Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 331 TOWER A SPAZE I TECH PARK SECTOR 49 SOHNA ROAD GURGAON 122002 | GURGAON | GURGAON | HARYANA | 122002 | ₹1.4 Cr | L1 | Accepted-AOC M/s Utility Services L1 |
| 2 | L2₹1.4 CrRejected-Finance | ₹1.4 Cr | L2 | Rejected-Finance Reject |
| 3 | L3₹1.5 CrRejected-Finance | ₹1.5 Cr | L3 | Rejected-Finance Reject |
| 4 | L4₹1.5 CrRejected-Finance | ₹1.5 Cr | L4 | Rejected-Finance Reject |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | WEATHER CONDITIONERS L3 | UTILITY SERVICES L4 | GLOBAL ENGINEERS L1 | NEXUS ENTERPRISE L2 |
|---|---|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing and Commissioning of Modular Type outdoor units, equipped with Highly Efficient Scroll, all Inverter Compressor(s), special heat exchanger, Y- branch as required, outdoor unit support, auto check function for connection error, auto address setting,Refrigerant temperature control and capacity as mentioned below. VRV/VRF System shall be suitable for working on 50°C ambient temperature, Refrigerant R 410A. | |||||||
| 1.01VRV/VRF System shall be suitable for working on 50°C Ambient Temperature, with Refrigerant R-410A. Unit price shall be inclusive of full charge of Refrigerant Gas & Oil, Freight, Insurance as applicable In INR. (Make: Daikin, / Toshiba / Mitsubishi Electric / O General) Complete in all respect with the prior approval of Engineer In Charge. | |||||||
| 1.02The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identical to the ODU. | |||||||
| 1.03The ODU shall have refrigerant cooled PCB Chamber for better operation at high ambient temperature | |||||||
| 1.04The system shall deliver at least 87% of mentioned nominal capacity at 43 Deg C ambient temperature. | |||||||
| 1.05The Fan static pressure of ODU shall be minimum 75 Pa to avoid hot air accumulation. | |||||||
| 1.06 | 40 HP (20 HP + 20 HP ODU UNIT) | 8 | Nos | 7,33,932 ₹58.7 L | 5,09,000 ₹40.7 L | 7,24,128 ₹57.9 L | 6,70,000 ₹53.6 L |
| 2.00Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make: Daikin, / Toshiba / Mitsubishi Electric / O General) Complete in all respect with the prior approval of Engineer In Charge. | |||||||
| 2.01 | 1.0 TR or 1.25 HP (or above) 4 - way Cassette Unit | 2 | Nos | 33,648 ₹67,296 | 39,500 ₹79,000 | 32,083 ₹64,166 | 40,550 ₹81,100 |
| 2.02 | 2.56 TR or 3.2 HP (or above) 4 - way Cassette Unit | 13 | Nos | 41,863 ₹5.4 L | 45,000 ₹5.8 L | 40,856 ₹5.3 L | 43,700 ₹5.7 L |
Tender Value
₹1.6 Cr
EMD Value
₹3.3 L
Closing Date
7 Jul 2025, 3:00 pmClosed
Ajay Taneja
Superintending Engineer,JCBUSTYMCA
Supply, Installation, Testing and Commissioning (SITC) of VRV Air-conditioning system for Library, MBA Block Building of the University.
2025_HRY_452522_1
2025A7B7A0B2 FED3 40A6 82A2 4E300AD62286419YMC
Open Tender
Civil Works
120 days
Faridabad (MC)
2 documents required · 2 mandatory
₹15,000
Yes
₹3.3 L
Yes
16 Dec 2025
17 Jun 2025
8 Jul 2025
17 Jun 2025
7 Jul 2025
17 Jun 2025
Amount
Supply, Installation, Testing and Commissioning of Modular Type outdoor units, equipped with Highly Efficient Scroll, all Inverter Compressor(s), special heat exchanger, Y- branch as required, outdoor unit support, auto check function for connection error, auto address setting,Refrigerant temperature control and capacity as mentioned below. VRV/VRF System shall be suitable for working on 50°C ambient temperature, Refrigerant R 410A.
VRV/VRF System shall be suitable for working on 50°C Ambient Temperature, with Refrigerant R-410A. Unit price shall be inclusive of full charge of Refrigerant Gas & Oil, Freight, Insurance as applicable In INR. (Make: Daikin, / Toshiba / Mitsubishi Electric / O General) Complete in all respect with the prior approval of Engineer In Charge.
The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identical to the ODU.
The ODU shall have refrigerant cooled PCB Chamber for better operation at high ambient temperature
The system shall deliver at least 87% of mentioned nominal capacity at 43 Deg C ambient temperature.
The Fan static pressure of ODU shall be minimum 75 Pa to avoid hot air accumulation.
40 HP (20 HP + 20 HP ODU UNIT)
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make: Daikin, / Toshiba / Mitsubishi Electric / O General) Complete in all respect with the prior approval of Engineer In Charge.
1.0 TR or 1.25 HP (or above) 4 - way Cassette Unit
2.56 TR or 3.2 HP (or above) 4 - way Cassette Unit
3.2 TR or 4.0 HP (or aboe) 4 - way Cassette Unit
4.0 TR or 5.0 HP (or above) 4 - way Cassette Unit
8.0 TR or 10.0 HP (or above) Ductable Unit
Supply & Fixing of Interconnecting copper refrigerant pipe work with thick duly insulated with Nitrile insulation between indoor and outdoor units as per specifications Approved Makes- Rajco/Mandev/Maxflow/JOBU Complete in all respect with the prior approval of Engineer In Charge.
9.5 mm dia (3/8) (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (1/2) (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (5/8) (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19.1 mm dia (6/8) (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (7/8) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
28.58 mm dia (11/8) (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
31.8 mm dia (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
34.9 mm dia (13/8) (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
41.3 mm dia (15/8) (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supply & Installation of Refrigerant R-410A to top up the system (Make: SRF / Honeywell / stallion) Complete in all respect with the prior approval of Engineer In Charge.
Supply, installation, testing and commissionig of refrigerant Copper Y-joints (Make: Daikin, / Toshiba / Mitsubishi Electric / O General) Complete in all respect with the prior approval of Engineer In Charge.
CONTROL AND TRANSMISSION WIRING: Supply and Laying of 2 core x 1.5 sqmm PVC insulated copper conductor communication control cable in PVC Conduit. Approved Make : Havells/ Polycab/ RR Kabel/ Anchor/ KEI Complete in all respect with the prior approval of Engineer In Charge.
POWER CABLE: Supply and Laying of 3 core x 2.5 sqmm PVC insulated copper conductor cable for indoor units. Approved Make : Havells/ Polycab/ RR Kabel/ Anchor/ KEI Complete in all respect with the prior approval of Engineer In Charge.
Supply, installation, testing & commissioning of cubical type main MV panel board suitable for 3 Phase, 50 Hz and of 35 MVA rupturing capacity at 415 volts, fabricated from minimum 2mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with following mountings, interconnections etc. as required. (GA drawing of panel to be provided before fabrication). Panel shall be Floor mounted type with cable entry at the top and IP-65 Degree of protection. Panel shall be powder coated having colour shade RAL-7032. including the following switch gear and components: Approved Make : Havells/ Polycab/ RR Kabel/ Anchor/ KEI Complete in all respect with the prior approval of Engineer In Charge.
INCOMER: 1200A TPN EDO ACB - 01 Nos
OUTGOINGS: 100A FP MCCB 10KA (FOR VRF ODUs) - 16 Nos
16A Dual Pole MCB 10KA(FOR VRF IDUs) - 75 Nos
Providing and fixing of MS Stand for Outdoor Units to be fabricated & painted at site Complete in all respect with the prior approval of Engineer In Charge.
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular ducting complete with supportings etc. as per approved drawings and specifications of following sheet thickness complete as required. Approved Make : Jindal/TATA/SAIL Complete in all respect with the prior approval of Engineer In Charge.
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
DUCT ACOUSTIC INSULATION Supply, Installation, Testing and Commissioning of Acoustic lining inside ducts of following thickness Complete in all respect with the prior approval of Engineer In Charge.
10mm thick
DUCT THERMAL INSULATION Supplying and installation of thermal insulation od ducts of following thickness of Nitrile rubber (Class "O") insulation Complete in all respect with the prior approval of Engineer In Charge.
19 mm thick
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications Complete in all respect with the prior approval of Engineer In Charge.
Supplying & fixing of powder coated extruded aluminium Return/Exhaust Air Grills with louvers but without volume control dampers complete as required Complete in all respect with the prior approval of Engineer In Charge.
Bidder Name
Amount
WEATHER CONDITIONERS (GSTN-06AFXPA1351C2ZT) BID ID -1288400
UTILITY SERVICES (GSTN-07AABFU8051C2ZD) BID ID -1289879
GLOBAL ENGINEERS (GSTN-NA) BID ID -1290702
NEXUS ENTERPRISE (GSTN-NA) BID ID -1282456
GLOBAL ENGINEERS (BID ID -1290702)
NEXUS ENTERPRISE (BID ID -1282456)
WEATHER CONDITIONERS (BID ID -1288400)
NEXUS ENTERPRISE (BID ID -1282456)
WEATHER CONDITIONERS (BID ID -1288400)
UTILITY SERVICES (BID ID -1289879)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid