Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC KOTWALI STREET MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MP | 474006 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹24.9 L+₹14,549.25 (0.59%)Rejected-Finance OFFICE 4 9 SWARG ASHRAM NANAK RAM COLONY PARMANAND CHOWK DELHI 110009 | DELHI | DELHI | DELHI | 110009 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹25.6 L+₹83,945.20 (3.39%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹25.8 L+₹1.1 L (4.29%)Rejected-Finance 28A RAGHAVPURAM OPPOSITE PRAGATI VIDHYA PEETH SCHOOL SLP COLLEGE ROAD CP COLONY MORAR GWALIOR 474006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹27.1 L+₹2.3 L (9.49%)Rejected-Finance NARMADA COLONY BARADARI CHOURAHA MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
10 Feb 2024, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Gwalior Morar Cantt
8927/GWL/E8 SPECIAL REPAIR WK TO BLDG NO P-219 AND P-222 AND OTM BLDG NO T-12 IN THE AREA OF AGE B/R-I AT MORAR CANTT UNDER GE GWALIOR
2024_MES_637304_1
8927/GWL/E8
Open Tender
Civil Works
Works
180 days
Garrison Engineer Gwalior
Please refer tender documents
9 documents required · 9 mandatory
₹500
Garrison Engineer Gwalior
₹72,000
Yes
9 Mar 2024
13 Jan 2024
14 Feb 2024
13 Jan 2024
10 Feb 2024
27 Jan 2024
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75 mm thick Cement concrete 1:2:4 type B1, (using 20 mm graded stone aggregate) as in sub base for floor, finished even and rough complete all as specified and directed.
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
S&F for steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 290,Gde E-165 complete all as specified and as directed .
Dismantling of asbestos cement (corrugated, semi-corrugated) sheets in roof covering including ridges etc complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having aluminum zinc coating 150 gms/ sqm having tensile strength of 550 Mpa as in Roof covering /cladding to wall, ridge fixed with self tapping screws complete all as specified and directed.
S&F for flat iron of size 50x5mm thick wind ties fixed to CGI/Galvalume sheets on roof including or necessary drilling, bolting or riveting etc confirming to Fe- 290 grade E-165 complete all as specified and directed.
S&F in repairs Steel rolling shutters, thickness of lathing 1.25mm, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete gear operated type with bevel gear box and crank handle complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L 15mm thick rendering in cement mortar 1: 4 on brick or stone/concrete any surfaces mixed with WPC @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured & paid seperately.
M&L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth, complete all as specified and directed
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
Preparation of new plaster surfaces of wall applying three coats of white wash complete all as specified and directed.
M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrapping or any other means, on walls complete all as specified and as directed.
M&L for three coats of white wash on wall surface complete all as specified and as directed.
M&L for applying two coats of cement base paint over a coat of primer including preparation of newly plastered surface of walls complete all as specified and as directed.
M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrapping or any other means, includind removing vegetable/plants root from walls/chajja's complete all as specified and as directed.
M&L for two coats of cement base paint over a coat of primer on wall surface complete all as specified and as directed.
M & L for applying two coats of synthetic enamel paint over one coat of red oxide primer on new steel surfaces (previously untreated) including preparation of surfaces complete all as specified and directed.
M & L for applying one coat of synthetic enamel paint on old painted steel surfaces including preparation of surfaces complete all as specified and directed.
M&L for 25 mm thick cement concrete 1:2:4 type B0, (using 12.5mm graded stone aggregate) as in leveling course complete all as specified and directed.
M&L for Screed bed or bedding layer of 15mm thick CM 1:6 for laying floor finishes complete all as specified and directed.
M&L for non - skid ceramic tile coloured 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match, complete all as specified and directed.
M&L for non - skid ceramic tile coloured 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on vertical surface such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 10 mm thick rendering on fair faces brick work or concrete surface in cement plaster 1:4 complete all as specified and directed.
M&L for 10 mm thick rendering on fair faces of brick work or concrete surfaces in cement plaster 1:6, finished even and smooth (without using extra cement) complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for Brickwork with subclass 'B' bricks old size brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 and mixed with WPC , finished even and smooth (without using extra cement) complete all as specified and directed. (Note:- WPC shall be measured & paid seperately).
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 20mm graded stone aggrtegate) as in plinth protection/path and the like including finsihing surface even & fair complete all as specified and directed.
Taking down chowkhat frame with shutter (without taking out shutter from the frame) size n.exc 1.50 Sqm each complete all as specified and directed.
Taking down chowkhat frame with shutter (without taking out shutter from the frame) exc 1.50 Sqm but n exc 4 sqm each complete all as specified and directed.
S&F pressed steel door frame 125mmx60mm with one or more rebates including necessary fixing lungs and hinges, lock strike plate,etc complete all as specified and directed
S&F for 35 mm thick glazed and skeleton shutters of 2nd class Hard Wood, open rebated and prepare to reveive glass, guage etc (without sash bars ) edges of framing plain chamfered or rounded, fitted with for securing glass etc, size of members of shutters as specified in SSR Pt-I, section 8, clause 8.24(a) complete all as specified and directed.
S&F for 30mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
M & L for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S & F anodised aluminium door / window shutters, aluminium section weighing not less than 0.55 kg/m including necessary jointing cleats, Glazing clips , rubber neoprene packing, handles two numbers in each door, 100mm long 03 Nos brass hinges, 200mm long aluminium tower bolts, 01 Nos door stopper anodised aluminium snap beading screws etc including fixing floor machene and godrej lock with minimum 6 keys for each lock in each door complete all as specified and directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing conforming to Fe 290 (Gde E-165) complete all as specified and as directed.
S&F for 4 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pan complete all as specified and directed.
S&F for galvanised mild steel wire cloth 0.46 nominal dia of wires and average width of aprature 1.18mm and fixed with tinned tacks galvanised wire staples fixed including a coat of french blue paints complete all as specified and directed.
S&F for 100 mm butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
S&F alumunium handle cast type anodised 150mm long complete all as specified and directed.
S&F 200mm long alumunium anodised barrel tower bolts of extructed section complete all as specified and directed.
S&F aluminum alloy anodized sliding door bolt 300mm long with hasp and staple (bolt type) and fixing clip of sheet and cast in extruded section and fixing bolts and sliding bolt of extruded section complete all as specified and directed.
M&L for preparation of new wood or wood based surface of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surface of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparing of old surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efforecent salt and trading oil and greasy spots plastered or un plastered surfaces of wall including cornices, pilasters etc. and applying one coat of cement base paint white or tinted complete all as specified and directed.
M&L for prepration of new plastered surfaces of walls and applying two coats of weather proof water based emulsion paint ( Acrylic paint exterior grade) over a coat of Acrylic primer and including filling depression etc. complete all as specified and directed.
M&L, applying two coats of distemper oil emulsion white or tinted over and including a layer of 3mm thick wall care putty on wall complete all as specified and directed.
M&L for Preparing of old decorated plastered or unplastered surfaces of wall including washing, rubbing down and stopping of distempered surface M&L for applying one coat of distemper oil emulsion paint white or tinted complete all as specified and directed.
Removing existing water proofing treatment (Brick tile terracing), roughning of concrete surfaces, cleaning of concrete surfaces with water and removing debries/rubbish off materials out side of Ministry of defence (MOD) land complete all as specified and directed.
Cutting out cracks to 'V' section in existing roofs or tarracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed.
M&L 15mm thick screed bed or cement mortar 1: 4 on concrete surfaces mixed with WPC, surface finished even and smooth W/O using extra cement complete all as specified and as directed. (WPC shall be measured & paid seperately).
M&L for bitumenous based primer conforming to IS-3384-1965 @ 0.40 Kg / Sqm including preparation of roof surface complete all as specified and as directed.
M&L for APP based polymeric membrane minimum weighing 3.5kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application method complete all as specified and directed.
M&L for after laying the membrane apply a coat of bituminouse aluminium paint @ 200 gm/Sqm (minimum) in two coats complete all as specified and as directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate), as in sub base for floor finished even and rough complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
M&L for 60 mm thickness rubber moulded machine pressed precast concrete interlocking paver block M-35 any shape and size, confirming to IS 15658-2006 in grey cement glossy finish rubber mould casted laid dry over sand cushioning complete all as specified and directed.
S&F for anodised aluminium snap grid frame work for false ceiling consists of powder coated aluminium angle of size 22x22x1.3 mm and Tee 35x25x1.3 mm of size and grid 600x600 mm complete all as specified and directed.
M&L for Non asbestos fibre cement building boards 6 mm thick fixed or laid/ inserted to Aluminium anodised frame and hanges framework fixed with Hangers 3-4 mm dia. G.I. (upto reqd length) adjusting level fixed to roof slabs by means of ceilling cleats complete all as specifed and directed
Cutting holes in brick walls built in cement mortar for inserting hold fast etc and making good the disturbed portion in CM 1:3 or cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate), depth as required, depth exc half brick thick wall but not exc one brick thick wall complete all as specified and as directed.
Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed.
Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed.
Taking down unserviceable Sheet metal box & MCB DB SPN with MCB's of any make/capacity, complete all as specified and directed.
Taking down unserviceable TPN DB with MCB's of any make/capacity, complete all as specified and directed.
M&L for concealed point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No) not less than 20 mm dia confirming to IS 14930 (Part-I) 2001, with all fitting and fixing accessories and 1.5 Sqmm FRLSH PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes factory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches. sockets etc complete for the following complete all as specified and directed.:-
One light point controlled by one switch.
One Ceiling fan point controlled by one switch.
One Exhaust fan point controlled by one switch.
One 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch.
One 3 pin/5 pin switch socket outlet, 5 Amps on independent board.
Description all as per item No 66 here in before but point wiring with 2.5 sqmm FRLSH H confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire.
S&F switch piano, flush button single pole one way 5 Amp complete all as specified and directed.
S&F socket out let, multipurpose, 2 in 1 5 pin, 5 Amp complete all as specified and directed.
S&F switch piano, flush button single pole one way 15 Amp complete all as specified and directed.
S&F socket out let multipurpose flush type, 2 in 1 6 Pin 5/15 amps complete all as specified and directed.
S&F ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed.
S&F Lamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings non ISI Marked complete all as specified and directed.
S&F electronic step rotary type fan regulator PVC/Polycarbonate, of two module capacity 80 to 100 Watt, 240 volts, AC 50Hz complete all as specified and directed.
S&F Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviormental friendly energy efficient ready to use >130 Lm/watt , 20 watt, 6500K fitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
S & F security light fittings better optics for uniform distribution IP 65 protection LED of 30 watt, Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mtr fixed to wall with 02 Nos FI clamps made of flat iron of size 40 x 5 mm alongwith, 15 cm long, 8 mm dia bolts and nuts with 2 Nos of washers grouted in wall complete including reqd length of 1.5 Sqmm PVC multistranded BIS marked, 03 core copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply & fix exhaust fans AC single phase 230/240V of size 300mm sweep with louver complete all as specified and directed
Supply & fix BLDC energy efficient ceiling fans 1200 mm sweep with minimum air delivery 210 cum/min down rod all accessories required including regd length of 3 core 1.0 sqmm PVC multistranded copper conductor, PVC connector for proper hanging of fan and testing complete all as specified and directed.
Supply & fix Air Circulator wall mounted fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting complete all as specified and directed.
M&L sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia confirming to IS 14930 (Part-I) 2001, with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
S&F in renewal sheet metal enclosure double door distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 63 Amp,4 pole & Including MCCB 63 amps 4 pole 16 KA complete. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F MCB DB, sheet metal enclosures double door SPN 12 way with rated bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F for MCB SPN 63 Amps, 240 volts 'C' series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed.
S&F for MCB SP 240 volts, 63 Amps, 'C' series 10 KA including connection with suitable size copper lugs. complete all as specified and directed.
S&F for MCB SP 240 volts, 6 to 32 Amps, 'C' series 10 KA including connection with suitable size copper lugs. complete all as specified and directed.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty) with aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 4 Core complete all as specified and directed.
Excavation in trenches n exc. 1.5 m wide and n' exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling of excavated soil, including spreading leveling, watering and well ramming in layers, not exceeding 25cm complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and directed.
Supplying and laying un reinforced precast concrete cable cover Class LV, Type I, flat of size 250mm x 150mm x 40mm complete all as specified and directed.
S&F tube 'Light' grade galvanised Pipe of 50 mm dia with all fitting for cable protection, laid in trenches, fixed to wall and floor by MS shaddle & fixed with pole, 02 position by MS clamp made of 40x5 mm MS flat, complete all as specified and directed.
M&L, sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 2.5 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 2.5 Sqmm FRLSH confirming to IS 14390 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) for 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe of 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm size MS Flat in 'D' shape 500 mm legth grouted in wall complete 01 x 6 mm multistrand PVC insulated copper conductor ( Green Colour) to be provided from test point to DB through 20 mm dia concealed non metallic conduit complete all as specified and directed.
Taking down ceiling fan of any sweep,removing blades, cleaning the fan completely of dust and dirt and Re-hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including renewal of old unserviceable fan hook rubber pad, nut bolts and washers etc, complete all as specified and as directed.
Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed.
Taking down unserviceable Sheet metal box & MCB DB SPN with MCB's of any make/capacity, complete all as specified and directed.
S&F LED Lamp 09/10 watt 130 lm/watt complete with 5 star rating complete all as specified and directed.
S&F Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt,130 lumen/watt 6500K fitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
S & F security light fittings better optics for uniform distribution IP 65 protection LED of 30 watt, Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mtr fixed to wall with 02 Nos FI clamps made of size 40 x 5 mm alongwith 15 cm long, 8 mm dia bolts and nuts with washers grouted in wall complete including reqd length of 1.5 Sqmm PVC multistranded BIS marked, 03 core copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and directed.
S&F sheet metal enclosure double door for distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 100 Amp,4 pole & Including MCCB 100 amps 4 pole 16 KA complete. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F MCB DB, sheet metal enclosures double door SPN 8 way wiith suitable size rated bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area of size 25 Sqmm 3.5 Core. complete all as specified and directed.
M&L for Bricks, old size sub class `B' laid in trenches with width wise along the alignment of the cable as protection complete all as specified and directed.
S&F tube 'Light' grade galvanised with all fitting laid in trenches, fixed to wall and floor of 40 mm dia for cable protection complete all as specified and directed.
M/s Himgiri construction
M/s Subhash Construction Co.
BHAGIRATH CONSTRUCTION COMPANY
M/s Tirupati construction
M/S SANJAY AGARWAL
mahamaya constructions
SHARMA BUILDING AND GENERAL ORDER SUPPLIERS
M/s NILAY ENGINEERS
Babatia super works
M/s KGN Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .