| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.8 LAccepted-AOC 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L1 | Accepted-AOC Accepted being reasonable and lowest | |
| 2 | L2₹80.5 L+₹2.8 L (3.55%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹82.6 L+₹4.9 L (6.26%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹88.1 L+₹10.4 L (13.4%)Rejected-Finance 27 2 1ST MAIN ROAD GOKULA 1ST STAGE 1ST PHASE BANGALORE 560054 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560054 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹89.4 L+₹11.7 L (15.0%)Rejected-AOC | L5 | Rejected-AOC Rejected being not lowest |
Tender Value
₹75.5 L
EMD Value
₹1.4 L
Closing Date
11 Jun 2020, 6:00 pmClosed
CWE Ranchi
HQ CWE RANCHI MES DIPATOLI CANTT PO RMCH RANCHI - 834009
PROVN OF 500 KVA TRANSFORMER AND THREE PHASE SILENT DG SET AT MH UNDER GE DANAPUR
2020_MES_343822_1
80599/1292/E8
Open Tender
Power/Energy Projects/Products
Item Rate
180 days
DANAPUR CANTT
Class C and above category b (ii)
7 documents required · 7 mandatory
₹1,000
Yes
GE DANAPUR
₹1.4 L
Yes
17 Aug 2020
13 May 2020
15 Jun 2020
13 May 2020
11 Jun 2020
4 Jun 2020
Amount
Supply, installation, testing and commissioning Indoor type, step down transformer of 500 KVA capacity,11 KV/433 Volts (at no load) AC 3 phase, 50 HZ, double copper wound type core, oil immersed, naturally cooled, oil natural Air Natural(ONAN) with external cooling tubes delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group Dyn-11 with neutral brought out on secondary side (LV) and having trapings at (-) 15% & +5% on HV side to changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after cotinuous full load run on an ambient temp of 40 degree celsius in oil as prevalling at site. The transformer shall be complete with the fittings and accessories comprising of items as mentioned in Annexure -1 of Schedule A - Note :- Annexure -1 of Schedule A is part of Scedule and uploaded with other tender documents.
Supplying, laying, jointing, testing and commissioning HT XLPE insulated, screened , PVC bended galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor screening with extruded semi conditioning layers insulation screening with copper tape cover laid upto with PVC (ST-2) extruded, inner sheathing galvanized steel strip armoured PVC (ST-2) outer sheathed cable confirming to IS-7098 (Pt-II) 11/6.35 KV grade suitable for earthed system cross sectional area 120 sqmm 3 core HT UG cable laid in trenches/through GI pipe/fixed along with pole complete all as specified & as directed.
Supply, fixing and testing Cable jointing kit for 11 KV grade cable for indoor termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 120 sqmm complete all specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 630 sq mm single core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm single core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed.
Supply, laying and testing cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, two or more core, ISI-7098 Marked, with aluminium conduc-tor multi stranded , heavy duty 1100 Volts grade of cross sectional area 400 Sqmm 3½ Core, laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. including necessary Clamps, nuts , bolts, washers etc complete all as specified and directed
Supply, laying and testing cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, two or more core, ISI-7098 Marked, with aluminium conduc-tor multi stranded , heavy duty 1100 Volts grade of cross sectional area 185 Sqmm 3½ Core, laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. including necessary Clamps, nuts , bolts, washers etc complete all as specified and directed
Supply, laying and testing cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, two or more core, ISI-7098 Marked, with aluminium conduc-tor multi stranded , heavy duty 1100 Volts grade of cross sectional area 150 Sqmm 3½ Core, laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. including necessary Clamps, nuts , bolts, washers etc complete all as specified and directed Note for items No 2 to 8- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block, and pipe shall be measured and paid separately under appropriate items
Supply, installation, commissioning and testing LT Panel Board factory made CPRI approved panel, weather, dust & vermin proof indoor cubical compartmental type, double door, front and back side openable, with providing rubber/PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/sleeves with maintained the colour code and copper strip busbar of suitable rating to ACB input and ACB output of suitable length, made out of 2.00 mm thick mild steel CRCA sheet with 40 x 40 x 6mm size angle iron supporting frame and MC 75 channel base including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incomming including PCC foundation complete all as directed and specified and comprising of the following fitment accessories as mentioned in Annexure -2 of Schedule A - Note :- Annexure -2 of Schedule A is part of Scedule and uploaded with other tender documents.
Supply, installation, commissioning and testing LT Panel Board factory made CPRI approved panel, weather, dust & vermin proof indoor cubical compartmental type, double door, front and back side openable, with providing rubber/PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/sleeves with maintained the colour code and copper strip busbar of suitable rating to ACB input and ACB output of suitable length, made out of 2.00 mm thick mild steel CRCA sheet with 40 x 40 x 6mm size angle iron supporting frame and MC 75 channel base including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incomming including PCC foundation complete all as directed and specified and comprising of the following fitment accessories :- as mentioned in Annexure -3 of Schedule A - Note :- Annexure -3 of Schedule A is part of Scedule and uploaded with other tender documents.
Supplying, installation, testing and commissioning of Eco Friendly diesel engine driven Generating set as per IS of 400 KVA/320 KW capacity, 400/440 Volts AC, 3 phase, 50 HZ 4 wire 0.8 power factor directly coupled alternator and engine, water Cooled , common base platform with floor mounted fuel tank of suitable capacity, accoustic enlosure and including all excavation, PCC foundation, anti vibration pads/dampers complete with AMF Panel as directed by manufacture and other accessories, Make Kirloskar electric Co. ltd or equivalent of other makes specified comprising of the fitment & accessories as mentioned in Annexure -4 of Schedule A - Note :- Annexure -4 of Schedule A is part of Scedule and uploaded with other tender documents.
M&L for Earthing to panel complete with galvanised steel earth plate electrode (60cm x 60cm) x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead (32 x 6) mm galvanised iron strip by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC 1:2:4 type B-1 in pit, angle iron 25X25X3mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways abd 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, and provision of earth test point including testing on completion complete all as specified and as directed.
Supply and fixing Electrical GDR chequred rubber matting of size 2 mtr X 1 mtr X 25mm thick suitable for HT 11 KV indoor substation as per IS 5424:1969 complete all as specified and as directed. Make:- Joyti / Duratuf Produkt
M&L for Boring horizontally by pneumatic tools across / under the existing road without disturbing the road surface for inserting 50 mm bore GI pipe all complete all as specified and as directed.
Old size sub class ‘B’ brick, laid flat with width equal to the length of brick, for cable protection complete all as specified and directed
Plain cement concrete (1:3:6) type C-2, using 40mm graded crushed stone aggregate as in foundation filling and mass concrete (for foundation bed concrete in stays / poles or any other directed site) complete all as specified and directed.
M&L for Plain cement concrete (1:2:4) type B-1, using 20mm graded crushed stone aggregate for pole/ strut coping, including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for Plain cement concrete (1:4:8) type D-2, using 40mm graded crushed stone aggregate as in foundation filling and mass concrete for pole/strut complete all as specified & directed.
Earth continuity conductor or main earthing lead beyond test point, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation 32x6 mm galvanised iron strip complete all as specified and directed.
Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary , gussets plates, riveting , etc.; n exc 10 Kg each brackets, conforming to Fe-290-Gde E-165 complete all as specified and directed.
Rolled mild steel in plates ( plain or chequered ) channels, square cut or notched ( ordinary and counter sunk) forming holes , without any attachment, conforming to Fe-290-Gde E-165 complete all as specified and directed
M&L for Brick work with old size sub class ‘B’ bricks, straight or curved on plain exc. 6 meter mean radius built in cement mortar (1:4) complete all as specified and directed
Rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surface, finished even and fair complete all as specified and directed.
Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, laying of pipes & cable etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in with ap-proved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated material (soils) to a distance n.exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as specified and directed.
M&L for 80 mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls, poles, under road/floor etc for cable protection, complete all as specified and directed.
M&L for Sand cushioning to U/G cable in layers of 23 cm thick (8 cm before laying the cable and 15 cm thick after laying the cable, punned thickness shall be measured) in trenches complete all as specified and directed. Note: - Only punned thickness shall be measured.
MANGAL ELECTRICAL STORES
KSP ENTERPRISES
George Electricals
UNITED TECHNO PROJECTS PVT LTD
RMK PROJECTS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .