12 Oct 2026, 3:30 pm3d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EE,ELD-4,DDA
EE,ELD-4,DDA
RMO of Firefighting i/c sprinkler, Fire Alarm and P.A. System, its DG Sets and Ventilation System including providing of Fire Fighting Operator at pocket 3, sector A1 to A4, Narela.
2026_DDA_927976_1
48/EE/ELD-4/DDA/2026-27
Open Tender
Electrical Works
Works
365 days
NARELA
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹57,139
01/10/2026 at 12.00 P.M. in the chamber of EE/ ELD
12 Oct 2026
28 Sept 2026
13 Oct 2026
28 Sept 2026
12 Oct 2026
1 Oct 2026
1 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Running, maintenance, operation of Fire fighting i/c sprinkler ,Fire Alarm & P.A. System, DG Sets and Ventilation System and other accessories including providing of Fire Fighting Operator as per inventory and terms and conditions attached. | 12 | P/Month | 2,15,231 | ₹25,82,772 |
| 2 | Supplying and replacement of heavy duty rechargeable battery of 180 AH, 12 Volt suitable for DG set/UPS/fire alarm or other approved application, complete with all necessary connections, terminals, accessories, transportation, installation, testing and commissioning as required. The battery shall be of approved make and conform to relevant IS specifications, with warranty period of 42 months comprising 24 months free replacement warranty and further 18 months warranty on pro-rata basis, etc. complete as required | 1 | Job | 19,745 | ₹19,745 |
| 3 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain etc. as required.
Single headed Stainless steel. (DSR 27.9.2) | 5 | Nos. | 6,632 | ₹33,160 |
| 4 | Providing and fixing M.S. dead plate/blank flange cover for missing landing valve outlet of internal fire fighting system, fabricated from minimum 6 mm thick mild steel plate of suitable size conforming to landing valve outlet dimensions, including rubber insertion gasket, nuts, bolts, washers and necessary drilling/threading complete, duly painted with one coat of red oxide primer and two coats of synthetic enamel paint of approved fire red shade, properly fixed to prevent leakage and maintain integrity of the fire fighting line etc. complete as required. | 35 | Job | 1,081 | ₹37,835 |
| 5 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with
all connections etc. as required.(DSR 28.1.2) | 10 | Nos. | 1,223 | ₹12,230 |
| 6 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed
temperature (dual thermistor) type with mounting base complete with all connection etc. as required. (DSR 28.1.1) | 10 | Nos. | 1,136 | ₹11,360 |
| 7 | Refilling, servicing, testing and refixing of 4.5 Kg CO₂ Type Fire Extinguisher, conforming to relevant BIS specifications and IS 2190, including dismantling, internal and external cleaning, replacement of defective washers, seals, safety pins, discharge horn/hose and other minor components as required, hydraulic pressure testing wherever due, refilling with approved extinguishing media, weighing, leak testing, fixing of service tag/sticker, repainting/touch-up wherever required, refixing the extinguisher at its designated location etc. complete as required. | 25 | Nos. | 1,904 | ₹47,600 |
| 8 | Providing High Speed Diesel (HSD) for run of Diesel driven water curtain pump and Diesel driven pump as per inventory, to keep all the Diesel driven pump functional in all respect during the contract period. | 250 | Lts | 98 | ₹24,500 |
| 9 | Refilling, servicing, testing and refixing of 6 Kg ABC Dry Powder Type Fire Extinguisher, conforming to relevant BIS specifications and IS 2190, including dismantling, internal and external cleaning, replacement of defective washers, seals, safety pins, discharge hose/nozzle and other minor components as required, hydraulic pressure testing wherever due, refilling with fresh ABC dry chemical powder, pressurization, weighing, leak testing, fixing of service tag/sticker, repainting/touch-up wherever required, refixing the extinguisher at its designated location etc. complete as required. | 25 | Nos. | 1,630 | ₹40,750 |
| 10 | Checking, servicing, cleaning, refixing, testing and commissioning of existing flow switch i/c repairs of internal defective parts, checking and removing leakages so as to make it in proper functional condition complete as required. | 10 | Nos. | 2,850 | ₹28,500 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.73 MB
BOQ_975190.xls
BOQ • 0.29 MB
NIT48.pdf
Tender Documents • 1.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .