| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance NO 73 11TH CROSS SWIMMING POOL EXTN MALLESHWARAM BANGALORE KARNATAKA 560003 | BENGALURU URBAN | KARNATAKA | 560003 | Admitted-Finance |
Tender Value
₹4.8 L
EMD Value
₹9,655
Closing Date
23 Mar 2023, 4:00 pmClosed
EXECUTIVE ENGINEER (E)
BSNL Electrical Division-II, WMS Compound, 47th Cross, 9th Main, 5th Block, Jayanagar, Bengaluru 560041
Providing repairs supplying spares for day to day maintenance of Electrical Installation and fans at Staff Quarters and Guest House WMS COMPLOUND JAYANAGAR BANGALORE
2023_BSNL_148707_1
69/2022-2023/BSNL/ED-II /BGL
Open Tender
Electrical Works
Item Rate
60 days
WMS COMPOUND JAYANAGAR BENGALURU
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer (Cash), HQ, BSNL, BGTD
₹9,655
30 Mar 2023
14 Mar 2023
25 Mar 2023
14 Mar 2023
23 Mar 2023
14 Mar 2023
14 Mar 2023 - 23 Mar 2023
Amount
REPAIRS TO EI AND FANS
SITC of 25 litres capacity storage type geyser suitable for 230 volts, 50Hz AC supply with 18 inch long cold water inlet & hot water outlet hose pipes etc as reqd. (M/s Racold CDR DLX or SS Make)
S/F of gate light to suit the exisitng fautly fitting suitable for 230 volts, 50Hz, AC supply i/c removing the faulty gate light etc as reqd
S/F of 3Ampere electronic voltage stabilizer suitable for LED/Smart TV with low/high voltage cutoff, built in thermal overload protection, 4-6 seconds initial delay and suitable for input voltage range of 90 - 290volts, 50Hz AC supply etc as reqd. (Make :- V-Guard Crystal Plus or S/S Make)
Providing repairs to exisitng 25 litres capacity storage type geyser by replacing the following spares etc as reqd. (a)S/F of 2kw heating element coil for various make & model Geysers
(b)S/F of 2kw heating element coil for Racold make, ETERNO/TRG ECO model Geysers
(c) S/F of 9/11 inch long Thermostat suitable for 25 litres capacity varous make & model Geysers
(d) S/F of 9/11 inch long Thermostat suitable for 25 litres capacity varous make & model Geysers
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (a) 3x1.5sq.mm
(b) 3x4.0sq.mm
Supplying and fixing of following sizes of PVC casing & capping along with accessories in surface as required (a) 20mm x 12mm
(a) 25mm x 16mm
Supplying and fixing of 20mm dia of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (Make:- M/s.Anchor or SS make) (a) 5/6 amps switch
(b) 15/16 A switch
© 3 pin 5/6 A socket outlet
(d) 6 pin 15/16 A socket outlet
(e) Bell push
(f) 2 way 5/6 A switch
S/F of 20A switch with 20/10A combined socket outlet & suitable size box on surface of wall including interconnections etc as reqd.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (a) 10 amps one way switch
(b) 3 pin 6A socket outlet
Supplying and fixing 4 module Modular base & cover plate on existing modular metal boxes etc. as required.
S/F of 2 module 100W rotary stepped type electronic fan regulator on the existing switch box including connections etc. as required.
S/F of 100W single module rotary stepped type fan regulator in exsiting switch box i/c removing the faulty regulator etc as reqd. (Make:- M/s.Anchor or SS make)
Supplying and fixing 6A PVC batten/ angle holder including connections etc. as required
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole
(b) Double pole
(c) Triple pole
(d) Triple pole and neutral
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 25 A
Providing repairs to exisitng flourescent fitings by repalcing the faulty tube light and choke etc as reqd. (a) 36Watt Flouresent tube light
(b) 36 Watt Electronic choke
S/F of 4 feet long 20watt LED batten with LED tube suitable for 230 volts, 50Hz AC supply etc as reqd. (M/s. Crompton or SS Make)
S/F of 3 Watt foot lamp on exisitng Ms box i/c providing phenolic laminated sheet cover in the front etc as reqd.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
S/F of PVC gang box suitable to accommodate 2No's one way switch & 1No. 3pin 6A socket outlet etc as reqd.
S/F of PVC gang box suitable to accommodate 2No's one way switch & 2No's. 3pin 6A socket outlet etc as reqd.
Rewinding of ceiling fan motor with similar gauge enamelled copper wire i/c checking the faulty ceiling fan, dismantling, taking to workshop for repairs & reinstallation after rewinding etc as reqd.
Repair of ceiling fan motor by repalcing the 2no's bearings i/c checking the faulty ceiling fan, dismantling, taking to workshop for repairs & reinstallation after rewinding etc as reqd.
S/F of 6A switch with 6A combined 3 pin socket outlet & suitable size box on surface of wall including interconnections etc as reqd.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group A
S/F of 8/9W LED fitting for mirror light i/c removing the faulty fitting etc complete as reqd.
S/F 6W LED surface mounting fitting for staircase lighting i/c removing the faulty fitting etc complete as reqd.
SRI DHANALAKSHMI ELECTRICAL STORES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .