Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC 39 W 1 ASHOK VIHAR SAKET NAGAR KANPUR 208014 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208014 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹27.0 L+₹1.2 L (4.62%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹28.0 L+₹2.2 L (8.40%)Rejected-Finance PLOT NO 74 150 FT ROAD P O NEW P A C GANGA NAGAR MARG SHYAM NAGAR KANPUR 208015 UP | KANPUR | KANPUR | UP | 208015 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹28.7 L+₹2.9 L (11.2%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹28.9 L+₹3.1 L (12.0%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹31.5 L
EMD Value
₹63,000
Closing Date
1 Sept 2022, 6:00 pmClosed
Maj Srinath PL
GE I Kanpur Cariappa Road Cantt Kanpur 208004
SPL REPAIR TO BLDG NO P-14 (UNIT COOK HOUSE) AND SPL REPAIR/ REPLACEMENT OF BER CEILING FANS AT KANPUR CANTT AREA UNDER GE(I) KANPUR
2022_MES_543409_1
GE(I)/KAN/T-47 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (I) KANPUR
₹63,000
Yes
7 Oct 2022
4 Aug 2022
8 Sept 2022
4 Aug 2022
1 Sept 2022
18 Aug 2022
Amount
Taking down chowkats without taking off shutter from chowkats area n.exc 1.5 Sqm each complete all as specified.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) area exc 1.5 Sqm and not exc 4 Sqm each complete all as specified.
Taking down shutters of any description exceeding 1 Sqm but n exc 2 Sqm each complete all as specified.
Taking down shutters of any description exceeding 1 Sqm but n exc 2 Sqm each and re-fixing in the same opening complete all as specified.
M&L 2nd class HW as in plain , solid, straight chowkhats and frames , wrought , framed , rebated on the solid, rounded or chamfered, put together with glue pinned joints complete all as specified
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing, conforming to Fe 410 W (Gde-E-250) quality A complete all as specified and as directed.
S & F hold fast of flat iron 25 x 3 mm and complete all as specified and directed.
S &F 30mm thick glazed and skeleton shutter of 2nd class hard (Hollock) prepared to receive gauge/glass (without sash bars ) fixed with mitred beeds and securing glass gauge etc sizes of members of shutter as specified in SSR part-1 section-8 ,clause 8.24(a) complete all as specified.
S & F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified.
S&F factory made steel tubular window with side hung shutters including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded etc complete all as specifed and as per HQ CELZ Lucknow Drg no LZ/C-TD/130 sheet 1/4 to 4/4 and as directed by Engineer in Charge. Note : 4mm plain sheet glass panes shall be deemed to be included in this item.
S&F factory made steel tubular window with side hung shutters including box type hinges with steel handle and steel peg stay complete without glazing bars dovetailed or welded etc complete all as specifed as per HQ CELZ Lucknow Drg no LZ/C-TD/130 sheet 1/4 to 4/4 and as directed by Engineer in Charge. Note: 0.45mm nominal dia of wire mesh and aperature 1.40mm shall be deemed to be included in this item.
S& F galvanised mild steel wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.40 mm fixed with tinned tacks or galvanised wire staples and complete all as specified and as directed .
S& F in repair galvanised mild steel wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.40 mm fixed with tinned tacks or galvanised wire staples and complete all as specified and as directed .
M&L for framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, cooler stands etc conforming to Fe-290 Gde-E-165 complete all as specified..
S & F 100mm size mild steel, butt hinges, medium weight, cold rolled and fixed with mild steel screws as specified.
S&F 150mm long barrel tower bolt of aluminium extruded section complete all as specified and directed.
S&F 150mm long handle of aluminium extruded section fabricated anodized type complete all as specified directed.
S&F 300mm long aluminium alloy, anodized sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section & fixing bolts and sliding bolts of extruded section complete all as specified and directed.
S&F 150mm floor door stopper of aluminum alloy body and tongue anodized with hard drawn steel spring fixed in floor complete all as specified and directed.
S&F 300mm mild steel, ordinary rat -tail rod pattern spring including roller and roller plate complete and all as specified and directed
S&F in repairs 25 mm dia MS powder coated decorative finish conduit as in curtain rod and fixed to brackets complete all as specified and directed.
S&F in replacement MS brackets suitable for 25mm dia cutain rod fixed with screw and gutties in wall as approved and directed.
S&F PVC side caps for curtain rod of 25 mm dia design/shape as approved and directed by Engr-in-Charges
Dismantling wall or ceiling boards (fibre, pulp insulation etc) any thickness & at any height including fittings/grids etc complete all as specified and directed.
S & F Armstrong Mineral Fibre Acoustical Suspended Ceiling System with DUNE (MICRO LOOK) EDGE TILES WITH ARMSTRONG XL 15 mm EXPOSED STEEL ANGLE. The tiles should have Humidity Resistance (RH) of 99%, NRC Upto 0.5, Light Reflectance >85%, Thermal Conductivity k = 0.052- 0.057 w/m K, Colour White, Fire Performance Class 0/Class1 (BS 476 Part 6&7) in module size of 600 X 600 X 16 mm with Bio Block coating on the face of the tile, suitable for Green Building application, with Recycled content of 38-41%.The steel angle should be of “Armstrong” make with 15mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32, 27 and 27mm and a load carrying capacity of 7.5 Kgs/Sqm. The T Sections have a Galvanizing of 90 grams per Sqm & passed through 500 hrs of Salt test ,Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centre to centre incl 2mm dia suspension wire MS @ 1200mm C/C complete all as specified and directed according to manufacturers instruction and Complete all as specified and as directed.
Dismantling of asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings including ridges complete as directed.
Dismantling of unframed work timber scantlings 40 sq. cm and over in section, in any position
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410 W (Gde-E-250) quality A complete all as specified and as directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment etc incl mild steel screw bolts (machine made) with hexagonal or square heads at one end & washers as reqd conforming to Fe 410W .Gde-E-250, quality-A.
S & F regular modified Polyester colour coated galvanized steel rib profile sheet (TCT) 0.50mm thick E42 (inclusive of protective coating ) overall width 1060mm and total mass coating of 120 gms/sqm on both sides as per IS-14246:95 (JIS:3312 polyester coating 30-40 micron) as in roof etc fixed etc fixed to iron /wooden members with self drilling zinkallum coated metal screws having cap with rubber washers more than 3.00sqm patches as required in shapes complete all as specified and directed. Make: (a) Lloyd Insulation (b) Tata bluescope steel building solutions Ltd. (c) Prestar Infrastructure Project Ltd (d) Colour Roof India Ltd.(CRIL) (e) M/s Matco Roof PvtLltd. (f) Ispat Industries Ltd (g) Everest Industries
S & F plain regular modified Polyester colour coated galvanized steel profile sheet (TCT) 0.50mm thick having tensile strength of 550 Mpa as in ridge, valley gurtter, drip and straight flashing fixed with self tapping screws of reqd size and dia with head having matching colour PVC cap / painted as of sheet total mass coating 150 gms/sqm (both side) in roofing complete all as specified and directed. Make: (a) Lloyd Insulation (b) Tata bluescope steel building solutions Ltd. (c) Prestar Infrastructure Project Ltd (d) Colour Roof India Ltd.(CRIL) (e) M/s Matco Roof PvtLltd. (f) Ispat Industries Ltd (g) Everest Industries
S&F wind ties for roof including securing bolts as directed, including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for PCC type B0 (1:2:4 using 12.5mm graded stone aggregate) as in roof kerb, benching/ padding over roof surface including chamfered on eges etc complete all as directed.
Demolition of unreinforcement cement concrete of any description and in position not otherwise specifically provided for complete all as specified and directed
Demolition of plain cement concrete in ground floor and pavings not exc 15cm thickness below or above ground level complete all as specified and directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified. (Note : Debris obtained from dismantling will be dispossed off as directed)
Demolition of stone slabs and tiles of any description or thickness in floors, approns etc laid, bedded and pointed in any mortar. (Note : Debris obtained from demolition will be dispossed off as directed)
Demolition of brick work of any description and in any position built in cement mortar including quoins arches and pillars complete all as specified.
M&L for brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 for manholes, drains, septic tanks, soak wells etc. complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in copings, kerbs, filling for fixing of hold fast etc including necessary formwork etc.
M&L 25mm thick PCC (1:2:4) type B0, (using 12.5mm graded stone aggregate) as in floor to receive tiles complete all as specified.
M&L 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and as directed.
M & L for vitrified coloured tiles of 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, polished as in floors laid over 15mm thick screed or screed bed in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles all as specified.
All as per Item No (44) here-in- before but as in skirting over 10 mm thick rendering in CM (1:4) all as specified and as directed.
M&L for glazed ceramic tiles coloured, joint free in vertical surface 300X 450X 7mm thick mm thick as on walls over and incl 10mm thick rendering in cement mortar (1:4) and jointing in neet slurry and pointing in coloured cement to match the inside of tiles all complete as specified and directed.
Material and labour for 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms/slabs and like laid over 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite half round on exposed projected surfaces all as specified and as directed.
M&L Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid 15 mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M&L Machine cut kota stone slab 18-20mm thick in riser of steps,skirting ,dado and pillar laid over 10mm thick rendering of cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified.
M&L 75 mm thick PCC (1:3:6) type C1(using 20 mm graded stone aggregate) as in plinth protection and paving laid in alternate bays finished finish even and smooth wihtout using extra cement complete all as specified and as directed
Taking down cement plaster on bricks including raking out joints hacking for key scrubbing down with water etc.complete all as specified.
M & L 15mm thick rendering in cement mortar 1:6 on brick or concrete surfaces of wall even and smooth complete all as specified.
M & L 15mm thick rendering in cement mortar 1:4 on brick or concrete surfaces, mixed with water proofing compound as per manufacturer's instructions, surfaces finished even and smooth complete all as specified and directed by Engineer-In-Charge. Note:- WPC measured and paid separately.
M & L 15mm thick rendering in cement mortar 1:4 on brick or concrete surfaces of wall finished even and smooth complete all as specified.
Supply only integral water proofing compound. ISI Marked.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper on surfaces of wall over a coat of primer and wall care putty for getting smooth surface complete all as specified and directed.
M&L for complete removal of existing treatment from surface of walls and preparation of old plastered surfaces and applying two coats of oil bound distmper on old surfaces of wall over a coat of primer and wall care putty for getting smooth surface complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of exterior emulsion paint (Weather coat) of approved shade on plastered surfaces of wall over a coat of primer and wall care putty for getting smooth surface complete all as specified and directed.
M&L for complete removal of existing treatment from surface of walls and preparation of old plastered surfaces and applying two coats of exterior emulsion paint (Weather coat) of approved shade on plastered surfaces of wall over a coat of primer and wall care putty for getting smooth surface complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide & over 10cm width or girth complete all as specified.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide n.exc 10cm width or girth complete all as specified.
M & L preparation of old steel surfaces of any description over 10 cm width or girth and apply two coats of synthetic enamel paint complete over truss, purlin etc all as specified and directed.
M&L for preparation of new wooden surfaces width or girth exc 10 cm and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified .
M&L for preparation of old wooden surfaces width or girth exc 10 cm and applying two coat of synthetic enamel paint complete all as specified.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store .
S&F 15 mm bore galvanized steel tubes medium grade with all fittings laid concealed/surface in walls complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified
S&F 20 mm bore galvanized steel tubes medium grade with all fittings laid in walls complete all as specified.
Dismantling PVC water tanks of capacity exc 500 ltr but n exc 1000 ltr and removing to store complete all as specified and directed.
S&F HDPE triple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including GI nipple of suitable size complete all as specified and directed.
S&F in repairs ball valve high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed 20mm bore complete all as specified.
S&F in repairs 20mm dia of bore Gun - metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed.
S&F in repair sink made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mmcomplete all as specified and directed.
S&F in repairs Chromium plated brass soap dish/ tray fixed with wall complete all as specified and directed.
S&F in repair 15mm bore CP fancy type short body bib tap with capstan head complete all as specified including flange.
S&F in repair stainless steel gratings suitable for 100 mm floor trap complete all as specified and as direcred.
S&F in repair PVC waste pipe 32/40mm dia suitable for WHB/Sink etc complete all as specified and directed.
Demolition of reinforced cement concrete of roofs, floors (other than ground floors) beams staircases landing chajjas and similar suspended work etc complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as directed.
M&L for mild steel deformed TMT bars 10mm dia and over (as in reinforcement) cut to length, bent to shape require including cranking, bending spirally for hooking for column, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips.
M&L for RCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified.
Point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25 mm dia with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified. Make of Cable : Havells, Polycab,RR Kabel and Make of Conduit : Havells/Kamplast/Polycab/plaza.
All as per srl item No-83 here in above but upto ceiling height and on surface at ceiling.
All as per srl item No-83 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit.
All as per srl item No-83 here in above but for one 3 pin 5A socket outlet independent controlled by one switch.
All as per srl item No-83 here in above but for one 5A socket outlet on the same board controlled by one switch.
M&L for switch piano flush button single pole one way 5/6 amps 240 volts. Make : Anchor/SSK/Leader
M & L for switch piano flush button single pole one way 15/16 amps 240 Volts. Make :Anchor/SSK/Leader
M&L for socket outlet 5 amps 5 pin flush type, 240 volts. Make : Anchor/SSK/Leader
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts. Make : Anchor/SSK/Leader
M&L for ceiling rose surface bakelite 3 terminals. Make : Anchor/SSK/Leader
S & F Lamp holder insulated body with back plate for dome batten fittings.Make :Anchor/SSK/Leader
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed by engineer-in-charge. Make : Anchor/SSK/Leader
M&L in replacement for submain wiring with four single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 6 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade 32mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed by Engr-in- charge. Make of Cable : Havells, Polycab,RR Kabel and Make of Conduit : Havells/Kamplast/Polycab
S&F in replacement of wall mounted LED light fittings 20/22 watt, 6500/3000K, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete connecting electrically all as directed. Make : Havells/Phillips/Wipro
S&F in replacement of LED mirror light fitting min 10 Watt Watt,1' long, with efficient heat dissipation and integrated electronic driver complete connecting electrically all as directed. Make : Havells/Phillips/Wipro
Supply and fix in replacement of High power LED street light 25 Watt Energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver incl suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated complete all as spfd. Make : Havells/Phillips/Wipro/Crompton
S & F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification. make :Havells/Legrand/Indoasian
S & F distribution board iron clad, double door with IP-43, IK-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s VTPN DB 4 way, complete with appropriate size copper bus bar and neutral link, complete with one MCCB 3 pole 415 Volts 63 Amps rating with rupturing cap 25 kA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed. Make: Legrand/Havells/Indoasian
M&L for MCB single pole 240 volts 5 to 30 amps, with rupturing capacity 10 kA using thimbles of required size. Make: Legrand/Havells/L&T/Indoasian
M&L MCB single pole & neutral 240 volts 63 amps,with rupturing capacity 10 kA using thimbles of required size. Make: Legrand/Havells/L&T/Indoasian
M&L for single pole and neutral enclosure with a top pin, earth plug and socket copmlete with one SP MCB 25 Amps, 240 Volts. Make: Legrand/Havells/ABB/L&T
M&L for RCCB ,double pole,single phase 240 volts , rated current 40 amp, sensitivity 30 mA complete using thimbles of required size complete suitable for fitted in DB.Make: Legrand/Havells/L&T/Indoasian
S & F Ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 200 CFM with BEE 5 star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make : Usha/Havells/Orient
S & F Hot water heater storage type 25 ltr Cap, 5 star rated with fast heating upto max wattage 2000 watt,pressure upto 8 bar,with capillary thermostat and automatic thermal cut off safty anti rust design,with 5 yr warantee on MS Tank complete Make : V guard/Crompton/Havells
Supply and install of fresh air fan(ventilator) 240 V ,AC single phase of size not less than 200 mm sweep ,900 rpm, plastic body complete with fixing arrangement , electric connection incl with rubber mounting for silent operation, grouting of nuts, bolts,in wall/ventilator,all as sepcified and as directed by Engr-in-charge.
M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to galvanised earth lead wire 4.0mm dia by means of nuts,bolt,washers etc.of copper / brass connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,GI water pipe with 20mm dia.funnel &wire mesh PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity.
Disconnecting Electrically and taking out old unsv LT UG cable any typw of size upto 35 sqmm 3.5C all as spfd and directed.
Supply and Laying in trenches or fixing to wall /pole or passing through pipes insulated heavy duty electric cable with alluminium conductor 1100V volts grade cross sectional area 35 sqmm 3.5C complete
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,foundation filling of poles or stays and for rerouting of cables.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
Disconnecting electrically and taking down existing ceiling fan any type and capacity with due care dismantling blades with down road and handing over to MES store yard with all accessories all as specified and directed. Note: T&P will be provided by the contractor for reaching any height of the bldg.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30/45 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 3742019), THD less than 10%, without remote and electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete all as specified. Make - Havells/Bajaj/Orient/ Crompton as approved by GE. Note : (a) Make, Model & Colour of fan as approved by GE. (b) Writing MES No. in black synthetic enamel paint by the contractor. (c) T & P will be provided by the contractor for reaching any height of the bldg.
S & F of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade, duly threaded with clamp (factory fabricated) rubber reel, nuts, bolts incl painted with two coats of synthetic white enamel over a coat of red oxide , length upto 1.00 metre long complete all as specified and directed
S & F of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade, duly threaded with clamp (factory fabricated) rubber reel, nuts, bolts incl painted with two coats of synthetic white enamel over a coat of red oxide , length upto 1.50 metre long complete all as specified and directed
S & F of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade, duly threaded with clamp (factory fabricated) rubber reel, nuts, bolts incl painted with two coats of synthetic white enamel over a coat of red oxide , length upto 2.00 metre long complete all as specified and directed
S & F of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade, duly threaded with clamp (factory fabricated) rubber reel, nuts, bolts incl painted with two coats of synthetic white enamel over a coat of red oxide , length upto 3.00 metre long complete all as specified and directed
S & F of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade, duly threaded with clamp (factory fabricated) rubber reel, nuts, bolts incl painted with two coats of synthetic white enamel over a coat of red oxide , length upto 4.00 metre long complete all as specified and directed
S & F of PVC rounded 3 core 1.50 sqmm copper cable and making necessary connection complete all as specified & directed. Make : Polycab / Finolex / Havells / Plaza.
Ashirwad Contractor and Supplier
FATEHPUR CONSTRUCTION COMPANY
murty construction company
M/s DKS Engineering Works
Allied Builders And Engineers
Khalil Ahmed and Sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .