| 1 | L1₹13.4 LAccepted-AOC MANEGAON CHAMPANAGAR KHAMARIA JABALPUR 482005 MP | JABALPUR | JABALPUR | MP | 482005 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹16.1 L+₹2.2 L (15.7%)Rejected-Finance 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | L2 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
26 Sept 2020, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIR/MAINTENANCE AND REPLACEMENT OF OIL FIRE INCINERATOR, LAUNDRY PLANT AND FIRE FIGHTING SYSTEM AT MH AND CONNECTED CERTAIN WORKS UNDER GE (WEST) JABALPUR
2020_MES_373184_1
8232/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹40,000
13 Oct 2020
29 Aug 2020
29 Sept 2020
29 Aug 2020
26 Sept 2020
12 Sept 2020
30 Aug 2020 - 10 Sept 2020
Amount
Comprehensive maintenance in situ of Oil fired Incinerator of Heaton make capacity 60kg/hr from his position for repair/overhauling and rectify all the defect and Refixing the same after testing and connection complete all as specified and directed. Note :- UNSV parts shall be measured and paid seperately under relevenat items:- (a) Monthly testing of all the parts of incinerator (b) Cleaning & oilling of the parts to make smooth for running (c) Testing of all the parts of the incinertor & removing rust and running idle for 45 min once in a month to overcome all the minor defects (d) Cleaning of all blockage as and when required at site (e) Cleaning & washing of chamber as directed by Engineer-in-charge
Supply only Electrodes suitable for B-30 and B-12 Heaton make oil fired incinerator of capacity 60kg/hr.
Supply only ignition Transformer of Heaton make oil fired incinerator of capacity 60kg/hr .
Supply only sequencial controller of Heaton make oil fired incinerator of capacity 60 kg/hr .
Supply only HT cable of Heaton make oil fired incinerator of capacity 60kg/hr .
Supply only solenoide valve of Heaton make oil fired incinerator of capacity 60kg/hr.
Supply only nozzels of Heaton make oil fired incinerator of capacity 60kg/hr .
Supply only temperature indicating controllers, voltmeter, thermocouples, contractors and over load relays suitable for Heaton make oil fired incinerator of capacity 60kg/hr .
M&L painting of Heaton make oil fire incinerator of capacity 60kg/hr with two coat of aluminium paint over a coat of red oxide primer of approved make of chimeny, circulatioon tank, cyclone seperator, recirculation water tank, ventury scrubber, ID fan amd ducting etc complete all as specified and directed. Note : Height of Chimney approx 30 Mtrs from the ground level.
Comprehensive quartely maint and repair & testing to fire detection and fire alarm system installed at MH Ph- I, II and III at Jabalpur. Note : Quoted Rate shall be deemed inclusive of following :- (a) Monthly checking of main control panel and local control panel suitable for floor/wall mounting fabricated from 16 SWG CRCA sheet incorporating audio/visual indication for each zone mains operated with 24 volts, maintenance free battery of 42 AH capacity and battery charger complete with public address system and Replacement of Old/ UNSV defective parts if reqd. (b) Monthly checking of Ionization type smoke detector series of 65 photo electric smoke detector response indicator internal and external, electric hooter zone wise, manual call point push button leakage of steel pipe of any size, CI non return valve installation valve, fire pump with motor, pressure switch, pressure gauge, air vessel cylinder type HDQB sprinklers of 15 mm size temp rating 68 dgree centigrade with 5 mm standerd response bulb nickle chrome finish 1/2" Note :- UNSV parts shall be measured and paid seperately under relevenat items.
Carrying out testing of Fire fightining sys of Phase I, II & III & test certificate from concerened Testing lab of fire fighting in every quaterly in presence of Rep from MH/MH QM & Engineer in charge/JE
Supply only Pressure gauge 100 mm complete including Replacement of Old/ UNSV old unsv pressure gauge all as specified and directed
Supply only butter fly valve 80 mm complete including Replacement of Old/ UNSV old unsv butter fly valve all as specified and directed
Supply only butter fly valve 100 mm complete including Replacement of Old/ UNSV old unsv butter fly valve all as specified and directed
Supply only butter fly valve 150 mm complete including Replacement of Old/ UNSV old unsv butter fly valve all as specified and directed
Supply only butter fly valve 200 mm complete including Replacement of Old/ UNSV old unsv butter fly valve all as specified and directed
Supply only non return valve 80 mm complete including Replacement of Old/ UNSV old unsv non return valve all as specified and directed
Supply only non return valve 100 mm complete including Replacement of Old/ UNSV old unsv non return valve all as specified and directed
Supply only non return valve 150 mm complete including Replacement of Old/ UNSV old unsv non return valve all as specified and directed
Supply only photo electric type smoke detector including replacement of old unsv complete all as specified and directed. Make- System sensor/Agni/Apollo 65
Repair / Replacement of Old/ UNSV GI pipe 25 mm heavy grade including all fittings complete all as sepcified and directd.
Repair / Replacement of Old/ UNSV sprinkler complete all as sepcified and directed.
Repair / Replacement of Old/ UNSV CPU Card in Main panel in Phase -III complete all as specified and directed. Make - Spensor or directed by Engr in -charge
Repair / Replacement of Old/ UNSV Power Card in Main panel in Phase-III complete all as specified and directed. Make - Spensor or directed by Engr-in-charge
Repair / Replacement of Old/ UNSV Manual call point 24 Volt DC type in fire alarm in Phase-III complete all as specified and directed. Make -Spensor or directed by Engr-in-charge
Repair / Replacement of Old/ UNSV Hooter (Card Type) in fire alarm in Phase-III at MH complete all as specified and directed. Make- Spensor or directed by Engr-in-charge
Repair / Replacement of Old/ UNSV Response Indicator LED type in fire alarm in Phase-III at MH complete all as specified and directed. Make - Spensor or directed by Engr-in-charge
Repair / Replacement of Old/ UNSV Hooter (L&T Transformer type) in fire alarm in Phase-II at MH of complete all as specified and directed. Make - Agni or directed by Engr-in-charge
Repair / Replacement of Old/ UNSV Power card in fire alarm in Phase-II at MH of complete all as specified and directed. Make - Agni or equivalent as directed by Engr in charge
Repair / Replacement of Old/ UNSV Control card in fire alarm in Phase-II at MH of complete all as specified and directed. Make - Agni or equivalent as directed by Engr in charge
Repair / Replacement of Old/ UNSV Zone card in fire alarm in Phase-II at MH of complete all as specified and directed. Make - Agni
Repair / Replacement of Old/ UNSV Response indicator with MS box in fire alarm in Phase-II at MH of complete all as specified and directed. Make - Agni or equivalent as directed by Engr in charge
Repair / Replacement of Old/ UNSV Manual call point in fire alarm in Phase-II & III at MH of complete all as specified and directed. Make - Agni or equivalent as directed by Engr in charge
Comprehensive periodic maintenance, repair & servicing of Washer Extractor SWE series Electrically heated 415 volts, 50 Hz, 3 Phase 35 Kg Capacity Make : Supershine Laundry systems Model - SWE/ 30/ E/ Ser No 2015 and 2016. (Total unit - 02 no.) Note : - UNSV parts shall be measured and paid seperately under relevenat items.
Repair/ Replacement of Automatic Door lock assembly suitable for washer Extractor as per Existing model Model - SWE/ 30/ E/ Ser No 2015
Repair/ Replacement of Shock absorber Oil filled of Suitable for washer Extractor Existing Model Model - SWE/ 30/ E/ Ser No 2015
Repair/ Replacement of Heating Element 3 KW capacity, 3 Phase, 50 Hz, 415 Volts suitable for washer Extracor as per Existing Model - SWE/ 30/ E/ Ser No 2015
Supply only of V Belt Model No. B 2532 LD/ B 98 suitable for Washer Extractor as per Existing model Model - SWE/ 30/ E/ Ser No 2015
Repair/ Replacement of Old/ Unsv Ball Bearing assembly in Drum including taking down of drum and refixing with necessary connected items through super shine laundary systems suitable for washer Extracor as per Existing Model - SWE/ 30/ E/ Ser No 2015.
Repair/ Rewinding of Electric Motor 5 KW, 3 Phase, 415 Volts, 50 Hz, Rpm 1450 complete all as specified and as directed by Engr-In-Charge.
Comprehensive periodic maintenance, repair & servicing of Washer Extractor SWE series Electrically heated 415 volts, 50 Hz, 3 Phase 60 Kg Capacity Make : Supershine Laundry systems Model - SWE/ 60/ E/ Ser No 2017 and 2018 and 2019. (Total unit - 03 no. ) Note :- UNSV parts shall be measured and paid seperately under relevenat items.
Repair/ Replacement of Automatic Door lock assembly suitable for washer Extractor as per Existing model Model - SWE/ 60/ E/ Ser No 2017, 2018 and 2019.
Repair/ Replacement of Shock absorber Oil filled of Suitable for washer Extractor Existing Model Model - SWE/ 60/ E/ Ser No 2017,2018 and 2019.
Repair/ Replacement of Heating Element 3 KW capacity, 3 Phase, 50 Hz, 415 Volts suitable for washer Extracor as per Existing Model - SWE/ 60/ E/ Ser No 2017,2018 and 2019.
Supply only of V Belt Model No. B 3242 LP/ B 126 suitable for Washer Extractor as per Existing model Model - SWE/ 60/ E/ Ser No 2017,2019 and 2019.
Repair/ Replacement of Ball Bearing assembly in Drum including taking down of drum and refixing with necessary connected items through super shine laundary systems suitable for washer Extracor as per Existing Model - SWE/ 60/ E/ Ser No 2017 and 2018 and 2019.
Repair/ Replacement of Controller Relay System Box Yaskava-V-1000 Model -CIMR-VT4A0031FAA, Max apply motor 15/11 KW, AC 3 Phase Input 38/29 Amp, Output 31/24 Amp, Type-1 enclosure suitable for washer Extracor as per Existing Model - SWE/ 60/ E/ Ser No 2017, 2018 and 2019.
Repair/ Rewinding of Electric Motor 10 KW, 3 Phase, 415 Volts, 50 Hz, Rpm 1450 complete all as specified and as directed by Engr-In-Charge.
Comprehensive periodic maintenance, repair & servicing of Drying Tumbler Capacity 60 Kg SWE series Electrically heated 415 volts, 50 Hz, 3 Phase Make : Supershine Laundry systems Model - SDT/60 / S. (Total unit - 02 no.) Note :- UNSV parts shall be measured and paid seperately under relevenat items.
Repair/ Rewinding of Prime mover capacity 1.5 KW/ 2 Hp motor, 1410 Rpm, 3 Phase, squirell cage induction motor suitable for Drying Tumbler 60 Kg Capacity as per Existing model Model - SDT/ 60/ S
Repair/ Replacement of Automatic Door lock assembly suitable for washer Extractor as per Existing model Model - SDT/ 60/ S.
Repair/ Replacement of Shock absorber Oil filled of Suitable for washer Extractor Existing Model Model - SDT/ 60/ S.
Repair/ Replacement of Heating Element 3 Kw capacity, 3 Phase, 50 Hz, 415 Volts suitable for washer Extracor as per Existing Model - SDT/ 60/ S.
Supply only of V Belt Model No. B 2227 LB-86 suitable for Drying Tumbler as per Existing model Model - SDT/ 60/ S.
Supply only of Ball Valve 25 mm suitable for Washer Extractor as per Existing model Model - SDT/60/s
Supply only of MCB 100 Amp 'C' type, 4 pole, 415 Volts, 50 Hz suitable for Drying tumbler 60 Kg capacity as per Existing model Model - SDT/ 60/ S.
Repair/ Replacement of Ball Bearing assembly in Drum including taking down of drum and refixing with necessary connected items through super shine laundary systems suitable for Drying tumbler as per Existing Model - SDT/60/S.
Repair/ Replacement of Controller Relay System Box Yaskava-V-1000 Model -CIMR-VT4A0018FAA, Max apply motor 7.5/5.5 KW, AC 3 Phase Input 380-480 Volt, 20-15 Amp, Output 480-400 Volt- 17.5/15.5 Amp, Type-1 enclosure suitable for washer Extracor as per Existing Model - SDT/60/S
Comprehensive periodic maintenance, repair & servicing of Flat work rotary drying ironer SFW/20/E series Electrically heated 415 volts, 50 Hz, 3 Phase Make : Supershine Laundry systems Model - SFW/20 / E. Ser No 2022 01 Roll. Note :- UNSV parts shall be measured and paid seperately under relevenat items. (a) Testing of all the parts of Flat work drying ironer (b) Free run of the machine & checking the temp at different time interval (c) Removing blockage from the pipe occur & make the iron surface well polished (d) Repair of the iron stand for keeping drying ironer (e) Carrying out the overhauling of the parts & greasing
Comprehensive periodic maintenance, repair & servicing of Flat Bed press Pneumatically operated with front push button SFB series Electrically heated 415 volts, 50 Hz, 3 Phase Make : Supershine Laundry systems Model - SFB/30 / E. Ser No 2023 and 2024. (Total unit - 02 no.) (a) Making the flat bed surface even & remove any obstruction & wear tear in the flat bed surface (b) Reparing the stand so that it can take load of the structure c) Carrying out the overhauling of the parts and make them greasing & oiling remove anty rust on it. (d) Testing of all the parts of Flat bed press Note :- UNSV parts shall be measured and paid seperately under relevenat items.
Comprehensive periodic maintenance, repair & servicing of Dry Cleaning machine, High spin, soft mount, Multi solvent SDC/35 series Capacity 35 KG Electrically heated, 415 volts, 50 Hz, 3 Phase. Make : Supershine Laundry systems Model - SDC/ 35 Ser No 2025 and 2026. (Total unit -02 no.) Note :- UNSV parts shall be measured and paid seperately under relevenat items.:- (a) Testing of all the parts of Dry cleaning machine & making them rust free by applying greasing and oiling (b) Checking the dry cleaning machine for any storage of water inside the machine and removing them by using heating blower to make it dry. (c) Checking of any loose wire and fix them with the insulating tape and make it perfectly insulated.
Repair/ Rewinding of Prime mover capacity 0.75 KW/ 01 HP Squirrel Cage induction motor, 3 Phase, 2830 Rpm, suitable for Flat work rotary drying ironer as per Existing model Model - SFW/ 20/ E
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, 200 Amps with breaking capacity 25 KA, complete all as specified
Supply and Fixing XLPE insulated heavy duty electric cables with aluminium conductor, 1100 Volts Grade LT cable in trenches/ floor / pole etc and duly connection with existing MCCB / main switch / transformer / panel . Notes - (a) Lugs are deemed to be included in the rate quoted for laying of cable and to be used properly wherever required while connecting cables to the panel board.
(a) 10 sqmm 4 core
(b) 16 sqmm 4 core
Cleaning of fire fighting water storage sump which is underground and close to motor op room and having a depth of around 6 mtr deep and removing mud upto distance of 25 mtr from the site so that it can run on DG set also & carry out fire testing practice and rehersal at every qtr in presence of MH staff or directed by Engr in Charge.
S & F in repair of foot valve of fire fighting water storage tank for pipe of 100 mm dia
S & F in repair of foot valve of fire fighting water storage tank for pipe of 150 mm dia
S & F in repair of foot valve of fire fighting water storage tank for pipe of 200 mm dia
S&F & hositing and fixing in position and connecting in repair 5000 ltr capacity tank rotational moulded polythelene water storage tank inculding fixing arrangment for inlet/outlet/overflow and vent size of standard size and all complete as directed by Enginner-in -charge. MAKE - Sintex
Material & Labour for painting of fire fighting pipeline & panel with one coat of synthetic enamel paint of approved/Red colour or shade as approved by Engineer-in-Charge including preparation of surface after removing existing paint & filling depressions complete all as specified & directed by Engineer - in-Charge
M K ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .