| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.8 L+₹77,843.38 (1.62%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹50.5 L+₹2.5 L (5.27%)Rejected-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L3 | Rejected-AOC Rejected | |
| 4 | Not Admitted-Fee/PreQual/Technical 15 5 1ST MAIN 2ND CROSS K S TOWN BANGALORE BANGALORE RURAL KARNATAKA 560060 | BENGALURU URBAN | KARNATAKA | 560060 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
25 Nov 2020, 6:00 pmClosed
BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
SPECIAL REPAIRS BLDG TO ROOF TREATMENT JOINERIES AND INTERNAL ELECTRIFICATION IN BLDG NO P 42 ML LINES AT PRTC PROVN OF TDN SHOP ADDITION ALTERNATION TO BUILDING NO 128 AT CQAL AND CERTAIN REVENUE AND MINOR WORKS UNDER GE NORTH BANGALORE
2020_MES_384975_2
8474
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Class D Category a(i) b(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹86,000
Yes
21 Dec 2020
6 Nov 2020
27 Nov 2020
6 Nov 2020
25 Nov 2020
13 Nov 2020
6 Nov 2020 - 12 Nov 2020
Amount
B/R WORKS
Complete removal of existing roof treatment (tarfelt) and removing to a distance n.exc. 50m complete all as specified and as directed.
Plain Cement Concrete (1:2:4), type B-1 using 20mm graded stone aggregate as in floors, 40mm thick finished even and smooth with out using extra cement complete all as specified and as directed.
Rendering 15mm thick on fair faces of PCC padding concrete in CM(1:4) finishing the surfaces even and smooth with out using extra cement mixed with approved water proofing compound complete all as specified and directed. NOTE :- WPC will be measured and paid separately.
Supply only liquide water proofing compound complete all as specified and as directed.
Roof treatment by applying bitumen primer @ 0.27kg/sqm, providing 3mm thick APP modified water proofing membrane weighing not less than 3.8 kg/sqm reinforced with non woven polyester matt weighing not less than 180gm/sqm, having softening point not less than 140 centigrade, having tensile strength of 650 N/sq.cm in longitudinal and transverse directions, the reinforced tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm end lap applying a coat of blown grade hot bitumen VG-10 over the membrane @ 1.2kg/sqm, top of membrane shall than be finished with solar reflective bituminous aluminium paint @0.10kg/sqm all as specified and as directed.
Taking down shutters of any description area exc. 1 sqm but not exc. 2 Sqm each complete all as specified and as directed.
Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid rounded or chambered, put together with glue pinned at joints complete all as specified and directed.
35mm thick plain framed panelled factory made shutters with II class hardwood rail and style with lock rail and panel of 9mm BWP commercial ply with commercial vaneer on both faces. The size of rail and stile as per IS : 1003 (Part-I)1991 kiln seasoned and chemically pressure treated wood complete all as specified and directed.
35 mm thick factory made door shutters, 2nd class hard wood fully glazed skeleton shutter, open rebated and prepared to receive glass, gauge etc., divided into squares with plain chamfered, mitred and rebated sash bars any numbers fitted with cut and mitred beads for securing glass etc complete all as specified and as directed.
Rolled Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and as directed.
Mild steel black sheet 1mm thick as in covering to door shutter cut to size, edges beaded if directed, hole punched incl round headed screws incl beading turning up metred angle, stopped ends etc complete all as specified and directed.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples fixed in repairs complete all as specified and as directed.
Hacking out old broken glass of any thickness, size, quality or description from metal / wooden frame works or stone / concrete/ brick surrounds including punching or drilling out old glazing pins/spring clips or fixed with wooden beading etc complete all as specified and as directed.
3.0 mm thick sheet glass, ordinary quality and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in wooden frames in squares not exceeding 0.5 sqm in each pane all as directed.
Mild Steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans and similar small articles conforming to Fe-290 Gde-E-165 complete all as directed.
Plain Cement Concrete (1:2:4), type B1, using 20mm graded stone aggregate as in copings, bed blocks, hold fasts, steel frame of window back filling, roof kerbs of mud stops, rounded or chamfered on edges cills and steps etc., complete all as specified and directed.
Aluminium anodised barrel towel bolts of extruded section of length 200 mm complete all as specified and as directed.
300mm long Aluminium alloy anodised sliding door bolt (Aldrop bolt) with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed etc complete all as specified and as directed.
Mild steel butt hinges medium weight 100mm long, cold rolled all as specified and as directed.
150mm long Aluminium handles fabricated type complete all as specified and as directed.
Taking down cement plaster with/without tiling on brick or concrete surfaces including racking out joints hacking for key scrubbing down with water etc and disposal of debris outside MD land all as specified and as directed.
15mm thick rendering on brick or concrete surface in cement mortar (1:6) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in CM (1:4) on other than fair face of brick or concrete surface, surface to be finished even and fair with out using extra cement all as specified and as directed.
Preparation of new plaster surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of oil bound emulsion distemper over a coat of primer on wall complete all as specified and directed.
Preparation of old treated plastered or unplastered wall surfaces of any description including brooming down with steel wire brushing scrapping down smoke soot’s, moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying one coat of oil bound emulsion distemper on wall surfaces all as specified and as directed.
Preparation of old treated plastered or unplastered wall surfaces of any description including brooming down with steel wire brushing scrapping down smoke soot’s, moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying one coat of cement based paint on wall surfaces all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer all as specified and as directed.
Preparation of old treated ceiling surfaces of any description including brooming down with steel wire brushing scrapping down smoke soot’s, moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying one coat of white wash on internal surfaces all as specified and as directed.
Preparation of new or previously untreated wooden surfaces of any description not other wise described over 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed.
Demolition in cement concrete (unreinforced) in ground floor and pavings n.exc. 15 cm thickness (above ground level) and disposal of debris outside MD land all as specified and as directed.
Reinforced cement concrete, M-25(Design mix) as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed.
Glass dividing strips, 3 mm thick, 38mm wide inserted in position, conform to design complete all as specified and as directed.
Plain Cement Concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in plinth protection, 75mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints complete all as directed.
Taking up or down steel tubing 15mm dia and connections including removal to store all as directed.
Taking up or down steel tubing 20mm dia and connections including removal to store all as directed.
15mm dia medium grade Galvanised iron tubing with all fittings and fixed to wall, ceiling or laid in floors etc complete all as directed.
20mm dia medium grade Galvanised iron tubing with all fittings and fixed to wall, ceiling or laid in floors etc complete all as directed.
15 mm bore cast copper alloy chromium plated bib taps, fancy type, long body with capstan head handle, screwed down for iron pipe or for brass ferrule fixed in repairs all as specified and as directed.
15mm bore stop valves cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends or for unions etc all as specified and as directed.
Gratings of size 125 mm dia with waste hole of PTMT all as specified and as directed.
PVC valveless, syphonic action type, flushing cistern, 10ltr capacity,low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, complete all as specified and directed.
PVC connections 15mm dia with PTMT nuts of length of 450 mm long fixed in repairs complete all as specfied and as directed.
Vitreous china wash hand basin, white, flat back of size 630 x 450 mm excluding taps,chain and plug and porcelain stopper but including CI brackets etc., complete all as specified and as directed.
15 mm dia cast copper alloy chromium plated Pillar tap with long shank and fly nuts, fancy type screwed for iron pipe and fixed complete all as specified and as directed.
PTMT waste coupling of 32 mm dia (half or full threaded) including taking down old coupling of any description complete all as specified and directed [Minimum weight for 32 mm – 45 gms].
PVC corrugated waste pipe 40mm dia, 800mm long fixed in repairs complete all as specified and as directed.
Tubular towel rail 450mm long of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (Min Wt 170 Gms) etc completed all as specified and as directed.
Brass chromium plated overhead shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union fixed in repairs complete all as specified and as directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in hard/dense soil complete all as specified and as directed.
Plain Cement Concrete as in foundation filling and mass concrete (1:4:8), type D-2, using 40 mm graded stone aggregate complete all as specified and as directed.
Reinforced cement concrete, M-25(Design mix) as in foundation for footings and plinth beam complete all as specified and as directed.
Reinforced cement concrete, M-25(Design mix) as in columns, pillars, piers, posts, struts and the like complete all as specified and as directed.
Reinforced cement concrete, M-25(Design mix) as in beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified and as directed.
Reinforced cement concrete, M-25(Design mix) as in slabs supported on walls, beams, and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Reinforced cement concrete, M-25(Design mix) as in chajja, facia and the like complete all as specified and as directed.
Precast Reinforced Cement Concrete (1:2:4), type B1, using 20mm graded stone aggregate as in shelves and similar articles with plain facese set in CM (1:4) complete all as specified and as directed.
Steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
Steel formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete complete all as specified and as directed.
Steel formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as specified and as directed.
Steel form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work n.exc. 200mm thick (horizontal or sloping) as in flat and rough finished surfaces of concrete complete all as specified and as directed.
Steel form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc. 20 cm wide and sides of RCC/PCC bands in walls, horizintal or sloping and similar work exc. 10 cm but n.exc. 20cm wide complete all as specified and as directed.
Steel form work to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed.
TMT steel bars 10mm dia and over cut to length bent to shape required, including, cranking, bending spirally for hooping, for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per Sl Item No. 1.067 here in before but 6mm to 8mm dia.
All as per Sl Item No. 1.067 here in before but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders.
Filling only excavated earth under floors including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. NOTE :- Soil obtained from excavation under Sl Item No 1.053 here-in-before shall be used for filling.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thickness as in hard/dense soi; complete all as specified and as directed.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n. exc 1.5 m above the starting point.
Precast cement concrete block masonry with solid blocks exc. 10 cm in width and setting in cement mortar 1:6 type C1 1:3:6 ( using 20 mm graded aggregate) complete all as specified and as directed.
Precast cement concrete block masonry with solid blocks n.exc 10 cm in width (with plain or interlocking joints as directed) and setting in cement mortar 1:4 type C1 1:3:6 (using 20 mm graded aggregate) complete all as specified and as directed.
10mm thick rendering on brick or concrete surface in cement mortar (1:6) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
Rendering 5 mm thick on ceiling /RCC surfaces in cement mortar (1:3), finishing the plastered surfaces even and smooth without using extra cement all as specified and as directed.
Rendering 15mm thick consisting of two coats of 5mm thick in CM(1:4) over a coat of 10 mm thick in CM(1:4) mixed with water proofing compound as per manufacturers instructions finishing the surfaces even and smooth without using extra cement including necessary scaffolding complete all as specified and directed. NOTE:- WPC will be measured and paid separately under reelvent items.
Preparation of newly plastered ceiling surfaces of any description and applying three coats of white wash complete all as specified and directed.
Steel windows of box type, with frame of 80 x 60mm and1.25mm profile sheet with box type shutters consisting of inside glazed shutter and out side gauged shutter with steel handle, telephonic peg stay complete with glazing bars of 08 Nos with 10 x 10mm mild steel square guard bars in equal spacing, devotailed or welded all as per TD Drg No. 539 sheet 1/3 to 3/3 including one coat of red oxide primer all as specified and directed. NOTE :- PCC in frame, glass pane and wire mesh will be measured and paid separately under relevant items.
Steel ventilators with top hung shutter including hinges, steel peg stay as per TD drg no 539 sheet 1/3 to 3/3 complete all as specified and directed
18 mm thick (7 Nos of ply) plywood grade BWP, type BB with decorative laminate type 1 of surface finish, having 0.9 mm thick , colour and pattern as approved, fixed with approved adhesive as per manufactures instructions, fixed with screws to timber frame work,alround 6mm thick teak fillets fixed in kitchen cabinet or cupboards complete all as specified and as directed.
Second class hard wood plain fillets exc. 13 sq.cm and n.exc. 25 sq.cm sectional area, square, rectangular or triangular in section wrought, secured with screws or brads, fixed to cupboard shutters all as specified and as directed.
75 mm size hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws,fixed in repairs complete all as specified and as directed.
Aluminium butt hinges type C-21, 100mm long complete all as specified and as directed.
Aluminium butt hinges type C-21, 75mm long complete all as specified and as directed.
Aluminium anodized handles 75 mm size cast type all as specified and as directed.
Aluminium anodised barrel towel bolts of extruded section of length 150 mm complete all as specified and as directed.
Mild steel 300mm long, ordinary rat tail rod pattern springs,including roller and roller plate complete all as specifed and as directed.
4.0 mm thick sheet glass, ordinary quality and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in wooden frames in squares not exceeding 0.5 sqm in each pane all as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 1000 ltrs capacity complete all as specified and as directed.
Bib taps standard of PTMT, any colour screwed for iron pipe suitable for 15mm dia fixed in repairs all as directed.
20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed(Min weight 20mm-210 gms) all as specified and as directed.
32 mm dia waste fittings, brass, chromium plated for sinks, basins, etc., with long screwed shanks and flynuts, flange end fixed in repairs complete all as specified and as directed.
Cast Iron floor trap, with grating including jointing to waste pipe fixed in Plain Cement Concrete, type B-1 (1:2:4) suitable for 75mm dia of outlet pipe complete all as specified and as directed.
PVC (SWR) gully trap 125/110mm setting and jointing in solvent cement complete all as specified and as directed.
75 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps all as specified and as directed.
75mm bore PVC (SWR) bends with access door complete all as specified and as directed.
Hard core of guage n.exc. 63mm deposited spread and levelled, laid in layers n.exc. 15cm thick, watered and rammed to a true surface using broken boulders all as specified and as directed.
Plain Cement concrete (1:4:8), type D2, using 40mm graded stone aggregate as in sub bases of floors, 75mm thick, complete all as specified and directed.
Plain Cement Concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in floors 25mm thick, as in sub base to floor complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick(square/rectangular) area of each tile exceeding 0.11 sqm but n.exc.0.36 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed.
Glazed coloured ceramic tiles as in vertical surfaces 350 x 250x 7 mm/ 450 x 350 x 7 mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including backing coat 10mm thick backing coat in CM (1:4) on fair faces of brick work or concrete surfaces complete all as specified and as directed.
25mm thick Granite work (of any type), table rubbed and polished as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Anti termite treatment of soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
Anti termite treatment along the external pheriphery of wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed.
Anti termite treatment to the back fill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (area of the substructure in contact with backfill to be measured) complete all as specified and as directed.
Anti termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
Anti termite treatment to the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Chequered cement concrete tiles 300 x 300 x 25mm thick, coloured of approved pattern and design, set and jointed in neat cement slurry and pointed with white cement and pigments laid over screed bed or bedding layer of 20mm thick in cement mortar (1:6) complete all as specified and as directed.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) as in roofs, floors (other than ground floors), beams staircases, landing, chajja and similar suspended work complete all as specified and as directed.
Excavating in trenches, n. exc 1.5m wide and n.exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Taking down chowkat (without taking off shutter from the frame) area exc. 1.5 sqm and n.exc. 4.00 sqm each including making good the disturbed surface in PCC (1:2:4) type B0 or CM (1:3) complete all as specified and as directed.
Pressed steel frames of size 100x60x1.25 mm for doors with one or more rebates(02 rebates) including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified and as directed.
Demolition of cement concrete of any description and in any position and otherwise specifically provided for incl existinig treatement if any, complete all as specified and as directed.
Cutting openings through stone walls for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for underpinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the premises, old masonry walls built in cement mortar complete all as specified and as directed.
Forming jambs, etc., to openings (to foregoing item), with stone supplied by MES including cutting, toothings and properly bonding into old work, including facing and pointing (if necessary) to match existing work, complete, new work built in cement mortar (1:4) complete all as specified and as directed.
Making good under cills (or over arches, lintels and bressummers) including all pinning as necessary, new work built in cement mortar (1:4) complete all as specified and as directed.
Removing building materals out side MD land including loading, unloading complete all as specified and as directed.
Excavation in post holes each 0.50 cum getting out , returning filling in layers not exceeding 25cm including watering and ramming and removing surplus earth to a distance not exceeding 50 metre complete all as specified.
Plain Cement Concrete as in foundation filling and mass concrete (1:2:4), type B2, using 40 mm graded stone aggregate complete all as specified and as directed.
Rolled mild steel joist, channel, angle or tee sections grade Fe 410-W Gde E-250 quality-A, fixed independently, with out connecting plates etc., (cut to ordinary lengths) complete all as specified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specifed and as directed.
60mm thick Machine pressed precast cement conctete interlocking paver block any shape and size, conforming to IS 15658-2006 of M-35 Grade of design and pattern as approved, set over and including 75mm sand cushion, over rammed earth complete all as specified and as directed.
Brick work in cement mortar(1:4) using sub-class 'B' old size bricks straight or curved on plan to any radius in half brick thick walls complete all as specified and as directed.
Rolled Mild steel work as in hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and counter shunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 all as specified and as directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n.exc. 5cm long and dia of shank 5 to 10 mm complete all as specified and as directed.
Supply only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire
Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc all as specified and as directed. NOTE:- Each line of wire shall be measured for payment purpose.
Excavating over areas, n.exc. 1.5 m deep and getting out soft/loose soil all as specified and as directed.
Steel formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, fair finished surfaces of concrete complete as specified and as directed.
Taking up or down steel tubing 50mm dia and connections including removal to store all as directed.
50mm dia medium grade Galvanised iron tubing with all fittings and fixed to wall, ceiling or laid in floors etc complete all as directed.
Gun metal gate or globe valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
E/M WORKS
Taking down carefully aluminium / copper wiring / power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc including painting with same colour of the back ground complete all as specified and as directed.
Point wiring complete with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit of medium grade including accessories surface / concealed type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly all as specified and as directed for:- (a) one light / fan point controlled by one switch / regulator .
(b) One 3 pin socket out let 5 Amps on independent board
(c) one 3 pin socket out let 5 A on same board
Point wiring complete with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit incl accessories surface /concealed type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Note for Sl Item No. 2.002 to 2.005 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring.
Switch Piano, flush type, 5 Amps, 240 Volts single pole with ISI marked complete all as specified and as directed.
Switch socket combination 2 in 1, 3 pin and 2 pin, 5 and 15 Amps flush type, universal complete all as specified and as directed
Switch socket combination 3 & 2 pin, 5 Amps, 240 Volts, flush type multipurpose controlled by one switch all as specified and as directed.
LED batten suitable for indoor applications 18/20 Watts, 4 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories all as per Bajaj Cat No. BCLSB 18 WH / Halonix Cat No. HLB-07-20-CW-IP or techno commercially equivalent makes specified in PS including taking out old fittings all as specified and directed.
Ceiling rose, surface bakelite type, 65 x 50 mm, 2 to 3 terminals all as specified and as directed.
Angle holder PVC/polycarbonate type all as specified and as directed.
Dismantling, greasing & painting of ceiling fans complete, in situ and spray painting with one coat of synthetic enamel paint including filling cavities with one filler coat after cleaning all dust etc. and re-fixing with downrod & clamps complete all as specified and as directed.
MCB single pole 240 Volts, 5 to 40 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB single pole and neutral 240 Volts, 5 to 40 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
LED building security light fitting 25 Watt with pressure die cast housing, toughened glass and indivudial LEDs with secondary optics and IP 66 protection all as per Bajaj Cat No..Cat No.:- BCLST 25W LED I / Halonix Cat No. HLSD-09H-25-CWL-R or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Brackets made out of GI tubing medium grade 40mm bore of 1.5 mtr length bent to required shape and pattern to mount the street light, including MS clamps made out of MS flat iron 25 x 10mm, nuts, bolts, washers etc and applying two coats of alumium paint over a coat of red oxide primer complete all as specified and as directed.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
Excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole, laying of pipe lines etc complete all as specified and as directed.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard / dense soil etc complete as specified as directed.
Removing the excavated material to a distance exc. 50m but n. exc. 100m and depositing where directed at a level n. exc. 1.5m above the starting point.
Sand cushioning in layers for cables in trenches / ducts for cable including consolidation complete all as specified and as directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq.mm 3.5 core connected with suitable lugs, gasket all as specified and as directed.
Boring of holes under road, pavement, hard standing by trenchless technic and nessary machine including inserting of HDPE pipe of bore 100mm dia, excavation at ends complete all as specified and as directed.
Galvinised iron tubing, light grade, 50mm bore with all accessories for cable protection fixed on poles/buildings or laid in trenches including necessary MS clamps, bolts and nuts etc., complete all as specified and as directed.
LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories all as per Bajaj Cat No. BCLSB 10 WH / Halonix Cat No. HLB-07-10-CW-IP or techno commercially equivalent makes specified in PS including taking out old fittings all as specified and directed.
Stepped type electronic fan regulator flush socket type all as specified and as directed.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable 2 single core of size 2.50 sq.mm, earth continuity conductor of size 2.50 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade on surface / concealed in walls / roof / floors complete all as directed. NOTE:- Two wires of 2.50 sq.mm and one wire of 2.50 sq.mm and one run of PVC conduit shall be measured as one unit.
FRP cable looping boxes of size 240mm x 130mm x 110mm with PVC sheet finish inside, including MCB SP, 10 Amps,1 No, heavy duty PVC connector 4 way terminal strip 01 No and fixed to pole with suitable size clamp with nuts,bolts complete all as specified and as directed.
Galvinised iron tubing, light grade, 40mm bore with all accessories for cable protection fixed on poles/buildings or laid in trenches including necessary MS clamps, bolts and nuts etc., complete all as specified and as directed.
XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq.mm 3.5 core connected with suitable lugs, gasket all as specified and as directed.
LED street light fitting 60 Watt including lamp, new generation energy saving and environmental friendly long life versatile pressure die cast aluminium IP-66 roadway luminaire with high power LED as light source with toughened glass. all as per Havells Cat No. ENDURA PEARL PLUS SL60 WLED 757 SASYTOPC HSN Code: 9405 or Bajaj Cat No BRTFG 60W LED V3 complete all as specified and as directed.
Exhaust fan 230Volts, AC, SP, 300 mm sweep,1400 RPM metalic body, high speed, heavy duty complete with louvers, clamps with screws nut and bolts, including making core cutting, wire connections from ceiling rose to exhaust fan complete with accessories all as per Usha Cat No. S.PH TURBO HDEF 1400RPM ISI or techno commercially equivalent makes specified in PS including writing of MES No with Unit Name on Exhaust fans using approved stencil with synthetic enamel paint all as specified and as directed.
Energy saving ceiling fans, 230 Volts, 26 Watts, single pole, 1200 mm sweep, high speed of approved colour with remote control and two years warranty certificate from the manufacturers, with latest BEE five star rating and BLDC technology all as per Havells Model No :- Efficiencia Neo (BLDC 26W) or techno commercially equivalent models specified in PS complete with down rod and GI hook with welding work, wire connections from ceiling rose to ceiling fans, with complete accessories including writing of MES No with unit name on ceiling fans using approved stencil with synthetic enamal paint complete all as specified and as directed.
MCB DB TPN 4 Way with double door type 415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed.
MCB TPN 415 volts 63 Amps complete all as specified and as directed
Galvanised iron pipe of 25 mm dia, medium grade, laid in trenches with all fittings such as socket, bends, elbow, union etc., including dismantling the old un serviceable pipe complete all as specified and as directed.
Gun metal gate or globe valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
25mm bore dia brass ball valves high pressure with polythene float and flynut complete screwed for iron pipe of size complete all as specified and as directed,
Point wiring complete with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and including sunken boxes, PVC frame cover plate for mounting of modular switches /sockets as required at site, non-metalic rigid PVC conduit of medium grade including accessories concealed type run on walls/ ceiling, including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly all as specified and as directed for:- (a) one light point controlled by one switch.
(b) one fan point controlled by one switch.
(c) One 3 pin socket out let 5 Amps on independent board.
(d) one 3 pin socket out let 5 A on same board.
All as per Sl Item No. 2.040 here-in-before but for 16 Amps socket outlet by using 2.5 sq.mm PVC insulated unsheathed FRLS copper conductor multi stranded on independent board including provn of 2.5 sq.mm PVC insulated solid copper conductor continus as earth wire.
Modular type switch 6 Amps, one way, one module complete all as specified and as directed.
Modular type switch 16 Amps, one way, one module complete all as specified and as directed.
Modular type socket outlet, 6 Amps, two module complete all as specified and as directed.
Modular type socket outlet, 6/16 Amps, two module complete all as specifiedand as directed.
Modular type fan regulator stepped type, 80 Watt, two module complete all as specified and as directed.
Skyline LED fitting 30 Watt building security light having high power LED with pressure die cast complete all as specified and as directed.
Recess mounted LED luminaries 36 Watts complete with all accessories all as per Wipro Cat No. CRCO 23 RO36HP65G1/ Havells Cat No. .PLUTO NEO 2X2PLR34WLED840S or techno commercially equivalent makes specified in PS complete all as specified and directed.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable two single core of size 6 sq.mm, earth continuity conductor of size 6 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade on surface / concealed in walls / roof / floors complete all as directed. NOTE:- Two wires of 6 sq.mm and one wire of 6 sq.mm and one run of PVC conduit shall be measured as one unit.
Sheet metal enclosure single pole and neutral with a two pin earth plug and socket with one single pole MCB 32 Amps, 230 Volts AC complete all as specifeid and directed.
XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq.mm 3.5 core connected with suitable lugs, gasket all as specified and as directed.
Hi wall split type AC with indoor and out door units, 1.5 TR capacity complete with cordless remote control unit, with in built air ioniser and Plasma filter for better indoor air quality with 5 star rating and EER 3.2.including supply, installation, testing and commissioning complete all as specified and as directed.
Voltage stablizer for automatic operation, single phase, naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with out put voltage stabilized at 230 volts with accuracy + 2.5 % and capacity of 5 KVA complete all as specified and as directed.
Provision of Bed side locker steel all as per drawing No FD-1029 complete all as specified and as directed.
CIMFR certified LED flame proof batten fittings suitable for single T8 tube of 20 Watt for gas / vapour group of IIA & IIB and Zone 1 & 2 with IP-65 protection complete with all accessories including LED tube all as per Crompton Cat No.EXTN1LT8-20, FIAMMA II or techno commercially equivalent makes specified in PS complete all as specified and directed.
XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq.mm 2 core connected with suitable lugs, gasket all as specified and as directed.
Plain Cement Concrete, (1:4:8), type D2 using 40mm graded stone aggregate as in pole foundation, stay assembly, including necessary form work all as specified and as directed.
Plain Cement Concrete, (1:3:6), type C1 using 20mm graded stone aggregate in coping of poles/filling road cutting, stays, including necessary form work all as specified and as directed.
Excavation in trenches in hard/dense soil not less than 1.5 mtr deep and not exc 3 mtr in deep for pole foundation etc complete all as specified and as directed.
Street light fittings, 1x 60 Watt LED, 5700K with high power LED, pressure cast aluminium IP-66 peanut lens to ensure uniform distribution complete all as per Bajaj cat part No. BRLEP60W Version II or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Brackets made out of GI tubing medium grade 25mm bore of 1.25 mtr length bent to required shape and pattern to mount the street light, including MS clamps made out of MS flat iron 25 x 10mm, nuts, bolts, washers etc and applying two coats of alumium paint over a coat of red oxide primer complete all as specified and as directed.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable 2 single core of size 1.50 sq.mm, earth continuity conductor of size 1.50 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade on surface / concealed in walls / roof / floors complete all as directed. NOTE:- Two wires of 1.50 sq.mm and one wire of 1.50 sq.mm and one run of PVC conduit shall be measured as one unit.
Pre-stressed concrete ploe, 9.0 metres long, 102 mm x 152 mm at top and 102 mm x 289 mm at bottom, class 10 and 1000 mm single arm bracket welded along with the pole with necessary clamps bolts and nuts errecting and cable connection from pole junction box to fittings including necessary earth work complete all as specified and as directed.
Loop to loop out junction box of Junction box fixed on wall /poles of suitable size made out of PVC box of size 300 x 200 mm with weather proof hinged door with PVC connector 4 pole controlled by one single pole MCB SP 6 to 30 Amps capacity (including supply of MCB) at the end complete all as specified and as directed. Make : Sintex / Indo Asian /Hensel
Exhaust fan, AC single phase 230/ 240 V of size 230 mm sweep with louvers fixed outside with all accessories all as per Usha cat part No. AEROCLEAN PLUS DBB GBD or techno commercially equivalent makes specified in PS including cutting the exisiting stone wall and making hole for fixing of exhaust fan and finshing the portion with necessary plastering, white washing and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed. NOTE :- Quoted rate deemed to be include Opening of wall and making good the disturbed surface and all neccessary fixing arrangement including nut,bolt and washers.
SREE VARU ELECTRICALS
S S BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .