| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | Admitted-Finance |
| 2 | Admitted-Finance 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | Admitted-Finance |
| 3 | Admitted-Finance BASEMENT PLOT NO 17 4657 21 ANSARI ROAD CENTRAL DELHI NEW DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | Admitted-Finance |
Tender Value
₹45.9 L
EMD Value
₹91,700
Closing Date
23 Sept 2024, 6:00 pmClosed
GE (South West)
GE (South West) New Delhi-03
REPAIRS TO ROOF TREATMENT OF ABC PARKING OF MBC AND REPAIR/ RENOVATION OF CONFERENCE HALL AT RRC GHITORNI (RESTRICTED AREA) UNDER GE (SOUTH WEST) NEW DELHI-03
2024_MES_667136_1
GE/SW-39/2024-25
Limited
Civil Works
Item Rate
180 days
GE (South West) New Delhi
Class D Category a(i)
7 documents required · 7 mandatory
₹500
GE (South West) New Delhi
₹91,700
Yes
25 Sept 2024
2 Sept 2024
25 Sept 2024
2 Sept 2024
23 Sept 2024
16 Sept 2024
Amount
Taking down cement plaster of any description, any type, from concrete, brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc. & removing debris out side MoD land complete all as specified and as directed.
Dismantling brick tiles or terracing tiles, single layer on roofs slab with & including screed bed complete & taking down all demolished material at Ground level & removing from site etc complete. Note: Rate includes cleaning of roof slab without damaging of existing roof treatment complete.
Demolition of Mud on roof slab, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof & grass etc complete all as specified. Note:- (i) Rate including for breaking up and taking up or down mud phuska with all necessary precautions for the protection of existing building and keep down dust/debrises without any nuisance. (ii) Rate included for taking down all demolished material at ground level. (iii) Rate includes the cleaning of roof slab without disturbing of existing roof treatment
Demolition of Concrete of any description and in any position not otherwise specifically provided for such as PCC as in kerbs, PCC padding as on roof slab any thickness with plastering etc including taking down demolished material at ground floor complete all as specified and as directed. Notes (i) Rate including for breaking up and taking up or down PCC padding with all necessary precautions for the protection of existing building and keep down dust/debrises without any nuisance. (ii) Rate included for all necessary services for ease of work for ground plus 3 storey building like Mechanical Tools and Mechanical suspended platform for height up to 15 m)
Removal of all debris obtained from srl item No 3 & 4 upto 15 Km lead outside the Cabinet Sectt Bldg premises and dumped as per order of Delhi Govt/ Local civic body/ NGT as applicable including loading, dumping and leveling complete all as specified and as directed.
M&L plain cement concrete, type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in PCC sub base, roof padding, Gola, etc including cleaning the surface by wire brushing complete all as specified and as directed.
M&L 10 mm thick rendering in cement mortar 1:3 on brick or stone masonry wall surface & roof slab, finish even & smooth without using extra cement, mixed with water proofing compound complete all as specified and as directed. (Note: WPC shall be measured & paid separately under respective item of this Schedule.)
Providing water proofing treatment using 3mm thick APP (Atatic poly propylene) of weight not less than 3.0 Kg/Sqm, modified bituminous membrane re-inforced with non woven polyester mat of weight 150 gms/Sqm as centre core and without multiple layers of polythene finished on top and bottom with 7 micron thick flammable polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane over and including a coat of bituminous primer @ 0.25 kg / Sqm over roof and finishing the treatment with one coat of bitumen of grade 85/25 @ 1.2 Kg per Sqm over APP membrane (An overlap of 75mm & 100mm shall be provided on sides & ends respectively) complete at upto ground plus three storied building all as specified & as directed. Notes:- (i) Irrespective of lap the net covered area shall only be measured and paid. (ii) The quoted rate shall deemed to be inclusive of primer, APP membrane & bitumen coat. (iii) The quoted rate shall deemed to be inclusive of one coat of bitumen of grade 85/25 @ 1.2 Kg per Sqm over APP membrane.
M&L for coloured cement concrete roof tiles area of tiles exceeding 0.11 sqm but not exceeding 0.18 sqm and 22-25 mm thick laid in roof over and including 15mm thick screed bed in cement mortar 1:4 and pointed in epoxy tile grout of matching shade complete all as specified and directed.
M&L for 15 mm thick rendering on brick wall in cement mortar 1:4 finished even and fair including mixing of water proofing compound as per manufacturers instruction complete all as specified and directed. (Note: WPC shall be measured & paid separately under respective item of this Schedule.)
Supply only Liquid water proofing compound (ISI marked) complete all as specified and as directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces etc all specified on external surfaces.
Demolition of brick work built in cement mortar of any description, including all quoins, arches, pillars, etc complete all as specified and as directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan not exc 6 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed.
S&F as in repair aluminium sheet 0.71mm thick fixed with screws/ fastners and moulding (at crumple joint) complete all as specified and directed.
Dismantling of existing walls and roof without disturbing the structure of conference hall complete all as specified and as directed.
Supply and Fixing of 50mm thick Puff insulated wall panels be made out of PPGI Profield sheet (0.4mm) PPGI plain sheet (0.4mm) in side between 40mm thick composite puff panels duly secured using screw with epdm washers and further sealed with silicon ruuber for added water protection complete all as specified and as directed. Make : M/s Porta Cabin Engineers Pvt Ltd/ Shree Porta Builders Pvt Ltd/ M/s Startrek Structures/ M/s Makeover Interiors/Genesis India/Kanchan Enterprises
Supply and fixing of 60 x 30 mm thick insulated roof panels be made out PPGI profield sheet (0.4mm) PPGI plain sheet (0.4mm) in side in between composite puff panels duly secured using screw with epdm washers and further sealed with silicon rubber for added water protection complete all as specified and as directed. Make : M/s Porta Cabin Engineers Pvt Ltd/ Shree Porta Builders Pvt Ltd/ M/s Startrek Structures/ M/s Makeover Interiors/Genesis India/Kanchan Enterprises
Providing and fixing of Powder coated Aluminium Single Leaf Door of size 1.00 x 2.10 mtr with required hardware and accessories complete all as specified and as directed.
Providing & fixing of 2 Track Bombay Sliding Window of size 1.20 x 1.20 mtr with required hardware and accessories complete all as specified and as directed.
S&F Vitrified Ceramic tiles of any colour 8 mm thick (square/ rectangular) double charged, area of each tiles not exceeding 0.36 sqm, in floors/ wall as in skirting etc. fixed with adhesive of fevimate-XL resin mortar Make- Pidilite or equivalent as approved by GE including dismantling of existing flooring complete all as specified & directed by Engr-in-Charge.
S&F as in repair mineral fibre ceiling boards 15 mm thick, 600 mm x 600 mm size including grid 25 x 25 x 1.6 mm thick GI powder coated wall angles and 25 x 35 x1.6mm size T runner suspended at 1200 mm centre to centre and cross T runner of 25 x 35 x 1.6mm size suspended at 600 mm centre to centre supported by 4 mm dia GI wire from roof/ slab including wall angle and T with interlocking arrangement as required for framing grid suitable for module size 600 mm x 600 mm ceiling etc complete all as specified and directed. (Make : Armstrong RH Dune 95 or equivalent of Aerolite/Dexun/Anchor)
S&F as in repair sheer dimout blinds with cassette complete with chain operation complete all as specified and directed by Engr-in-Charge. (Make : Vista/ Marvel/ Hunter Douglas)
M&L for Point wiring with 1.5 sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 volts grade, IS -694 marked, with multi stranded copper conductor and earth continuity copper conductor cable of same size as in phase/neutral and connected to common earth dolly drawn through and including rigid PVC conduit of suitable size alongwith fittings and accessories, fixed /laid/concealed in walls/ceilings including cutting chases and making good to walls, floors and also incl suitable modular bottom sunk type procced steel terminal box and suitable modular top cover with frame of suitable modules all as directed by Engr-in-Charge for the following:-
(a) One light/ fan point controlled by one, one way switch.
(b) One three pin socket outlet 5 Amp controlled by one, one way switch on same board
(c) One three pin socket outlet 5 Amp controlled by one, one way switch on independent board
M&L for Point wiring with 4.0 sqmm, single core ,PVC insulated, unsheathed FRLS cable, 1100 volts grade, IS -694 marked, with multi stranded copper conductor and earth continuity copper conductor cable of 4.0 sqmm connected to common earth dolly drawn through and including rigid PVC conduit of suitable size alongwith fittings and accessories, fixed /laid/concealed in walls/ ceilings including cutting chases and making good to walls, floors etc, and also incl suitable modular bottom sunk type procced steel terminal box and suitable modular top cover with frame of suitable modules all as directed by Engr-in-Charge on independent board.
Supply and fix switch modular 6 Amps 1 module 230 Volts one way.
Supply and fix Modular switch 1 way 16 Amps 1 module 230 Volts.
Supply and fix modular socket , 6 Amp 2/3 pin combined 230 Volts
Supply and fix modular socket , 16 Amp 2/3 pin combined 230 Volts.
S & F LED Light fitting 34 watts 2x2 Ultra modern recess mounting luminaire suitable for ceiling complete with separate electronic driver & high brightness SMD LEDs, 34W LED 4000K lamp type. All as directed by Engr-in-Charge.
S& F LED Mirror light fitting fancy type with high out put diffuser 10 Watt, 220 Volt, AC decorative type with driver including connecting up with three core flexible copper conductor cable suitable size all as directed by Engr -in-Charge.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps cap etc. as requiredand directd by Engr-in-Charge.
Supply, install, testing and commissioning wall mounted fan made of sturdy Engineering plastic complete withall accessories , voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 400mm 3 blade, single phase, all as directed by Engr-in-Charge.
S & F Exhaust fan steel body single phase AC 230Volt, 230 mm sweep with blades, frame, shutters and louvers all as directed by Engr-in-Charge.
S&F sub main wiring with two runs PVC insulated unsheathed FRLS stranded copper conductor cable of size 4 Sqmm alongwith one run of PVC insulated unsheathed stranded copper conductor cable of size 4.0 sqmm as earth wire connected to earth dolly fixed on surface of wall/ceiling/in existing concealed conduits,including cutting chases and making good to walls, floors etc, complete all as specified and directed. Note:- Two run of 4.0sqmm copper conductor cable,one run of 4.0sqmm copper cable and one run of PVC conduit pipe shall be measured as one unit length.
M&L for telephone point wiring with cable and accessoreiest complete all as specified and directed
M&L for Ehternet point wiring with accessores complete all as specified and directed. Note: Cable will be provided by the USER.
S&F Metal clad enclosure with plug and socket 20 Amp with one MCB single pole, 20 Amps 240 volts. all as specified. For Ac s and Geyers.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25X4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover etc.
S&F MCB SP, 240 Volts, AC, 6 to 32 amps, breaking capacity 10 KA, 'C' curve and connection by using suitable copper lugs complete all as specified.
Supply and fixing of smoke Detectors Complying with and type certified to EN - 45 Addressable type with base smoke detector Photoelectric/ Optical with self built intelligence as per IS: 11360
Supply, fixing ridig PVC conduit of 25 mm incliusive of all tees,bends elbows reducers, bell mouth tube ends and fixig aaccessories suc as couplers lock, nuts, saddles, pipe hooks etc on the dia with all accessores such as bends, tee junction boxes etc
Supply,fixing ridig PVC conduit of 20 mm incliusive of all tees,bends elbows reducers, bell mouth tube ends and fixig aaccessories suc as couplers lock, nuts, saddles, pipe hooks etc on the dia with all accessores such as bends, tee junction boxes etc. Note : LAN cable shall be provided by the user dept.
S&F in replacement of sheet metal enclosure MCB DB double door TPN 12 way complete all as specified and directed.
Supply & Fixing in replacement of sheet metal enclosure MCB DB double door TPN 4 way complete all as specified and directed..
Supply Installation Hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary of capacity 2.0 TR .all as dirccted by Engr-in Charge.
S&F in repairs and replacement wall mounted indoor Voltage Stabilizer automatic operation single phase and designed for input variation between 170 V to 250 Volt with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 5 KVA.
Supply, install,commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase, 220 V, 50HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS - CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening size 70"X78" all as specified and directed by Engr-in-Charge.
R R Associates (BID ID -3097266)
VINAY ENTERPRISES (BID ID -3107512)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .