Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 CrAccepted-AOC NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹24.4 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹26.2 CrRejected-Finance | ₹26.2 Cr | L2 | Rejected-Finance Rejected being higher than L1 bidder. |
| 3 | L3₹27.2 CrRejected-Finance | ₹27.2 Cr | L3 | Rejected-Finance Rejected being higher than L1 bidder. |
| 4 | L4₹28.6 CrRejected-Finance BHAGWATI BHAWAN PO HASIMARA DIST JALPAIGURI PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹28.6 Cr | L4 | Rejected-Finance Rejected being higher than L1 bidder. |
| 5 | L5₹29.5 CrRejected-Finance | ₹29.5 Cr | L5 | Rejected-Finance Rejected being higher than L1 bidder. |
Tender Value
₹24 Cr
EMD Value
₹15 L
Closing Date
28 Aug 2020, 6:00 pmClosed
CE (AF) SHILLONG ZONE
HQ CE (AF) SHILLONG ZONE, ELEPHANT FALLS CAMP, PO-NONGLYER, SHILLONG-793009
PROVN OF CERTAIN TECHNICAL STORAGE ACCNS INCLUDING SERVICES AT AF STN CHABUA
2020_MES_357544_1
88545/CHAB/E8
Open Tender
Civil Works
730 days
GE AF CHABUA
As per tender Documents
8 documents required · 8 mandatory
₹3,000
GE AF CHABUA
₹15 L
Yes
CE (AF) SHILLONG ZONE
23 Sept 2020
2 Jul 2020
3 Sept 2020
2 Jul 2020
28 Aug 2020
14 Aug 2020
2 Jul 2020 - 29 Jul 2020
20 Jul 2020
Amount
SCHEDULE "A" Part - I (BUILDING WORKS) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-II (EARTH WORK AND SITE CLEARENCE ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (FIRE POINT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SIGN BOARD) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (RCC STATIC WATER TANK) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-IX (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-X (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XI (DEMOLITION/DISMANTLING) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XII (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART -XIII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
EARTH WORK & SITE CLEARANCE. M&L Bringing approved earth from outside MD land and forming embankment including raising earth, spreading in layers n.exc. 30 cm thick, watering, ramming/rolling and finished to required gradient, size and shape etc not exceeding 1.50 metre from the base complete all as specified and as directed. Note:- (i) Payment shall be made for solid quantity arrived after consolidation. (ii) Before execution of this item earth shall be tested/checked for suitablity to use.
INTERNAL ELECTRIFICATION. S&F Flame proof switch fuse unit with HRC fuse 16 Amps double pole all as specified and directed.
S&F MCB SPN 6 to 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and directed.
S&F MCB SP 6 to 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and directed.
S&F LED T-8 Retrofit tube light fitting 4 ft , flame proof type FLP-WP of 2X20 watt including integral reflector made of aluminium alloy LM6 with heat resistant tubular glass cover held in two aluminium cups , with bipin holders, connector block , etc and all accessories pre wired and including 2 Nos 20 watt LED tube of suitable size , connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed .
S&F LED Retrofit Wellglass light fitting, flame proof type FLP-WP of 1X20 watt made of aluminium alloy LM6 with heat resistant and toughened glass cover,, painted MS wire guard and eye bolt including 01 No 20 watt LED lamp with connector block, etc and all accessories complete all as specified and as directed.
S&F LED T-8 Retrofit tube light fitting 4 ft 1x20 watt, 230 volt energy efficient epoxy powder coated CRCA sheet housing with channel, connector block, etc. including 1x20 W LED Tube light complete with all accessories internally pre-wired and including connection with twin core twisted flexible wire copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed. Make :- C&S Electric Cat No LT4F20WLEDT8/WD(Tube Light) and LTDC30120WLED(Fitting Batten) or equivalent from make list specified in PS.
S&F ceiling fan 1400 mm sweep 240 volt AC white colour and including connected with twin core twisted flexible wire copper conductor cable of suitable size complete all as specified and directed. Make Havells model No. SS 390 or equivalent from make list as specified in PS.
S&F Exhaust fan 300 mm sweep 240 volt AC and including connected with twin core twisted flexible wire copper conductor cable of suitable size complete all as specified and directed. Make Havells model No. Ventil Air-DB or equivalent from make list as specified in PS.
M&L for Earthing complete with galvanised steel earth plate electrode of size 600x600x6.3 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4.0 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron all as shown in electric plate No 3 all as specified and indicated complete with funnel, charcole, dust, salt etc and GI protection pipe, light grade 20 mm bore and GI watering pipe 20 mm bore medium grade, Concrete earth pit in PCC(1:3:6) type C-1, 40mm thick pre cast RCC 1:2:4 type B-0 cover slab reinforced with 6mm dia mild steel round bar @ 10cm centre to centre both way and suitable handle of 10mm dia round bar, including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc 50m and necessary testing complete all as specified and as directed. (For Internal Electrification - 11 Nos and for External Electric Supply - 9 Nos and for Lightening Protection - 2 Nos and for DG Set - 4 Nos)
EOT CRANE. Design, supply and installation of flame proof EOT crane, double gudder type having span of 9.5 m, long travel 36 m, clear hook height 3.0 m and weight lifting capacity of 5.0 Ton considering following conditions complete all as specified and directed:- (i) Internal dimension of Bldg is 36m X 19.4m X 5.2m with partition wall at middle. (ii) Clear hook height available from FFL is 3.0m (iii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 3-4m/min (b) Micro in main Hoist - 0.4 m/min. (c) Cross travel - 5 m/min (d) Micro in cross travel - 0.5 m/min (e) Long travel - 10-15 m/min (f) Micro in long travel- 1m/min (iv) EOT crane fitted should be fire/flame proof and comply with the safety specification given in the STEC pamphlet No 7. (v) Design of crane and proof checking of design from Govt Chatered Engineers within 2months from the date of accept of tender.
Design, supply and installation of flame proof EOT crane, double girder type having span of 7 m, long travel 19 m, clear hook height 4.2m and weight lifting capacity of 5.0 Ton considering following conditions complete all as specified and directed:- (i) Clear hook height available from road level is 4.2m. (ii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 3-4m/min (b) Micro in main Hoist - 0.4 m/min. (c) Cross travel - 5 m/min (d) Micro in cross travel - 0.5 m/min (e) Long travel - 10-15 m/min (f) Micro in long travel- 1m/min (iii) EOT crane fitted should be fire/flame proof and comply with the safety specification given in the STEC pamphlet No 7. (iv) Design of crane and proof checking of design from Govt Chatered Engineers within 2 months from the date of accept of tender. Note for Item No. 13.11 & 13.12:- Crane should be provision of load cell with digital display of load for monitoring the lifting load including cut off facility after exceeding the rated load.
EXTERNAL WATER SUPPLY. M&L Construction of brick massonry valve pit chamber of inner dimension 90x90x90 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including MS sheet cover of thickness 2 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and necessary excavation in soft/loose soil, returning, filling in and removal of surplus soil to a distance not exc 50 m complete all as specified and directed.
M&L Construction of brick massonry valve pit chamber of inner dimension 60x60x60 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including MS sheet cover of thickness 2 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and necessary excavation in soft/loose soil, returning, filling in and removal of surplus soil to a distance not exc 50 m complete all as specified and directed.
Supply and laying burnt bricks, sub class 'B' in cable trenches as cable protection complete all as specified and directed
Supply, install, testing and commissioning of indoor type Metal clad Vacuum Circuit Breakers panel of capacity 11 KV, 400Amp, 3 Phase, 3 wire, 50Hz, having a fault level of 250 MVA at 11 KV, 13.1 KA breaking capacity totally enclosed single bus bar for each phase, floor mounting, metal clad, Indoor extensible type flush fronted, Draw out type, horizontal / vertical isolation type with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assembly of 3 vacuum interrpupters with epoxy support insulations and self – aligning finger type isolating contracts, truck having integral racking with necessary interlocks ( for insertion and withdrawal of VCB), manual and automatic motor charged independent closing / tripping spring, trip free operating mechanism with closing and tripping push buttons and mechanical breaker, including in-build battery backup system & all standard fitting and accessories of following specification for incoming out going and Bus coupler complete all as specified and as directed including the followings:-
Serial Item No. 13.16 (Contd...) Specification of VCB (i) Bus bar chamber with 3 phase copper bus bar 630 Amp rating duly insulated - 01 set (set of three) (ii) Electrical shunt trip coil 24V DC - 01 No (iii) Electrical closing coil 24V DC - 01 No (iv) CT Chamber incorporating 3 Nos single phase resin cast current transformer ratio 100/50/5-5 class 1.0 for metering & class 5P10 for protection and Burdon 15 VA - 1 Set (v) 3 phase, 3 Limb draw out type bus connected Epoxy potential transformer ratio 11KV/ √3/ 110V/ √3AC accuracy 1.0, Burdon 200 VA-01 No (vi) Digital ammeter 0 to 100 Amp, (100% of CT ratio) for 3 phase-01 No (vii) Digital voltmeter rating 0 to 12 KV for 3 phase – 01 No (viii) Digital load manager for amps, volts, KW, KVA, KVAR and PF -01 No (ix) Three phase over current and earth fault digital numerical relay (over current (INST 50) & IDMT-51 – 3 pole & earth fault (INS (50N) & (INS (50N) & IDNT 51N - single pole) & negative sequence 46 auxiliary supply 20 -100V AC /DC CT output contacts 2 no + NC, rating-5, O/C Is= 20-200% in step of 5%E/F Os=5-80% in step of 5%. The features and specification conforming to IEC 60870 -5-103 & Model No. MI COM P 122 of AREVA or equivalent as per List of make. (x) Auxiliary relay with 6 N/C – 1 No (xi) TNC switch and LR switch – 1 No (xii) Heat control switch with space heater to be operated through Auxiliary DC supply – 1 No (xiii) RYB, ON/OFF spring charged and discharged & VCB trip inductions – 1 Set (xiv) Space heater with thermostat - 1 No (xv) Operating counter – 1 No (xvi) Rear cable box suitable for 95 Sqmm 3 core XLPE cable (xvii) Spring charging motor with starter 24 VDC – 1 No (xviii) Power pack unit for each VCB of suitable capacity and backup for 24 VDC auxiliary including constant float charging unit (xix) VCB to be fitted in existing VCB Bank of Make Scheinder at MRS as outgoing VCB by suitable addition/ alternation. (xx) VCB to be fitted at IGLOO Sub Stn as standalone VCB to act as incoming and outgoing VCB. (1 at MRS & 1 at IGLOO location)
Supply, installation, testing and commissioning of distribution transformer, capacity 315 KVA step down, indoor/ outdoor type floor mounting, double copper wound core type 3 Phase 50 Hz AC, oil immersed with 'ONAN' type cooling with external cooling tubes / radiators having no load voltage ratio 11000/433V (corresponding to principal tapping) delta connected on primary side (HV incoming) and star connected on secondary side (secondary out going) in accordance with vector group symbol (Dyn-11) conforming to IS 1180 of 2014 Part 1 (energy efficiency level-2) and having off load tap changer in the steps of 2.5% on HV side to take care of voltage from (+)5% to (-) 10% to give output on 433V secondary side and including initial oil filling to appropriate level, control cable, and following standard fittings complete all as specified and as directed including the followings:- (a) Oil conservator with oil fitting hole cap and drain plug. (b) 01 No of prismatic oil level gauge mounted on conservator wall with first fill of charge up to maximum level. (c) Silica gel dehydrating breather with oil seal and first fill of charge. (d) Pressure release valve with automatic resetting arrangement after release of pressure. (e) Adequate No of thermometer pocket including one thermometer. (f) Top oil filter valve. (g) Bottom oil filter cum drain valve. (h) Rating diagram and terminal marking plate. (j) Earthing terminal - 02 Nos (k) Lifting Lugs - 01 Set (l) Jacking Pads - 01 Set (m) Under carriage with 4 Nos of plain rollers. (n) Air release plug on main transformer tank.
M/L for Earthing complete with galvanized steel earth plate electrode 60 x60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to GI earth lead 32 x 6 mm dia by means of bolts nuts, check nut and washers of GI and GI tubing 40 mm bore, light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C 1, pre cast RCC (1:2:4) type B1 cover slab 450 x 450 x 50 mm with one handle for lifting made out of 8 mm dia MS bar, wire mash, 20 mm bore GI tubing medium grade for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed Electrical plate no 3 of SSR Part-I. (For External Electric Supply - 14 Nos and for DG Supply - 04 Nos)
Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to 20x3 mm copper strips as earthing lead of nut, bolts and washers made out of brass/GM and 32 mm dia GI pipe "light grade" for protection of earth lead and connected to transformer / panel / switch board or main switch or as directed by Engr -in-Charge including earthing pit in PCC (1:3:6) type C1, pre-cast cover RCC cover slab with one handle made out of 8 mm dia round bar 20 mm dia GI pipe medium grade for watering funnels, wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete all as shown in electrical plated No 3 and testing complete.
Supply and installed testing and commissioning indoor type APFC bank panel , MDXL offered Heavy duty Mixed Dy Electric type Box capacitor with 7% Aluminum wound Reactor, units tested in accordance with IS 13340-1993/IS 13341-1992, IEC 60831 part 1&2 with thyrister control module with aluminium heat sink with semi-conductor fuses, smooth switching On and Off automatically at + 10 volts, compartmental design dust and vermin proof suitable for 3 phase, 4 wire 440 volt, made out of 2mm thick CRCA sheet with built upon rigid frame work, cubical type type, heavy duty powder coated RAL 7035, capacity 100 kVAr (50X1+20X1+10X3) kVAr capacitor bank having following accessories including control wiring with HR FR / FRLS copper wire complete all as specified and directed as follows :- (i) To withstand on Non Linier load upto 40% (ii) 2.5 In Over Current with stand (iii) 10000/year Switching capacity (iv) 1,60,000 hours life expectancy (v) Capacitor, MCB/MCCB, Contactors, APFC Relay will be of same make (vi) Panel fabrication need to be in house and at component manufacturers own factory. (vii) Pre dispatch/ Factory inspection is mandatory (viii) APFC design with Aluminium bas bar as per global standard current density of 0.8A/ Sq mm, (1A/Sq mm in case of copper) (ix) Ambient will be of 45 deg C (x) Ventilation air within cubicle must flow upwards (xi) Extractor fan must be fitted in top of cubicle (xii) Bottom air inlet should be as low as possible
Serial Item No. 13.22 (Contd...) (xiii) Cross section of top air outlet must be more than bottom outlet (xiv) Reactor must be fitted in separate enclosoure of capacitor (xv) APFC relay with RS485 communication, Duel setting for EB & DG load, to monitor KVAR de rating, inbuilt programmable alarm for capacitor dating, Harmonic Monitoring 3rd to 19th, Temperature alarm and with Fan control relay. (xvi) Compact modular bolted design, removable side and back panels with bottom cable entry. (xvii) Capacitor installed in removable assemblies for ease of operation and maintenance. (xviii) Incoming of APFC panel of MCCB 3P 200 Amps, 36 kA breaking capacity CVS TMD type with O/L & S/C protection. (xix) High performance microprocessor based 3 phase APFC relay VarplusLogic 06 stage with Auto/Manual switch Option. (xx) 3 phase power analyzer with in-buit , Digital VAF meter, Phase indicating Lamps(R,Y,B), Step indicating lamps, ON/OFF Push buttons, Timer, CT-200/5A, CI-1.0, 10VA. (xxi) Induced air system provided with axial flow fan/ centrifugal fan. (xxii) MDXL capacitors of 100 kVAr (50X1+20X1+10X3) For 10 kVAr – 3 STEPS (a) MCCB, 3P, 36KA CVS TMD type-25A, (b) TVS E type, TP, Power Contactor – 18A (c) 7% detuned reactor, 440V, Al wound type – 10kVAr For 20 kVAr – 1 STEPS (a) MCCB, 3P, 36KA CVS TMD type-50A, (b) TVS E type, TP, Power Contactor – 50A (c) 7% detuned reactor, 440V, Al wound type – 20kVAr For 50 kVAr – 3 STEPS (a) MCCB, 3P, 36KA CVS TMD type-100A, (b) TVS E type, TP, Power Contactor – 95A (c) 7% detuned reactor, 440V, Al wound type – 50kVAr Note:- The APFC panel and capacitor Bank should be the same manufacturer as per PS.
Labour only for horizontal boring with trenchless technology for passing protection pipe upto 80mm bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a single length, complete all as specified and directed. Note : Pipe to be measured separately.
Supply, installation, commissioning and testing of main LT panel of size suitable to accomdate mentioned accessories , factory made (CPRI approved) indoor cubical compartmental type double door both side openable with hinged doors & locking arrangement made out of not less than 3 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x50 x6mm angle iron frame including earthing stud lebeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 stage process), duly fixed in ground with PCC foundation (1:2:4) type B1 with danger notice plate of 1.6mm thick mild steel sheet, vitrious enamelled (white) with letters figures and conventional skull and bones in signal red colour suitable for 3 phase 4 wire system 500Volts grade with necessary wiring with PVC sheathed strander al conductor of appropriate length size with and including fixing lugs bolts, screws etc complete all as specified and directed. For safety , panel shall be finger touch proof and it should have IP-20 Protection in module door open condition. Busbars shall be made of high conductivity, and high strength Aluminum E91 grade as per IS 5082-1981, of rectangular cross sections better suitable for full load current for phase bus bars and half/ full rated current for neutral bus bar or as per requirement . The busbars shall be supported on non-breakable, non-hygroscopic epoxy resin or glass fiber reinforced polymer insulated supports.The material and the spacing of the Busbar supports should be same as per the type tested assembly (TTA). All bus bars shall be provided in a separate chamber and all connections shall be done by bolting. Panel comprising of the following accessories :-Incoming:- (a) Aluminium busbar of rated capacity 600 Amps cover with PVC insulated sleeves including insulator, nuts, bolts etc incl connection complete - 01 set (b) MCCB with thermal magnetic release of capacity 500 Amps 415V. 4 pole 50Hz, Ics = 100% Icu, breaking capacity 50 KA -01 No. (c) Neon indicator lamp with holder (Yellow, Blue,Red)- 01 set (Set of three) (d) Digital VAF meter with suitable CTs - 01 No. Outgoing:- (a) MCCB with thermal magnetic release of capacity 400 Amps 415V. 4 pole, 50Hz, Ics = 100% Icu, breaking capacity 50 KA -01 Nos. (b) MCCB with thermal magnetic release of capacity 250 Amps 415V. 4 pole, 50Hz, Ics = 100% Icu, breaking capacity 35 KA -01 Nos
Supply, installation, commissioning and testing of DB-2 & DB-3 LT panel of size suitable to accomdate mentioned accessories , factory made (CPRI approved) indoor cubical compartmental type double door both side openable with hinged doors & locking arrangement made out of not less than 3 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x50 x6mm angle iron frame including earthing stud lebeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 stage process), duly fixed in ground with PCC foundation (1:2:4) type B1 with danger notice plate of 1.6mm thick mild steel sheet, vitrious enamelled (white) with letters figures and conventional skull and bones in signal red colour suitable for 3 phase 4 wire system 500Volts grade with necessary wiring with PVC sheathed strander al conductor of appropriate length size with and including fixing lugs bolts, screws etc complete all as specified and directed. For safety , panel shall be finger touch proof and it should have IP-20 Protection in module door open condition. Busbars shall be made of high conductivity, and high strength Aluminum E91 grade as per IS 5082-1981, of rectangular cross sections better suitable for full load current for phase bus bars and half/ full rated current for neutral bus bar or as per requirement . The busbars shall be supported on non-breakable, non-hygroscopic epoxy resin or glass fiber reinforced polymer insulated supports.The material and the spacing of the Busbar supports should be same as per the type tested assembly (TTA). All bus bars shall be provided in a separate chamber and all connections shall be done by bolting. Panel comprising of the following accessories :- Incoming (a) Aluminium busbar of rated capacity 100 Amps cover with PVC insulated sleeves including insulator, nuts, bolts etc incl connection complete - 01 set (b) MCCB with thermal magnetic release of capacity 40 Amps 415V. 4 pole 50Hz, Ics = 100% Icu, breaking capacity 25 KA -01 No. (c) Neon indicator lamp with holder (Yellow, Blue,Red)- 01 set (Set of three) (d) Digital VAF meter with suitable CTs - 01 No. Outgoing (a) MCCB with thermal magnetic release of capacity 16 Amps 415V. 4 pole, 50Hz, Ics = 100% Icu, breaking capacity 16 KA -04 Nos (b) Supply and fixing MCB SPN 20 A-02 No(1 spare)
Supply, installation, commissioning and testing of Sub LT panel of size suitable to accomdate mentioned accessories , factory made (CPRI approved) indoor cubical compartmental type double door both side openable with hinged doors & locking arrangement made out of not less than 3 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x50 x6mm angle iron frame including earthing stud lebeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 stage process), duly fixed in ground with PCC foundation (1:2:4) type B1 with danger notice plate of 1.6mm thick mild steel sheet, vitrious enamelled (white) with letters figures and conventional skull and bones in signal red colour suitable for 3 phase 4 wire system 500Volts grade with necessary wiring with PVC sheathed strander al conductor of appropriate length size with and including fixing lugs bolts, screws etc complete all as specified and directed. For safety , panel shall be finger touch proof and it should have IP-20 Protection in module door open condition. Busbars shall be made of high conductivity, and high strength Aluminum E91 grade as per IS 5082-1981, of rectangular cross sections better suitable for full load current for phase bus bars and half/ full rated current for neutral bus bar or as per requirement . The busbars shall be supported on non-breakable, non-hygroscopic epoxy resin or glass fiber reinforced polymer insulated supports.The material and the spacing of the Busbar supports should be same as per the type tested assembly (TTA). All bus bars shall be provided in a separate chamber and all connections shall be done by bolting. Panel comprising of the following accessories :- Incoming
Serial Item No.13.27 (Contd...) (a) Aluminium busbar of rated capacity 500 Amps cover with PVC insulated sleeves including insulator, nuts, bolts etc incl connection complete - 01 set (b) MCCB with thermal magnetic release of capacity 500 Amps 415V. 4 pole 50Hz, Ics = 100% Icu, breaking capacity 50 KA -01 No. (c) Neon indicator lamp with holder (Yellow, Blue,Red)- 01 set (Set of three) (d) Digital VAF meter with suitable CTs - 01 No. Outgoing (a) MCCB with thermal magnetic release of capacity 400 Amps 415V. 4 pole, 50Hz, Ics = 100% Icu, breaking capacity 50 KA -01 Nos. (b) MCCB with thermal magnetic release of capacity 40 Amps 415V. 4 pole, 50Hz, Ics = 100% Icu, breaking capacity 16 KA -02 Nos (c) Supply and fixing MCB SPN 20 A-02 No(1 spare) (d) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure-01 No
Supply, installation, commissioning and testing of DB-1 LT panel of size suitable to accomdate mentioned accessories , factory made (CPRI approved) indoor cubical compartmental type double door both side openable with hinged doors & locking arrangement made out of not less than 3 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x50 x6mm angle iron frame including earthing stud lebeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 stage process), duly fixed in ground with PCC foundation (1:2:4) type B1 with danger notice plate of 1.6mm thick mild steel sheet, vitrious enamelled (white) with letters figures and conventional skull and bones in signal red colour suitable for 3 phase 4 wire system 500Volts grade with necessary wiring with PVC sheathed strander al conductor of appropriate length size with and including fixing lugs bolts, screws etc complete all as specified and directed. For safety , panel shall be finger touch proof and it should have IP-20 Protection in module door open condition. Busbars shall be made of high conductivity, and high strength Aluminum E91 grade as per IS 5082-1981, of rectangular cross sections better suitable for full load current for phase bus bars and half/ full rated current for neutral bus bar or as per requirement . The busbars shall be supported on non-breakable, non-hygroscopic epoxy resin or glass fiber reinforced polymer insulated supports.The material and the spacing of the Busbar supports should be same as per the type tested assembly (TTA). All bus bars shall be provided in a separate chamber and all connections shall be done by bolting. Panel comprising of the following accessories :- Incoming
Serial Item No. 13.29 (Contd...) (a) Aluminium busbar of rated capacity 500 Amps cover with PVC insulated sleeves including insulator, nuts, bolts etc incl connection complete - 01 set (b) MCCB with thermal magnetic release of capacity 400 Amps 415V. 4 pole 50Hz, Ics = 100% Icu, breaking capacity 50 KA -01 No. (c) Neon indicator lamp with holder (Yellow, Blue,Red)- 01 set (Set of three) (d) Digital VAF meter with suitable CTs - 01 No. Outgoing (a) MCCB with thermal magnetic release of capacity 320 Amps 415V. 4 pole, 50Hz, Ics = 100% Icu, breaking capacity 50 KA -01 Nos. (b) MCCB with thermal magnetic release of capacity 40 Amps 415V. 4 pole, 50Hz, Ics = 100% Icu, breaking capacity 16 KA -03 Nos (c) Supply and fixing MCB SPN 20 A-02 No(1 spare)
Supply of 30W +/- 5 % Top Maintainable LED Street Light luminaire with System luminous efficacy of >110 lm/W. LED Street Light shall be made up of Die Cast aluminium housing suitable to mounted on 40 mm OD bracket arm. Luminaire compartments should be hermitically sealed to achieve IP 66 ingress protection. Optical compartment shall be provided with tempered protective custom moulded polycarbonate diffuser, thermal, shock and impact- resistant, (IK – 08), while control gear shall be provided with die cast aluminium cover for safety. High efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen efficacy of LED > 140 lm/W with PC lencs to ensure better uniformity of light distribution. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current and at 35 Deg C Ambient temperature. The LEDs used in Street Light should be CCT of 5000 K to 6500K and CRI of Minimum 70. LED Driver shall be Isolated type (SMPS based constant current supply), with proper heat sink for heat dissipation suitable to operate in input voltage range of 140V to 270V (nominal rated voltage – 240V) with Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. The Driver output should be ensure safe operating and maintenance operation. LED driver shall have output short circuit & over voltage protection, surge voltage protection and other safety tests as per IS 15885 Part-2/sec 13 inbuilt. Make : Havells Cat No. LHEWEBP7PL6S030 or equivalent in Wipro, philips and Bajaj.
S&F Cable Junction Box 200X160X98mm in size, made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 nos) fixed on poles with flat aluminium clamps of size 25x3mm, nuts, bolts, washers etc. complete all as specified and as directed. Make : Cat No. K-9250 of HENSEL or equivalent from make list specified in PS.
Supply and laying rubber mat of size 1 mtr x 2 mtr x 3 mm all as specified and directed.
Supply only rubber hand gloves suitable for 11 KV all as specified and directed.
DG SUPPLY. Supply, installation, commissioning and testing Supply and installation of 500 KVA, Silent Diesel Engine driven generating set 415 Volts, 3 phase 4 wire, engine as per IS : 10001/10002 and alternator as per IS : 13364 complete with relay panel for automatic starting on mains failure, control panel having meters, sound proof canopy and concrete foundation complete all as specified and directed comprising of following:- A. a) Fly wheel to suit flexible coupling. b) Flexile coupling with guards. c) Dry type air cleaners with filters. d) Lubricating oil filter, fuel filter, fuel pre filter. e) Anti-vibration pads-quantity and type as recommended by manufacturer. f) Fuel injection system with injector pump, nozzles, governor(electronic) of suitable capacity. g) Electric start equipment. h) Lead acid storage maintenance free battery 12 x 2 V of suitable rating with charging alternator, ammeter, as recommended by manufacturers make: Exide along with copper battery lead and connector. i) Battery rack made out of MS angle iron 40mmX40mmX5mm and 150mm height. j) Standard safety device. k) Service fuel tank of suitable capacity as recommended by the OEM including fuel connection pipes complete with the accessories.
Serial Item No. 13.35 (Contd....) l) LCD display type control panel as per manufacturer's instructions indicating KWH, KVA, PF, Volts, Amps, Hz, RPM, Hour, Oil pressure, Oil temprature, coolent temprature, fuel level, battery charging ammeter, battery charging lamp and incator lamp (RYB), panel duly prewired and displaying protection and safetys as under:- aa) Protection:- short circuit, overload, over speed, earth fault as standard and reverse power as optional. ab) Safeties:- Auto shut down, visual & audio alarm for low lub oil pressure, high coolant temperature, low fuel level, canopy temperature & radiator water level. (B) Alternator 320KVA brushless type at 0.8 power factor, self regulated, self excited, screen protected 3 phase with neutral 415 volts 50 HZ, 1500 RPM, as per IS:13364/IS-4722 complete with automatic voltage regulator, having voltage regulation +/-1%, SPDP enclosure including making cable connections, insulation class-H and alternator control panel as supplied by manufacturer. C) Base frame sturdy, MS fabricated, channel iron base frame for mounting the engine & alternator with anti vibration pads. (D) Acoustics enclosure of suitable size to accommodate DG set 320 KVA, modular construction, fabricated out of 3 mm thick, cold annealed CRCA sheet duly epoxy painted doors to be provided with high quality EDPN gasket, duly epoxy painted. The canopy to be equipped with heavy duty fans of reputed manufacturer for air circulation and cooling the canopy. Rock wool of requisite density per Kg/m3 to be used for insulation. Enclosure to be provided with one light point controlled with one switch for internal lighting. Noise level at one meter to be 75 decibels @ one meter in line as per CPCB norms. (E) Repair tools to be supplied as under:- (i) Ring spanner set of 10- 01 set. (ii) Screw driver 6",9", 12", 14" - 01 No Each.
Serial Item No. 13.35(Contd....) (iii) Adjustable spanner 12" - 01 No. (iv) Double end spanner set of 10 - 01 No. (v) Cutting pliers insulated and nose plier 10" & 12" - 01 No. (F) Maint spares to be supplied as under:- (i) All type of filters - 02 Each. (ii) V-Belt - 01 Set NOTE:- (i) The engine of DG set suitably conditioned to suit the climatic condition , so as to give desire outputs including and testing up to 10% over load. (ii) Foundation of the DG set (PCC/RCC) will be provided by the contractor and will be made as per the manufacturer instruction. Cost of foundation is deemed to be included in the rate of this item. (iii) The items required for testing of DG set e.g. fuel, tripod, tools, water tank etc and panel as below shall be provided by the contractor and the rate of which is deemed to be included in the rate of item. (iv) Testing of DG set will be carried out as specified.
LIGHTENING PROTECTION S&F H beam pole 150mmx150mm, 16 Mtr height ( weight 37 Kg per RM) complete. Note :- PCC foundation shall be measured and paid separately.
Supply and install steel tubular swaged poles 16 metres long complete with M.S. (600 x 600 x 6 mm ) base plate, finial taper plug, bolts, nuts and screws complete all as specified and as directed. Note :- Excavation, PCC fdn and coping shall be measured and paid separately.
INTERNAL WATER SUPPLY S&F 15 mm bore angle cock brass CP high pressure with capstan head long shank screwed down complete all as specified and directed.
S&F CP bib tap 15 mm bore of pipe cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe and fixed fancy type complete all as specified and directed.
SEWAGE DISPOSAL. S&F 150mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
M&L LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc complete for 10 users. Septic tank shall be installed as per manufacturer's instructions.
Construction brick masonry Soakage Well for 10 users all as specified and as shown on drawings.
Internal Electrification Supply and fixing Distribution board flame proof 3 phase, TPN 4 ways including MCCB TPN 63 Amps 16 KA as incoming and MCBs as outgoing complete all as specified and as directed. Note:- MCBs will be measured and paid saperately under relevent item of BOQ.
PRIME COST SUM. The prime cost is to used as directed by the Accepting Officer vide condition 1(v) and 5 of IAFW-2249. (a) Provide a prime cost of Rs. 9,00,000.00 for Provision six sets of Steel Roller Treadway (Each Set consists of two Nos Steel Roller) in all the 03 Igloo Buildings as approved by GE. (b) The contractor is to quote the amount in the money column i.e. in Col 'F' adding his overhead and profit. The amount shall be adjusted proportionately to the sum actually expended against Prime Cost Sum. Notes :- (i) Item(s) covered under Prime COst Sum shall be ordered as per condition 5 of IAFW-2249. (ii) Contractor shall quote amount adding over the amount of prime cost sum to cover his overhead and profit against Srl Item No 15.41(a).
SCHEDULE "A" PART-XIV (SCHEDULE OF CREDIT) Note :- Amount of Rs. 190700.00 indicated in Tender shall be deducted from the total quoted amount of BOQ.
AKM CONSTRUCTION AND ENGINEERING LLP
M/s Capiotal Enterprise
MAA BHAGWATI ASSOCIATES
M.P. Khaitan
FRIZO INDIA PVT LTD
Saru Enterprises Pvt Ltd
Rabina Enterprises Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid