Executive Engineer DWSS Moga
Room No. 313 3rd Floor Jhelum Chenab Complex DAC Moga
Prov. and laying of pipelines, installation of House connections and minor repairs in village Kapure, Distt. Moga
2021_WB_66771_1
2021/WB/Kapure
Open Tender
Civil Works - Water Works
Item Wise
60 days
Village Kapure
Please refer Tender documents.
9 documents required · 9 mandatory
₹1
Yes
₹30,300
Yes
26 Aug 2021
10 Jun 2021
21 Jun 2021
10 Jun 2021
21 Jun 2021
10 Jun 2021
Amount
Provision for one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching powder solution/ Sodium Hypo Solution per hour under maximum delivery pressure upto 7 ka.cm 2 and suction lift not less than 1.5 m, as per DWSS standard specifications complete in all respects has been made in this estimate.
Repair of existing OHSR of capacity 100 cum complete in all respects as per analysis attached.
Painting angle iron pickets with angle 40mm x 40mm x 6mm including cost of paint complete in all respects.
Repair of existing outlet sluice valve chamber including B.B. , plastering and pointing etc. complete.
Repair of masonry gate pillar including repair , painting and writing of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-4 complete in all respects.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge). (CSR item 28.27)
Class PN-1 as per ISI 150mm i/d Sluice Valves flanged
Repair of leakages in Existing pvc pipe lines including excavation, Bailing out water, D joint & re-filling, etc. complete in all respects (As per Analysis)
90 mm o/d pvc pipe
Repair of Cement Concrete 1:2:4, Foot Path inside water works as per standard Drawing D-7 & Analysis A-10.
Deduct credit of old sluice vlaves
Minor repair in existing household connection (by Providing & fixing washer (electric welded) in the 15mm union on existing water connection etc.), Where water connections were installed by consumers, but not as per DWSS specifications.(Analysis attached)
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE/GI pipe lines 15mm i/d=4.50 mtr, (2.50+2.00 mtrs)including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 10mm i/d GM ferrule as per IS: 2692 and 3" i/d uPVCclamp and C.I. Bib cock complete. (As per analysis)
New Household Connections proposed On Existing / Replaced Pipeline
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE/GI pipe lines 15mm i/d=4.50 mtr, (2.50+2.00 mtrs)including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 10mm i/d GM ferrule as per IS: 2692 and 3" i/d uPVCclamp and C.I. Bib cock complete. (As per analysis)
New Household Connections on new pipe line
Providing, Laying, fixing & jointing of PVC Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Tranches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including excavation & back filling complete as per specifications for more than 3 mtr street width. (CSR item 28.2, 28.13 & 28.18)
PVC Pipe Line 63mm o/d 6 kgf/sq.cm
PVC Pipe Line 90mm o/d 6 kgf/sq.cm
PVC Pipe Line 110mm o/d 6 kg.f/sqcm
PVC Pipe Line 160mm o/d 6 kg.f/sqcm
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & inserting sheet, all carriage complete (with the approval of Engineer-in-charge) Class PN-1 as per ISI (CSR item 28.27 (A)
100 mm i/d Sluice Valve flanged
150 mm i/d Sluice Valve flanged
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. (cSR item 28.66)
Size (0.60 x 0.60 mtr)
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Dismantling of metallic road with bituminous coruse 50 to 75 mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respacts as per analysis A-26. NOTE:- Contractor shall quote rates only for dismantling mattle road and back filling with excavated earth, fully compacted. The restoration of the mattled road to its original condition will be done by the concerned department i.e. PWD (B&R)/PMB/Pnnchayti Raj.
Connection of new pipe line with existing pipe lines including excavation, Bailing out water, D joint & re-filling, etc. complete in all respects.
Providing & fixing MS Sign Board as per standard size of DWSS as per analysis A-24 & Drawing D-20
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .