Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹43.9 L+₹74,562.40 (1.73%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹46.9 L+₹3.7 L (8.55%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Mar 2022, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
SPECIAL REPAIRS TO BLDG NO SP3 SUGAR SHED SP1 DAL SHED PROVISION OF STORE SHED AT 55 COY AND SEWAGE LINES NEAR BLDG N0.P20 25A ME LINE OF 512 ABW UNDER AGE BR I C OF GE CENTRAL KIRKEE.
2022_MES_510264_1
8589/E8 OF 2021-2022
Open Tender
Civil Works
Item Rate
150 days
55 Coy and 512 ABW
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹90,000
Yes
29 Mar 2022
24 Feb 2022
25 Mar 2022
24 Feb 2022
23 Mar 2022
11 Mar 2022
24 Feb 2022 - 10 Mar 2022
Amount
B/R WORKS
Demolition of brick/stone work of any description of any size built in cement mortaretc,complete all as specified and as directed.
Walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in (CM 1:6) complete all as specified and as directed.
Pre cast cement concrete solid block masonry with solid block of the grade C-1, (1:3:6) set in CM (1:6) complete all as specified and as directed.
Taking down cement plaster on brick or stone walls or concrete surfaces etc at any position including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
20 mm thick rendering in CM (1:4) over stone masonary surfaces finished even and smooth without using extra cement complete all as specified and as directed.
20 mm thick rendering in CM (1:6) in two layers over stone masonary surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Preparation of new decorated plastered or unplastered surfaces of wall and applying two coats of cement base paint (white or tinted) over a coat of alkali resistant primer complete all as specified and as directed.
Preparation of plastered or unplastered old decorated surfaces of walls including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of cement base paint (white or tinted) complete all as specified and as directed.
Preparing new plastered wall surfaces by applying 3mm thick wall care putty to get smooth and even surfaces as directed and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
Preparing old plastered wall surfaces by applying 3mm thick wall care putty to get smooth and even surfaces as directed and applying two coats of oil bound distemper complete all as specified and as directed.
Plain cement concrete type B-1(1:2:4) using 20mm graded crushed stone aggregate as in coping/benching/bed blocks and like including necessary form work complete all as specified.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling old corrugated or semi corrugated or plain AC sheets complete all as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws including dismantling old corrugated or semi corrugated or plain AC sheets complete all as specified and as directed.
Preparation of new steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified
Preparing of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applyinbg two coat of synthetic enamel paint of any tint complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Plain cement concrete (1:2:4), 25mm thick, type B-1, using 20mm graded crushed stone aggregate as in base leveling complete all as specified and as directed.
Vitrified Ceramic tiles (light shaded) 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in flooring with and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed.
Glazed ceramic coloured tiles as in vertical surface 450 X 300 X 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with and including 10 mm thick cement plaster (1:4) as backing coat complete all as specificed and as directed.
Demolition of cement concrete (reinforced) as in roofs, floors, beams, staircase landing, chajjas and similar suspended work chajjas, facia and the like complete all as specificed and as directed.
Demolition of cement concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and as directed.
Plain cement concrete, (1:4:8), 100 mm thick, type D2 using 40 mm graded granite stone aggregate as in sub base complete all as specificed and as directed.
Machine cut mirror polished Kota stone slab flooring 20-25mm thick over and including 15mm thick cement screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
Machine cut mirror polished Kota stone 20-25mm thick as in riser of steps, skirting,dado and pillar laid over and including 10mm thick backing coat in CM(1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing, complete all as specified and as directed.
75mm thick Plain Cement concrete (1:3:6) Type C-2 (using 40mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement complete all as as specified and as directed by Engr-in-Charge.
25mm thick crushed stone dust/stand filling under floors or in cum foundation including watering and consolidation complete all as specified and as directed.
Coloured Machine pressed glossy finished precast concrete interlocking paver blocks of any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigment laid over sand cushion complete all as specificed and as directed.
Dismantling wall and ceiling boards (fiber,pulp,insulation,etc) or insulation boards/slab any thickness including cover fillets complete all as specificed and as directed.
E-board 'Everest' make 600x600x4mm thick white prelaminated sett embossed reinforced designer ceiling board tiles of approved texture at all height laid on Hot dipped Galvanised iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick GS sheet and of size 24x32x3000mm and spaced at 1200mm centers securely fixed to the structural soffits by approved hangers at 1200mm maximum centers. Hangers of GI wire 4mm dia to be fixed by approved rawl plug, level and justers and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall. Flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runners at 600mm center to form 1200x600mm modules cross tee longer than 600mm to be supported independently. 600x600mm modules to be formed by fitting 600mm long cross Tee centrally between the 1200mm cross tee. Tee, Perimeter wall angle shall be of 0.45mm thick GS sheet of size 19x19mm and 300mm long of white colour including taking down wall/ceiling boards(fibre, pulp insulation etc) or insulation boards any thickness including fillets complete all as specified and as directed.
Taking down chowkats and frame area n.exc 1.5 Sqm each of any type including shutters without taking off shutters from the frame and removing from site complete all as specified and as directed.
Taking down shutters of any description area exc. 1.00 sqm but .exc.2.00 sqm each
40 mm thick plain framed panelled factory made door shutters (two panels) with lock rail and panel of 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed by Engineer-in-Charge.
100 mm long cold rolled mild steel heavy weight, but hinged for welded to iron door shutter and frames complete all as specified and as directed.
Aluminium powder coated window sliding type (3 track) with frame size 100x35x1.2mm thick and shutter frame size 39.40x17.70x1.2mm thick with two glass shutter and one wire mesh shutter including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading screws with and including 4mm thick plain float glass and 0.36mm dia apperture 1.4mm stainless steel wire mesh and fittings etc and making good the jambs and painting with paint should match with the existing suface complete all as specified and as directed.
Rolled mild steel framed work such as grills, grating etc with ends bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed.
Preparing new or previously untreated wooden surfaces of any description not otherwise described over 10cm width or girth and applyinbg two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
Preparing of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applyinbg two coats of synthetic enamel paint of any tint complete all as specified and as directed.
Stainless steel fancy type Curtain rod 25 mm including SS brackets, decorative khobs with all necessary fittings such as rawl plug screws complete fixed in repairs all as specified and directed.
Excavating in trenches,n. exc 1.50m wide and1.50 m in depth, for foundation, etc n. for shaft, wells, cesspits, manholes, pier holes etc exc 10 sqm on plan and n. exc. 1.50 m in depth and getting out in soft disintegerated rock all as specified and directed.
Fly ash bricks , straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and as directed.
Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:4) complete all as specified and as directed.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:6) complete all as specified and as directed.
Pressed steel frames made of 1.25 mm thick MS sheet size 125 X 60mm for doors, ventilator with double rebates including necessary fixing lugs ,hinges, lock strike plate etc including providing PCC 1:2:4 type B1 (using 20mm graded stone aggregate) to fill the frame & making good complete all as specified and as directed.
300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
Aluminium anodised barrel tower bolt 150 mm long of extruded section with fixed complete all as specified and as directed.
150mm size Extruded aluminium alloy handles fabricated type anodised complete all as specified and as directed.
75mm thick Plain Cement concrete (1:3:6), type C-2 (using 20mm graded stone aggregate) as in plinth protection, surface finished even and fair without using extra cement complete all as as specified and as directed
Machine cut cudappah stone slab 20-25mm thick a over screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-Charge.
Hard core of guage n.exc. 63mm deposited spread and levelled, laid in layers n.exc. 15cm thick, watered and rammed to a true surface using broken boulders all as specified and as directed.
Morrum/Red bajri, spread, rolled and consolidated to gradient and camber required all as specified and as directed.
Preparation of new plasterd or unplasteres surfaces of walls and applying two coats of oil bound emulsion distemper over 3 mm thick wall puty and over a coat of primer complete all as specified and as directed.
Preparation of wall surfaces of any description including brooming down with steel wire brushing, scrapping down smoke soot's , moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima Protek Asianpaints, Nerolac excel top guard, Berger weathercoat long life 10 or equivalant brand as specified in CA complete all as specified and as directed.
Rolled mild steel as in roof trusses(framed), trussed , purlins ,crane gantries ,rails and fastenings and heavy bracket farming (beam ,tee , angle , channel or flat section)including distance pieces,cleats etc Fe 410-A(Gde E250) quality A complete all as specified and as directed.
Rolled section as in framing for cladding ,glazing and the like fixed with angle cleats and connecting plates,including flat iron wind tie etc.Fe 410-W(Gde E250) quality A complete all as specified and as directed.
0.5mm thick pre painted plain, galvanised, mild steel sheeting as in ridges,hips, valley gutters, drip and staright flashings(length and girth as fixed) with grade zinc coating 2785 complete all as specified and as directed.
Preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed.
Demolition and breaking up of 150 mm to 450mm dia drain pipes(Salt glazed stone ware, AC or Reinforced cement concrete) with bed concrete set in cement mortar including removing debries to a distance not exceeding 1 KM all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard / dense soil etc complete as specified as directed.
Removing the excavated material to a distance n.exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete as specified as directed.
Reinforced Cement Concrete pipes, class NP2, of 200mm dia laid in trenches and jointed complete with collars all as specified and directed.
Plain Cement Concrete, (1:3:6), type C2 using 40 mm graded stone aggregate as in bed to drain pipes including forming cradles for PVC(SWR) / RCC pipes after they are laid and tested suitable for 200mm dia bore pipe complete all as specified and as directed
Cutting into existing manholes for connecting new drains by cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete (1:2:4)type B-1 smooth finishing & making good to pipe as per existing by rendering & reforming benching as required for 200/300mm bore pipe complete all as specified and directed.
Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM(1:4) finishing the surfaces even and smooth with out using extra cement mixed with approved water proofing compound complete all as specified and directed. NOTE :- WPC will be measured and paid separately.
Supply only integral liquid water proofing compound all as specified and as directed.
Precast Reinforced Cement Concrete (1:2:4), type B1, using 20mm graded stone aggregate as in cover slabs of man hole set in CM (1:6) complete all as specified and as directed.
TMT steel bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitrerd/stopped ends etc., complete all as specified and directed.
Plain Cement Concrete (1:2:4), type B2 ,using 40mm graded stone aggregate as in surfaces channel and drains and the like including weathering, slightly rounded or chamfered angles and thoroughly complete all as specified and directed.
E/M WORKS
Taking down copper/aluminium point wiring (light, fan, socket or power ) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately ) and making good disturbed surfaces of walls, floors, etc
Point wiring with 1.5 sq.mm size PVC insulated unsheathed 1100 volt grade single core stranded FRLS (multithreaded) copper conductor cable drawn into and including PVC casing caping of suitable size with all fitting and accessories with sunk type pressed steel terminal/PVC surface type boxes of 1.6 mm with 3 mm thick laminated sheet top cover concealed/surface in walls complete for Provn of switches/socket/fan regulators including one continuous run of PVC insulated (green colour) 1.5 sqmm multi stranded FRLSH copper conductor cable as earth wire and connected to common earth dolly for the following:- (a) One light/fan point controlled by one, one way 5 Amps switch.
(b) One ceiling fan /Exaust fan/wall mounted fan point controlled by one switch.
(c) One three pin 5 Amps socket outlet,with cables 1.5 sq.mm size on independent board.
(d) One three pin 5 Amp socket outlet, with cables 1.5 sq.mm size on same board.
All as per Sl Item No 2.002 above but with 2.5 sq.mm size PVC insulated and unsheathed 1100 volt grade multistranded FRLS copper conductor cable for 3/6 pin socket outlet 15 Amps on one independent board.
Switch Piano, flush type, 5 Amps, 240 Volts single pole, one way with ISI marked complete all as specified and as directed.
Ceiling rose, surface bakelite type, 65 x 50 mm, 2 to 3 terminals all as specified and as directed.
Switch socket combination 3 & 2 pin, 5 Amps, 240 Volts, flush type multipurpose controlled by one switch all as specified and as directed.
Switch socket combination 2 in 1, 3 pin and 2 pin, 5 and 15 Amps flush type, universal complete all as specified and as directed
Stepped type electronic fan regulator for ceiling fans including necessary connections of capacity 100 watts 240 Volts complete all as specified and as directed
MCB DB, SPN 8 ways, 240 Volts with 200 Amps rated busbar, double door for housing MCBs all as specified and as directed.
MCB single pole and neutral 6 to 32Amps, 240 Volts,10 KA breaking capacity ''C'' curve all asper Legrand Cat part no-4086-9 to 4086-17 or techno commercially equivalent of schneider/ABB complete all as specified and as directed.all as specified and directed.Make-cat part no- of Legrand or equivalent of schneider/ABB
MCB single pole 6 to 32Amps,240 Volts,10 KA breaking cap ''C'' curve all as per Schneider Cat part No-A9N1906C to A9N1P32C or techno commercially equivalent of Legrand/ABB all as specified and directed.
LED tube light fitting, 20 watt, CDL, 230 Volts, 4 feet long, Trim Linea complete with all accessories internally prewired and including connecting upto ceiling rose with 0.5 sq.mm twin core copper flexible conductor cable including LED lamp and mounting casing box 2 Nos + E12 any type all as per Crompton Cat part No. LCTLN-20-CDL or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Lamp holder, Insulated body with back plate suitable for batten fittings complete all as specified and as directed.
LED lamp 9/12 watt, CDL, E-27 230v PF-0.95(min) complete all as specified and as directed.
LED building security light 15 watt, 230 Volts, AC with pressure die cast aluminium housing and heat resistace complete with electronic driver including fixing accessories internally prewired and incl connecting upon new brackets complete all as specified and as directed.
Earthing complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 3 mtr long burried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanised steel earthing lead of 4mm dia all as shown in Electrical plate No-2 of SSR Part I , connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
Socket flush type 6 Amps, 5 pin, 230 Volts including dismantling unserviceable one all as specified and as directed.
MCB distribution board, IP 43 protection, double door, metal enclosure,SPN 230 Volts, 4 way all asper Legrand Cat part no-5076 11or techno commercially equivalent of schneider/ABB complete all as specified and as directed.
Exhaust fan 380 mm sweep metal body 1500 rpm incl complete fittings/making hole on wall all as per Havells Cat part No-Vent air -DS or techno commercially equivalent makes specified in PS all as specified and directed.
LED building security light 15 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sq.mm three core copper flexible conductor cable, One GI medium grade 20/25mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener all as specified and as directed. Make-Compton/philips/Bajaj
Energy saving ceiling fans, 230 Volts, 26 Watts, single pole, 1200 mm sweep, high speed of approved colour with remote control and two years warranty certificate from the manufacturers, with latest BEE five star rating and BLDC technology all as per Havells Model No :- Efficiencia Neo (BLDC 26W) or techno commercially equivalent models specified in PS complete with down rod and GI hook with welding work, wire connections from ceiling rose to ceiling fans, with complete accessories including writing of MES No with unit name on ceiling fans using approved stencil with synthetic enamal paint complete all as specified and as directed.
PVC insulated, PVC sheathed twin flat core 1100 volt grade,10 sq.mm aluminium stranded conductor (incl PVC conduit/wire guard where required ) all as directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts sgrade, cross sectional area 16 sq.mm, 4 core laid in trenches/ fixed on wall / poles including taking down the existing complete all as specified and as directed.
Excavating in trenches, n. exc 1.5m wide and n.exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches n.exc. 1.5m wide and n.exc. 1.5 m in depth; for foundation, etc. and getting out in soft/ disentigrated rock complete all as specified and as directed.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard / dense soil etc complete as specified as directed.
Removing the excavated material to a distance exc. 50m but n. exc. 100m and depositing where directed at a level n. exc. 1.5m above the starting point.
Sand cushioning in layers for cables in trenches / ducts for cable using dry river sand including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
LT Panel, outdoor type, CPRI approved makes as specified in PS conforming to relevant IS, factory made with 3mm thick CRCA sheet duly powder coated and suitable size to accommodate following accessories / fittings with suitable size of copper wire and angle iron frame including supply and fixing following accessories compartmentize in consturction to accomodate incoming/outgoing cables and connecting copper wire, foundation for fixing angle iron frame for panel including supply, install, testing and commissioning comprising of the following :- (a) TPN MCB 63 Amps- 01 No. (b) SPN MCB 40 Amp-03 Nos. (c) MCB SP 6-32 Amps 10 KA. (d) Indication lamp RYB - 01 Set. (e) Ammeter and voltmeter- 01 Each. (f) Aluminium Bus bar. (g) one digital timer (h) one power contactor MNX 32 Amps 240 Volts all as specified and directed. Make of Panel : L&T or techno commercially equivalent as specified in PS.
Shri Sant Cosntruction
DARSHAN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .