| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹58.6 L+₹57,564 (0.99%)Rejected-AOC | L2 | Rejected-AOC Second Lowest Tenderer | |
| 3 | L3₹59.5 L+₹1.5 L (2.57%)Rejected-AOC | L3 | Rejected-AOC Third Lowest Tenderer |
| Sl No | Description | Qty | Unit | RK ENTERPRISES L1 | SRI GURU RAGHAVENDRA ELECTRICALS L3 | SRK ELECTRICALS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling the damaged brick / stone masonry work in cement mortar and clearing away with carefully stacking the material useful for re-use for any thickness of wall under 3m heights etc., complete complying with standard specification and as directed by the departmental officers. | 13.5 | m3 | 315 ₹4,252.5 Lowest | 500 ₹6,750 | 318 ₹4,293 |
| 2.00 | Dismantling the damaged ceiling old Thatched Roof including tying materials into small bundles and clearing away etc., complete complying with standard specification and as directed by the departmental officer. | 47 | m2 | 10 ₹470 | 9.44 ₹443.68 Lowest | 10 ₹470 |
| 3.00 | Dismantling the damaged floor finish and dadooing walls in cement mortar with mosaic tiles / Glazed tiles / cuddapah slab and clearing away with carefully stacking the material useful for re-use for any thickness etc., complete complying with standard specification and as directed by the departmental officer. | 19 | m2 | 68 ₹1,292 | 67.4 ₹1,280.6 Lowest | 69 ₹1,311 |
| 4.00 | Dismantling, removing and carefully stacking Reinforced cement concrete and roughening the surface etc., complete complying with standard specification and as directed by the departmental officers. | 1.3 | m3 | 4,787 ₹6,223.1 | 4,739.57 ₹6,161.44 Lowest | 4,834 ₹6,284.2 |
| 5.00 | Dismantling the damaged doors and windows including removal of frames, hinges, fastenings and clearing away etc. complete complying with standard specification and as directed by the departmental officers. | 3 | m2 | 171 ₹513 | 168.92 ₹506.76 Lowest | 172 ₹516 |
| 6.00 | Dismantling, clearing away and carefully stacking materials use ful for re-use for any thickness of Pressed tiles and weathering course etc.complete and as directed by the departmental officers. | 226 | m2 | 51 ₹11,526 | 50.58 ₹11,431.08 Lowest | 52 ₹11,752 |
| 7.00 | Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). | 112.06 | m2 | 1,140 ₹1,27,748.4 | 1,128.25 ₹1,26,431.7 Lowest | 1,151 ₹1,28,981.06 |
| 8.00 | Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). | 247.5 | m2 | 968 ₹2,39,580 | 958.75 ₹2,37,290.63 Lowest | 978 ₹2,42,055 |
| 9.00Cement Concrete 1:1-1/2:3 (One Cement, One and a half crushed stone sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including Super Plasticiser, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers - manual mix (Data as per new Data book SL. No.155) | ||||||
| 9.01 | For first floor superstructure | 44.2 | m3 | 10,029 ₹4,43,281.8 Lowest | 12,000 ₹5,30,400 | 10,128 ₹4,47,657.6 |
Tender Value
Refer Docs
EMD Value
₹39,000
Closing Date
23 Jun 2025, 3:00 pmClosed
The Superintending Engineer, PWD.,
O/o. The Superintending Engineer, PWD., Buildings (C and M) Circle-1, Chepauk, Chennai-5
Extension of Paramedical Education Building in First Floor at King Institute of Preventive Medicine and Research Campus, Guindy, Chennai-32
2025_PWD_559752_2
PWD/BCMC1/05-01/2025-26
Open Tender
Civil Works
Lump-sum
120 days
Guindy
Refer Tender Condition
7 documents required · 7 mandatory
₹0
₹39,000
4 Sept 2025
20 Jun 2025
23 Jun 2025
20 Jun 2025
23 Jun 2025
20 Jun 2025
Amount
Dismantling the damaged brick / stone masonry work in cement mortar and clearing away with carefully stacking the material useful for re-use for any thickness of wall under 3m heights etc., complete complying with standard specification and as directed by the departmental officers.
Dismantling the damaged ceiling old Thatched Roof including tying materials into small bundles and clearing away etc., complete complying with standard specification and as directed by the departmental officer.
Dismantling the damaged floor finish and dadooing walls in cement mortar with mosaic tiles / Glazed tiles / cuddapah slab and clearing away with carefully stacking the material useful for re-use for any thickness etc., complete complying with standard specification and as directed by the departmental officer.
Dismantling, removing and carefully stacking Reinforced cement concrete and roughening the surface etc., complete complying with standard specification and as directed by the departmental officers.
Dismantling the damaged doors and windows including removal of frames, hinges, fastenings and clearing away etc. complete complying with standard specification and as directed by the departmental officers.
Dismantling, clearing away and carefully stacking materials use ful for re-use for any thickness of Pressed tiles and weathering course etc.complete and as directed by the departmental officers.
Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Cement Concrete 1:1-1/2:3 (One Cement, One and a half crushed stone sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including Super Plasticiser, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers - manual mix (Data as per new Data book SL. No.155)
For first floor superstructure
Supplying, fabricating and placing in position Mild Steel / Ribbed for Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) (Data as per new Data book SL. No.168)
For first floor superstructure
Cement Concrete 1:2:4 (One Cement, Two crushed stone sand and Four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges, centering and shuttering but including Super Plasticiser, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three P.Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers - manual mix (Data as per new Data book SL. No.154)
For second floor superstructure
Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.
Brick jelly lime concrete 1:2:5 (one lime, two sand, five brick jelly using 20mm brick jelly for foundation etc. including dewatering if found necessary and laid in layer of not more than 15 cm thick compacting etc. complete as per standard specification and as directed by the departmental officers.
Rectification of columns, beams, slabs, brick work and sunshade by dismantling and chipping distressed portion removing the rusted reinforcement by using wire brush and by sand blasting cleaning, compressed air and water washing, applying anti corrosive inhibitor coating at the rate of 1.20kg/m2 over the affected area as per specification given by the manufacturing guniting with cement mortar 1:3 (one of cement and three of P-sand) to an average thickness of 40mm under required pressure and then neatly finishing including hire charges for guniting machineries and all tools and plants, labour charges, fuel charges including all leads for portable with water including curing 7 days and all other incidental charges etc. complete.
Construction of Brick work in Cement Mortar 1:5 (One Cement and Five Crushed Stone Sand) using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. (Data as per new Data book SL. No.200.b)
For first floor superstructure
Brick partition walls of 11.50cm thickness using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
For first floor superstructure
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers (Data as per new Data book SL. No.302)
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. (Data as per new Data book SL. No.297)
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 20mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used curing etc. complete complying with standard specification and as directed by the departmental officers. (Data as per new Data book SL. No.301)
Paving the floor with best quality double charged vitrified Tiles of 600x600x8mm size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) (Data as per new Data book SL. No.256)
Paving the top of roof with new Solar Reflective Ceramic Tiles of required design of size (12"x12") 305 x 305 x 7mm thick of approved make over base layer of cement mortar 1:3,(One cement and three sand) 12mm thick and laid straight alignment and pointed neatly with tiles and cement in ratio 1:3 with epoxy packing for joints laid without any air gap in the tiles neatly and fixing in position as per standard specification and as directed by the departmental officers. The colour and quality of tiles should be got approved by the Executive Engineer before use on work. (Data as per new Data book Sl.No.318)
Flooring with ceramic tiles of 305x305x6mm size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) (Data as per new Data book Sl.No.257)
Dadooing the walls with new printed design ceramic tiles of approved quality, colour and design of size 450x300x8mm thick tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) (Data as per new Data book Sl.No.260.f)
50mm thick slab (using 20mm HBGS Jelly)
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of 50mm thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing new one in position of Hilux board false ceiling using 10.00mm thick of approved quality and design suspended from the ceiling using 'U' shaped galvanized iron channel of size 25x25x0.55mm thick at 1.20m centre on both longitudinal and cross direction for vertical support and fixing 'U' shaped G.I channel of size 50x30x 0.55mm thick at 0.90m centre to centre on longitudinal direction respectively for horizontal support by using T.W reapers at corners & at intermediately fixing of plaster of parries on the panel provided as per design /pattern given by the site officer & finishing the ceiling surface with same plaster of pairs materials etc. Necessary openings should be covered with Acrylic panel complying with std. specification and as directed by the departmental officers etc. complete cost including all materials such as Rawl plugs, bolts and nuts, G.I pipes, metal star screws paper tape, jointing components etc, complete. All the materials should be got approved before use on work by the Executive Engineer.
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) sliding Windows from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
Supplying and fixing with new one of aluminium anodized natural colour matt finish aluminium Partly glazed, partly pre laminated board partition with alu. Box section of size 63.50mmx 38.250mm x x2.25m @ 1.256kg/m, horizontally members are spaced at 90cm center to centre and to vertically members are spaced at 1.20m, 2.10m, and 2.80m height from floor level, bottom panels should be covered with 9mm thick PLB exterior grade for partly @ bottom and partly @ top of partition is covered with 4mm thick plain glass and fixed with necessary alu. clips of size 19mmx 17.30mm x 0.90mm at 0.124kg/m, L angles screws etc, the aluminium surface is to be anodized with matt finish under electrically controlled condition in accordance with ISI 1868/1962 specification for an average anodic film thickness the rate is inclusive of materials conveyance scaffolding if any required etc, and necessary dismantling making holes in the RCC brick masonry where necessary with power drill to the extent required and made good to the original condition after fixing the partition as directed by the departmental officers. All the material should be got approved by the Executive Engineer before fixing in position.
Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish of single leaf door with half panelled with 12mm thick both side laminated particle board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section Vertical & Top rail: 50x44.45x2.50mm @ 1.292 kg/m ,Bottom rail: 100 x44.45 x 2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/m, Alu Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 Kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - Each., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 1No ., lock-1No., Door stopper with rubber bush including cost of materials labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beams, masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc., complete complying with standard specification and as directed by the deparmental officers. All the Alu. Section are to be anodised with matt finish under electricaly controlled conditions in accordance with IS 1868/1962 for an average anatic film thickness of 15 microns etc., complete.Aluminium sections,and furniture fittings shall be got approved by the Executive Engineer incharge. (Data as per new Data book Sl.No.472)
Supplying and fixing with new country wood wrought and put up for frames of doors, windows and ventilators and any other similar joinery works including cost of country wood scantlings and labour charges for manufacturing the frames and fixing hold fasts and fixing in position etc. for all lengths as per architect designs. (Data as per new Data book Sl.No.469)
Supplying and fixing solid core flush shutter of following type with thickness and necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm) , 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf.
Easing and repairing hanging doors, window shutters and refixing the same after attending the petty repairs including fixing furniture fittings and excluding cost of furniture fittings etc., complete complying with standard specification and as directed by the departmental officers. (Data as per new Data book Vol II Sl.No.83)
Supplying and fixing in position of new mild steel grills for gates, doors, ventilators and windows using M.S flats and square rod etc. The rate is inclusive cost of all materials, labour for fixing, including one coat of primer etc. complete complying with standard specification and as directed by the departmental officers. (Data as per new Data book Vol II Sl.No.63)
Supplying and fixing in position white glazed European Water Closet of best quality and approved make with 100 mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Enginer before use on works) (Data as per new Data book Vol II Sl.No.660)
Supplying and fixing in position best quality and approved make Indian made whiteglazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia “B” class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). (Data as per new Data book Vol II Sl.No.653)
Renewing the damaged Health faucet with new stainless steel health faucet with ISI mark of approved quality and brand including labour charges for fixing in position etc. complete as directed by the departmental officers.
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) (Data as per new Data book Vol II Sl.No.663)
Supplying and fixing in position with new following taps (heavy type) of approved make confirming to IS specification and quality including cost of shellac, thread, cutting and threading wherever necessary etc. complete complying with standard specification and as directed by the departmental officers.(Tap should be got approved by the Executive Engineer, before use on work) (Data as per new Data book Vol II Sl.No.645)
15mm Brass two-in-one tap
15mm brass SD tap
15mm dia CP angle cock tap
Supplying, laying and jointing UPVC pipes of Class 5 (having working pressure of 10 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply above ground level / Below ground level. (Data as per new Data book Vol II Sl.No.685)
20mm (¾") dia UPVC pipe
25mm (1") dia UPVC pipe
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work. (Data as per new Data book Vol. II Sl.No.644)
25mm (1") dia GM Gate valve
20mm (¾") dia GM Gate valve
Supplying and fixing in position best quality PVC soil / Waste pipes of following sizes with ISI mark and providing leak proof joints including fixing to the wall with special PVC/MS clamps etc., and making connection to all sanitary fittings, dismantling masonry/RCC works wherever necessary and making good the dismantled portion to the original condition, complying with standard specification etc. complete.
75mm dia PVC soil pipe
110mm dia PVC soil pipe
160mm dia PVC soil pipe
Supplying and fixing with new following UPVC specials of approved quality and brand including fixing and finishing neatly in position etc. complete.
20mm dia UPVC Elbow
25mm dia UPVC Elbow
20mm dia UPVC Tee
25mm dia UPVC Tee
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and redoing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). (Data as per new Data book Vol II Sl.No.674)
160mm dia PVC elbow
110mm dia PVC elbow
75mm dia PVC elbow
160mm dia PVC Tee
110mm dia PVC Tee
75mm dia PVC Tee
160mm dia PVC Bend
110mm dia PVC Bend
75mm dia PVC Bend
160mm dia PVC Shoe
110mm dia PVC Shoe
110mm dia PVC Vent Cowl
75mm dia PVC Vent Cowl
PVC Reducer 110x75mm
PVC Reducer 160x110mm
Supplying and fixing with new P.V.C rain water downfall pipe of 110mm dia of 4kg/cm2 approved quality including fixing in position to true alignment with PVC shoes, PVC bends and other special clamp, T.W plugs and screws etc.,complete as per specification and as directed by the departmental officers.
G.F - P.V.C rain water downfall pipe
F.F - P.V.C rain water downfall pipe
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work.
Supplying and refixing factory made Wood Polymer Composite (WPC) Solid door shutters with frame of size 100 x 65mm with high density rigid solid wood polymer composite of 0.70WPC foam sheet as per ISI marked of 20-30mm thick, mitre cut at two corners and joined and two vertical door profiles are to be reinforced to horizontal member and the door shall be fixed to the wall using 6Nos 150mm long M.S holdfastners through the frame, aluminium fixtures, butt hinges, aldrop, toer bolt, handles, including no. of screws, bolt and nuts including labour charges for fixing the frame in position and fixing the shutter to the frame (The vertical frame ofdoor dhall be embedded in flooring for a depth of not less than 10mm)etc., complete complying with standard specification and as directed by the departmental officers.
Construction of INSPECTION CHAMBER 600x600x600mm clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of Clay burnt Bricks of size 9” x 43/8” x 23/4” with Class designation of 7.5 and Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification.
Supplying and fixing with the new PVC Water tank of 2000 litres capacity with all fittings including loading, unloading and lifting the tank to terrace and fixing properly to the existing G.I lines without disturbing the masonry structures etc., complete complying with standard specification and as directed by the departmental officers.(The Capacity of the tank may vary according to the delivery lines as by the officers in charge)
Providing Cup-board Shutter with frame using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.
Painting the old plastered wall surface with two coats of first quality Plastic emulsion paint of approved quality and colour over the existing walls in all floors etc complete complying with standard specification and as directed by the departmental officers. The colour and quality should be got approved by the Executive Engineer before use.
Painting two coats of newly plastered wall surface with plastic emulsion paint of first class quality and of approved colour over a priming coat including horough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers..
Painting the old plastered wall surface with two coats of first quality Exterior emulsion paint of approved quality and colour over the existing walls in all floors etc complete complying with standard specification and as directed by the departmental officers. The colour and quality should be got approved by the Executive Engineer before use.
Painting two coats of newly plastered wall surface with Exterior emulsion paint of first class quality and of approved colour over a priming coat including horough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers..
Painting Old wood work with Two coat of synthetic enamel ready mixed paint of approved quality colour and brand to be approved by Executive Engineer before use on work, including removal of old paint from wood works, thorough scrapping, preparation of surface, cost of brushes, high scaffolding charges and neat finishing complying with standard specification and as directed by the departmental officers. (Data as per new Data book Sl.No.366)
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) (Data as per new Data book Sl.No.368)
Supplying of LINEAR MODULAR WORKSTATION 3 SEATER Size : 1200mmx 525mmx1200mm (H) - Frame 75mm thickness with powder coated finish along with the provision of electrical race way and tile of 9mm thick pre-laminated particle board opetional white board, plain glass, magnetic board, top - fabricated out of 25mm thick postformed edge using 0.60mm thick flex lmainted with plain partition board along withy MOBILE PEDESTAL size - 400mmx450mmx640mm (H)-fabricated out of 18mm thick prelaminated particle board duly edge bended with 2mm PVC beeding having two drawer with one filling drawer along with handle and lock and key arrangment, KEYBOARD TRAY size 600mmx300mm fabricated out of 18mm thick prelaminated partticle board with 2mm PVC beeding, CPU Troilly - MS powder coated etc. as per standard specification directed by the departmental officers
Supplying of L TYPE MODULAR WORKSTATION SINGLE SEATER Size : 1500mmx1500mmx 600mm x1200mm (H) - 75mm thickness with powder coated finish along with the provision of electrical race way and tile of 9mm thick pre-laminated particle board opetional white board, plain glass, magnetic board, top - fabricated out of 25mm thick postformed edge using 0.60mm thick flex lmainted with plain partition board along withy MOBILE PEDESTAL size - 400mmx 450mmx 640mm (H)-fabricated out of 18mm thick prelaminated particle board duly edge bended with 2mm PVC beeding having two drawer with one filling drawer along with handle and lock and key arrangment, KEYBOARD TRAY size 600mmx300mm fabricated out of 18mm thick prelaminated partticle board with 2mm PVC beeding, CPU Troilly - MS powder coated etc. as per standard specification directed by the departmental officers
Clearing the Branches, leaves and wastage materials conveying and dumped in low places out side the campus to tipper lorry load including loading and unloading chrages for etc., complete complying with std. Specification and as directed by the departmental officers.
Collecting the scattered debris from the campus and conveying away the same to outside by lorry to a lead of 6km including loading and unloading charges and dumping in low places and leveling etc., Complete complying with standard specification and as directed by the departmental officers. (Data as per new Data book Vol. II Sl.No.67)
SRK ELECTRICALS (BID ID -1374653)
SRI GURU RAGHAVENDRA ELECTRICALS (BID ID -1375753)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_683139.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .