Loading…
Loading…
Tender Value
₹5.7 Cr
EMD Value
₹11.3 L
Closing Date
14 Jul 2026, 11:00 am
Similar tender results from the same govt authority in the past 3 years.
Construction of office cum Rest house at Nashik in connection with the Kasara - Manmad 3rd and 4th line (131Km) project under Bhusawal Division of Central Railway.
DyCECBSL-02-2026-27
DyCECBSL-02-2026-27
Open
10 Months
Nashik, Maharashtra
₹0
₹11.3 L
19 Jun 2026
19 Jun 2026
30 Jun 2026
B-Dismantling of exiating structure 254099.87 Below/P
C-Provision of Compound wall 3776982.43 Below/P
Hiring of machinery for minor miscellaneous works for short duration including 1 operator/driver, fuel, lubricants and consumable. The contractor shall arrange all statutory permits as required by rules and regulations prevailing in the area of work. Payment shall be made for actual working hours at site. JCB Backhoe Loaders 3DX Plus or similar with minimum 1.10 cum bucket capacity
Hiring of machinery for minor miscellaneous works for short duration including 2 operator/driver, fuel, lubricants and consumable. The contractor shall arrange all statutory permits as required by rules and regulations prevailing in the area of work. Payment shall be made for actual working hours at site. Hydra or similar tyre mounted Pick-n-Carry crane of 12T capacity for misc. works of handling of material
Provision of barricading with contractor's bamboos / ballies vertical post of 100mm dia. planted at every 2m interval, projecting at least 1.5m above ground level and driven firmly (minimum 0.5m) inside ground and including painting verticals & horizontals with red luminous 3 paints / strips at alternative bay on barricade. Barricades shall be maintained through out the execution of the work and shall be removed in workman like manner on completion of the work only after instruction of Engineer in-Charge. Note: (1) 60% payment shall be made on provision of barricading at work-site and balance 40% payment after removal of barricades. (2) The released bamboos / ballies shall be the property of the Contractor. With 3 horizontal bamboo / balli members of minimum 50mm dia. spaced equally Above/
Supply and using Cement at Worksite Ordinary Portland Cement 43 grade approved brands/makes Above/
G-Electrification works in connection with construction of proposed
Supply and concealing of rigid PVC conduits of 20 mm Dia (IVORY colour) confirming 11 to IS 9537/P3/1983 or latest (ISI marked) with wall thickness not less than 2.0 mm along with the all accessories and including cutting the wall / ceiling / chipping and re plastering distempered / painted as the case may be, the same in good condition as directed by Engineer in charge at site.
Supply of all materials required and single phase wiring by using 2 Nos. of 4.0 sq.mm 12 PVC insulated FRLS type flexible copper cable conforming to IS.No:694, 1100 V grade with 1 No. of 4.0 sq.mm flexible copper cable through the PVC pipe already laid. Color coding shall be followed as directed by Engineering charge at site (3 Nos. of 4.0 Sq.mm Copper cable wire shall be taken as 1 Mtr. for measurement purpose).
Supply and concealing of rigid PVC conduits of 25 mm Dia (IVORY colour) confirming 13 to IS 9537/P3/1983 or latest (ISI marked) with wall thickness not less than 2.0 mm along with the all accessories and including cutting the wall / ceiling / chipping and re plastering the same as good condition as directed by Engineer in charge at site.
Supply and wiring including termination by 3 nos. of 6 sq mm PVC insulated flexible copper cable conforming to IS.No: 694, 1100 V grade through the existing PVC pipe already laid, Color coding shall be followed as directed by Engineer in charge at site (3 nos. of 6 sqmm copper cable wire shall be taken as 1 m for measurement purpose)
Supply and concealing of rigid PVC conduits of 32 mm Dia (IVORY colour) confirming 15 to IS 9537/P3/1983 or latest (ISI marked) with wall thickness not less than 2.0 mm along with the all accessories and including cutting the wall / ceiling / chipping and re plastering the same in good condition as directed by Engineer in charge atsite.
Supply and wiring (3 Phase) including termination by 4 nos of 10.0 sqmm PVC 16 insulated fire retardant low smoke (FRLS) flexible copper cable conforming to IS No: 694, 1100V grade with 1 no of 14 SWG tinned copper wire through existing PVC pipes already laid. Color coding shall be followed as directed by Engineer in charge at site.(4 nos of 10.0 sqmm copper cable and 1 no of 14 SWG tinned copper wire shall be taken as 1 m for measurement purpose.)
Supply, erection, testing & commissioning of Industrial type metallic plug sockets 20A with 20 A MCB DP with 3x4 sqmm PVC insulated and sheathed copper conductor complete.:Erection
Supply, installation, testing & commissioning of single phase RCBO of 32A capacity, 30mA sensitivity with Metal enclosure.
Supply, erection, testing & commissioning of Lighting Circuit Board, Double Door 35 Powder coated with locking arrangement consisting AFDD with RCBO 32 A Combined 1P+N RCBO + AFDD Complete as I/C and 2 Nos x 1 A SPMCB, 2 nos x 2 A SPMCB, 2 Nos x 3 A SPMCB, 2 Nos x 6 A SPMCB & 3 Nos DP RCBO 16 A O/G Complete.:Erection
Supply, erection, testing and commissioning of THE MOST SILENT BLDC FAN WITH PREMIUM LOOK AND FINISH 1200 MM BLDC MOTOR AND REMOTE CONTROLLED CEILING FAN (PEARL WHITE).MAKE:-HAVELLS STEALTH AIR,USHA,ORIENT. (ACCEPTED MAKE HAVELLS):Erection
Supply & Fixing of Heavy Duty BLDC Air Circulator Fan 600 mm sweep, 1300 RPM, Watt 120-140, Wall mounting type should have speed adjustment, suitable to work on 200 260 V, Air Delivery conforming to IS2997/1964 Make Airzon, Havells, Bajaj, Atemberg or similar.
Supply, fixing, testing & commissioning of Efficio Exhaust Fan 200mm (8 Inches) | BLDC Motor | 20W | Low Noise | 1600 RPM | Ideal for Bathroom,Kitchen | Easy to Clean | 2 Years Warranty
Supplying and erecting midget type 3.0 litres instant type water heater of rustproof & shockproof ABS plastic body, high grade SS inner tank & 3kW heating element with corrosion & hard 54 water protection, with minimum 3 safety protections (i.e. thermostat & thermal function valve) complete with 6.5 bar pressure withstanding capacity 230/250V, 50Hz, A.C. supply with inlet b and outlet, with 3 core PVC flexible copper wire leads duly tested and marking sr. no. and date of erection complete
Trenching & refilling of LT/HT/ Various sizes of PVC / XLPE cables- Along the Road (Size - 900mm x 300mm)
Digging of cable trench 300/450 mm x 1000 mm in RCC/PCC/hard soil & refilling as per specification and requirement at the site.
Transportation, Laying, Installation, terminating, testing and commissioning of LT/HT cable of sizes 10 sqmm to 400 sqmm in existing trench, pipe or on structure.
Erection,testing and commissioning of cables other than trench i.e.Wall/Truss including clamp, GI wire and hardware
Supply & laying of GI pipe Class B, ISI marked under road /Clamping with erecting pole or wall as per technical specification & drawing for passing cable.
Supply and laying of RCC Hume Pipe of size 6"(150mm) dia 2 mtr. Length. :Erection
Supply, fabrication, laying welding and connection of GI Flat of size 25x3 mm from earth pit with GI nut Bolt suitable size.:Erection
Supply, erection, testing & commissioning of self contained drinking water cooler unit 78 energy efficient compressor IS mark suitable for operation on 230 V +10 % 50 cycle single phase Ac supply storage capacity 150 Ltr cooling capacity 150 Ltr/Hr complete in place of old one as per specification. :Erection
Supply, erection, testing and commissioning of 40 KVA online type UPS having three 79 phaseinput and three phase output, IGBT technology and withinbuilt isolation transformer 480 VDCincluding alteration to existing wiring withswitches, socket,changeover etc, if any,required at site forinstalling the UPS.Make APC, NUMERIC,
Supply, Erection , testing and commissioning of LT panel Outdoor type with closing 82 door powder coated consising of 1x250A 4P MCCB as I/C and 6 Nos x 63 A MCCB for O/G completev with Busbar, MF meer, seclector switch and indicating lamp with neutral and other accessories: Erection
Supply, erection,testing & commissioning of Chandeliers with LED Bulbs complete:Erection
Supply, fixing, testing, connecting and commissioning of 7.5 Watt or above LED 86 pendent light, compitable to Ceiling mounted/Darbari tent.Indoor decorative luminaries pendent light/Chandelier light as per interior design. After completion of the works all materials shall be deposited to the concern SSEs stores. Above/
H-PART-I- Supply installation testing and Commissioning of Telecom
Supply of GI pipe, inner dia. 100 mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. (Inspection by RITES)
Supply of RCC pipe half round of size 150 mm dia outer and 100 mm dia internal 1mtr long matching to IS No. 458/2003 amendment - 1 with Rev. 4. or latest. (Inspection by Consignee)
Supply of DWC HDPE pipe with one snap fit coupler and "O" ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver. 1.1 with Amd. 1 or latest. (Inspection by Consignee)
Supply of HDPE Telecom duct 50mm dia solid permanently lubricted inner dia 42mm. & wall thickness 4mm. with end plugs, coupplers, cable sealing plugs and duct coller etc. to be supplied from TEC approved sources with allaccessaries. (Inspection by RITES)
Supply, Transportation and installation of concrete (RCC) route indicators at interval of 50 mts as per technical specification. They shold be of stadnderd RCC with letters one side "CR" 5 and the other side" S&T CABLES" AS per DRG/BSL/CONST/TELE/RCC/CABLE ROUTE MARKER -01 & colour of paint will be RED for 6 Quad & Signalling ,Orange for OFC,Green for joint .Engraved letters should have a height of at least 4 inches (100 mm) or 2.8 inches ,Markers are engraved with identifying text such as "IR SIG," "IR/6 QUAD CABLE," or "OFC (Inspection By Consignee)
Transportation of telecom material/equipments including loading and unloading in 6 10MT vehicle, anywhere to anywhere,and stacking at destination as per instructions of SSE in-charge as per inventory. For carrying heavy materials like cable drums, DG set, Electrical lifting barrier pedstal, IPS, Batteries, Point machine etc.UNIT : NOS = PER TON PERKILOMETER
Maintanance free earth. As per RDSO /SPN/197/2008 or latest consisting of : (1) Copper bond steel electrode 3 mtr long 17 mm dia with copper bonding thickness of min. 250 micron & UL listed & marked - 01 No. (2) Earth enhancement compound RDSO Approved in sealed bag of 10 Kgs - 03 No. (3) Copper strip 150X25X6 mm - 02 (4) Copper strip 300X25X6 mm - 01 (5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15 Mtr. Approx. (Inspection by RDSO)
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK/815 (Inspection by RDSO)
Supply of 48 fibre straight joint closure (SJC) complete with all accessories as per 9 RDSO specification No. RDSO/SPN/TC/68/2014, Rev.1.0 and as per or TEC Spec.G/OJC/02/02 Sept.2003 or latest of Raychem make model FOSC 400 B4 48F or TVS ICS make model 1500-L:1 83 - XX or Birla VXL make model VT-200 or 3M make model 2179 CD or similar make. (Inspection by Consignee)
Supply AND INSTALLATION of Fibre management system Birla 3 M/TVS R&M make 10 suitable for 48 fibres with 48 pig tails, FCPC connectors splicing tray etc. This includes provision of termination of two no of optic fibre cable along with rack with mounting arrangement. (Inspection by Consignee)
"Supply, installation, testing and commissioning of TANSY hybrid multiservice device 1.5U Height & 19"" rack mountable supporting STM 1/4 interface or 2x10Gps ports two SFP ports included for 1Gbps optical fiber support: Four Gigabit Ethernet ports(Railnet); Eight El circuits for data: dual power supply, DC supported; Three empty slots to support FXO/FXS & E&M for auto phone 11 and control phone (conference); Make : TANSY/NOKIA/LANTANA/CISCO/ WAVES or similar 1)STM 1/4 SFP module 10 kms 2 numbers or 1Gps module 2) 10 port FXS auto interface module. (01 no.). suitable for TANSY (3) 4 port E&M voice module (01 no.) suporting controll phone (conference facility) (4) 10 Port FXO module (01 no.) suitable for TANSY all included or FXS -FXO combine module (6+4) instead of invididual modules of FXO & FXS 4) four port Ethernet module with 2 ports supporting POE for VOIP/Camera Inspection: RITES"
"Supply & Installation of Lightening & Surge protection device, Single phase + neutral (housed in a suitable impact resistance box) for providing B-class protection as per RDSO Spec. No.RDSO/SPN/165/2012 (Ver 3.0). The main components of device should be OBO, Phinix or Shirtec 12 Make with indication box and Elmex type terminals with nut and bolts duly wired with 16 sq.mm Copper wire between each phase and neutral and 25 sqmm between neutral and earth comprising of (a) One module to be connected between phase and neutral and (b) One module to be connected between neutral and earth as per technical specifications mentioned in Annexure. (Inspection by Consignee)"
"Supply & Installation of Lightening & Surge protection device, Single phase + neutral (housed in a suitable impact resistance box) for providing C-class protection as per RDSO Spec. No.RDSO/SPN/165/2012 (Ver 3.0). The main components of device should be OBO, Pheonix or 13 Shirtec Make with indication box and Elmex type terminals with nut and bolts duly wired with 16 sq.mm Copper wire between each phase and neutral and 25 sqmm between neutral and earth comprising of (a) One module to be connected between phase and neutral and (b) One module to be connected between neutral and earth as per technical specifications mentioned in Annexure. (Inspection by Consignee)"
Supply of optical power meter, optical light source and amp visual fault locator conforming to tender document Chapter VI (Inspection by Consignee)
Supply of Digital earth clamp tester for measurement of earth resistance. Make - Motwane Model DECT-3/ FLUKE Model-1630/ MECO Model-4680 B/ KYORITSU Model-4200. Generalized Specilication for Portable Digital Earth Clamp Meter is as under:- SN. Parameters Characteristics l.Resistance measurement range--O.Ol Ohm to l2OO Ohm. 2.Current Measurement Range--0 to 2O A, 3.Display--4 digrts 9999 count LCD, 4.Resolution Range--O.OO1 Ohm to 30 Ohm,5.Accuracy-+/-( I percent+ 0.01 Ohm to +/-(25 percent +30 Ohml,6.Conductor size -- 23mm 15 approx / 35mm approx, 7.Jaw size --65mm x 32mm, 8.Instruction manual-To be provided, 9.Computer interface - RS 232,US8, 10.Environmental - Working temperature: 0 deg to 50 deg, Humidity less than 85 percent RH. 11.Memory Storage Facility-99 records 9(i) loop resistance with no inductive, external magnetic field-- < 50 A /m 9(ii) External electric field -<1 V/m,10.Power Source-6 v DC (4x1.5 V AA alkaline batteryl, 12.Single measurement / Sampling time- 0.5 second, 13.Sound and light enunciator - Beep sound, Flashing Symbol, AL Key to turn on - off and setting the sound and light alarm, 14.Overload Indicator- -"OL" on display, l5.Overload Protection - 100A [Continuous],200A[5 sec], 16.Low battery indication- Display Symbol, 1 7. Range Selection- -Auto, 18,Single Measurement time-0.5 sec(Inspection by Consignee)
Supply of Themoshrink jointing kit (Reinforced) TSF 2 type generally conforming to RDSO specification RDSO/SPN/TC/57/2015 rev 1 with modified kit contents as per CSTE's Specification No: CR/SPN/TC/57(A)/2015 dt. 06.01.2015 (Table A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 quad cables along with sub-kit (Table-B) for armour continuity. (Inspection by RDSO)
Supply of Thermo Shrink jointing kit (RSTF-4)for jointing underground quad cable (0.9mmconductor dia) Quad cable as per RDSO Spec.No. IRTC 77/2012 (Rev.3.0) Amdt.3 or latest.Firm's Offer Make-Trendbull. (Inspection byRDSO)
Supply of CAT 6 Cable with identifications marking on cable at regular interval of make: Molex or D-Link ,network, krone or similar.(Inspection by Consignee)
Supply of patch cords, 15 Mtrs. long with FC-BC, FC-PC to FC-SC or latest suitable connectors as per tech spec. Gr. No. G/OFJ-0I/O3 Jan 99 with latest Amendment to suit the existing system/FDMS & supplied OFC equipments (Inspection by Consignee)
Supply of multi strand PVC insulated flexible power coppercable, size: 3 coreX2.5 sqmmindividually PVC insulated&overall PVC sheathed 1.1 KVGrade conforming to IS :694and 8130. Make: HAVELLS/FINOLEX /POLYCAB /KEI orsimilar (Inspection by Consignee)
Supply and installation of 20 pair CT box (Inspection by Consignee)
Supply of KRONE DP 10 pairs in metal box with locking arrangement as per tender document. Conforming to Tender Document Chapter VI (Inspection by Consignee)
Supply and fixing of 25 mm dia. PVC channel, with cover and running switch board cable through them. make Precision or Presto plat or presto teak or similar (Inspection by Consignee)
Supply of PVC channel 25mmx 38mm with other fixings all accessories like clips, T bends & coupling etc. make Precision or Presto plat or presto teak or similar (Inspection by Consignee)
Supply of KRONE DP 20 pairs in metal box with locking arrangement & krone module for 20 pair (Spec no. G/CTN-10/03 june 2005) as per tender document. Conforming to Tender Document Chapter VI (Inspection by Consignee)
Supply & fixing size 50 x 50 mm of PVC Casing capping on wall with all accessories . This includes laying of telecom cables inside the installed PVC casing of ISI make or approved. (Inspection by Consignee)
Supply, fixing & cable termination of 100 pair Krone DP box suitable for external/Internal use conforming to tender document Chapter VI.(Inspection by Consignee)
Supply of PC based network health and Diagnostic system with report generating facility conforming to tender document Chapter VI. (Inspection by Consignee)
SUPPLY of All in one Printers - Laser Jet Pro, M126nw, Print copy scan, WiFi Printer, Compact Design, Reliable and Fast Printing, Network support, Warranty : 03years ( with extended warranty of 02 yrs ) . Conforming to Tender Document Chapter VI (Inspection by Consignee)
SUPPLY of MULTI FUNCTION COLOUR PRINTER FOR A3 PAPER SIZE conforming to tender document Chapter VI. (Inspection by Consignee)
SUPPLY OF ON LINE UPS WITH ISOLATION TRANSFORMER SUITABLE FOR SINGLE PHASE AC INPUT & SINGLE PHASE AC OUTPUT,FLOOR MOUNTED TYPE. RATING OF UPS 2.0 KVA,BACK UP TIME 120 MINUTES. Conforming to Tender Document Chapter VI (Inspection by Consignee)
Supply of Record table Make Godrej Model T102 or latest. (Inspection by Consignee)
Supply of Chair Make Godrej Model PCH 7001 or latest (Inspection by Consignee)
Supply of Optical media Converter.Fiber to 4 E1 ports and one Fast Ethernet port of 41 10/100 mbps.Uplink port for point to point connectivity.Working voltage 230VAC/48V, DC on same socket.Make;MROTEK/Team Engineer/CYGNUS . Conforming to Tender Document Chapter VI (Inspection by Consignee)
SUPPLY of LAN extender as per RDSO specification no.RDSO/SPN/TC/82/2020 rev2.0 similar to make CYGNUS/TEAM Engineer/NOMUS (Inspection by Consignee)
"Supply of E1 to Ethernet Converter Make MROTEK PINE IEI/4FE/AC/DC or similar with same Specification. one E1 interface & four Ethernet interface . Conforming to Tender Document Chapter VI (Inspection by Consignee) "
Supply of Digital measuring wheel for measuring cable trench/route make: Stanley or Freemens make or similar reputed make.(Inspection by Consignee)
Supply, Installation and commissioning of 2400 pair MDF & 1200 pair IDF bothwith KRONE Module and protection. Fitted with Integrated Protection Module(IPM) for all extensionlines at 45 Exchange side . MDF and IDF shall be fully wired with jumpers . The specification are : 1.Min. threshold I/P voltage -230V, 2.Max. withstand voltage for protection- 40 KV, 3.Min I/P threshold current- 0.2 Amp,4. Operating time- 1ms. TheMDF & IDF should conform to Specification No. GR/CTN01/04.MAY. 2005 orlater. Detailed technical specification as per Chapter VI. Make ADC Krone orsimilar. Material to be approved before supply. (Inspection by Rites)
Supply & installation of 42 U Rack with PDU, FAN and other accessories for zonal or divisional hq. Detailed technical specification as per chapter VI.make HCL,APW,Rittal,President or similar. (Inspection by Consignee)
Supply of Servo voltage stabilizer of 1500VA input voltage 180 to 270V AC output voltage 220/230V AC. Make - v Guard VND 500/Servokon 500 or similar. (Inspection by Consignee)
Supply of extension board (Spike Guard) 5 Amp,3 pin, 6 sockets having line indications, filter ckt. Anchor,MX,Neutronics, Olvetti make or similar.(Inspection by Consignee)
Supply of CT box with krone terminal 50 pair. Make Phonics or Krone or Similar. (Inspection by Consignee)
Supply of line cord with connectors at both ends. (Inspection by Consignee)
Supply of Telephone Handset Phone Receiver Cable Cord Wire with connector at both ends.HMT cord or similar. (Inspection by Consignee)
Supply of Telephone Rosset for single line auto telephone with RJ-11 Types socket and line termination screw (Inspection by Consignee)
"Two Line cordless telephone with following minimum features : Handset with Caller ID, Frequency: 1.9 GHz, Frequency Range: 1.92 GHz - 1.93 GHz, Number of Channels: 60 Channels, DECT6.0, Number of Phone Lines: 2, Multiple Handsets Capability: Up to 6 Handsets, LCD Language: English, Noise Reduction, Conference Call with Outside Line, 3 Way, Intercom (i.e. Handset to Base 53 Unit), LCD for Cordless Unit with caller ID feature: 1.8 inch Full dot or higher, LCD for base Unit with Caller ID Feature: 3.4 inch 3 line display, Hold, Music on Hold, Mute, Flash, Headset Jack, Wall Mountable (Charger) Handset (Power Outage Operation) for base Unit, Speakerphone (Volume Steps) for base unit and cordless both, Ni-MH Rechargeable Battery Talk Time: Up to 15 hours, Standby Time: Up to 7 days, Charge Time: About 7 hours, Standby Power Consumption: 1.2 W, Answering System for both lines Phone should be link to cellphone, Minimum 2 no. should be supported, Ring as CELL Mode, Bluetooth". ( Inspection by Consignee).
Supply of 24 ports LAN switch layer 2 type.
Supply of RJ-45 Connector.
Supply of UTP I/O box singleport surface mounting havingone RJ-45 port [Inspection by CONSIGNEE]
Fixing of UTP I/O box as persite location and instruction of site engineer of Railways. [Inspection by CONSIGNEE]
TP-Link 3000Gigabits_per_Second 5 GHzWiFi 6 AX3000 Smart WiFi Router conforming to clause mentioned in Chapter No. III(Inspection by CONSIGNEE)
ZEBRONICS Bluetooth Speakers LED indicator and LED Display and Headphone Jack 59 and MP3 and FM and Memory Slot Main Speaker Warranty 1 year Brand: ZEBRONICS (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687766103360 dt.06/03/2025) (Inspection by Consignee)
"Supply of E1 extender at OFC end with following specifications: operations on 2-wire copper circuits using G.SHDSL, Driving range:6.5 km at 2048 kbps on 24 AWG(0.5mm dia) unloaded 60 copper pair under error-free conditions. Power supply input-options for 230 VAC, 48VDC , 24 VDC or various combinations .Make: CYGNUS, Teamlink or similar. Firm's offer:-Make/Brand-TEANLINK 3002 G.SHDSL E1 Modem (Warranty Period : Upto 12 months from the date of delivery.) (Inspection by Consignee)"
SUPPLY OF LIU OFC TERMINATION UNIT (Rackmountable 24 port) along withsupply of all accessories suitablefor Mono/Multi (as per siterequirement) mode fiber like LC adaptor plates, LC connectors,LC pig tails and blank plates etc.(Inspection by Consignee)
Supply of single mode 6 fibrearmoured optical fibre as perITU-TG 652D cable . Make- Dlink/Molex/Amp/Finolex/sterliteor similar (Inspection byConsignee)
supply of 06 core optical fibercable Un-Armoured SingleMode.D-link or better. Accepted Make/Brand - "D-Link/Finolex/Sterlite or similar (Inspection by Consignee)
HDPE duct 40/33mm As perRDSO/SPN/TC/45/2013 Rev. 2.0with Amendment. For each 64 KMof HDPE duct following items areto be supplied a)- End plug-2No. b)- Cable sealing plug- 2No. c)- Plastic couplers slipfit/push fit type-2No. d)- Endplug to be provided along withdrum-2 Nos (Inspection by Consignee)"
"Supply of PVC switch board 10pair 0.5mm dia. Annealed copper telephone 65 cable,conductor solid annealed barecopper 0.5mm diameter as perTec spec. No. GR-WIR 06/03march 02 or latest. Make:NETWORK CABLES, Finolex,Delton OR SIMILAR (Inspection by Consignee)"
Supply Installation & commissioning of 12 Port LIU Rack mountable. LIU should be provided for terminating theoptic fiber cables. It shall provide minimum bending radius and the splice trays shall function as a splice cover for pigtail splicing. This shall include supply of pigtails. Cable glands shall be provided for secured anchoring of incoming cables.Rubber grommets shall be provided at the cable entry point for tight sealing. The splice tray shall be made of ABS materials.LIU should be of reputed make.(Inspection by Consignee)
Splicing/Dropping/Termination of each fiber/pigtail in LIU/IO BOX/Terminal Joints 67 through fusion splicing for termination of OFC cables. The fibers terminated shall be tested and test report (hard & soft copy)shall be submitted to railways site incharge for records. each fiber shall be properly marked with necessary ferrules/tags.
Supply of RJ-45 patch cord Cat-6 STP, 2 mtrs long. Make D-link,Digisol,Spectra or similar.(Inspection by Consignee)
Supply & Installation, commsioning of CAT-6 UTP/STP24 port RJ-45 Jack Patch Panel suitable for STP/UTP. MakeAVAYA / LUCENT / AT&T or COMSCOPE / D-LINK or similar.Specifications as per Chapter 3 of tender document. (Inspection by Consignee)
Supply of Layer-2 managed POE Switch (8 ports 10/100/1000BASE-T ports, 2 SFP 1G uplink ports) with SFP module .Specifications as per Chapter 3 of tender document. Make -Cisco, HP, Juniper , Alcatel, Dlink, TP link or similar.(Inspection by Consignee)
Supply of 8 port SFP layer 2 switch with all SFP ports.This includes supply of SFP module.Model CBS350-8S-E-2G-xx orsimilar Make/Model of Cisco, HP,Juniper , Alcatel, D link, TP linkor similar. (Inspection by Consignee)
Supply, installation & commissioning of 19'' 42U covered racks with all accessories like electrical fitting, Fan, AC power distribution panel,Fan tray, Cable manager,Spike buster etc of HCL,APW,Rittal,President or similar make having size of approximately 2.2mtr (42Uheight) x 600mm widthx600mm depth and duly approved by the enginner incharge of the work. The rack shall be 72 complete with all fittings for housing SDH equipment, primary muxes,DDF,MDF using krone module and other equipment like runway ladders etc,completely wired & equipped with integrated protection modules for all channels as per technical specifications & other stipulation of tender document.The contractor shall provide Ulink Patch panel ,CAT 6 patchchords and other accessories required for installation & install them within the installation cost.It should be possible to lock all the equipment with only order wire telephone reaining outside the rack. (Inspection by Consignee)
Supply & installation of 19 inch 9 U rack having 600mm depth,front toughened glass door with secure lock, 02 Nos. of fan for heat dissipation with 01 No. rack tray & power distribution unit.Make HCL, APW, Rittal, President or similar. (Inspection by Consignee)
Supply of GI pipe with thread collar of 40mm nominal bore,specification no. IS-1239 medium grade of TATA/JINDAL/ZENITH BIRLA make or similar (Inspection by Consignee)
"Cable Tray Size- 150mm widthx 50mm depth x 1.6mm thick perforated GI cable tray including Horizontal and vertical reducers tees, Cross members and other accessories as required and duly Suspended from the celling with GI suspended etc. (Inspection by Consignee)"
Supply of PVC Casing Caping Ivory/White Colour, Size:25mm width and 1mm thickness . Shall be Fire Proof, Shock Proof,Termite Proof. (Inspection by Consignee)
Procurement of Wall Speaker with Volume control for Waiting Room, Enquiry office similar to model.no. WS-664T of AHUJA make or similar (Inspection by Consignee)
Supply of microphone for general PA with connector .Make AUD-99MS or similar & 06 78 meter screened cable with all necessary accessories as per RDSO/SPN/TC/63/2006 ver 1 or later. make AHUJA,Philips,Boschor similar. It Shall be compatible with amplifier and speaker taken in the schedule. (Inspection by Consignee)
Caller Id phone having following minimum specs Mute, two way speaker, Caller ID should be at least 7 segment 2 line display, pulse and tone setting, programmable flash, pulse /tone setting, support both DTMF and FSK, 30 number call log, 5 numbers of redial memory, 1.5mtr Receiver cord cable, should work without battery and external supply and must have at least one year warranty. Make- Beetel, Panasonic or similar.(Inspection by Consignee)
Industrial grade 43 inch Television Make LG, Sony, Samsung or similar.Specifications as per RDSO/SPN/TC/108/2019 version1 with latest amendment. (Inspection by Consignee)
Supply, installation and commissioning of L2 Manageable 24P POE, 24P GE 81 10/100/1000 Base X Ethernet Port with POE+ Support and 4X 1GE SFP port for Uplink with 4 Nos. of 1GE BX SM SFP Modules Loaded with all accessories Per RDSO/SPN/TC/65/2021 Rev 6.0 or latest. TO BE INSPECTED BY CONSIGNEE)
"Supply of 48 Port ADSL Switch (IPDSLAM) conforming to Clause No.3.7 of Chapter III and Execution portion conforming to Clause No.4.4 of Chapter IV of tender document. [Inspection of Supply portion by RITES, Inspection of execution portion by Consignee]"
Supply of DATA EQUIPMENT RACK 42U conforming to Clause No.3.12 of Chapter III and Execution portion conforming to Clause No.4.8 of Chapter IV of tender document. [Inspection by Consignee]
Supply of wall mountable 9U Rack similar conforming to Clause No.3.13 of Chapter III and Execution portion conforming to Clause No.4.9 of Chapter IV of tender document. [Inspection by Consignee]
"Supply of Arial OFC 6 Fibre core single mode Optical Fibre CableSupply Portion conforming to Clause No.3.14 of Chapter III and Execution portion conforming to Clause No.4.10 of Chapter IV of tender document. [Inspection by Consignee]."
"Horizontal boring of cable duct of minimum 2.0 Mtr. depth alongwith laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from the bottom of the rail/road crossing with minimum depth reckoned from ground level. The work shall be done as per extant 86 practice & instructions of site Engineer. Prepration of site for Horizondal boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railways. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable."
Supply, Installation, testlng & Commissioning of servers to work as IP-PBX.The server 87 shoul d be Installed with Ubuntu Server LTD 22.04.As per RB DoC No.2DZ2/Tele/9{3)/4 dated 13.09.2O22 (Note: Server should be COTS and not any proprietary server) (b) from 48 upto 5O0 subscriber. (Inspection by Consignee)
Supply 48 ports FXS media gateway. As per RB DoC No. 2022/Tele/9(3)/4 dated 13.09.2022. (Inspection by Consignee)
Supply of 04 ports EI/PRI gateway. As per RB DoC No. 2022/Tele/9(3)/4 dated 13.09.2022. (Inspection by Consignee)
Supply of SIP based basic IP phone (Non-executive phone) As per RB DoC No. 2022/Tele/9(3)/4 dated 13.09.2022. (Inspection by Consignee)
Supply of SIP based medium IP phone with minmum 8 DSS (Excutive VOIP Phone). As per RB DoC No. 2022/Tele/9(3)/4 dated 13.09.2022. (Inspection by Consignee)
Supply of 120mm HDPE pipe for laying in Horizontal Boring (Inspection by Consignee)
Supply of 6Amp MCB as per specification given in Annexure (inspection by Consignee )
Supply and installation of MCB Junction Box 8-way for -48V DC Distribution and as per Specn given in Annexure-XVII. TO BE INSPECTED BY CONSIGNEE)
16 Amps MCB double pole, suitable for operation in 230 volt, 5OHz, conforming to IS:60898.I. Make: Leg rand / HPL/ L&T / HavelIs / Schneider/ Indo Asian / Siemens or similar (Inspection By consignee) Above/
H-PART-II- Supply installation testing and Commissioning of Telecom
Excavation of cable trench as per cable route plan,1.2 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer 1 of 50 mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805 conforming to tender document. Conforming to Tender Document Chapter VI
Cutting of all types of Roads/ platforms ( Except concrete type ) for trenching and 2 excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.Drg No. SK-807
Whereever depth of 0.5 m cable trench is not feasible,cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.
Chase cutting/digging in rocky area 500mm deep in hard rocky area as per technical Specification in Chapter III.
Excavation of cable trench 1 Mtr. deep and 300mm wide across the track, for track crossing and refilling . The work shall be done as per extant practice on C. Rly & instruction of Rly engineer at site (TRACK CROSSING).
Preparation of cable duct 150 mm wide x 300 mm deep for laying of cable in Rocky 6 area and refilling the duct (after cable laying)with concrete mixture of proportion 1:3:6 & grouting the ends at either side of the rocky portion using concrete mixture with contractor's own cement & other material as per the standard practice on C. Rly. and the instruction of engineer - in - charge. (DUCT).
Provision of Pre Fabricated Joint pits ( RCC/PVC Pre Fabricated type ) as per DRG No.SK/CSTE/C/97/11 Conforming to Tender Document Chapter VI
Laying of Signalling/Power/Telecom cables of various cores/sizes in trenches
Blowing/Drawing of OFC cable in HDPE/DWC duct and protective work, as per direction of site engineer
Installation of GI Pipe 100 mm bore size,medium grade along with sockets 10 andmaterial required for fixing on Girders,Bridges i.e. suitable MS Bars and clamps atthe interval of 2 mtrs including bend pipes atthe ends and brick masonary work at bothends with contractors own material. Thedesign of the clamp shall have prior approvalof Rly Engineer. Suitable anti thefft holes tobe provided in the pipe before laying as perinstruction of site In-Enggineer.
Laying of DWC/RCC pipes alongwith collars / RCC half round pipes in trenches at places of track and road corssing, plafrom cuttings etc
Laying of HDPE Duct in trench and its protective work as per direction of site engineer Conforming to Tender Document Chapter VI
Installtion of unit earth as per RDSO/SPN/197/Ver I or latest, to construct earthing of 13 </= 1 Ohm consisting of a, digging the earth to required depth, insertion of electrode, filling of earth enhancing compound & construction of chamber, measurement of earth value and all other work of earthing as per code practice. All the consumables for mounting the copper tape inside the Telecom room ,Exothermic weld materials and tools & fixtures for the welding Copper tapes and Electrodes etc shall be arranged by the contractor.
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No. CR/S&T/SK-815 for sigg. Equipment such as lever frames, 14 apparatus case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.
Making of thermoshrink straight through / derivation/transformer / PIJF cable Joint for underground jelly filled cable 6 quad / 4 quad /20 pair 10 pair etc. PIJF cable as per the instruction of Rly engineer at site.
Splicing ( Jointing 2X24 F OFC ) and testing of 24/48 fiber OF cable and making the 16 splice joint as per direction of site engineer with contractors own splicing machine & tool. Splice loss of each fibre should be less than or equal to 0.05 db splice reflctance should be better than 60 db Conforming to Tender Document Chapter VI
Fixing of Krone DPs & termination of PIJF cable in Krone DP duly mounted on good quality Teakwood/Hylum board and GI / good quality PVC pipe at the entry of Krone DP as decided by site incharge.
Installation, wiring, testing & commissioning of lightening current arrestor (Class B & C) as mentioned above or as per instruction of Railway Engineer .
Provision of Man power inconnection of transporting of material in emergency during execution of the work.
Loading & un loading & transportation of material from the Stores of SSE (Sig) depot or any other nominated place & vice-versa. 1 Numbers=1 per ton/per KM
Providing road breaker/ concrete breaker with compressor and jack hammer for 21 railway work such as cutting and dismantiling of road concrete/Bricks pucca structure (RCC/Steel section) including contractor's fuel, driver and all other charges completed as directed by site Engineer.
"Installation,Testing & Commissioning of 48 port FXS Gateway. The work is to executed as per the instruction of Railway Engineer. (Inspection by Consignee) """
"Installation,Testing & Commissioning of 02/04 Port PRI/ E1 Gateway. The work is to executed as per the instruction of Railway Engineer. (Inspection by Consignee) "
Installation,Testing & Commissioning of 8/16 port FXO Gateway. The work is to executed as per the instruction of Railway Engineer. (Inspection by Consignee) "
Installation,testing & commissioning of L-2 POE switch 24 port & 8 port LAN manageable switch10/100/1000 base with 4 SFP port loaded (Inspection by Consignee)
Laying of OFC/STP/Power/data/Telecom/PA cables in trenches & casing along with fixing of casing capping.
Installation of perforated type cable tray with necessary MS angle suspension supports/treated rod support anchor fasteners/threaded nuts & bolts etc. Complete Maximum height of suspension should Not exceed 500 mm or as advised by Railway's site engineer.
Installation and commissioning of 12 Port LIU with all accessories.conforming to Clause No.4.6 of Chapter IV of tender document. [Inspection by Consignee].
"Splicing/Dropping/Termination of each fiber/pigtail in LIU/IO BOX/TERMINAL JOINTS through fusion splicing for termination of OFC cables conforming to Clause No.4.7 of Chapter IV of tender document. [Inspection by Consignee]" Above/
H-PART-III- Supply installation testing and Commissioning of Telecom
Supply of 50 pair X 0.5 mm Dia Polythene Insulated Polythene Sheathed Jelly filled 1 Underground Telephone cable with poly aluminum moisture barrier annealed copper conductor double steel tape armored with polythene jacketed as per RDSO Spec. No. IRS: TC/41/97 with Amdt.3. Packing length should be 500 Mtrs per drum. (Inspection by RDSO)
Supply of 48 fiber armoured Optical fiber cable as per RDSO specification no.- RDSO/ SPN/TC /110/2020(Rev.0) or latest. ( Warranty Period : Upto 30 months from the date of supply) (Inspection by RDSO)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TD02202627_compressed.pdf TD 02 2026 27
ATTACHMENT
TD02202627_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid