Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC H NO 113 APR COLONY KATANGA CANTT JABALPUR M P PIN 482001 | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹48.2 L+₹4.8 L (11.2%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹48.9 L+₹5.6 L (12.9%)Rejected-Finance 0 0 NA AZAD CHOWK VILLAGE TOWN SADAR BAZAR CITY JABALPUR JABALPUR MADHYA PRADESH 482001 INDIA | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹49.7 L+₹6.3 L (14.6%)Rejected-Finance 292 GROUND FLOOR D BLOCK SAI DHAM RAJ CITY LONI BANTHLA GHAZIABAD GHAZIABAD UTTAR PRADESH 201102 | GHAZIABAD | UTTAR PRADESH | 201102 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹48.3 L
EMD Value
₹96,600
Closing Date
2 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
SPL REPAIR OF SINGLE OFFRS ACCN BLOCK NO T-72 OF HQ 1 STC AND REPLACEMENT OF BER GEYSER AND CERTAIN MINOR WORK UNDER GE (WEST) JABALPUR
2022_MES_513414_1
8246/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹96,600
11 May 2022
12 Mar 2022
4 Apr 2022
12 Mar 2022
2 Apr 2022
19 Mar 2022
14 Mar 2022 - 17 Mar 2022
60 days
Amount
Taking down cement plaster / terrazzo of any description thickness including raking out joints hacking for key scrubbing down with water all as specified.
M&L for 10mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all specified and directed.
M&L for 15mm thick rendering on concrete/brick surfaces in CM 1:4 using with water proofing compound as per manufactures instruction finished even and smooth without using extra cement complete all as specified .( Note:- WPC measured and paid saperately)
M&L for 5mm thick rendering in Cement Mortar 1:3 on Concrete Surfaces, ceiling etc finished surface Even and Smooth, without using extra cement
M&L for preparation of newly plastered surfacces and applying three coat of white wash as in ceilling complete all as specified and as directed.
M&L for Preparing Newly Plastered Surfaces of internal wall and applying two Coats of oil emulsion distemper over 3 mm thick wall care putty on wall plastered surface complete all as specified and as directed.
M&L for Preparing Newly Plastered Surfaces of external Walls and applying Two Coats of Cement Base Paint over a coat of primer complete all as as specified and as directed. Note:- Curing shall be done before and after applying of paint.
M&L for complete removal of existing treatment & washing rubbing down and stopping of distempered and painted surfaces incl preparation of old undecorated surface of walls and applying two coats of cement base paint on external wall Priming plastered and other surfaces with alkali resistant priming paint complete all as specified and directed. Note:- Curing shall be done before and after applying of paint.
M&L for complete removal of existing treatment & washing rubbing down and stopping of distempered and painted surfaces incl preparation of old undecorated surface of walls and applying two coats of oil bound distempered over 2mm thick wall care putty on wall over priming surafce complete all as specified and directed
M&L for Prepration of old surfaces of ceiling includinng scrapping down smoke ,soot,and efflorescent salts and treatings oil and gresy spots, brooming down or steel wire brushing removing nails making good holes cracks etc on plastered or unplastered surfaces and applying one coat of white wash on ceiling surface complete all as specified
M&L for Prepration of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint of (white or tinted) complete all as specified.
M&L for Prepration of old painted surfaces of steel of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilliate demolition complete all as specified and directed.
M & L for RCC (1:2:4) nominal Mix using 20mm graded aggregate in chajjas,parapet facia etc complete all as specified and as directed.
M&L for RCC (1:2:4) ( nominal mix) using 20mm grades stone aggregate as in Fins, fascias, louvres,parapets, and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and as directed.
Use and waste of form work to faces of walls, retaining walls , abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc, vertical or to batter surface fair finished complete all as specified and directed.
Use and waste of form work to Chajjas and similar items including edges etc complete all as specified and directed.
S&F TMT bars 6mm to 8mm dia and cut to length bent to shape required, including cranking, bending and binding as in stirrups, spacers and binders etc. with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.Note : The re inforcement shall be welded with existing re inforcemnet after dismantaling of RCC Chajjas/Parapets etc.
Roughening surfaces of old concrete floor/terrace by picking incl. taking down existing detoriated / decayed tar felt PCC tiles or any type of treatment including loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. and removing the scraped materials debris to a distance not exc. 50 m.
M&L for wire brushing and cleaning top surface of tiles,lime terracing or cement concrete,including flashing and junction of parapet,etc,and surface painting with a layer of blown bitumen of any penetration applied hot @1.70 kg per sqm.blinded with grit or pea size gravel @ 0.006 cu.m per sqm and lightly tampered (area of flashing etc.shall be added to the roof area.
M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound @ 3 % by weight of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed.
M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following for roofs- (a) Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/Sqm on top of dry surface of finished cement mortar plaster. (b) One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over primed surfaces. (c) One layer of APP based polymeric water proofing membrane of weight not less than 3 kg/Sqm consisting 3mm thick reinforced with polyster non wove fabric shall be unrolled surfaces with lap of 100 mm and the over lap shall be sealed by flame. (d) Applying two coats of aluminum paint on top of membrane @ 0.10Kg/Sqm.
Demolition of concrete of any description and in any position all as specified
M&L for 25mm thick cement concrete Type B-0 1:2:4 (Using 12.5mm graded aggregate ) as sub base to receive till as complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:3) on brick or concrete surfaces in two layers mixed with water proofing compound @ 2% by weight of cement in top 5mm thick, finishing the surfaces with even and smooth with using extra cement complete all as specified and directed. ( Note:- WPC measured separately)
M&L for Bitumen blown any grade , applied hot, two coats to concrete surfaces at the rate of 1.5Kg sqm per coat. Including polythene film, black , 50 micron laid in floors.
M&L for lean concrete (1;7:12) Type F2 (using 40mm graded stone aggregate) laid compacted all as directed and specified
M&L for cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof kerbs PCC as in kerbs/covet fillet complete all as specified.
S&F GI tubing 40mm bore medium grade fixed to wall and ceiling or laying in floor as sunken spout all as specified and directed
Supply only integral water proofing compound
Demolition of brick work as in walls/parapet wall,s removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces .
M&L for Brick work with sub class ‘B’ brick, straight or curved as plan exc 6m mean radiusbuilt in cement mortar 1:6 complete .
M&L for Brick work with sub class ‘B’ brick, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete .
Dismantaling floor hearth or wall tiling/china moisac including cement mortar bedding (but not backing ) , removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for glazed ceramic coloured tiles of size 450mm x 300mm x 6mm to 7mm, 450mmx350mm or 350mmx250mm, 6 to 7mm thick on vertical surface such as skirting/dado etc. ,set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile fixed over and including rendering 10 mm thick cement plaster in cement mortar 1:4 finished rough to fix tiles complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 7 to 8mm thick square/ rectangular area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match, laid over and including 15mm thick cement screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for vetrified ceremic tiles 10 mm thick, in LIGHT SHADE, (Square/rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specfied and directed.
M&L for Vitriefied ceramic tiles 10mm thick LIGHT SHADE(square/rectangular) polished area of each tiles not exceeding 0.36 sqm as in vertical surfaces such as dados/skirting etc set and jointed in neat cement slury and in coloured cement to match Coloured/ fixed over and incl plaster (backing coat) 10mm thick in CM 1:4 etc all complete.
M&L for Granite (of any type ) 20 mm thick work (table rubbed and polished ) in steps ,jambs,pilllars,window cill,cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2)using marble dust with admixture of pigment to match with shade of Granite laid over 20mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Machine cut Cudappha stone slab on cooking platform/shelf fixed over and including 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over 15mm thick screed bed in CM 1:6 complete including rubbing and polishing etc all specified and directed
M&L for rounding to edges of granite stone slabs one edge such as in counter type WHB platform etc. to the entire satsfaction of Engineer-in-Charge..
Demolition of cement concrete in ground floor and paving not exc 15cm thickness (below or above ground level) all as specified.
Material and labour for 20- 25 mm thick machine cut kota stone flooring laid and jointed with neat cement slurry mixed with pigment to match the shade of the slab laid over and including 20 mm thick bedding layer in cement mortar 1:6 including rubbing and polishing complete all as specified..
M&L for 18 to 20 mm thick machine cut kota stone as in vertical surfaces risers of steps , skirting, dado and pillars etc as in single peace set and jointed in neat cement slurry and pointed with grey cement mixed with pigment to match the colour of stone slab laid over and including 10 mm thick rendering in cement mortar 1:4 including rubbing and mirror polishing complete all as specified.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40mm graded aggregate as in plinth protection finishing even & fair without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 gde and three part of sand (1:3) ( all by weight) complete.
M&L for 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete and sub base finished even & fair complete.
M&L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment, confirming to IS 15658-2006 of 60mm thickness M 35 Grade fixed over and including 50mm thick sand coushioning etc complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers ,apex stones, bed plates, water troughs and the like including use of formwork (straight or curved) ,including weathering, slightly rounded or chamfered angles and throating, all as specified and as directed (Note :-reinforcement where provided shall be measured and paid seprately)
Taking down chowkhats or frame (with shutter w/o taking off shutter from the frame) area not exc 1.5 Sqm each all as specified.
Taking down chowkhats or frame (with shutter w/o taking off shutter from the frame) area exc 1.5 Sqm but n-exc 4 sqm each .
S&F pressed steel door frame 105x60 mm with one or more rebated incl necessary fixing lugs hings, lock strick , etc complete, as specified and directed.
S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed ® size 125x 60 mm
S&F, Aluminium anodised sections for doors/ windows/ ventilators with one or more rebates including joining cleat including locking arrangment for fixing etc complete with frames, shutters and grills of size directed by Engineer-in-charge including complete all as specified and directed. Note:- sheet glass, wire cloth shall be measured and paid seperately.
M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in filling of pressed steel door frame complete all as specified and directed.
S & F 40 mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides decorative face veneer with lipping/frame to match supplied and fitted to chowkats.
S & F 25 mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides supplied and fitted to chowkats.all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails . M,S frame shall be covered with heat moulded plain colour PVC ,C, channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and Single Side Prelam PVC sheet used instead of Plain colour PVC sheet and stile & rails having one side feathered edge and on other side 10mm 900 bent edge.wire gauzed i.e. panel will be of wire gauze in lieu of single side prelam PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S Solid tube and this tube shall be welded to M.S tubes. The stainless steel wire gauge deemed to be included and shall be stretched to tighten firmly complete all as specified and directed.
S&F PVC door frame size 50mm x 47mm made out of 5mm single side prelam PVC Sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet reinforced with MS tube complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutters with particle board core 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plan colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing
S&F aluminium anodised, barrel tower bolts of extruded section with length of bolt 200 mm and fixed complete all as specified and directed
S&F aluminium anodised, barrel tower bolts of extruded section with length of bolt 150 mm and fixed complete all as specified and directed
S&F aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy with length of bolt 300 mm and fixed complete all as specified and directed.
S&F 100mm butt hinges extruded aluminium alloy with galvanised mild steel hinge pin,Type-B-21 complete all as specified and directed.
S&F continuos (piano) hinges,mild steel bright finish or electrogalvanised,width of flaps 30 mm all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type, anodised of size 125 mm complete all as specified and directed.
S&F 150mm long floor door stopper of aluminium alloy body and tongue with hard drawn steel springcomplete all as specified and directed.
S&F 300mm long mild steel ordinary rat tail rod pattern springs,including roller and roller plate complete all as specified and directed.
S&F 125mm hasp and staples,aluminium anodized including bolt to hinges plate and fixed with screws complete all as specified and directed
S&F stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staple/ wooden beads complete all as specified.
S&F in repair 9 mm thick prelaminated particle board interior grade,prelaminated both sides with decorative choice laminaions fixed with screw to timber/steel frame work as in repair all as specified
S&F in repair 18/19 mm thick prelaminated particle board interior grade,prelaminated both sides with decorative choice laminaions fixed with screw to timber/steel frame work as in repair all as specified
S&F 3mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified
S&F 4mm thick figured glass, pinn headed type and glazing with oil putty in square n. exc 0.5 sqm each panes complete all as specified
S&F mild steel framed work such as guard bars/grills,grating etc with end of bars shouldered and/or riveted or forged into spikes and similar works including one shop coat of zinc chromate primer complete all as specified.
S&F aluminium hat & coat hooks solid body 125 mm to 175 mm fixed with brass screw complete all as specified and directed.
S&F MS Peg set of six powder coated as approved by GE
M&L for mild steel pipe 25 mm dia Drapery rod fancy type with PVC coating fixed in the MS hooks, and finials/side brackets (both side), shade as approved by GE all as specified.
M&L for Cutting holes in brick walls in exc half brick and nexc one brick in cement in mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 complete all as specified and directed.
M&L for treating small article such as stops, covers, gully, gratings and hold fast ends & post backs of chowkat etc with creosote oil, tarred area n exc 0.10 Sqm each
M&L for Preparation of newly steel surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
S & F in repair GI Tubes medium grade, 15mm bore galvanised with all fittings and fixed complete to wall (Conceiled)and ceiling or laid in floors Complete all as specified and directed.
S & F GI Tubes medium grade, 15mm bore galvanised with all fittings and fixed complete to wall (Conceiled)and ceiling or laid in floors Complete all as specified and directed.
S&F in repair Tubes medium grade, 20mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors Complete all as specified and directed.
S&F in repair Tubes medium grade, 25mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors Complete all as specified and directed.
Cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete.
S& F in repairs Stop valve / Angle valve fancy type cast copper alloy chromium plated screwed down high pressure with capstan heads screwed both ends for iron pipe or for union and fixed 15mm bore complete all as specified and directed.
S& F Stop valve / Angle valve fancy type cast copper alloy chromium plated screwed down high pressure with capstan heads screwed both ends for iron pipe or for union and fixed 15mm bore complete all as specified and directed.
S& F in repairs 15 mm bore bib tap cast copper alloy, chromium plated, long body fancy type with capstan headed, screwed down, screwed for iron pipe complete all as specified and directed.
S& F 15 mm bore bib tap cast copper alloy, chromium plated, long body fancy type with capstan headed, screwed down, screwed for iron pipe complete all as specified and directed.
S&F in repair for 15mm chromium plated brass WHB mixer fancy type swan neck long nose- screwed down high pressure with or without lettered hot and cold and flynuts 15 mm dia complete all as specified and directed.
S&F in repairs fancy type wall mixture of brass, chromium plated, 3 in 1 system with hot and cold arrangement, with provision for both hand shower & overhead shower complete Make Prayag,Hindware,Parryware
S&F in repair C P glass corner shelf set of three single including Screws and CP bracket complete all as specified and directed.
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guards and railing 600 mm long complete all as specified.Make- Jaquar Cat Part No- AKP 35715PS
S&F in repair Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall Size 915mmx460mm with bowl size 410mm x330mm x 160mm of make : Nirali Bluestar or equivalent
S&F in repairs kitchen plate rack made of stainless steel 1mm thick complete size 1200 x 900mm x 200mm width of trade pattern complete all as specified.
S&F in repair Soap dish, stainless steel approx size 160mm x 160mm x 90mm complete all as specified and directed.
S&F in repair 32 mm bore low density polythelene pipes (LDPE) with fittings of pressure rating 6 Kgf / Sqcm fixed to walls or in floors etc complete all as specified and directed.
S&F in repair PVC connection 450 mm long, 15mm size with PTMT nuts complete all as specified
S&F in repairs grating doom 125mm dia PTMT with waste hole (Min weight 40 grms)
S& F in repairs chromium plated shower rose 200x200 mm size and 15mm dia with or without swivel joints including fixing to pipe and union complete all as specified and directed
S&F in repair, PVC Bath Cabinet made from hard thermosetting material with mirror, white/ivory colour, 400 x 500mm size. Complete all as specified and directed.Make- Prayag Cat Part No 554
S & F in repairs Towel rail 600 mm long and 20 mm dia brass chromium plated D type fixed with screws and wooden or plastic cleats complete all as specified and directed.
S & F in repairs Towel ring brass chromium plated round type fixed with screws and wooden or plastic cleats complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan Padestal pattern white excluding fixing bolts, flushing cistern and flush pipe with and incl 'P' or 'S' trap and making good to floor to match with existing all as specified and directed.
S&F in repair Plastic water closet seat, white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device complete all as specified. Make- as approved by GE.
S&F in repairs 10 ltr PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle with flush pipe complete all as spfd
S& F in repairs Vitreous China wash hand basin, white, flat back, size 550mm x 400mm including brass coupling, mild steel brackets fixed to wall, with pedestal complete all as specified and directed.
S&F, in repair, chromium plated, Toilet paper holder complete all as specified and directed. Make- Jaquar ACN-1151N
S&F in repairs CP waste fittings brass chromium plated for sink 32mm dia with long screws sinks and fly nuts , flenge end bedded in red led cement and other in fixed all as specified and directed.
S&F in repairs CP waste fittings brass chromium plated for sink 40mm dia with long screws sinks and fly nuts , flenge end bedded in red led cement and other in fixed all as specified and directed.
S&F in repairs 100mm dia cast iron floor trap plain with grating including jointing and fixed with cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F in repairs for 75mm diaPTMT multi floor trap plain with grating including jointing with solvent cement complete all as specified 7and directed.
S&F in repairs 110 mm dia PVC (SWR ) pipes Single socketed in any length with rubber rings ljoits fixed to walls complete all as specified and as directed.
S&F in repairs PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete.
S&F in repairs 110 mm dia PVC (SWR ) branches piece,double (double Y) equal or unequal with access doorrubber rings ljoits fixed to walls complete all as specified and as directed.
S&F in repairs PVC (SWR) branch pieces, single (equal or un equal) , ordinary or inverted (spigot or socket type) or with parralled branches of 110 mm dia with access door
S&F in repairs 110 mm dia PVC (SWR ) bends any radius with access door complete all as specified and as directed.
S&F in repairs 75 mm dia PVC (SWR ) bends any radius with access door complete all as specified and as directed.
S&F in repairs 110 mm bore PVC (SWR) vent cowl including jointing with solvent cement complete all as specified and directed.
S&F in repairs PVC(SWR) Tee of 110mm dia with access door etc complete all as specified and directed
S&F in repairs PVC(SWR) Tee of 75mm dia access door etc complete all as specified and directed
S&F in repairs PVC (SWR) gully trap 125 x 110 mm setting and jointing with solvent cement complete all as specified
S&F stack clamps out of 50mm by 5mm flat iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore etc all as specified.
S& F in repairs 500 ltrs rotational moulded polythine water storage tanks( cylinder vertical with closed top) hoisted and fixed in position including 20mm bore ball valve high pressure PTMT with epoxy coated aluminium rod & high densitypolythene float ball and fly nut screwed for iron pipe complete all as specified.
S&F in repairs 20mm dia gun metal,globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed
S&F in repairs 25mm dia gun metal,globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets including E- Grid frame work complete all as specified and directed.
S&F suspended false ceilingwith T- grid system of size 600 x 600mm with following specifiactions :- (i) Pre primed, self embossed, textured designer board, water resistant, termite resistant, fire resistant for insulation Calcium Silicate Boards 6mm thick (ii) GI powder coated Main Tee of size 38x24mm made out of 0.30 mm (min) thk sheet (ii) GI powder coated Cross Tee of size 24x24x0.30 mm (min) made out of 0.30 mm (min) thick sheet (iii) GI powder coated angle of size 24x24x0.30 mm (min) made out of 0.30 mm (min) thick sheet (iv) Level clip / suspension wire - 4 mm dia GI wire. (v) Soffit cleat/Rawl Plug as per manufacturers instrcutions (vi) Fixing shall be executed as per manufacturers instructions
Re-Fixing only 6mm to thick in ceiling flat or sloping Non asbestos cement building boards fixed or laid/inserted to timber/GI/Aluminium frame work fixed with screw as per manufacturer's instructions all as specified and directed
Dismantling of asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings
S&F Pre-painted galvalume aluminium zinc coating GI based corrugatged steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified
Dismantling timber fillets,posts rafter purlin under 40 sqcm framed work in sectional area,complete all as specified and as directed.
Dismantling timber in scantling 40Sqcm and over in section framed work in any position complete all as specified and directed.
Dismantling wroght iron or mild steel work of any description not oterwise provide for
S&F hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc,) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe410-0 or Fe 310-0 complete all as specified and directed.
S&F mild steel screw bolt (machine made) with square or hexagonal head at one end, screwed other, fitted with washer and one hexagonal or square n exc 5cm, long and 5 to 10mm dia complete all as specified and directed.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to a common rafters, fixed with angle cleats or other connecting plates of Gde fe 410-0 or fe 250-0
M&L for Prepration of newly painted steel surfaces of any description n exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer surface complete all as specified.
M&L for preapring surfaces of wood and wood based materials,old surfaces of any descriptionand girth,not otherwise described and treated with one coat of creosote oil complete all as specified and directed.
M&L for providing and injecting chemical emulsion for post construction anti -termite treatment of soil under existing floors using emulsion @ one litres per hole ,300 mm apart including drilling and plugging 12mm dia holes with cement mortar (1 cement :2 coarse sand ) to match the existing floors complete all as specified and directed.
M&L for providing and injecting chemical emulsion for post construction anti -termite treatment along the external wall below concrete or masonry apron using chemical emulsion @2.25 litre per linear meter including drilling and plugging holes etc. complete all as specified and directed.
Supplying and fixing,testing the water heater storage type 25 litres, BEE Five star Rated capacity and after connecting electric and water connection and screwing nuts and bolts , anchor hold fast to fixed on wall and making the good the disturbed surface, complete all as required and as directed at site.Make: Bajaj/Racold/Havells.
Supplying and fixing,testing the water heater storage type 50 litres, BEE Five star Rated capacity and after connecting electric and water connection and screwing nuts and bolts , anchor hold fast to fixed on wall and making the good the disturbed surface, complete all as required and as directed at site.Make:Bajaj/Racold/Havells.
Supply & fix in repair PVC connection pipe 450mm to 600mm long as required at site complete with PTMT symet nuts on both ends suitable to carry hot water at 60 temp complete all as specified and as directed. Make:- Prayag/ Polytuff/ Shakti
Supply & fix PVC connection pipe 450mm to 600mm long as required at site complete with PTMT symet nuts on both ends suitable to carry hot water at 60 temp complete all as specified and as directed. Make:- Prayag/ Polytuff/ Shakti
S&F in repair for Sub Main Wiring two single core PVC insulated cable of size 4.0 Sqmm multistranded copper conductor two run drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and one run of 2.5 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :- Two Nos of 4.0 Sqmm Wire and one No of 2.5 Sqmm Earth wire in One RM length Measured as one unit length.
S&F Sub Main Wiring two single core PVC insulated cable of size 4.0 Sqmm multistranded copper conductor two run drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and one run of 2.5 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :- Two Nos of 4.0 Sqmm Wire and one No of 2.5 Sqmm Earth wire in One RM length Measured as one unit length.
Taking down carefully any type point wiring (light, fan, socket bell or power) , complete with fitting such as switches ceiling roses,lamp holders sockets,regulators,call bell light fitting with PVC conduit surface /concealed or wooden pattens including sunken cast iron /pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces all as specified and directed by Engineer in charge.
Taking down the ceiling fan in situ and refixing after servicing, repairing and painting to ceiling fan including scratching old paint and preparation of surface for painting with one coat of white/grey enameled paint complete all as specified and directed.
S&F in repair Sub Main Wiring two single core PVC insulated cable of size 6.0 Sqmm multistranded copper conductor two run drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and one run of 4.0 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :-Two Nos of 6.0 Sqmm Wire and one No of 4.0 Sqmm Earth wire in One RM length Measured as one unit length.
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of antirorrrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
(a) One light point/Bell point/fan/exhaust point controlled by one switch.
(b) One socket point controlled by one switch on same board.
(c) One socket point controlled by one switch on Independent board.
Description all as per item above here in before but with 1100 volts grade copper standard conductor cable of size 2.5 Sqmm with 1.5 Sqmm solid copper conductor PVC for 3 pin switch socket outlet15 Amp independent board complete all as specified and directed by Engineer in charge .
S & F bell ding dong AC 230 volts single pole one way complete all as specified and directed by Engineer in charge.
S & F Switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engineer in charge.
S & F Socket outlet 3 pin, 5 Amps and AC 230 volts flush type complete all as specified and directed by Engineer in charge
S & F switch socket combination 3 pin 5 and 16 Amps AC 230 volts flush type complete all as specified and directed by Engineer in charge
S & F Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and directed by Engineer in charge
S & F fan regulator Step Socket type of polycarbonate complete all as specified and directed by Engineer in charge.
S & F lamp holder PVC Polycarbonate type body, with back plate for batten fitting icluding 9 watt led lamp complete all as specified and as directed by Engineer in charge.
Supply and fixing in replacement of decorative wall light fitting WITH LAMPS 9 WATT made up of Polycarbonate , City-1 , Cylindrical shape , with LED lamp 9 Watt complete with fixing arrangements on wall all as specified and directed. Make:City 1 of havells or equivalent in bajaj /Philips
S & F Smart bright Batten Series, LED luminaire using LEDs 22 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets complete all as specified and as directed .Philips Cat part BN 021 LED 22S 6500/4000 PSU GR SI or equivalent
S & F in repair of LED Decorative /mirror light fitting 9 watt along with fixture Surface mounted suitable for indoor aplication , connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed by Engineer in charge. Make- Surya Catpart No Visco SLEBT 10W or equivalent in PHILIPS/ Havells
S & F in repair Bulk head endura LED light fitting complete with10 watt LED and making necessary electric connection to ceiling rose with copper conductor of suiyable size & length complete all as specified & directed. Make :- Surya Catpart No Corvi neo SLE BH10W or equivalent in PHILIPS ,Havells
Supply & fix in repair LED Security Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint. complete all as specified and as directed . Make: Surya Catpart No NGN SLEUL25WIP66 or equivalent in PHILIPS ,Havells
Supply and fixing Single phase propeller type ventilating ( Exhaust fan) heavy duty AC 230 volts 300 mm sweep, metallic body complete with Metalic louvers including making holes of suitable size and making good the disturbed surface and shutters including electric connection with pvc flexible twin core copper wire from ceiling rose to Exhaust fan, nut & bolt complete all as specified and as directed.Make:Bajaj,havells or Racold
Supply and fixing Single phase propeller type ventilating ( Exhaust fan) heavy duty AC 230 volts 250 mm sweep, Plastic body complete with louvers including making holes of suitable size and making good the disturbed surface and shutters including electric connection with pvc flexible twin core copper wire from ceiling rose to Exhaust fan, nut & bolt complete all as specified and as directed.Make:Bajaj,havells or equivalent.
S & F in repair Sheet metal enclosure DBs Tripple Pole and Neutral 4- way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and directed by Engineer in charge Make:Legrand CAT NO 507670 / SIEMENS CAT NO 8GB32203RC04 / GE
S & F in repair MCB TPN 415 volts 63 Amps, C Series complete all as specified and directed by Engineer in charge .Make : Legrand DX3 TPN C 63A AC 408683 / Siemens cat no- 5SL44637 RC / GE
S & F in repair Sheet metal enclosure DBs Single Pole and Neutral 8 way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and directed by Engineer in charge Make :- Legrand CAT NO 507611 / SIEMENS CAT NO 8 GB 32102RC8/GE
Supply and fixing in replacement MCB single pole and neutral 240 volts 40 Amps, B Series complete all as specified and directed by Engineer in charge Make : Legrand DX3 DP CAT No 408637/ Siemens cat no- 5SL 42327RC / GE
Supply and fixing in replacement MCB single pole 240 volts 6 Amp to 32 Amps, B Series complete all as specified and directed by Engineer in charge Make : Legrand cat no DX3 SP 408587,408590,408592,408593,408594,408595 / Siemens cat no- 5SL41067RC, 5SL41107RC, 5SL41167RC, 5SL41207RC, 5SL41257RC, 5SL41327RC / GE
Supply and fixing MCB single pole 240 volts 6 Amp to 32 Amps, B Series complete all as specified and directed by Engineer in charge Make : Legrand cat no DX3 SP 408587,408590,408592,408593,408594,408595 / Siemens cat no- 5SL41067RC, 5SL41107RC, 5SL41167RC, 5SL41207RC, 5SL41257RC, 5SL41327RC / GE
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.Make: Legrand cat part no Ekinox metra plug 5078 11 or havells/ anchor
Supply & Fixing single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.Make: Legrand cat part no Ekinox metra plug 5078 11 or havells/ anchor
Supply and fixing Single phase ceiling fan 1200 mm permanent magnet brushless DC Motor 230 v 50 Hz, 5 Star rating , single phase 26-30watt rated current 0.16 amp,pf 0.98 370/360 rpm air delivery 220m3 rated service value 629m3/min/watt no of blades three type of blade leaf 1.05 mm thick aluminium sheet remote control radio frequency 5 speed +off timer option speed regulation class of insulation two nos bearings including connecting wire complete with all as required and directed at site by Engr -in charge Make :- Havells Efficiencia Neo / Bajaj/ CG
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. -1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
S & F in repair for bell push piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engineer in charge.
Supply & fixing electronic energy meter tamper proof design digital technology of SINGLE phase 1 x 240 volts 50 HZ 0.4% basic current for direct connected meter and 0.2% of basic current meter with LCD display class-1 accuracy as per IS : 13779 Microprocessor based single phase energy meter of 10--60 Amp complete with all accessories complete with fixing accessories on finished wooden box all as specified & directed at site. Make :- Saral of Secure// Havells or Equivalent Note :- 1. Old UNSV Meter shall be deposited to AGE E/M Store Yard 2. The New meter would carry 5 Year Warrenty
Supply , laying and testsilng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cab les ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 25 Sqmm complete all as specified and directed by Engineer in charge Make :- Havells/ Gloster/ Polycab
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
Ditto all as per above items but cable of size 10sqmm 2 core
Ditto all as per above items but cable of size 10sqmm 4 core
M&L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
M&L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Supply and laying Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
Supply and laying Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge.
M&L for GI Tubes,of size 40 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
Supply,fixing ,connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw single phase load with contactor 63 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 63 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 16sqmm coper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts complete incl taking down of existing arrangement all as specified and directed by the Engr-in-charge. Make of nature switch - Model No Swadeep-02EC8kw1P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs- Hager/Schneider/L&T/C&S, Enclouser - Sintex or equivalent
Supply,fixing ,connecting and testing street light switching system and Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw Three phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts, complete all as specified and directed by the Engr-in-charge. Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs- Hager/Schneider/L&T/C&S, Enclouser - Sintex or equivalent
mandeka constructions
Shri kamal traders
Goodluck Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .