Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.5 LAccepted-AOC OPPOSITE SWAHID BHAWAN VILL MIRZA P O MIRZA DIST KAMRUP 781125 | MIRZA | KAMRUP | ASSAM | 781125 | L1 | Accepted-AOC L1 Bidder PandS Construction | |
| 2 | Rejected-Technical GROUND FLOOR PURVI COMPLEX A T ROAD NEAR PANBAZAAR OVERBRIDGE KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | - | Rejected-Technical Unable to submit the requisite specific experiance | |
| 3 | Rejected-Technical | - | Rejected-Technical Unable to submit the requisite specific experiance | |
| 4 | Rejected-Technical | - | Rejected-Technical Unable to submit the requisite specific experiance |
Tender Value
₹94.7 L
EMD Value
₹1.9 L
Closing Date
10 Oct 2022, 12:00 pmClosed
CGM(PPD), AEGCL
O/o the MD AEGCL, Bijulee Bhawan, Paltan Bazar, Guwahati-781001
Turnkey construction of 1 (One) No of 33KV IT Park Bay and construction of new switchyard KIOSK at 400kV Kukurmara GSS, AEGCL, Mirza
2022_AEGCL_26813_1
AEGCL_MD_Tech-1040_33KV_ITPark
Open Tender
Electrical Works
Turn-key
300 days
400kV Kukurmara GSS, AEGCL, Mirza
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
₹1.9 L
Yes
4 Jan 2023
1 Sept 2022
11 Oct 2022
1 Sept 2022
10 Oct 2022
16 Sept 2022
1 Sept 2022 - 15 Sept 2022
Amount
Supply of Equipments and accessories
33kV, 25kA, 800A, SF6 Gang operated Circuit Breaker complete with mounting structure and accessories including Terminal connectors and Gas filling kit.
33kV, 25kA, 1250A motorised isolators with Earth Switch complete with all fittings and accessories including Terminal connectors.
33kV, 25kA, 1250A motorised isolators without Earth Switch complete with all fittings and accessories including Terminal connectors.
33kV, 400/1-1A, 2-Core Single Phase CT complete with all fittings and accessories including Terminal connectors (0.2 Class, live tank type).
33 Kv 3 Phase PT including all accessories and terminal connectors as required
33kV Lightning Arrester complete with all fittings and accessories including Terminal connectors and surge counter
33kV Post insulator with all fittings including Terminal connectors
Mounting Structures with mounting & foundation bolts as per drawing.
a) 33kV Motorised isolators without Earth Switch
b) 33kV CT
c) 33kV LA
d) 33kV PI
e) 33kV Motorised isolators with Earth Switch
CRP & SAS
33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Bay level Managed Ethernet switch, rack mounting type in panel with suitable OF PATCH cable of sufficient length for SAS Integration
LIU-ABB art no: IMYN900010-WC (24 port wall mounted fiber patch panel with STMM pigtails and dapters fully loaded) suitable for untegration with existing ABB SAS
OFC cable, 62.5/125.6 core multimode (suitable for connection with LIU-ABB art IMYN900010-WC
ABT compliant energy meter including installation (SAMAST Compliant)
Insulator strings, Clamps & Connectors (UPG, T Etc.)
a) UPG clamps for connection to Bus. (Panther to Zebra)
b) UPG clamps for connection to Bus. (Panther to Panther)
ACSR Panther Conductor
Earthmat Extension and grounding of equipments
a) Main earth mat (65x12 GI flat)
b) 50x10 GI flat Earthing conductor for earthing of indoor L.T and control panels, Junction box, Marshalling boxes etc.
c) 40mm dia, 3 m long MS rod Earth Electrode,
Armoured Control Cable (Copper)
a) 4CX2.5 sqmm
b) 7CX1.5 sqmm
c) 12CX 1.5 sqmm
d) 19CX 1.5 sqmm
Armoured Power Cable (Aluminium)
a) 2CX6 sqmm
b) 4CX 16sqmm
c) 3 1/2 C X 35 sqmm
60 W LED Lights for Switch Yard Illumination, including Fitting and fixing
Supply of AC Marshalling Kiosk including construction of foundation, installation and cable foundation. 1. 2No 63A, 4P (Incomer) 2. 3No 25A, 4P (Outgoing) 3. 8No 16A, 4P (Outgoing) 4. 8No 10A, 4P (Outgoing) 5. 5No 10A, 2P (Outgoing)
Supply of Marshalling Box for CT
Supply of Marshalling Box for PT
Mandatory Spares
For 33kV SF6 CB
a) Operating Mechanism
b) Trip Coil for 33kV CB
c) Closing Coil for 33kV CB
d) Spring charging Motor
e)SF6 gas density monitor
f) Set of all Gaskets along with sealing agents
33kV, 25kA, 1250A Isolators Contact (01male, & 01 female=01 set)
33kV, 400-200/1-1A, 2-Core Single Phase CT complete with all fittings and accessories including Terminal connectors (0.2 class, live tank type)
33kV Lightning Arrester
Numerical Backup Relay @30% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Master trip Relay @ 10% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
SF6 Gas Cylinder
Bay control unit @ 30% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Clamps & Terminal connectors
(a) CT Terminal Clamp (Panther)
(b) LA Clamp (Panther)
(c) Isolator clamp (Panther)
(d) CB Terminal connector (Panther)
Description of Work / Item(s)
Amount
Supply of Equipments and accessories(F&I)
33kV, 25kA, 800A, SF6 Gang operated Circuit Breaker complete with mounting structure and accessories including Terminal connectors and Gas filling kit.
33kV, 25kA, 1250A motorised isolators with Earth Switch complete with all fittings and accessories including Terminal connectors.
33kV, 25kA, 1250A motorised isolators without Earth Switch complete with all fittings and accessories including Terminal connectors.
33kV, 400/1-1A, 2-Core Single Phase CT complete with all fittings and accessories including Terminal connectors (0.2 Class, live tank type).
33 Kv 3 Phase PT including all accessories and terminal connectors as required
33kV Lightning Arrester complete with all fittings and accessories including Terminal connectors and surge counter
33kV Post insulator with all fittings including Terminal connectors
Mounting Structures with mounting & foundation bolts as per drawing.(F&I)
a) 33kV Motorised isolators without Earth Switch
b) 33kV CT
c) 33kV LA
d) 33kV PI
e) 33kV Motorised isolators with Earth Switch
CRP & SAS(F&I)
33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Bay level Managed Ethernet switch, rack mounting type in panel with suitable OF PATCH cable of sufficient length for SAS Integration
LIU-ABB art no: IMYN900010-WC (24 port wall mounted fiber patch panel with STMM pigtails and dapters fully loaded) suitable for untegration with existing ABB SAS
OFC cable, 62.5/125.6 core multimode (suitable for connection with LIU-ABB art IMYN900010-WC
ABT compliant energy meter including installation (SAMAST Compliant)
Insulator strings, Clamps & Connectors (UPG, T Etc.)(F&I)
a) UPG clamps for connection to Bus. (Panther to Zebra)
b) UPG clamps for connection to Bus. (Panther to Panther)
ACSR Panther Conductor
Earthmat Extension and grounding of equipments(F&I)
a) Main earth mat (65x12 GI flat)
b) 50x10 GI flat Earthing conductor for earthing of indoor L.T and control panels, Junction box, Marshalling boxes etc.
c) 40mm dia, 3 m long MS rod Earth Electrode,
Armoured Control Cable (Copper)(F&I)
a) 4CX2.5 sqmm
b) 7CX1.5 sqmm
c) 12CX 1.5 sqmm
d) 19CX 1.5 sqmm
Armoured Power Cable (Aluminium) (F&I)
a) 2CX6 sqmm
b) 4CX 16sqmm
c) 3 1/2 C X 35 sqmm
60 W LED Lights for Switch Yard Illumination, including Fitting and fixing(F&I)
Supply of AC Marshalling Kiosk including construction of foundation, installation and cable foundation. 1. 2No 63A, 4P (Incomer) 2. 3No 25A, 4P (Outgoing) 3. 8No 16A, 4P (Outgoing) 4. 8No 10A, 4P (Outgoing) 5. 5No 10A, 2P (Outgoing)(F&I)
Supply of Marshalling Box for CT(F&I)
Supply of Marshalling Box for PT(F&I)
Supply of Equipments and accessories(F&I)
For 33kV SF6 CB
a) Operating Mechanism
b) Trip Coil for 33kV CB
c) Closing Coil for 33kV CB
d) Spring charging Motor
e)SF6 gas density monitor
f) Set of all Gaskets along with sealing agents
33kV, 25kA, 1250A Isolators Contact (01male, & 01 female=01 set)
33kV, 400-200/1-1A, 2-Core Single Phase CT complete with all fittings and accessories including Terminal connectors (0.2 class, live tank type)
33kV Lightning Arrester
Numerical Backup Relay @30% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Master trip Relay @ 10% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
SF6 Gas Cylinder
Bay control unit @ 30% on 33kV Feeder Control and Relay Panel (Simplex Type) suitable for integration to Siemens SAS
Clamps & Terminal connectors(F&I)
(a) CT Terminal Clamp (Panther)
(b) LA Clamp (Panther)
(c) Isolator clamp (Panther)
(d) CB Terminal connector (Panther)
Description of Work / Item(s)
Amount
Erection of mounting structure as required, including construction of foundation structure (including supply of all materials, labour, excavation etc.)
33kV SF6 Circuit Breaker
33kV Isolator
33kV Post Insulator
Erection, Testing and commissioning including laying of control cables and equipment earthing as required
33kV SF6 Circuit Breaker
33kV Isolator
33kV Post Insulator
Installation of Earthing System
Installation of earth electrode for LA with test links including construction of covered earth pits.
Construction of extended earth mat using GI flats and connection to risers for equipment earthing as directed.
Construction of Cable trench & slab. (including supply of all materials, labour, excavation etc.)
b) D Type
Switchyard PCC and Gravelling
Providing 80mm thick PCC base in prop 1:4:8 as per drawing & specifications including supply of all materials and labour.
Providing switchyard gravelling (100mm thickness) levelling etc as per directive of site engineer.
Installation and commissioning of the C&R panel
Installation in KIOSK, including testing and commissioning of C&R panel.
Integration of C&R panel into existing SAS including Testing and commissioning
Description of Work / Item(s)
Amount
Part A:Civil Works
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in?charge. All kind of soil
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 2.6.1. All kinds of soil
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and truts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu?ral sources : graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
250mm AAC Block work with common burnt clay machine moulded perforated F.P.S. (non modular) bricks of class designation 12.5 conforming IS : 2222 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand).
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
250mm AAC Block work with common burnt clay machine moulded perforated F.P.S. (non modular) bricks of class designation 12.5 conforming IS : 2222 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). 6.30.2 Above plinth level upto floor V level
12 mm cement plaster of mix : 13.1.1 1:4 (1 cement: 4 fine sand)
12 mm cement plaster finished with a floating coat of neat cement : 13.7.1 1:3 (1 cement : 3 fine sand)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (a) 75 x 6 mm (wt @3.53 kg/m) Flats @2000 mm c/c in cable trenches (b) 5 mm thick sheet (wt 39.25 kg/m2) ( c) ISA 50 X 50 X 5 @3.8 Kg/m through out the trench in both side
Providing,fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 63mm x 38mm x 2.5mm section of approved brand with door style of size 50mm x 45mm x 2.0mm, top rails 50mm x 45mm x 2.5mm, middle rail 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels.
Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorptions ? 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge.
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 26.26.1 With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 18.7.1 15 mm nominal dia Pipes
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.83.2 Two coats
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Part B : Electrical Works
Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor Penta/Gold medal /Kolor kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover ,ceiling rose (Anchor/Gold medal /Kolor kany.Kom / Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. 1 Long point up to 10.00 metre. Length. = 4 No's
2 Medium point up to 6.00 metre. Length. = 5 No's
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.2 With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in flat 19 mm ISI marked casing 'n' capping system. For AC (in meters) = 20 m
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 32.1.4 4 Core A2XWY A2XFY 32.1.4.3 10.00 Sq. mm.4 Core armoured U.G. cable Main supply = 50 m
Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB enclosure incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 13.3.1 ABB, Schneider MG, legrand, Hager make) 13.3.1.4 4 way single door = 1 No's
Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.5.1 Richa, Bentec, Adhunic, V-Guard make) 15.5.1.1 4 way SPN single door = 1 No's
Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.2.1 B Series (Schneider MG, legrand, Hager make) 16.2.1.1 16 Amp (For AC) = 2 No's 10 Amp (For Lights) = 2 No's Total = 4 No's
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.2 C Series (ABB, Schneider MG, legrand, Hager make) 16.3.2.1 40 Amp = 1 No's
Perforated RM30 MEDIUM DUTY RETURN FLANGE cable TRAYS WITH 2 NOS SPLICE, RM30 8 - M6 X GUTTER BOLT & NUTS UPTO 300mm AND 3 NOS SPLICE, RM30 12 - M6 X GUTTER BOLT & NUTS ABOVE 300mm including stand off bracket. 33.13.1.5 Size of tray (225) 3 x 21.69 = 65.07 Total = 65.07
33.13.2.5 Bend (225) = 2 No's
Supplying, installation, testing & commissioning of photo electronic Smoke Detector with mounting base complete in all respect.make:- APOLLO/Notifier/System Sensor or equivalent as approved by the Deptt.) = 2 No's
Part C : Air Conditioner Work
Supplying and fixing in position or as directed by Engineer in charge, 3 TR mega AC Split type,Centrifugal type compressor,Air flow rate is 1000 or above, with Big iron angle etc. whatever required with all other accessories including CPBC drain pipe, copper pipe with wire & insulation, control Unit etc. along with installation charges.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .