Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable tender | |
| 2 | L2₹22.6 L+₹1.2 L (5.65%)Rejected-Finance | L2 | Rejected-Finance Not being lowest bidder | |
| 3 | L3₹31.2 L+₹9.8 L (45.9%)Rejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Not being lowest bidder | |
| 4 | L4₹33.8 L+₹12.4 L (57.7%)Rejected-Finance | L4 | Rejected-Finance Not being lowest bidder |
Tender Value
₹35.4 L
EMD Value
₹71,000
Closing Date
26 May 2022, 6:00 pmClosed
CWE AF PALAM
CWE (AF) PALAM DELHI CANTT-10
SPECIAL REPAIR TO CERTAIN BLOCKS OF OFFICERS SINGLE LIVING IN ACCOMMODATION AT CAMERO OFFICERS MESS AT SUBROTO PARK
2022_MES_520516_1
CWE/PM/SP-02/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE AF SUBROTO PARK
As per tender documents
9 documents required · 9 mandatory
₹500
GE AF SUBROTO PARK
₹71,000
15 Jul 2022
28 Apr 2022
30 May 2022
28 Apr 2022
26 May 2022
12 May 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for vitrified ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with coloured cement matching with surfaces of tiles as in floor over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed complete all as specified and directed
All as per item No. 2.00 here-in-before but in skirting including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
S&F non skid coloured ceramic tiles area of each tiles exceeding 0.06 sqm but not exceeding 0.11 Sqm and 7mm thick as in floor set & jointed in neat cement slurry & pointed in coloured cement to match over and including 15mm thick screed in cement mortar 1:4 complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 300x450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement 1 :4 and pointed in white or coloured cement to match the shade complete all as specified and directed.
S&F non skid coloured ceramic tiles area of each tiles exceeding 0.11sqm but not exceeding 0.18 Sqm and 7mm thick as in floor set & jointed in neat cement slurry & pointed in coloured cement to match over and including 15mm thick screed in cement mortar 1:4 complete all as specified and directed.
All as per item No. 6.00 here-in-before but as in skirting including 10mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded in any mortar complete all as specified and directed.
S&F in repairs vitreous china wash hand basin white flat back of size 630x450mm including brackets and waste pipe complete all as specified and directed.
S&F in repairs single lever wash basin mixer with popup waste system and 450 mm long braided hoses chromium plated complete all as specified and directed. Make:- ORM-10051 B of Jaquar or its equivalent in Parco/Marc
S&F in in repairs CP waste coupling 32mm size half threaded with 130mm height complete all as specified and directed. Make-ALD-709 of Jaquar or its equivalent in Parco/Marc
S&F in repairs 15 mm bore angle valve chromium plated with wall flange and fancy type with high pressure screwed down with CP flange complete all as specified and directed. Make- ORM- 10053 of Jaquar or its equivalent in Parco/Marc
S&F in repairs PVC bathroom mirror cabinet of size 450x600mm complete all as specified and directed. Make Prayag /nilkamal or its equivalent
S&F in repairs wall mounted EWC with concealed flushing system and cover (colour and size as approved by GE) complete all as specified and directed.
S&F in repairs10 Itr capacity PVC flushing cistern white with inlet ball valve, float and handle including bracket and polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and directed.
S&F in repairs hand shower (health faucet) with 1.0 m long easy flex tube in chrome finish and wall hock complete all as specified and directed. Make-ALD-CHR-565 of Jaquar or its equivalent in Parco/Marc
S&F in repairs CP paper holder complete all as specified and directed. Make-AHS-1553 of Jaquar or its equivalent in Parco/Marc
S&F in repairs jet spray with necessary fixing arrangement complete all as specified and directed.
S&F CP towel ring of approved make complete all as specified and directed.
S&F in repairs bib tap cast copper alloy fancy type chromium plated with crutch or butterfly handle screwed down for 15mm bore pipe complete all as specified and directed.
S&F in repairs CP soap dish of approved make complete all as specified and directed.
S&F corner glass shelf with bracket of approved make complete all as specified and directed.
S&F in repairs 15 mm bore chromium plated shower rose of approved make complete all as specified and directed.
S&F in repairs single lever wall mixer with provision for over head shower with 150x150 mm long bend pipe on shower side, connecting legs and wall fittings etc complete all as specified and directed.
S&F in repairs brass powder coated cloth hanging hooks set of six hooks complete all as specified and directed.
S&F in repairs 15 mm bore two way angle valve chromium plated with wall flange and fancy type high pressure screwed down with CP flange complete all as specified and directed.
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed.
S&F repair CP towel racks with lower hanger complete all as specified and directed.
S&F in repairs PTMT grating round of 100mm dia Minimum wt 50gms) complete all as specified and directed.
S&F in repair PTMT grating with waste hole (Minimum wt 100 gms) complete all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repiar CP connection 15mm size for Hot & Cold water with CP nuts of length 450mm long complete all as specified and directed.
Taking down steel tubing and connections 20mm bore complete all as specified and directed.
All as per item No. 34 here-in-before but 15mm bore complete all as specified and directed.
S&F 20 mm bore tubes, 'medium grade' galvanised, with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed.
All as per item No. 36 here-in-before but 15 mm bore complete all as specified and directed. .
M&L for complete removal of existing treatment of surfaces by steel wire brushing, scraping down smoke spots, moulds, moss and efflorescent salts etc on wall and applying two coats of oil emulsion distemper over a coat of primer including 3mm thick wall care putty on wall complete all as specified and directed.
Taking down cement or cement lime plaster on brick walls incl racking out joints,hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar 1:4 on concrete surfaces of ceiling, finished even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick elastomeric wall care putty on walls complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls, and applying three coats of white wash on walls over a coat of primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls, and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
M&L for preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling complete all as specified and directed.
Taking down chowkats or frames not exc 1.5 Sqm each with shutters(without taking off shutters from the frames) and remove to store complete all as specified and directed.
S&F solid moulded PVC door frame of size 50mmx47mm made out of 5mm prelam PVC sheet made out of 5mm wood grain printed PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet PVC sheet reinforced with M.S. square tube, supplying & fixing in opening as per manufacturer specification complete all as specified and directed.
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet polyurethane painted on the front face & 2mm prelam PVC sheet on back face with wood free EPS. complete all as specified and directed.
S&F in repair aluminium deco grills confirming to DG-104 grade complete all as specified and directed.
S&F in repairs for 18 mm thick celuka PVC ply ends for supporting the hold of shelf / partition/drawers and shall provided 3 edges in size 18mm x 18mm as per required length. The front side of the edge visible in the front of the shelf / partition to be edge lipped by 18mm width x 1mm thick PVC sheet of density 600 kg/ cbm density manufactured by an ISO-9000 certified company, using solvent cement etc. complete all as specified and directed. Make : Rajshree or equivalent in sintex / flexibond
S&F telescopic GI powder coated drawer channel 450mm long with ball bearing complete all as specified and directed.
M&L 50mm dia polished cup board knob fixed in repair with nut, screw and washer of brass complete all as specified and directed.
Demolition of brick or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with subclass B bricks, straight or curved on plan exc 6.00 mtr mean radius, built in cement mortar 1:6 cement mortar complete all as specified and directed.
M&L for brick work with subclass B bricks, staright or curved on plan on plan to any radius in half brick thickness wall, built in cement mortar 1:4 complete all as specified and directed.
Demolition and breaking of 100mm dia drain pipes (salt glazed ware, AC or reinforcement concrete) set in cement mortar complete all as specified and directed.
S&F 110 mm dia bore PVC (SWR) bends, including removing for concrete and refixing with cement concrete 1:2:4, type B1 using 20 mm graded stone aggregate or in 1:3 cement mortar complete all as specified and directed.
S&F PVC (SWR) 110 mm dia bore pipe single socketed, in any length with rubber ring joints fixed to walls, including necessary PVC clamps for fixing of pipes complete all as specified and directed.
Demolition of RCC, of any description and in any position not otherwise specifically provided for (incl reinforcement cut as required to facilities demolition) complete all as specified and directed.
M&L for RCC work in cement concrete 1:2:4 type B1,using 20 mm graded stone aggregate as in chajjas, suspended slab etc, including necessary formwork complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for preparation of old wooden surface of any description over 10 cm in width or girth and applying varnishing over a coat of filler coat of thin varnish to the existing hand rail at staircase and balcony and verandah complete all as specified and directed.
Cutting opening through brick wall built in cement mortar or cement lime mortar for door, window and other opening or enlarging existing openings, converting window into doors openings or cutting out defective brick work for under pinning, including providing fixing and removing shoring, cleaning and stacking bricks removing surplus serviceable bricks, hard core etc to store and rubbish not exec 50m complete all as specified and directed.
S&F in repairs MS powder coated in teakwood finish curtain rods (drapery) 25 mm dia, including set of brackets, channels etc complete all as specified and directed.
M&L for cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate as in roof kerbs or mud stops rounded or chamfered on edges, lintels upto 1.5 m clear span cills steps seismic and other similar bands plinth courses string courses lacing courses parapets and railing upto 60 cm in height coping kneelers apex stones bed plates kerbs, water troughs and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and directed.
S&F 100 mm size butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type C-21 complete all as specified and as directed.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150 mm long aluminium handles cast type anodised complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C2 as in plinth protection using 40 mm graded stone aggregate including making joints and filling with sand bitumen mastic complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n.exc. 15 cm thickness ( below or above ground level) complete all as specified and directed.
M&L for coloured granite slab, 20 + 2 mm thick, as in Platforms of kitchen and similar work etc., bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite ston including Chamfering/rounding the edges complete all as specified and as directed (colour & design approved by GE) over 15mm thick screed bad in CM 1:4 Complete
M&L for coloured granite, 12 to 15 mm thick, as in vertical surface of kitchen platforms & similar work etc., bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including Chamfering/Rounding the edges complete all as specified and as directed (colour & design approved by GE) over 15 mm thick rendering in CM 1:4 complete
Taking down carefully copper/aluminium point wiring light, fan, light fittings, socket or power complete, such as switches, ceiling roses, pendent’s regulators, sockets etc. removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditioned separately and making good disturbed surface of walls, floors etc complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with two runs of single core FRLS PVC insulated unsheathed IS-694 marked 100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20 mm including conduit fittings and accessories concealed in wall / ceiling including provn of pressed steel terminal box of 2 mm thick and covered with 3 mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with provn of earth wire of PVC insulated, unsheathed, 1100 V grade able multi stranded FRLS IS-694 marked copper conductor of size 1.5 sqmm connected to earth doily complete all as specified and directed by Engr-in-Charge. For one light point controlled by one SP switch.
All as per ser item No 77 above but for socket outlet 5 Amp controlled by one switch on the same board with other switches complete all as specified and directed by Engr-in-Charge.
All as per ser item No 77 here-in-before but for 3 pin 5 Amps socket outlet controlled by one switch on the independent board with other switches complete all as specified and directed.
All as per ser item No 77 here-in-before but for one light point controlled by two Nos two way switches complete all as specified and directed.
All as per item No 77 here-in-before but with 2.5 Sqmm cable for Independent board one 3 pin 15 Amps socket outlet including single core 2.5 Sqmm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire connected to gang box of required size complete all as specified and directed.
M&L for disconnecting and taking out unserviceable switch board/ sunken box and laminated sheet and keeping the existing point wiring safe and providing following items with accessories including connecting the same with existing wiring, testing complete all specified as directed.
Pressed terminal steel flush box 2 mm thick of size 8"x11"
Pressed terminal steel flush box 2 mm thick of size 7"x9"
Pressed terminal steel flush box 2 mm thick of size 5"x7"
Pressed terminal steel flush box 2 mm thick of size 5"x5"
S&F with cutting of laminated Hylam sheet cover 3 mm thick for mounting of switches and sockets as per site requirement of size 8"x11" with screws
S&F with cutting of laminated Hylam sheet cover 3 mm thick for mounting of switches and sockets as per site requirement of size 7"x9" with screws
S&F with cutting of laminated Hylam sheet cover 3 mm thick for mounting of switches and sockets as per site requirement of size 5"x7" with screws
S&F with cutting of laminated Hylam sheet cover 3 mm thick for mounting of switches and sockets as per site requirement of size 5"x5" with screws
All as per item No 77 here-in-before but with 4 Sqmm cable for Independent board one 3 pin 15 Amps socket outlet including single core 4 Sqmm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to metal clad box of required size complete all as specified and directed.
S&F in replacement of metal clad socket single pole and neutral sheet metal enclosure with and 20A earth plug and socket compete with one single pole MCB 20A 240 Volts complete all as specified and directed Make : L&T/legrand/Havells.
S&F switch piano 5 Amps flush type single pole one way suitable for 240 volt AC complete all as specified and directed. Make:-Cona/Polycab/Havells
S&F socket outlet flush type 5 pin 6 Amps suitable for 240 volt ACc complete all as specified and directed.Make:-Cona/Polycab/Havells
S&F socket outlet 2 in 1, 5 pin 16 Amps flush type suitable for 240 volt AC complete all as specified and directed. Make:-Cona/Polycab/Havells
S&F switch piano 15 Amps flush type single pole one way suitable for 240 volt AC complete all as specified and directed.Make:-Cona/Polycab/Havells
S&F ceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/polycarbonate, isolated body fixed on PVC round block complete all as specified and directed. Make:-Cona/Polycab/Havells
S&F electronic fan regulator rotary flush step type 120 watt, 240 volt complete all as specified and directed. Make:-Cona/Polycab/Havells
S&F switch piano 5 Amps flush type single pole two way suitable for 240 volt AC complete all as specified and directed. Make:-Cona/Polycab/Havells
Supply and fix bell push flush type 5 Amps suitable for 240 volt complete all as specified and directed. Make:-Cona/Polycab/Havells
S&F bell AC 240 volt ding dong type complete all as specified and directed. Make:-Cona/Polycab/Havells
S&F wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver,20 watt LED fitting, 4000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed. Make:-Havellls Cat No- LUMILINEPLUSBS20WLED865SPCSS or equivalent in C&S/ Polycab
S&F LED wall mounted light with decorative wall bracket luminaire suitable for 20 W including providing flexible copper wire, twin core cable complete all as specified and directed. Make:-Halonix Cat No- HH08CF RF 02 or equivalent in C&S/ Polycab
S&F wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed. Make:-Havells Cat No- LUMILINEPLUSBS10WLED865SPCSS or equivalent in C&S/ Polycab
S&F LED security light fitting 45 watt high pressure dia cast aluminium housing and secondary optical lens for superior light distribution , heat resistant toughened glass with frame, IP66 protection complete with lamp & connected item and connection with suitable cable from ceiling rose to light fitting and fixing on GI bracket made out of suitable GI Pipe medium grade 1.2 mtr long bent to shape and fixed on wall with flat iron clamps, nuts bolts washer etc complete all as specified and directed
Taking down including disconnecting the electric connection of ceiling/exhaust fan and dismantling blades, greasing and painting the whole assembly including marking MES No complete all as specified and directed
Hanging / fixing only ceiling/exhaust fan received from item No-102 above and connecting up including fastener and provision of suitable size of copper cable from connector of fans to ceiling rose and other new nut, bolts, washer etc if required for fixing complete all as specified and directed.
M&L for in replacement submain wiring with two run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and directed. Note:- - 2 Runs of 6.0 Sqmm single core and one run of 6.0 sqmm single core cable shall be measured as 01 RM.
M&L for in replacement submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and directed. Note:- - 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable shall be measured as 01 RM.
Taking down unserviceable submain wiring of aluminium two runs of any size cable including batten/conduit complete etc and making good disturb surfaces complete all as specified and directed.
S&F in replacement load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable for TP/FP 'A' frame MCCB of 100 Amps =01 No MCB for outgoing complete all as specified and as directed. Note :- MCB shall be measured and paid for seperately.
S&F in replacement MCB distribution board with bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type real gray horizontal type complete all as specified and directed Make - Havells or Standard/indoasian/ Legrand Note :- MCB shall be measured and paid for seperately.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvanized iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate and RCC cover complete all as shown in electrical plate No 3 of MES schedule Pt I of 2009 and directed . Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
M&L in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed.
S&F in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 16 KA complete all as specified and directed.
Fabrication,supply, install and commissioning cubicle type, meter box, indoor type, totally enclosed,dust & vermin proof (protection class IP43) made out of MS angle iron frame work, MS flat iron and CRCA sheet of 2.0 mm thick as per IS5039 duly painted with powder coated paint of approved shade. The meter box shall be suitable for accommodating 08 Nos single phase LT electric energy meter in independent cubicles with fiber glass of suitable size fixed on front side of the cubicles to view the meter readings. The panel shall be suitable to be mounted on wall with suitable fixing arrangement. Each cubicle shall have openings for entry and exit of cables and locking arrangements. Refixing of existing meter complete all as specified and directed.
Taking down the defective cubicle type, meter box ,indoor type with all connections and keeping in safe custody for giving credit to the contractor complete all as specified.
Taking down unserviceable SP/SPN MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply,complete all as specified and directed.
S&F MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' series complete all as specified and directed.Make:- Havells/indoasian/ Legrand
Fixing only MCB SP of any size recieved from Sr item No 114 complete all as specified and directed.
S&F MCB SPN 32 Amps 10 KA, 240 volt 50 HZ 'C' series complete all as specified and directed.Make:- Havells/indoasian/ Legrand
Fixing only MCB SPN 32/40 Amps 10 KA, 240 volt 50 HZ received from Sr item No 114 complete all as specified and directed.
M&L for taking down existing geyser carefully without damaging of any capacity from bathroom and to be kept in safe custody until completion of finishing work and re-fixing the same after completion of finishing work including cleaning the geyser and marking MES No., connecting, testing complete all as specified and as directed.
Mahesh Enterprises
shiva enterprises
Tsmalik
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .