Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.9 LAdmitted-Finance | ₹43.9 L | L1 | Admitted-Finance |
| 2 | L2₹46.1 LAdmitted-Finance | ₹46.1 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | P NAIDU L1 | KBR CONSTRUCTIONS L2 |
|---|---|---|---|---|---|
| 1.00NOTE: 1. The bidders/ contractors are advised to read tender documentts and all corrigendum/ amendments and General conditions of contracts before entry/ quoting the rates. | |||||
| 2.00 | Demolition of PCC of any description and in any position not otherwise specifically provided for(un-reinforcement ) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed. | 8 | Cum | 2,000 ₹16,000 | 2,000 ₹16,000 |
| 3.00 | Demolition of RCC of any description and in any position not otherwise specifically provided reinforced (reinforcement of cut as required to facilasite demolition etc) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed. | 7 | Cum | 3,500 ₹24,500 | 2,300 ₹16,100 |
| 4.00 | Dismantling of CGI/PGI sheet roofing any gauge and any thickness including ridge, valley gutter etc complete all as specified and as directed. | 42 | Sqm | 90 ₹3,780 | 95 ₹3,990 |
| 5.00 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets or frame work. | 36 | Sqm | 85 ₹3,060 | 120 ₹4,320 |
| 6.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and and as directed | 5.5 | Qtl | 650 ₹3,575 | 850 ₹4,675 |
| 7.00 | Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including disposal of the rubbish out off the premises complete all as specified and as directed. | 4 | Cum | 1,800 ₹7,200 | 2,200 ₹8,800 |
| 8.00 | Taking down chowkats or frames with shutters (without taking off shutters from frames) of size not exceeding 1.5 SQMs each complete all as specified and as directed | 1 | Each | 500 ₹500 | 275 ₹275 |
| 9.00 | Taking down chowkats or frames with shutters (without taking off shutters from frames) of size exceeding 1.5 sqm and not exc 4.00 sqm each complete all as specified and as directed | 5 | Each | 500 ₹2,500 | 275 ₹1,375 |
| 10.00 | S&F standard aluminum sections of any Type as in doors, windows, ventilators, partitons etc, powder coated, cut to size, jointed with cadmium plated steel screws, including necessary jointing clips, rubber packing, neoprene rubber gasket, aluminium snap beading, screws, aluminium fittings, handles, locking arrangement (star lock), Nylon ball bearings and Unit rate quoted shall be deemed to include for sealing the gap of frame with Jamb and Cill (alround) using silicon gel at the rate of 0.05 lit/m for both faces of window etc complete all as specified and as directed
Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment. Cost of other consumables required for the item shall be deemed to be included in the quoted rate. However glass panes / Bakelite sheet only will be measured and paid separately under respective items as supply only. Fixing by element of these items shall be deemed to be included in quoted rate. | 120 | Kg | 1,650 ₹2.0 L | 1,800 ₹2.2 L |
Updated dates
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
1 Apr 2026, 6:00 pmClosed
Maj Saurabh Singh
Garrison Engineer(P) North, Minniebay, Junglighat Post, Port Blair, Andaman
Addition/Alteration and Improvement to Building No P-03 and P-04 at main gate entrance OTM complex, Vijaya Nagar, ICGS Hut Bay
2025_MES_745332_2
8187Addition/Alteration and Improvement to Building No P-03 and P-04 at main gate entrance OTM compl
Open Tender
Civil Works
180 days
HUT BAY
As per NIT
8 documents required · 8 mandatory
₹500
₹87,000
Yes
18 Apr 2026
6 Mar 2026
8 Apr 2026
6 Mar 2026
1 Apr 2026
13 Mar 2026
9 Mar 2026 - 11 Mar 2026
NOTE: 1. The bidders/ contractors are advised to read tender documentts and all corrigendum/ amendments and General conditions of contracts before entry/ quoting the rates.
Demolition of PCC of any description and in any position not otherwise specifically provided for(un-reinforcement ) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided reinforced (reinforcement of cut as required to facilasite demolition etc) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
Dismantling of CGI/PGI sheet roofing any gauge and any thickness including ridge, valley gutter etc complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets or frame work.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and and as directed
Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including disposal of the rubbish out off the premises complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) of size not exceeding 1.5 SQMs each complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutters from frames) of size exceeding 1.5 sqm and not exc 4.00 sqm each complete all as specified and as directed
S&F 4.8 mm thick sheet glass, ordinary quality, in each pane for n exc 0.50 Sqm each pane for aluminium sliding windows/ventilator shutters etc complete all as specified and directed.
S&F 4.8 mm thick sheet glass, ordinary quality, in each pane for exc 0.50 Sqm each pane for aluminium sliding windows / ventilator shutters etc complete all as specified and directed.
S&F stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
S&F for 12mm thick Veneered decorative plywood,grade I (with BWR resin) decorative both side faces etc complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding removing serviceable tiles and rubbish off the premises etcand removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including for providing of screed bed or bedding layer of cement mortar 20mm thick for laying floor finish in CM 1:6 complete all as specified and as directed
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in skirting / dado etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match etc and including for providing rendering 10mm thick on brick/concrete surface in CM 1:4 to receive tiles in skirting/dados complete all as specified and as directed
Excavating over areas, n exc 1.5 m deep and getting out of soft soil complete all as specified and directed.
Excavating over areas, exc 1.5 m deep and n.exc 3m deep and getting out of soft soil complete all as specified and directed.
M&L for providing cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) in fdn filling and mass concrete
M&L for use and waste of steel Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter.
M&L RCC M-30 design mix using 20mm graded aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soils
M&L for Formwork to sides of Column square or rectangular in plan for rough finished surface of concrete and the like upto a height of 6.00m from ground level complete all as specified and directed
M&L RCC M-30 design mix using 20mm graded aggregate columns upto a height of 6.00m from ground level complete all as specified and directed
M&L for use and waste of steel Formwork to sides and soffits of , lintels beam , Tie beam shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc and the like upto a height of 7.00m from ground level complete all as specified and directed
M&L RCC M-30 design mix using 20mm graded aggregate in beams, cantilevers, bressummers, lintels over 1.5m span upto a height of 7.00m from ground level complete all as specified and directed
M&L form work for fair finished surfaces of concrete to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) and the like upto a height of 7.00m from ground level complete all as specified and directed
M&L RCC M-30 design mix using 20mm graded aggregate as in slabs supported on walls, beams and columns in floor, roofs, landings, balconies, canopies, deck slabs and in shelves and the like upto a height of 7.00m from ground level complete all as specified and directed
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, ending spirally for hoopingfor columns, hookingends and bindingwith and includingmild steel ire(annealed) not lessthan 0.9mm dia or securing with clips and the like upto a height of 7.00m from ground level complete all as specified and directed
All as per item no 31.00 above but 5mm dia and over upto and including 10mm dia n stirrups, spacers and binders
M&L for Pre-cast cement concrete block masonry Type C1 (1:3:6) 20mm aggregate with solid blocks, exc. 10 cm in width and setting in mortar (1:6), complete
Taking down cement plaster of any description and thickness on brick walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement.
M & L for rendering 5 mm thick in cement plaster 1:3 on concrete surfaces of ceiling finished even and smooth without using extra cement all as specified and as specified.
M&L for decorative Mangalore tiles, white house roof design style of red colour of any size as directed by GE fixed with necessary adhesive and bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:3 etc: complete all as specified and directed.
M&L for decorative Mangalore ridge tiles,white house roof design style of red colour of any size as direted by GE, fixed with necessary adhesive complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed.
M & L for preparing newly plasterd wall/Ceiling surfaces of walls and applying two coats of distemper oil emulsion over 1 mm thick wall care putty and a coat of primer on plastered and other surfaces with alkali resistant priming paint etc complete all as specified and as directed.
Material and labour for preparation of newly plastered wall surfaces and applying three coats of white wash on celings complete all as specified and as directed
S&F in repair Rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
S&F in Repairs 20mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
S& F in repairs 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches, wall incl bends etc fittings complete and including taking down of existing damaged steel pipe of 20 mm dia complete all as specifiedetc completed all as Engineer-in-Charge
S&F in repairs for Framed work as in doors or gates of angle or other section of grade Fe 290 Gde E-165 with gusset plates, rails, braces, MS rollers any dia, pintel nut, bolts etc complete, drilled for fixing of steel sheeting or other covering Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as directed.
S&F for Decorative Knobs for fixing of gates etc complete all as specified and directed.
S&F Mild steel plates, plain or chequered in required sizes thickness of grade Fe-290 (Grade E-165) as in steel sheeting over steel gate where required, complete all as specified and directed
Preparation of new steel & iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint, quality, colour on these surfaces over a coat of red oxide, complete all as specified
M&L Hard core of broken stone or boulders of gauge not exceeding 63mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rolling with power roller exc. 8 tonne & n.exc. 12 tonne to a true surface complete all as specified and directed.
M & L for cement concrete 75mm thick 1:4:8 (40mm graded aggregate) type D2. as in sub base all as specified and directed by Engr-in-Charge
Spreading and levelling of Sand/ grit cushioning below interlocking tiles.
M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment (glossy finish) any shape & size conforming to IS 15658-2006 of 80 mm thickness, M-40 grade etc complete all as specified and as directed.
M&L for pre cast Machine pressed cement concrete 1:2:4 type B-0 (using 12.50mm graded stone aggregate) as in kerbs stones and fixing all as per manufacturer instructions etc size shall be decided and directed by GE
M&L for Moorum filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc complete all as pecified and directed by Engr-in-Charge.
M&L for Reinforced concrete pipes of bore 450mm, class NP2, laid and jointed omplete with collars complte all as specified.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, includingfixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Taking down unserviceable sub main wiring of any type, any size, making good to the disturbed surfaces by matching with the adjoining surfaces.
Dismantling Concrete Poles of any size and refixing prestressed concrete pole of 9 mtr long inclduing Excavation and foundation complete all as directed.
Dismantling HDGI Octagonal Pole of any size and refixing HDGI octagonal pole of 7 mtr long including Excavation and foundation complete all as directed.
Material and labour for Point wiring complete with 1100 volts grade, 1.5 Sqmm (nominal area), single core, PVC insulated, unsheathed, multi-stranded copper conductor cable FRLS drawn through and including medium grade, rigid, nonmetallic PVC conduit of suitable size not less than 20mm dia, with all necessary fittings, concealed in wall/ roof /floor duly earthed with one run of single core cable of same discription but green in colour as continuous earthing wire connected to common earth dolly including 1.6mm thick fabricated MS sheet terminal box, flush mounting in the wall for mounting switchs/ switche socket combination/ fan regulators etc., covered with 3mm thick plastic laminated sheet complete all as specified for the following :- (a) One light point controlled by one Switch
(b) All as per item No 62.00 above but for One Ceiling/Exhaust Fan controlled by One Switch
(c) All as per item No 62.00 here-in-before but forOne 5A 2pin/3pin switch socket out let multipurpose on Same Board.
(d) All as per item No 62.00 here-in-before but for One 5A 2pin/3pin switch socket out let multipurpose on Independent board
Supply and fix on modular switch 1 way 6A, 1 module all as specified
Supply and fix Modular socket 6A 2/3 pin, combined 2 module all as specified
S&F Ceiling rose, PVC/ polycarbonate, isolated body with three terminals, ISI marked all as directed.
Supply and fix steel sheet factory made double door, powder coated MCB DB with bus bar 200 Amps, Neutral link, earth bar, double door type SPN 8 way, 220 volts MCB as incomer complete all s specified and as directed.
Supply and fixing LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing ceiling fans complete with three blades, Suitable down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB), SPN, 32 A, capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB), SP, 6-32 A, capacity in the MCB DB complete with connection testing and commissioning.
Supply & lay cable XLPE insulated screened PVC bedded, galvanised steel strip armoured shethed, LT 1100 all as specified, volts grade with multistranded aluminium conductor of size 10 sqmm 2 core.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil all as specified and directed.
M&L for providing coarse sand as in cushioning for underground cable protection including punning down gently in layers complete all as specified and as directed Note: Only punned thickness shall be considered for measurement and payment purpose
Supplying and laying un-reinforced precast concrete cable cover,Class LV, Type I, flat, size250mm x 150mm x 40mm complete all as specified and as directed
Material and labour for sub main wiring with two runs of single core FRLS PVC insulated, multistranded unsheathed copper conductor cable of size 4 square mm and drawing through casing and capping of suitable size with accessories along with one run of 4 square mm PVC insulated unsheathed multi stranded 1100 volts grade with copper conductor cable as earth continuity conductor connected to earth and earth dolly, connecting to main board duly making good the disturbed wall surfaces to match with the surroundings complete all as specified and directed. Note: 3 runs of 4 sqmm cableand 1 run of PVC casing and capping of suitable size with accessories shall be measured as 1 unit .
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_846019.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
NIT8187.pdf
Additional Documents • 0.32 MB
Tenderdoc8187.pdf
Tender Documents • 1.49 MB
BOQ_846019.xls
BOQ • 1.23 MB
Download all tender documents and submit your bid